Wyniki wyszukiwania dla: circuit mode
-
Representation of magnetic hysteresis in a circuit model of a single-phase transformer
PublikacjaThe paper presents a mathematical model for the hysteresis phenomenon in a multi-winding single-phase core type transformer. The set of loop differential equations was developed for K-th winding transformer model where the flux linkages of each winding includes a flux common Φ to all windings as function of magneto motive force Θ of all windings. The first purpose of this paper is to determine a hysteresis nonlinearity involved...
-
Iron Core Inductor High Frequency Circuit Model for EMC Application
PublikacjaW referacie przedstawiono szerokopasmowy model obwodowy dławika z rdzeniem ferromagnetycznym przydatny do analizy propagacji zaburzeń elektromagnetycznych przewodzonych w układach przekształtnikowych. Opracowany model uwzględnia zmiany właściowści dławika w zakresie wysokich cżstotliwosci na skutek występowania naskórkowości, prądów wirowych oraz efektu zbliżenia w uzwojeniach.
-
A LUMPED-CIRCUIT MODEL OF CIRCULAR PISTON TRANSDUCER FOR MODELING ITS PERFORMANCE IN DUAL FREQUENCY OPERATING MODES
PublikacjaThe paper presents novel network equivalent circuit of piezoceramic circular disc transducer that takes into account thickness and ra dial mode of vibrations. The starting point of the analysis is 4-port description of circular disc element representing the solution of wave equation set in radial and thickness directions. Th e approximate solution for harmonic case is represented in the form of 4x4 matrix, which is syn thesized...
-
Non-linear circuit model of a single doubly-fed induction machine formulated in natural axes for drive systems simulation purposes
PublikacjaMathematical modelling and a circuit model formulated in natural axes of a single doubly-fed induction machine, with the account of magnetic circuit nonlinearity are presented in the paper. Derivation of the model differential equations was based on Lagrange's energy method. State functions of magnetic elements in the model are non-linear and depend on all currents flowing in the machine windings and on the angle of rotor position....
-
The surface of a fragment of the structure of an integrated circuit in the semi-contact mode.
Dane BadawczeThe surface of a fragment of the structure of an integrated circuit. Topographic measurements in the semi-contact mode. NTEGRA Prima (NT-MDT) device. NSG 01 probe.
-
Capacitively coupled ECG measurements - a CMRR circuit improvement
PublikacjaA typical galvanic-connected electrocardiogram (ECG) measurement system utilizes two signal’s electrodes and a third one in driven-right-leg (DRL) circuit for improving a common-mode rejection ratio(CMRR) of the acquisition system. In capacitive-coupled ECG similar techniques are used, however it is expected, that the utilized DRL subsystem is formed using a capacitive coupling approach, too. An improvement of the acquisition system...
-
Broadband Modeling of Motor Cable Impact on Common Mode Currents in VFD
PublikacjaExamination of conducted EMI generation and propagation in AC motor drives fed by frequency converter requires to consider parasitic capacitances in converters, motor windings and feeding cables to be taken into account. AC motor winding voltage transients and related common mode currents are significantly correlated with resonance effects occurring in converter's load circuits. Intensity levels of these phenomena depend...
-
A spice equivalent circuit for modeling the performance of dual frequency echo-sounder
PublikacjaThe paper presents novel network equivalent circuit of piezoceramic circular disc transducers that takes into account thickness and radial mode of vibrations. The starting point of the analysis is 4-port description of circular disc element representing the solution of wave equation set in radial and thickness directions. The approximate solution for harmonic case is represented in the form of 4x4 matrix, which is synthesised and...
-
Modeling of Common Mode Currents Induced by Motor Cable in Converter Fed AC Motor Drives
PublikacjaInvestigation of conducted EMI generation in AC motor fed by pulse width modulated frequency converters requires to consider parasitic capacitances in converters, motor windings and feeding cables to be taken into account. Motor voltage transients and related common mode currents are significantly correlated with resonance effects occurring in load circuits. An analysis of frequency converter load impedance-frequency characteristics...
-
Programmable Input Mode Instrumentation Amplifier Using Multiple Output Current Conveyors
PublikacjaIn this paper a programmable input mode instrumentation amplifier (IA) utilising second generation, multiple output current conveyors and transmission gates is presented. Its main advantage is the ability to choose a voltage or current mode of inputs by setting the voltage of two configuration nodes. The presented IA is prepared as an integrated circuit block to be used alone or as a sub-block in a microcontroller or in a field...
