Filtry
wszystkich: 585
wybranych: 372
-
Katalog
- Publikacje 372 wyników po odfiltrowaniu
- Czasopisma 10 wyników po odfiltrowaniu
- Osoby 16 wyników po odfiltrowaniu
- Wynalazki 10 wyników po odfiltrowaniu
- Projekty 11 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Kursy Online 12 wyników po odfiltrowaniu
- Wydarzenia 3 wyników po odfiltrowaniu
- Dane Badawcze 150 wyników po odfiltrowaniu
Filtry wybranego katalogu
Wyniki wyszukiwania dla: IMPLANTY POROWATE
-
Formation of Porous Structure of the Metallic Materials Used on Bone Implants
PublikacjaResearch on improvement of structure and fabrication methods of the bone implants are carried out for many years. Research are aimed to shape the structures, that will have a Young's modulus value similar to the value of the human bones Young's modulus. Depending on theporosity, Young's moduli can even be tailored to match the modulus of bone closer than solid metals can, thus reducing the problems associated with stress shielding...
-
Preparation of the porous biomaterial based on titanium alloy for orthopaedic implants
PublikacjaObecnie tytan i jego stopy (Ti-6Al-4V lub Ti-13Nb-13Zr) są szeroko stosowane jako biomateriały dla implantów ortopedycznych. Stale prowadzone są badania nad ich najlepszą odpornością na korozję i zużycie ścierne oraz biozgodnością i bioaktywnością. Obecne badania również skoncentrowane są na projektowaniu, wytwarzaniu i właściwościach materiałów porowatych na podstawie na przykład stopu tytanu (Ti-13Nb-13Zr), które mogą być stosowane...
-
Mechanical compatibility of implants used in hernia repair with abdominal wall
PublikacjaThe paper deals with a membrane model of a synthetic surgical mesh for treatment of abdominal hernia. The authors analyse the compatibility of two implant types with the human wall: Dualmesh Gore and Proceed. The finite element method is applied to simulate tjhe behavior of the proposed model. Due fact that recurrences are usually caused by connection failure, this study is focused on reaction forces in supports representing the...
-
The allergic and irritating reactions to metallic implants with trauma - orthopaedic patients
PublikacjaThe article presents the analysis of clinical operation complications after the treatment of long bones by mean of ostheosynthesis with the use of metal implants and endoprothesoplastic of hip joints.
-
Biological and mechanical research of titanium implants covered with bactericidal coating
PublikacjaThe paper concerns the biological and mechanical properties of titanium implants with an antibacterial coating. The Ti13Zr13Nb alloy samples were coated with hydroxyapatite (HAp) coatings using the electrophoretic deposition technique (EPD). Subsequently, the surface of the samples was modified with silver, copper, and nickel nanoparticles by the immersion method. Different titanium sample types (i.e. HAp-only and nanometals-enriched...
-
Processing of porous structures of YBa2Cu3O7-δ High-temperature superconductor
PublikacjaPublikacja opisuje technikę otrzymywania nadprzewodnika wysokotemperaturowego YBa2Cu3O7-x o porach otwartych.
-
Investigation on Filaments for 3D Printing of Nasal Septum Cartilage Implant
PublikacjaSeptoplasty is a widely used method in treating deviated septum. Although it is successfully implemented, there are problems with excessive bleeding, septal perforation, or infections. The use of anatomically shaped implants could help overcome these problems. This paper focuses on assessing the possibility of the usage of a nasal septum cartilage implant 3D printed from various market-available filaments. Five different types...
-
Mechanical model of fascia-implant structure. Finite element simulation.
PublikacjaPraca dotyczy modelowania i symulacji syntetycznych implantów chirurgicznych stosowanych w leczeniu przepulin brzusznych metodą laparoskowpową. Prponowane są modele matematyczne a ich prawidłowość weryfikowana jest na podstawie badań doświadczalnych zachowania się modeli fizycznych wszczepionych implantów pod wpływem obciążeń wynikających z fizjologii człowieka. Nakreślona jest metodologia oceny trwałości połączenia siatki chirurgicznej...
-
Mathematical modelling of implant in an operated hernia for estimation of the repair persistence
PublikacjaThis paper presents mathematical modelling of an implanted surgical mesh used in the repair process of the abdominal hernia. The synthetic implant is simulated by a membrane structure. The author provides a material modelling of the implant based on the dense net model appropriate for technical fabrics. The accuracy of the proposed solution is evaluated by comparing the simulations of the dynamic behaviour of the system with the...
-
Trudności podczas modelowania próby implant w programie Ansys.
