Filtry
wszystkich: 1721
wybranych: 425
Wyniki wyszukiwania dla: P25
-
Long-term measurement of physiological parameters - patient 4 (serie 5)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 4 (serie 19)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 15)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 1)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 6)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 3)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (4 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 4)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 12)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 23)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 17)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 10)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 22)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 20)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 16)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (8 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 7)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 14)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 21)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 18)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 13)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 11)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 19)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (3 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 5)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 6 (serie 8)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (10 hours) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 6 (serie 9)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Images of LEGO bricks
Dane BadawczeThe set contains images of LEGO bricks (from multiple categories). The images were prepared for training neural network for recognition and labeling of LEGO bricks. The images contain one brick each. The images were taken from different sides by handheld camera hovering over the bricks lying on a white, non reflective surface.
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen AMA1-MIC1-MIC3
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen MIC1-MIC3-ROP1
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Construction, production and evaluation of the diagnostic utility of a recombinant Toxoplasma gondii chimeric antigen AMA1-MIC1-ROP1
Dane BadawczeThe intracellular parasite Toxoplasma gondii has the ability to infect a wide range of warm-blooded animals, including humans. Currently, diagnosis of toxoplasmosis is based mainly on the use of the native antigens in enzyme immunoassay which allow for detection of IgG, IgM and IgA antibody classes. However, in some cases the performed studies give...
-
Short-term measurement of physiological parameters - teenager (30 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (25 minutes) measurements of physiological parameters were performed on the healthy...
-
Results of nanoindentation, XRD and microscopic studies of bacterial cellulose
Dane BadawczeThe archive contains the results of research on BNC bacterial biocellulose, which was modified in two ways. When BNC was synthesized, it was subjected to in situ modification involving the addition of hyuloronic acid to the bacterial medium. The second way of ex situ modification consisted of soaking the BNC in water and then convectionally drying it...
-
Physicochemical studies (Raman, XRD) of poly(lactic acid)-carbon black-nanodiamond composites
Dane BadawczeThis dataset contains physico-chemical examination of a new 3D printing-dedicated composites with poly-lactic acid (PLA), carbon black (CB) and nanodiamond fillers. Two types of nanodiamonds were studied: detonation nanodiamonds (DND) and boron-doped carbon nanowalls (BCNW). The investigated techniques include Raman spectroscopy and X-ray diffraction...
-
Rheology studies of poly(lactic acid)-carbon black-nanodiamond composites
Dane BadawczeThis dataset contains rheology measurements carried out on new 3D printing-dedicated composites with poly-lactic acid (PLA), carbon black (CB) and nanodiamond fillers. Two types of nanodiamonds were studied: detonation nanodiamonds (DND) and boron-doped carbon nanowalls (BCNW). The investigated techniques was performed by melt mass-flow rates (MFR)....
-
Mechanical studies of poly(lactic acid)-carbon black-nanodiamond composites
Dane BadawczeThis dataset contains mechanical tests carried out on new 3D printing-dedicated composites with poly-lactic acid (PLA), carbon black (CB) and nanodiamond fillers. Two types of nanodiamonds were studied: detonation nanodiamonds (DND) and boron-doped carbon nanowalls (BCNW). The investigated techniques was dynamic mechanical analysis (DMA). The measurements...
-
The topography of carbon black-polylactide composite 3D printed electrodes after femtosecond laser ablation
Dane BadawczeThis dataset contains a series of scanning electron microscopy images revealing the topography of 3D printed carbon black-polylactide composite electrodes after laser ablation with a femtosecond laser. Different laser powers were investigated, namely: 10%, 25%, 50%, 75% and 100%. The CB-PLA electrodes were 3D printed using an Ender printer. Femtosecond laser NKT Photonics, Origami XP parameters: power at 100%...
-
S14 2019 - video data - pedestrian, bicycles, vehicles
Dane BadawczeS14 2019 - video data - pedestrian, bicycles, vehicles
-
The surface of the sensor used in the analysis of odorous substances
Dane BadawczeHuman industrial activity usually leads to smaller or larger interference with the ecosystem, contributing to changes affecting the quality of life. An example may be the emission of gaseous substances, not necessarily toxic, but due to their intense smell, they can cause discomfort to people exposed to their inhalation. The problem is so important...
