Wyniki wyszukiwania dla: MONITORING IN-SITU
-
Optoelectronic system for monitoring of thin diamond layers growth
PublikacjaDevelopment of the optoelectronic system for monitoring of diamond/DLC (Diamond-Like-Carbon) thin films growth during mu PA ECR CVD (Microwave Plasma Assisted Electron Cyclotron Resonance Chemical Vapour Deposition) process is described. The multi-point Optical Emission Spectroscopy (OES) and Raman spectroscopy were employed as non-invasive optoelectronic tools. Dissociation of H-2 molecules, excitation and ionization of hydrogen...
-
Monitoring of activities carried out as part of prototyping and implementation of the pilot project in the area of the "Polanki" market and its direct neighbourhood, in the Gdańsk-Oliwa district, step2; stage from June 2021 year.
Dane BadawczeThe data presents tabular monitoring lists (quantitative and qualitative documentation report in the form of tables) of activities carried out as part of prototyping and implementation of the pilot project in the area of the Polanki market and its immediate vicinity in the Gdańsk-Oliwa district in 2021 year - step 2, stage from June 2021.The monitoring...
-
Monitoring of activities carried out as part of prototyping and implementation of the pilot project in the area of the "Polanki" market and its direct neighbourhood, in the Gdańsk-Oliwa district, step2; stage from September 2021 year.
Dane BadawczeThe data presents tabular monitoring lists (quantitative and qualitative documentation report in the form of tables) of activities carried out as part of prototyping and implementation of the pilot project in the area of the Polanki market and its immediate vicinity in the Gdańsk-Oliwa district in 2021 year - step 2, stage from September 2021.The monitoring...
-
Monitoring of activities carried out as part of prototyping and implementation of the pilot project in the area of the "Polanki" market and its direct neighbourhood, in the Gdańsk-Oliwa district, step2; stage from October 2021 year.
Dane BadawczeThe data presents tabular monitoring lists (quantitative and qualitative documentation report in the form of tables) of activities carried out as part of prototyping and implementation of the pilot project in the area of the Polanki market and its immediate vicinity in the Gdańsk-Oliwa district in 2021 year - step 2, stage from October 2021.The monitoring...
-
Monitoring of activities carried out as part of prototyping and implementation of the pilot project in the area of the "Polanki" market and its direct neighbourhood, in the Gdańsk-Oliwa district, step2; stage from July 2021 year.
Dane BadawczeThe data presents tabular monitoring lists (quantitative and qualitative documentation report in the form of tables) of activities carried out as part of prototyping and implementation of the pilot project in the area of the Polanki market and its immediate vicinity in the Gdańsk-Oliwa district in 2021 year - step 2, stage from July 2021.The monitoring...
-
Monitoring of activities carried out as part of prototyping and implementation of the pilot project in the area of the "Polanki" market and its direct neighbourhood, in the Gdańsk-Oliwa district, step2; stage from May 2021 year.
Dane BadawczeThe data presents tabular monitoring lists (quantitative and qualitative documentation report in the form of tables) of activities carried out as part of prototyping and implementation of the pilot project in the area of the Polanki market and its immediate vicinity in the Gdańsk-Oliwa district in 2021 year - step 2, stage from May 2021.The monitoring...
-
Monitoring of activities carried out as part of prototyping and implementation of the pilot project in the area of the "Polanki" market and its direct neighbourhood, in the Gdańsk-Oliwa district, step2; stage from August 2021 year.
Dane BadawczeThe data presents tabular monitoring lists (quantitative and qualitative documentation report in the form of tables) of activities carried out as part of prototyping and implementation of the pilot project in the area of the Polanki market and its immediate vicinity in the Gdańsk-Oliwa district in 2021 year - step 2, stage from August 2021.The monitoring...
-
Multimedia services applied to noise and hearing monitoring and measuring
PublikacjaThe goal of this chapter is to show a research study related to processing of data acquired by the multimedia services engineered at the multimedia systems department (MSD) of the Gdansk University of Technology. This concerns a survey on noise threat employing the multimedia noise monitoring system (MNMS) and hearing tests performed by the "I can hear. . . " system. The obtained results of the noise measurements revealed that...
-
RAMAN DIAGNOSTICS OF CVD DIAMOND GROWTH
PublikacjaDevelopment of Raman spectroscopic system for diagnostics of growth of diamond and BDD (Boron- Doped-Diamond) thin films during μPA CVD (Microwave Plasma Assisted Chemical Vapour Deposition) process is described. Raman studies of such films were carried out as in-situ monitoring of film deposition as ex-situ measurements conducted for a sample outside the reaction vessel after manufacturing process. Modular system for the in-situ...
