Investigation of the Effects of Tool Positioning Factors on Peak Temperature in Dissimilar Friction Stir Welding of AA6061-T6 and AA7075-T6 Aluminum Alloys
PublikacjaAmong the emerging new welding techniques, friction stir welding (FSW) is used frequently for welding high-strength aluminum alloys that are difficult to weld by conventional fusion-welding techniques. This paper investigated the effects of tool-positioning factors on the maximum temperature generated in the dissimilar FSW joint of AA6061-T6 and AA7075-T6 aluminum alloys. Three factors of plunge depth, tool offset, and tilt angle...
-
Experimental-Numerical Analysis of the Effect of Bar Diameter on Bond in Pull-Out Test
PublikacjaBar diameter is one of the basic factors affecting bond behavior, which is still of interest due to opposing opinions regarding its effect on bond behavior in the pull-out test. This paper presents an experimental and numerical bond analysis of ribbed reinforcing bar in concrete. The aim was to experimentally evaluate the effect of bar diameter on the bond behavior in the pull-out test and to perform numerical simulations of the...
-
POM/EVA Blends with Future Utility in Fused Deposition Modeling
PublikacjaPolyoxymethylene (POM) is one of the most popular thermoplastic polymers used in the industry. Therefore, the interest in its potential applications in rapid prototyping is understandable. Nevertheless, its low dimensional stability causes the warping of 3D prints, limiting its applications. This research aimed to evaluate the effects of POM modification with ethylene-vinyl acetate (EVA) (2.5, 5.0, and 7.5 wt.%) on its processing...
-
GTR/Thermoplastics Blends: How Do Interfacial Interactions Govern Processing and Physico-Mechanical Properties?
PublikacjaIn this work, GTR/thermoplastics blends (in ratio 50/50 and 75/25 wt.%) were prepared by melt-compounding in an internal mixer. During research, trans-polyoctenamer rubber (TOR), ethylene-vinyl acetate copolymer (EVA), ethylene-octene copolymer (EOC), and linear low-density polyethylene (LLDPE), were used in their thermoplastic phase. Microstructure and processing-performance property interrelationships of the studied materials...
-
Modelling of laminated glass PVB walls of buildings exposed to vehicle impact with different speeds
PublikacjaThis paper presents an analytical model, developed for laminated glass subjected to a low-velocity impact. It has the ability to capture glass cracks as well as large non-linear deformations. It is based mathematically on the firstorder deformation concept, which considers the effect of membrane and transverse shear as well as bending. This theory uses damage mechanics to capture the glass cracking. For this purpose, several experiments...
-
Chitosan-Based Membranes as Gentamicin Carriers for Biomedical Applications — Influence of Chitosan Molecular Weight
PublikacjaOver the past decade, much attention has been paid to chitosan as a potential drug carrier because of its non-toxicity, biocompatibility, biodegradability and antibacterial properties. The effect of various chitosan characteristics on its ability to carry different antibiotics is discussed in the literature. In this work, we evaluated the influence of the different molecular weights of this polymer on its potential as an antibacterial...
-
Polyurethanes Crosslinked with Poly(vinyl alcohol) as a Slowly-Degradable and Hydrophilic Materials of Potential Use in Regenerative Medicine
PublikacjaNovel, slowly-degradable and hydrophilic materials with proper mechanical properties and surface characteristics are in great demand within the biomedical field. In this paper, the design, synthesis, and characterization of polyurethanes (PUR) crosslinked with poly(vinyl alcohol) (PVA) as a new proposition for regenerative medicine is described. PVA-crosslinked PURs were synthesized by a two-step polymerization performed in a solvent...
-
High load capacity spur gears with conchoidal path of contact
PublikacjaThe present study is devoted to investigation of spur gears with a conchoidal path of contact and a convex-convex contact between teeth. The load capacity and energy efficiency were evaluated using both theoretical and experimental approaches. The theoretical analysis showed that the conchoidal gear pairs are 5–21% stronger in terms of contact stress and have similar energy efficiency as compared to the involute gear pairs of the...
-
Numerical and Clinical Analysis of an Eyeball Injuries under Direc Impact
PublikacjaObjectives: The objective of this study was to develop a numerical model of the eyeball and orbit to simulate a blunt injury to the eyeball leading to its rupture, as well as to conduct a comparative analysis of the results obtained using the finite element method against the clinical material concerning patients who had suffered an eyeball rupture due to a blunt force trauma. Material and Methods: Using available sclera biometric and...