PublikacjaW artykule przedstawiono trudności związane ze stworzeniem modelu próby implant w programie Ansys. Określono również trudności związane z przypisaniem odpowiednim strefom połączenia spawanego własności mechanicznych.
-
Physical and mathematical modelling of implant-fascia system in order to improve laparoscopic repair of ventral hernia
PublikacjaThis paper describes an investigation of biomechanical behaviour of hernia repair, which is focused on the selection of safe linking of certain type of implant with fascia in laparoscopic operation. The strength of various fixations of the implant to the fascia is analysed. Methods: The research is based on experimental observations of operated hernia model behaviour during a dynamic impulse load corresponding to post-operative...
-
Tlenkowe ogniwa paliwowe zbudowane na nośnym elemencie z metalowego porowatego interkonektora
PublikacjaW pracy przedtawiony stan rozwoju tlenkowych ogniw paliwowych zbudowanych na nośnym elemencie z metalowego porowatego interkonektora.
-
Modeling the debonding process of osseointegrated implants due to coupled adhesion and friction
PublikacjaCementless implants have become widely used for total hip replacement surgery. The long-term stability of these implants is achieved by bone growing around and into the rough surface of the implant, a process called osseointegration. However, debonding of the bone–implant interface can still occur due to aseptic implant loosening and insufficient osseointegration, which may have dramatic consequences. The aim of this work is to...
-
Debonding of coin-shaped osseointegrated implants: Coupling of experimental and numerical approaches
PublikacjaWhile cementless implants are now widely used clinically, implant debonding still occur and is difficult to anticipate. Assessing the biomechanical strength of the bone–implant interface can help improving the understanding of osseointegration phenomena and thus preventing surgical failures. A dedicated and standardized implant model was considered. The samples were tested using a mode III cleavage device to assess the mechanical...
-
The bahaviour of selected silver coated body implants in presence of various bacteria
PublikacjaThe article deals with implants covered with silver nanoparticles and its influence on bacteria adhesion.
-
Are Titania Photocatalysts and Titanium Implants Safe? Review on the Toxicity of Titanium Compounds
Publikacja -
Nanotubular Oxide Layer Formed on Helix Surfaces of Dental Screw Implants
PublikacjaSurface modification is used to extend the life of implants. To increase the corrosion resistance and improve the biocompatibility of metal implant materials, oxidation of the Ti-13Nb- 13Zr titanium alloy was used. The samples used for the research had the shape of a helix with a metric thread, with their geometry imitating a dental implant. The oxide layer was produced by a standard electrochemical method in an environment of...
-
Comprehensive Evaluation of the Biological Properties of Surface-Modified Titanium Alloy Implants
PublikacjaAn increasing interest in the fabrication of implants made of titanium and its alloys results from their capacity to be integrated into the bone system. This integration is facilitated by different modifications of the implant surface. Here, we assessed the bioactivity of amorphous titania nanoporous and nanotubular coatings (TNTs), produced by electrochemical oxidation of Ti6Al4V orthopedic implants’ surface. The chemical composition...
-
Evaluation of porous 430L stainless steel for SOFC operation at intermediate temperatures
PublikacjaW pracy przedstawiono badania porowatej stali nierdzewnej typu 430L do zastosowań w tlenkowych ogniwach paliwowych jako podłoża. Podłoża były poddawane utlenianiu w powietrzu oraz w wodorze i analizowane z wykorzystaniem mikroskopu elektronowego, dyfrakcji rentgenowskiej i termograwimetrii cyklicznej.
-
Materiały stosowane do wytwarzania implantów kości
PublikacjaMateriały stosowane do wytwarzania implantów kostnych muszą być biokompatybilne, nietoksyczne, bioaktywne oraz wykazywać odpowiednie właściwości mechaniczne, takie jak wytrzymałość na ściskanie, na zginanie oraz sztywność i twardość. Gama stosowanych materiałów jest bardzo szeroka, obejmuje metale, polimery, ceramikę oraz ich kompozyty. Każdy z tych materiałów ma swoje mocne i słabe strony. Praca stanowi przegląd materiałów stosowanych...
-
Nanotubular Titanium Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublikacjaThe present paper describes the techniques to improve the bioactivity of titanium and enhance the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotube arrays (TiO2).
-
Dynamics of mechanical model of implant-tissue system in ventral hernia repair
PublikacjaThe paper deals with a finite element modelling of implants in the problem of ventral hernia repair. The synthetic mesh implanted in the abdomen during surgery is here modelled as a membrane structure. Thesystem undergoes the internal abdominal pressure that occurs during the postoperative cough, the load identified in the literature as the main cause of the connection failure and hernia recurrence. The model can be used to estimate...