-
Instantaneous impedance monitoring of AA 7075 aluminum alloy corrosion in borate buffer with admixed chloride ions
PublikacjaThe study presents a research capabilities of Dynamic Electrochemical Impedance Spectroscopy (DEIS) as a tool used for instantaneous on-line monitoring of corrosion processes on the example of AA 7075 aluminum alloy. A borate buffer with admixed chloride ions in a quantity ranging from 0.05 to 25 mM was used to represent different types of corrosion attack. The surface of samples specimens was evaluated before and after the tests...
-
An in situ technique for the assessment of adhesive properties of a joint under load
PublikacjaSlow crack propagation in adhesive bonded joints has been characterised using an asymmetric wedge test. Crack position was evaluated from strain gauge measurements, both in the debonded partof the joint and in the bonded zone. Test temperature was changed during loading, giving insight into bond evolution. The technique allows accurate, and virtually continuous, determination of crack position to be made, and therefore the evaluation...
-
Wytłaczanie past ceramicznych - optyczny monitoring poślizgu przyściennego
PublikacjaPrzedmiotem niniejszej pracy jest optyczna metoda spektroskopii reflektancyjnej do pomiaru in situ grubości warstwy przyściennej w procesie wytłaczania past ceramicznych, którą można stosować bez zakłócania przebiegu procesu. Może ona znaleźć zastosowanie do dostarczania danych w analizie i modelowaniu procesu wytłaczania, a także do kontroli on-line przebiegu procesu produkcyjnego.
-
BADANIA KOMPOZYTOWEGO MOSTU DLA PIESZYCH
PublikacjaThe paper presents in situ load testing of the innovative footbridge of FOBRIDGE grant mounted at Gdansk University of Technology. The span of composite sandwich structure (GFRP skins, PET core) and the scope of static and dynamic tests are presented. The selected, representative results of in situ measurements and data obtained from the SHM monitoring system are discussed. Besides the standard testing procedures on the full scale...
-
Dynamic Response of the Suspended on a Single Cable Footbridge
PublikacjaThe article presents numerical simulations, dynamic in situ load tests and a structural health monitoring (SHM) system installed in a suspended on a single cable footbridge. Numerical simulations performed prior to construction indicated the possibility of structural dynamics problems, finally confirmed in the course of dynamic test loading. In the dynamic load course the bridge deck developed vibrations displaying accelerations...
-
Chapter 8 – Active Sampling of Air
PublikacjaThis chapter reviews the literature information on analytical techniques and laboratory equipment used for active sampling of air (atmospheric and indoor) in regular monitoring research. It describes popular analytical devices applied for sample collection using various types of polymeric bags, e.g. Tedlar bags, Teflon or Nafion bags, and/or stainless steel vacuum containers. It reviews literature data about the application of...
-
Application of passive sampling techniques as a usable tool in the field of environmental quality monitoring
PublikacjaAnalysis of literature data published for the past 20 years leads to the conclusion, that passive sampling technique has been developing very quickly and is commonly used in the field of monitoring pollutants in air, water and soil environment. The popularity of application of passive sampling techniques in analytical and environmental chemistry results from its many advantages e.g.: Simplicity in use, low costs of exploitation,...
-
The Application of a Mobile Unmanned Device for Monitoring Water and Sediment Pollution in the Port of Gdynia
PublikacjaPollution in the Port of Gdynia can encompass various types of substances and contaminants that affect the quality of water and sediment in this region. Ships entering and leaving the port can release pollutants such as oil, fuel, waste, and chemicals into the water. Controlling and monitoring these pollutants is a crucial part of environmental stewardship. In recent years, uncrewed units have been increasingly in use for in situ...
-
SHM System of the Roof Structure of Sports Arena “Olivia”
PublikacjaThe paper presents a structural health monitoring system of the Sports Arena “Olivia” in Gdansk, Poland. The system was installed because of doubts about the roof stability due to observed buckling of the steel truss members. The SHM system was based on nonlinear FEM models used for detection of type of near failure modes of the roof. The application of detailed FEM model in current state updated on data from in situ loading testes...
-
Optoelektroniczny monitoring stanu wzbudzenia plazmy niskotemperaturowej w procesach syntezy optycznych warstw diamentopodobnych
PublikacjaZrealizowana praca jest jednym z głównych zadań wieloletniego projektu badawczego z zakresu syntezy warstw diamentopodobnych. Celem bezpośrednim pracy było określenie rozkładu wzbudzenia plazmy w komorze technologicznej stanowiska PA ECR CVD. Głównym celem było opracowanie optoelektronicznego systemu pomiarowego, na którego potrzeby zastosowano przestrzennie selektywną optyczną spektroskopię emisyjną dedykowaną do badania procesu...
-
Understainding solid-phase microextraction: key factors influencing the extraction process and trends in improving the technique
PublikacjaAnalytical chemists are faced with the daunting challenges of accurately monitoring the state of the environment and the processes taking place in it and of determining an enormous range of analytes often present in trace and ultratrace amounts in sample matrixes with complex or variable compositions. Further challenges are presented by the need to introduce new methodologies into current analytical practice and equipment to comply...