Induced sheath voltages in 110 kV power cables – case study
PublikacjaThis paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse...
-
Evaluation of bearing and journal damage in MAN 9L40-54 engines installed on M/V STENA SCANDINAVICA ferry
PublikacjaThe following report was requested by Remontowa Shiprepair Yard (RSY) S.A. in Gdansk ´ (contract no. 4/2018/EX/U, dated 13.02.2018) and prepared based on the materials received from RSY, two on-board inspections and the participation of the contractors in three conferences with RSY representativesi. The goal of the analysis performed by the experts of Gdansk University of Technology was ´ to determine the character of the bearing...
-
Resonance problems in UHV transmission lines
PublikacjaThe paper presents resonance phenomena observed in 400 kV transmission lines in the Polish power system. Two events are analysed, when shunt reactors used for reactive power compensation, caused overvoltages and overcurrent protection tripping as a result of resonance. An oscillographic fault recordings from protection devices are compared to time domain simulation results. The obtained simulation results match fault recordings,...
-
Neutral earthing reactor protection
PublikacjaThe IEEE and CIGRE recommend protection systems for high voltage shunt reactors. Unfortunately the recommendations do not include guidelines for the protection of neutral earthing reactors, which are often connected to shunt reactors to increase the effectiveness of single pole auto-reclosing. The paper discusses earthing reactor protection issues with particular emphasis on the detection of internal faults. An analysis carried...
-
Low-frequency tripping characteristics of residual current devices
PublikacjaFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublikacjaPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Wpływ warunków otoczenia na obciążalność prądową długotrwałą kabli elektroenergetycznych
PublikacjaObciążalność prądowa długotrwała przewodów i kabli elektroenergetycznych zależy m.in. od sposobu ich ułożenia i warunków otoczenia. Kabel elektroenergetyczny ułożony w zmiennych warunkach, np. ziemia – woda – powietrze ma obciążalność prądową długotrwałą wynikającą z najgorszych warunków otoczenia pod względem oddawania ciepła. W artykule zaprezentowano wyniki badań symulacyjnych dla linii kablowej niskiego napięcia umieszczonej...
-
Analiza napięć indukowanych w żyłach powrotnych kabli wysokiego napięcia w wybranych konfiguracjach ich ułożenia
PublikacjaW żyłach powrotnych kabli wysokiego napięcia mogą indukować się znaczne napięcia względem ziemi przy przepływie prądów roboczych oraz prądów zwarciowych, co zagraża porażeniem i/lub uszkodzeniem zewnętrznej powłoki kabla. Wartości tych napięć zależą od sposobu ułożenia i długości kabli, sposobu uziemienia ich żył powrotnych, wartości prądu w żyłach roboczych, a także transpozycji żył roboczych i powrotnych. W artykule przedstawiono...
-
Impact of R/X ratio of distribution network on selection and control of energy storage units
PublikacjaThe interest in energy storage is still increasing. Energy storage units are installed in high voltage networks, medium voltage networks and low voltage distribution networks as well. These units are often used to improve power quality. One of the criteria for improving power quality is reducing voltage deviations. Depending on the type of network and specifying its R/X ratio, this criterion can be fulfilled by control of active...
-
Protection of Earthing Reactor Connected to the Star Point of a High Voltage Shunt Reactor
PublikacjaThe article presents the problem of protection of earthing reactors connected to the star point of shunt reactors in high voltage lines, with particular regard to the detection of internal faults. Model analyses for an actual system commissioned in 2015, which is intended to be provided with earthing reactors, are included.
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublikacjaIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
A New Method of the Load Compensation Use During Creation of Post Blackout Start-up Path in Power System
PublikacjaIn the paper a new method of effective use of load compensation during creation of post blackout start-up path is proposed. Theoretical assumptions and simulation results of an investigation are presented. An experiment performed in the Polish Power System is also described. This experiment proved that the method proposed by the authors is advisable. The method may be utilized by power system operators for power system restoration...