-
IMPLANT USED IN HERNIA REPAIR UNDER PHYSIOLOGICAL MOVEMENTS OF HUMAN ABDOMEN
PublikacjaThe study deals with the mechanical behaviour of implant used in repair of abdominal hernia. The influence of orientation of the orthotropic implants in different areas of abdominal wall is studied.
-
Orthotropic membrane as a mechanical model of surgical implant in abdominal hernia repair
PublikacjaEven though the incisional hernia repair surgery is a well known procedure, mechanical properties of the tissue-implant system are unknown so the implantation of the repairing mesh is quite intuitive and, recurrences of the illness still take place. The main objective of the study is to define an operated hernia model that can be used for surgery planning and the assessment of the repair persistence. The load applied to the structure...
-
Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublikacjaAbstrakt artykułu pt. ''Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity''. The paper describes techniques to improve the bioactivity of titanium and ehnahnce the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotubular oxide layer.
-
Mathematical approach to design 3D scaffolds for the 3D printable bone implant
PublikacjaThis work demonstrates that an artificial scaffold structure can be designed to exhibit mechanical properties close to the ones of real bone tissue, thus highly reducing the stress-shielding phenomenon. In this study the scan of lumbar vertebra fragment was reproduced to create a numerical 3D model (this model was called the reference bone sample). New nine 3D scaffold samples were designed and their numerical models were created....
-
Boronate-appended polymers with diol-functionalized ferrocene: an effective and selective method for voltammetric glucose sensing
Publikacja -
Allergic Reactions as a Defense of the Organism to the Influence of Implants Components Made of Stainless Steel
PublikacjaDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Electro-optical system for the automated selection of dental implants according to their colour matching
Publikacja -
Allergic reactions as a defense of the organism to the influence of implants components made of stainless steel
PublikacjaDue to the increasing number of cases of hypersensitivity caused by direct contact with metals, as well as the increasing demand for implants in humans all ages numerous studies on the effects of the impact of implant components are being carried out. The paper presents the phenomenon of etiology of allergy in general terms and in relation to the biomaterials used in medicine. There have been characterized in terms of impact on...
-
Influence of Surface Modification of Titanium and Its Alloys for Medical Implants on Their Corrosion Behavior
PublikacjaTitanium and its alloys are often used for long-term implants after their surface treatment. Such surface modification is usually performed to improve biological properties but seldom to increase corrosion resistance. This paper presents research results performed on such metallic materials modified by a variety of techniques: direct voltage anodic oxidation in the presence of fluorides, micro-arc oxidation (MAO), pulse laser treatment,...
-
Constitutive Modelling of Knitted Abdominal Implants in Numerical Simulations of Repaired Hernia Mechanics
PublikacjaThe paper presents a numerical approach to describe mechanical behavior of anisotropic textile material, which is a selected abdominal prosthesis. Two constitutive nonlinear concepts are compared. In the first one the material is considered composed from two families of threads (dense net model) and in the second one the material is homogeneous but anisotropic (as proposed by Gassel, Ogden, Holzapfel). Parameters of both models...
-
Surface treatment of porous Ti13Nb13Zr alloy for biomedical applications
PublikacjaPrzeprowadzono badania materiału porowatego, przeznaczonego na implanty ortopedyczne, wytworzonego metodą metalurgii proszków ze stopu Ti13Nb13Zr. Proszki z badanego stopu uzyskano metodą rozpylania plazmowego. Otrzymano próbki o otwartej porowatej strukturze, stopniu porowatości do 68% i średniej wielkości porów w przedziale 30-150 mikrometrów. Obróbka próbek porowatych - utlenianie termiczne, chemiczne i/lub elektrochemiczne...
-
Identification of the damage mechanism in orthopaedic implant. Case study including the biomechanical analysis
Publikacja -
A PRELIMINARY STUDY ON THE OPTIMAL CHOICE OF AN IMPLANT AND ITS ORIENTATION IN VENTRAL HERNIA REPAIR
PublikacjaThis paper addresses the problem of ventral hernia repair. The main goals are to find an optimal surgical mesh for hernia repair and to define its optimal orientation in the abdominal wall to minimise the maximum force at the tissue-implant juncture. The optimal mesh is chosen from a set of orthotropic meshes with different stiffness ratios for typical hernia placement in the abdominal area. The implant is subjected to an anisotropic...
-
Mechanical behaviour of the implant used in human hernia repair under physiological loads
PublikacjaIn laparoscopic operations of abdominal hernias some recurrences still take place, even when applying a surgical mesh. This is usually caused by a failure of the connection between the tissue and the implant. The study deals with the influence of an implant’s orientation on forces in joints, which connect the mesh to human tissues. In the paper, the implant is modelled as a membrane structure within framework of the Finite Element...
