Filtry
wszystkich: 537
Wyniki wyszukiwania dla: FABRIC/TEXTILES
-
Implementation of SiN thin film in fiber-optic sensor working in telecommunication range of wavelengths
PublikacjaMirrors are used in optical sensors and measurement setups. This creates a demand for mirrors made of new materials and having various properties tailored to specific applications. In this work, we propose silicon covered with a thin silicon nitride layer as a mirror for near-infrared measurements. SiN layer was deposited on a standard silicon wafer with a Low-Pressure Chemical Vapor Deposition furnace. Then, the created layer...
-
Temperature Sensors Based on Polymer Fiber Optic Interferometer
PublikacjaTemperature measurements are of great importance in many fields of human activities, including industry, technology, and science. For example, obtaining a certain temperature value or a sudden change in it can be the primary control marker of a chemical process. Fiber optic sensors have remarkable properties giving a broad range of applications. They enable continuous real-time temperature control in difficult-to-reach areas, in...
-
FIBRE-OPTIC SENSOR FOR SIMULTANEOUS MEASUREMENT OF THICKNESSAND REFRACTIVE INDEX OF LIQUID LAYERS
PublikacjaIn this paper, we present a fibre-optic sensor for simultaneous measurement of refractive index and thickness of liquid layers. We designed an experimental low-coherence setup with two broadband light sources and an extrinsic fibre-optic Fabry–Pérot interferometer acting as the sensing head. We examined how the refractive index of a liquid film and its thickness affect spectrum at the output of a fibre-optic interferometer. We...
-
Decomposing Cavities in Digital Volumes into Products of Cycles
Publikacja -
Improving the Survivability of Carrier Networks to Large-Scale Disasters
PublikacjaThis chapter is dedicated to the description of methods aiming to improve the survivability of carrier networks to large-scale disasters. First, a disaster classification and associated risk analysis is described, and the disaster-aware submarine fibre-optic cable deployment is addressed aiming to minimize the expected costs in case of natural disasters. Then, the chapter addresses the improvement of the network connectivity resilience...
-
Shock, unspecified - Male, 1 - Tissue image [3300730069414541]
Dane BadawczeThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Bisphenol A analogues and metabolic syndrome in women with polycystic ovary syndrome
PublikacjaBisphenols (BPs) have become a chemical group of special interest due to their ability to interfere with the endocrine system and their ubiquitous presence in the environment. As some of them possess mild estrogenic and anti-androgenic effects, they might be associated with the diagnosis of polycystic ovary syndrome (PCOS). Acting on multiple tissues, BPs exposure may lead to metabolic derangements characteristic for metabolic...
-
A Systematic Review for Establishing Relevant Environmental Parameters for Urban Lighting: Translating Research into Practice
PublikacjaThe application of lighting technologies developed in the 20th century has increased the brightness and changed the spectral composition of nocturnal night-time habitats and night skies across urban, peri-urban, rural, and pristine landscapes, and subsequently, researchers have observed the disturbance of biological rhythms of flora and fauna. To reduce these impacts, it is essential to translate relevant knowledge about the potential...
-
Thermal buckling of functionally graded piezomagnetic micro- and nanobeams presenting the flexomagnetic effect
PublikacjaGalerkin weighted residual method (GWRM) is applied and implemented to address the axial stability and bifurcation point of a functionally graded piezomagnetic structure containing flexomagneticity in a thermal environment. The continuum specimen involves an exponential mass distributed in a heterogeneous media with a constant square cross section. The physical neutral plane is investigated to postulate functionally graded material...
-
DETERMINATION OF SURFACTANTS IN ENVIRONMENTAL SAMPLES. PART II. ANIONIC COMPOUNDS
PublikacjaSurfactants (SAA) with negative charge of polar group are named as anionic compounds. They are main constituent of most products containing synthetic surfactants. The linear alkylbenzene sulfonates (LAS), alkyl ethoxysulfates (AES) and alkyl sulfates (AS) are typically applied from this class of compounds. Those surfactants are ingredients of household detergents and cleaners, laundry detergents, cosmetic. Moreover they can be...
-
Stability of thin film diamond mirror for applications in interferometers under the short-time exposure on selected aggressive chemicals
PublikacjaIn presented study a thin boron-doped diamond film was proposed for application in the interferometry as a highly durable optical mirror. The unique properties of the diamond films, like high chemical stability and hardness, allow them to be used even in the chemically aggressive environment, where the commonly used silver mirrors can be susceptible to damage. The investigated nanodiamond layer was fabricated by uPE CVD method...
-
A framework for risk assessment for maritime transportation systems—A case study for open sea collisions involving RoPax vessels
Publikacja -
Histological Features of Neovaginal Epithelium after Vaginoplasty in Mayer-Rokitansky-Küster-Hauser Syndrome
Publikacja -
Systematic review of the effect of D‑mannose with or without other drugs in the treatment of symptoms of urinary tract infections/cystitis (Review)
Publikacja -
Rectovesical ligament in didelphyc uterus: how frequent is it and what does it mean?
Publikacja -
Forty‐two normomenstruating adolescents with Müllerian obstructive anomalies: Presentation, pitfalls in the dagnosis and surgical management
Publikacja -
On robust FSO network dimensioning
Publikacja -
Shock, unspecified - Male, 1 - Tissue image [330073006941491]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobar pneumonia, unspecified - Female, 55 - Tissue image [9140730014133251]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobar pneumonia, unspecified - Female, 55 - Tissue image [9140730014131571]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Shock, unspecified - Male, 1 - Tissue image [3300730069414361]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other diseases of pericardium - Male, 0 - Tissue image [4050730010688491]
Dane BadawczeThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other diseases of pericardium - Male, 0 - Tissue image [4050730010686101]
Dane BadawczeThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other diseases of pericardium - Male, 0 - Tissue image [4050730010687711]
Dane BadawczeThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other diseases of pericardium - Male, 0 - Tissue image [4050730010687431]
Dane BadawczeThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Shock, unspecified - Male, 1 - Tissue image [330073006941881]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobar pneumonia, unspecified - Female, 55 - Tissue image [9140730014132971]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Shock, unspecified - Male, 1 - Tissue image [3300730069414831]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobar pneumonia, unspecified - Female, 55 - Tissue image [9140730014134581]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Shock, unspecified - Male, 1 - Tissue image [3300730069413911]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobar pneumonia, unspecified - Female, 55 - Tissue image [3300730069462541]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Other diseases of pericardium - Male, 0 - Tissue image [405073001068941]
Dane BadawczeThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobar pneumonia, unspecified - Female, 55 - Tissue image [9140730014138161]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobar pneumonia, unspecified - Female, 55 - Tissue image [9140730014136281]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Lobar pneumonia, unspecified - Female, 55 - Tissue image [9140730014134601]
Dane BadawczeThis is the histopathological image of BRONCHUS AND LUNG tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Elective design II Reinventing Gdańsk / Reinventing Gdynia
Kursy OnlineThe workshop will examine important modern architectural buildings in Gdańsk/ Gdynia in different political, cultural, economic and environmental contexts. The students will be divided into groups. Each group will be led by the curator of the exhibition. They will identify and evaluate the architectural values of the building through analyses, deconstructions and syntheses, focusing on understanding the basic principles of architecture...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 30 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 80 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 50 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 120 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 110 um (serie 2)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 1)
Dane BadawczeThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...