-
Common-Mode Voltage and Bearing Currents in PWM Inverters: Causes, Effects and Prevention
PublikacjaIn modern induction motor drives an increase of transistors' switching frequency and a decrease of switching times are the sources of some serious problems. The high dv/dt and the common mode voltage generated by the inverter PWM control results in the appearances of bearing currents, shaft voltages, motor terminal overvoltages, the decrease of motor efficiency, and electromagnetic interference. The aspects of common mode (CM)...
-
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublikacjaThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...
-
Reducing common mode voltage and bearing currents in quasi - resonant DC - link inverter
PublikacjaIn the paper, a concept of separation of an inverter-fed induction motor drive from its mains supply by two transistor switches inserted in the dc-link circuit is reexamined based on the proposed parallel quasi-resonant dc-link inverter (PQRDCLI). The objective of the paper is to show an advantage of the proposed topology in limiting high frequency common mode voltage and bearing currents. In the laboratory setup, an induction...
-
Design and Experiments of a Piezoelectric Motor Using Three Rotating Mode Actuators
PublikacjaThis paper represents a numerical and experimental investigation of the multicell piezoelectric motor. The proposed design consists of three individual cells that are integrated into the stator, double rotor, and a preload system combined into a symmetrical structure of the motor. Each of the cells is characterized by a traveling wave and rotating mode motor. A finite element numerical analysis is carried out to obtain optimal...
-
EMI attenuation in a DC-DC buck converter using GaN HEMT
PublikacjaA dc-dc buck converter using gallium nitride (GaN) high electron mobility transistors (HEMT) is experimentally investigated at the discontinuous current mode (DCM) and at the triangular current mode (TCM) operation. The paper objective is to specify the power conversion efficiency and attenuation of common mode (CM) and differential mode (DM) noise voltage, measured at the line impedance stabilization network (LISN) for compared...
-
The influence of dynamic load changes on temporary impedance in hydrogen fuel cells, selection and validation of the electrical equivalent circuit
PublikacjaTo achieve optimal performance of a fuel cell, a reliable monitoring and diagnostic method is required. The currently utilized methods give limited information or they are impossible to use under dynamic working conditions. To obtain comprehensive information about the fuel cell operation we utilized novel dynamic electrochemical impedance spectroscopy. Impedance measurements in dynamic mode were performed on a hydrogen fuel cell,...
-
DIGITAL HYDRAULICS CIRCUIT BASED ON PWM FUNCTION FOR CONTROLLING HYDRAULIC ACTUATOR POSITION
PublikacjaHydraulic systems are used in many different industries, such as multi-source hydrostatic drive systems. In traditional hydraulic systems, a proportional servo valve is used to control the position of hydraulic actuators. The low energy efficiency and high cost of these control valves are two major problems with these systems. Digital hydraulics is one of the most unique ideas on how to solve these problems. Researchers like digital...
-
Quasi-resonant DC-link voltage inverter with enhanced zero-voltage switching control
PublikacjaA new topology modification of the parallel quasi-resonant circuit for a dc-link voltage inverter enables regulation of the zero voltage dc-link subperiods and the dc-link voltage gradient settings. The proposed circuit is based on four MOSFET switches with free-wheeling diodes for controlled quasi-resonant recharging between L-C tank in order to assure inverter zero voltage switching (ZVS) conditions. Design optimization of the...
-
The microstructure of aluminium alloys AA1050 and AA7075 subjected to anodic polarization at 8V in KOH electrolyte
Dane BadawczeThe dataset contains SEM pictures of the microstructure of aluminum alloy AA1050 and AA7075 exposed in aqueous KOH in the pH range between 14–11. Two sets of samples are presented, revealing the topography of the alloys when exposed to aggressive media under open circuit potential conditions as well as when subjected potentiodynamic polarization ranging...
-
Stanowisko do diagnostyki i regulacji wyzwalaczy przekaźników w obwodach lokomotyw elektrycznych
PublikacjaFast circuit breaker and protective relays play an important role of protecting locomotive’s electrical circuits from damage caused by short circuit or overload. Undisturbed operation and proper circuit protection depends on the technical condition and fine calibration of the over-current trips. Therefore the relays should be subject to periodic inspection and adjustment due to locomotive maintenance schedule. A test stand for...