-
Zabezpieczanie dławika uziemiającego przyłączonego do punktu gwiazdowego dławika kompensacyjnego wysokiego napięcia
PublikacjaW artykule przedstawiono problematykę zabezpieczania dławików uziemiających przyłączanych do punktu gwiazdowego dławików kompensacyjnych stosowanych w liniach wysokiego napięcia, ze szczególnym uwzględnieniem detekcji zwarć wewnętrznych. Załączono analizy modelowe dla rzeczywistego układu oddanego do pracy w 2015 roku, który docelowo ma zostać doposażony w dławiki uziemiające.
-
Analiza napięć indukowanych i strat mocy w kablach elektroenergetycznych wysokiego napięcia dla wybranych sposobów uziemienia żył powrotnych
PublikacjaDostarczanie mocy do centrów miast coraz częściej odbywa się z wykorzystaniem linii kablowych o napięciu 110 kV. To dogodny sposób zasilania, a praktycznie jedyny możliwy w przypadku gęstej zabudowy miejskiej. Kable wysokiego napięcia zawierają współosiową żyłę powrotną, w której podczas normalnej pracy oraz w stanach zakłóceniowych (podczas zwarć) mogą indukować się znaczne napięcia względem ziemi, co zagraża porażeniem i/lub...
-
Analiza napięć indukowanych w żyłach powrotnych kabli wysokiego napięcia dla ich wybranych konfiguracji
PublikacjaW żyłach powrotnych kabli wysokiego napięcia mogą indukować się znaczne napięcia względem ziemi przy przepływie prądów roboczych oraz prądów zwarciowych, co zagraża porażeniem i/lub uszkodzeniem zewnętrznej powłoki kabla. Wartości tych napięć zależą od sposobu ułożenia i długości kabli, sposobu uziemienia ich żył powrotnych, wartości prądu w żyłach roboczych, a także transpozycji żył roboczych i powrotnych. W artykule przedstawiono...
-
Wybrane problemy detekcji zakłóceń w dławiku uziemiającym przyłączonym do punktu gwiazdowego dławika kompensacyjnego
PublikacjaW referacie przedstawiono problematykę zabezpieczania dławików uziemiających przyłączanych do punktu gwiazdowego dławików kompensacyjnych stosowanych w liniach wysokiego napięcia, ze szczególnym uwzględnieniem detekcji zwarć wewnętrznych. Przedstawiono analizy modelowe dla rzeczywistego układu oddanego do pracy w 2015, który docelowo ma zostać doposażony w dławiki uziemiające.
-
Evaluation of fire hazard in electrical installations due to unfavorable ambient thermal conditions
PublikacjaEvaluation of fire hazard caused by electrical installations is a difficult and important topic, and it limits the possibility of loss of life or health of people, as well as the occurrence of significant property damage. In particular, this hazard was caused by power cables and especially photovoltaic (PV) installations. The authors proved that power cables directly exposed to strong solar radiation are likely to exceed maximum...
-
Synthesis of bimetallic Co–Pt/cellulose nanocomposites for catalytic reduction of p-nitrophenol
PublikacjaIn this study, bimetallic nanoparticles (NPs) of Co–Pt anchored on cellulose nanofibers (CNFs) for catalytic applications were synthesized via a sonochemical approach. The electro-spinning technique was employed for the synthesis of CNFs from cellulose acetate. The thorough characterization of synthesised Co–Pt/CNF nanocomposites was performed with the help of scanning electron microscopy (SEM), Fourier transform infra-red (FT-IR)...
-
Informal Settlements and International Migrants: The city of Rome (Italy) as Case Study
PublikacjaToday, urbanization is happening at an unprecedentedly rapid rate, owing heavily to the influx of migrants. Empirical evidence shows the development of informal settlements in cities as a result of migration, including Rome. Furthermore, information on informal settlements is either insufficient or inadequate, which makes it challenging for architects, urban planners, and policymakers to form viable solutions to deal with the situations...