-
A comprehensive evaluation of flexible FDM/FFF 3D printing filament as a potential material in medical application
PublikacjaThe use of FDM/FFF in 3D printing for medical sciences is becoming common. This is due to the high availability and decent price of both 3D printers and filaments useful for FDM/FFF. Currently, researchers' attention is focused mainly on the study of medical filaments based on PLA, PCL or their modifications. This contributes to insufficient diversity of medical-grade filaments on the market. Moreover, due to the lack of specified...
-
Applying of Doped Graphene Oxide Coatings for Corrosion Prevention
PublikacjaINTRODUCTION Graphene is a carbonaceous material characterized by extraordinary properties (high electron mobility, high surface area, high mechanical strength of 1100 GPa, very dense network hindering the passage of even the smallest helium atoms) [1]. Therefore, it found many applications, also as an anti-corrosive layer [2]. Electrophoretic Deposition (EPD) is one of the methods to deposit coatings. However, due to slight solubility...
-
3D scanning system for railway current collector contact strips
PublikacjaUndisturbed collection of current from a contact wire of the catenary constitutes one of the basic elements in reliable operation of electrified rail transport, particularly when vehicles move at high speed. Quality of current collection is influenced by the construction of catenary and current collectors, as well as by the technical condition and regulation of these two elements. Total contact force of a current collector head...
-
The Effect of Surface Modification of Ti13Zr13Nb Alloy on Adhesion of Antibiotic and Nanosilver-Loaded Bone Cement Coatings Dedicated for Application as Spacers
PublikacjaSpacers, in terms of instruments used in revision surgery for the local treatment of postoperative infection, are usually made of metal rod covered by antibiotic-loaded bone cement. One of the main limitations of this temporary implant is the debonding effect of metal–bone cement interface, leading to aseptic loosening. Material selection, as well as surface treatment, should be evaluated in order to minimize the risk of fraction...
-
The new version of contact-less method for localisation of catenary contact wire – theoretical assumption
PublikacjaThis article presents the theoretical basic of a new version of contact-less method for localising the catenary contact wires, using the advanced video techniques and image analysis. So far, contact line diagnostic systems exploited nowadays uses the contact measuring methods with special design current collector. This solutions make it impossible to measure the contact line geometry in a static way. The proposed measurement method...
-
Algorithm for Automatic Wear Estimation of Railway Contact Strips Based on 3D Scanning Results
PublikacjaElectric rail vehicles use current collection system which consists of overhead contact line and a current collector (pantograph) mounted on the roof of a vehicle. A pantograph is equipped with contact strips, which slide along the contact wire, ensuring steady electric contact. Contact strips are made of carbon layer, fixed to an aluminum carrier. The carbon layer wears down due to friction. Using overly worn contact strips increases...
-
A chemo-mechano-thermodynamical contact theory for adhesion, friction, and (de)bonding reactions
PublikacjaThis work presents a self-contained continuum formulation for coupled chemical, mechanical, and thermal contact interactions. The formulation is very general and, hence, admits arbitrary geometry, deformation, and material behavior. All model equations are derived rigorously from the balance laws of mass, momentum, energy, and entropy in the framework of irreversible thermodynamics, thus exposing all the coupling present in the...
-
Visual method for detecting critical damage in railway contact strips
PublikacjaEnsuring an uninterrupted supply of power in the electric traction is vital for the safety of this important transport system. For this purpose, monitoring and diagnostics of the technical condition of the vehicle's power supply elements are becoming increasingly common. This paper presents a new visual method for detecting contact strip damage, based on measurement and analysis of the movement of the overhead contact line (OCL)...
-
Partition of friction heat between sliding semispaces due to adhesion-deformational heat generation
PublikacjaAnalytical expressions of heat-partition coefficient and contact temperatures for two sliding semispaces with account for adhesion-deformational heat generation and contact heat exchange have been obtained. The rate of deformational heat generation is assumed to decay exponentially with increase of distance from the interface. It has been shown that heat-generation configuration and the intensity of contact heat exchange have impact...
-
Wavelet transform-based approach to defect identification in railway carbon contact strips.
PublikacjaPantographs of electric rail vehicles are fitted with carbon contact strips, which slide along the contact wire of catenary to provide constant electrical contact. Contact strips are exposed to wear and damages. Using damaged contact strips significantly increases the risk of catenary rupture. Therefore, their technical condition has to be inspected frequently. In previous work a 3D laser scanning system was proposed for recording...
-
Estimation of electrode contact in capacitive ECG measurement
PublikacjaIn the paper a method of electrode’s contact estimation in capacitive electrocardiogram (CECG) is presented. Proposed solution allows estimation of contact quality for each individual electrode. This enables construction of multi-electrode CECG systems, where electrode pairs can be selected on the basis of the individual electrode contact quality.