-
Nuts 61 (voj. kujawsko-pomorskie). Number of accidents, injuries, seriously Injured and fatalities
Dane BadawczeThe data contains information about the number of accidents, injuries, seriously Injured and fatalities between 1999 and 2019 in months in voj. kujawsko-pomorskie (Poland, nuts 61)
-
Nuts 42 (voj. zachodniopomorskie). Number of accidents, injuries, seriously Injured and fatalities
Dane BadawczeThe data contains information about the number of accidents, injuries, seriously Injured and fatalities between 1999 and 2019 in months in voj. zachodniopomorskie (Poland, nuts 42)
-
Nuts 63 (voj. pomorskie). Number of accidents, injuries, seriously Injured and fatalities
Dane BadawczeThe data contains information about the number of accidents, injuries, seriously Injured and fatalities between 1999 and 2019 in months in voj. pomorskie (Poland, nuts 63)
-
Au nanoparticles identifiction with the use of AFM Volta potential mapping
Dane BadawczeThe specific physical, chemical and electrochemical electrical properties of gold nanoparticles have led to their extensive use as high-performance chemical and biochemical sensors. The described properties relate to surface plasmon resonance, fluorescence quenching or enhancement, high electrical conductivity and light scattering. The described nanoparticles...
-
Nuts 41 (voj. wielkopolskie). Number of accidents, injuries, seriously Injured and fatalities
Dane BadawczeThe data contains information about the number of accidents, injuries, seriously Injured and fatalities between 1999 and 2019 in months in voj. wielkopolskie (Poland, nuts 41)
-
X-ray diffraction spectra of nitrogen-doped carbon in hybrid materials containing praseodymium oxide
Dane BadawczeX-ray powder diffraction patterns of samples were carried out by Philips X’Pert diffractometer, which was radiated by graphite monochromatized Cu Kα (l equal 1.540598). The operating voltage was maintained at 40 kV, the current was maintained at 30 mA and analyzed in the range from 20° to 90°. The data presented confirmed the presence of the PrBSCF...
-
Detection of UPEC IH11128 ability to form biofilm in a standard congo red (CR) method of colony staining.
Dane BadawczeA standard method of testing E. coli's ability to form biofilm is based on the analysis of morphologyof bacterial colonies grown on yeast extract/casamino acids (YESCA) nutrient agar medium containing congored (CR) as an indicator dye of ECM production. The CR dye adsorbed from the culture medium bybacteria binds to the components of the ECM, including...
-
The structure of lead-silicate glasses and nanocomposites doped with iron oxide
Dane BadawczeThe structure of iron-doped glasses and glass-ceramics were studied. Samples has the composition of 50SiO2–(50−x)PbO–xFe2O3, where x=15, 20 and 25 (in mol%). All samples were prepared by the conventional melt quenching technique; the melting was conducted in air at 1623 K in alumina crucibles. The melts were poured on a brass plate preheated to 573...
-
The morphology of lead-silicate glasses and nanocomposites doped with iron oxide
Dane BadawczeThe topography of iron-doped glasses and glass-ceramics were studied. Samples has the composition of 50SiO2–(50−x)PbO–xFe2O3, where x=15, 20 and 25 (in mol%). All sampleswere prepared by the conventional melt quenching technique; the melting was conducted in air at 1623 K in alumina crucibles. The melts were poured on a brass plate preheated to 573...
-
Top personal income tax rates (PIT) in EU countries (in%).
Dane BadawczeWhen analyzing the historical PIT rates, it should be noted that in 2000 the average rate was almost 45%. The highest income tax (approx. 60%) was imposed in Belgium, Denmark, as well as in the Netherlands and France. On the other hand, the lowest (25%) rates were recorded in Estonia and Latvia, which were not yet members of the European Union. In the...
-
Raman spectroscopy analysis of poly(lactic acid)-carbon black composite treated by femtosecond laser
Dane BadawczeThe dataset contains the Raman spectroscopy measurements of commercially available carbon black-filled poly(lactic acid) 3D printed electrodes after femtosecond laser ablation. These results were utilized in the manuscript published in Electrochimica Acta: 10.1016/j.electacta.2022.140288
-
The structure of lead-silicate glasses containing nanocrystallites of iron oxides
Dane BadawczeThe structure of iron-doped glasses and glass-ceramics were studied. Samples has the composition of (50 − 0.5x)SiO2–(50 − 0.5x)PbO–xFe2O3, where x = 2, 5, 10, 15, 20 and 25 (in mol%). All samples were prepared by the conventional melt quenching technique; the melting was conducted in air at 1623 K in alumina crucibles. The melts were poured on a brass...
-
The XPS studies of the CB-PLA electrodes after different surface treatments (chemical, electrochemical, enzymatic)
Dane BadawczeThe dataset contains the Xray Photoelectron Spectroscopy results of the studies performed under different conditions of surface activation of the CB-PLA 3D printed electrodes. The activation was performed by hydrolysis in different solvents (DMF, 1M HCl, 1M NaOH), electrolysis in 1M NaOH, enzymatic treatment in polymerase or simultaneous electrolysis...