-
Mathematical study of a tissue-implant connection in a ventral herniarepair in a context of the system's parameters
PublikacjaW pracy przedstawiono problem operowania przepuklin brzusznych u ludzi. Zaproponowano jednowymiarowy model układu powieź-implant. Na podstawie analizy wrażliwości zidentyfikowano najważniejsze parametry problemu.
-
PODATNOŚĆ IMPLANTÓW KARDIOLOGICZNYCH NA BIODEGRADACJĘ – PRZEGLĄD LITERATURY
PublikacjaDo implantów kardiologicznych należą sztuczne zastawki serca, naczynia krwionośne oraz stenty naczyniowe i stymulatory serca. Wszczepy te umieszcza się w miejscu nieprawidłowo działającego elementu w celu poprawy stanu zdrowia i jakości życia pacjenta. Prawidłowe funkcjonowanie implantów może zostać zaburzone przez biodegradację, która nie jest efektem jednego procesu, lecz skutkiem synergicznego działania wielu czynników natury...
-
Obiektywna metoda wyznaczania skuteczności systemów implantów ślimakowych
PublikacjaPrzedmiotem pracy było opracowanie nowej metody wyznaczania skuteczności systemów implantów ślimakowych opartej o komputerowe symulacje słyszenia elektrycznego.
-
Determinants of the primary stability of cementless acetabular cup implants: A 3D finite element study
PublikacjaPrimary stability of cementless implants is crucial for the surgical success and long–term stability. However, primary stability is difficult to quantify in vivo and the biomechanical phenomena occurring during the press–fit insertion of an acetabular cup (AC) implant are still poorly understood. The aim of this study is to investigate the influence of the cortical and trabecular bone Young's moduli Ec and Et, the interference...
-
Porewater dissolved organic and inorganic carbon in relation to methane occurrence in sediments of the Gdańsk Basin (southern Baltic Sea)
Publikacja -
Design of a D3h-symmetry prismatic tris-(ferrocene-1,1′-diyl) molecular cage bearing boronate ester linkages
Publikacja -
Surgical implant used in ventral hernia repair subjected to physiological pressure - computer simulation
PublikacjaW streszczeniu przedstawiono matemayczny model implantu wszczepionego pacjentowi podczas laparoskopowej naprawy przepukliny brzusznej. Wykonano go z użyciem metody elementów skończonych. Przyjęto ortotropowy model materiałowy implantu.
-
Assessment of the usefulness of bacterial cellulose produced by Gluconacetobacter xylinus E25 as a new biological implant
PublikacjaBionanocellulose (BNC) is a clear polymer produced by the bacterium Gluconacetobacter xylinus. In our current study, “Research on the use of bacterial nanocellulose (BNC) in regenerative medicine as a function of the biological implants in cardiac and vascular surgery”, we carried out material analysis, biochemical analysis, in vitro tests and in vivo animal model testing. In stage 1 of the project, we carried out physical and...
-
Rozwój bioaktywnych implantów porowatych na osnowie stopów tytanu
PublikacjaGłównym przedmiotem pracy są złożone zagadnienia materiałowe wynikajace ze specyfiki zastosowań implantów wytworzonych z tytanu i jego stopów, szczególnie w zakresie bioaktywności i stabilności długoczasowej implantów tkanki kostnej w obszarach przenoszących znaczne obciążenia. Dokonano krytycznej analizy obecnego stanu wiedzy w tym zakresie i przedstawiono wyniki prac własnych prowadzonych prowadzonych na Politechnice Gdańskiej,...
-
In Vitro and Ex Vivo Chemical Stability Studies of Layers on Substrates and Implants Made of Titanium Alloy
Publikacja -
Biological effect of hydrothermally synthesized silica nanoparticles within crystalline hydroxyapatite coatings for titanium implants
Publikacja -
Composites of polylactide and nano-hydroxyapatite created by cryomilling and warm isostatic pressing for bone implants applications
Publikacja -
Development and biological evaluation of Ti6Al7Nb scaffold implants coated with gentamycin-saturated bacterial cellulose biomaterial
Publikacja -
Studies on Silver Ions Releasing Processes and Mechanical Properties of Surface-Modified Titanium Alloy Implants
PublikacjaDispersed silver nanoparticles (AgNPs) on the surface of titanium alloy (Ti6Al4V) and titanium alloy modified by titania nanotube layer (Ti6Al4V/TNT) substrates were produced by the chemical vapor deposition method (CVD) using a novel precursor of the formula [Ag5(O2CC2F5)5(H2O)3]. The structure and volatile properties of this compound were determined using single crystal X-ray diffractometry, variable temperature IR spectrophotometry...