-
Restrained differential of a graph
PublikacjaGiven a graph $G=(V(G), E(G))$ and a vertex $v\in V(G)$, the {open neighbourhood} of $v$ is defined to be $N(v)=\{u\in V(G) :\, uv\in E(G)\}$. The {external neighbourhood} of a set $S\subseteq V(G)$ is defined as $S_e=\left(\cup_{v\in S}N(v)\right)\setminus S$, while the \emph{restrained external neighbourhood} of $S$ is defined as $S_r=\{v\in S_e : N(v)\cap S_e\neq \varnothing\}$. The restrained differential of a graph $G$ is...
-
Telomere uncapping by common oxidative guanine lesions: Insights from atomistic models
PublikacjaOxidative damage to DNA is widely known to contribute to aging and disease. This relationship has been extensively studied for telomeres – structures that cap chromosome ends – due to their role in cell proliferation and senescence, and exceptional susceptibility to oxidation. Indeed, the repetitive telomeric DNA sequence contains the 5′-GGG-3′ motif that has the lowest ionization potential of all trinucleotides. Accordingly, experiments...
-
A mechanistically approached review upon assorted cell lines stimulated by athermal electromagnetic irradiation
PublikacjaThe probable influence of electromagnetic irradiation on cancer treatment has been deduced from the interaction of artificial electromagnetic emissions with biological organisms. Nonetheless, the suspected health effects induced by electromagnetic-based technology imply that such a treatment may contaminate the adjacent healthy cells. Thus, gaining mechanistic insights into the problem is required to avoid athermal health hazards....
-
Novel anticancer strategy aimed at targeting shelterin complexes by the induction of structural changes in telomeric DNA: hitting two birds with one stone.
PublikacjaThe ends of chromosomes in mammals are composed of telomeric DNA containing TTAGGG repeats, which bind specific proteins called shelterins. This telomeric DNA together with shelterins form a cap that protects the ends of chromosomes from being recognized as sites of DNA damage and from chromosomal fusions. Many very successful antitumor drugs used in the treatment of cancer patients bind to DNA, some of them with a prominent sequence...
-
DC and AC Conductivity, Biosolubility and Thermal Properties of Mg-Doped Na2O–CaO–P2O5 Glasses
PublikacjaBioactive glasses have recently been extensively used to replace, regenerate, and repair hard tissues in the human body because of their ability to bond with living tissue. In this work, the effects of replacing Na2O with MgO on the electrical, biosolubility, and thermal properties of the target glass 10Na2O–60P2O5–30CaO (in mol%) were investigated. The electrical properties of the glasses were studied with the impedance spectroscopy...
-
Modelling long-term technological transition of Polish power system using MARKAL: Emission trade impact
PublikacjaThe need for technological transition of electricity production becomes a global problem. However, in coal-dominated Polish power system this need is even more crucial than anywhere, since technical lifetime of the most domestic power plants is ending. In this paper, the impact of the EU Emission Trading Scheme (EU ETS) for CO2 combined with sulfur dioxide (SO2) and nitrogen oxides (NOx) emission trading mechanism on power technology...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Estimation of the Maximum Permissible PV Power to be Connected to the MV Grid
PublikacjaIn recent decades, a significant increase in the share of renewable energy sources in power grids at various voltage levels has been observed. A number of articles have been published highlighting emerging problems in low-voltage grids with a large share of prosumers and in medium- and high-voltage grids to which photovoltaic (PV) plants are connected. The article analyzes the medium-voltage grid in terms of the possibility of...
-
Study of Soil Temperature and Moisture Changes in a Physical Model of an Underground Cable Line
PublikacjaThe ampacity of power cables is highly dependent on the thermal resistivity of the soil in which they are laid. The lower it is, the higher this ampacity. The thermal resistivity of the soil decreases as its moisture increases. Therefore, it is preferable that the soil around the cables has high moisture. Unfortunately, the heat generated in heavily loaded cables causes the migration of moisture from the surrounding soil, which...
-
Availability of UAV Fleet Evaluation Based on Multi-State System
PublikacjaUnmanned Aerial Vehicle (UAV) applications are extended extremely. Some applications need to use several UAVs for a general mission which can be considered a UAV fleet. One of the important characteristics for the evaluation of a UAV or UAV fleet is reliability. There are studies in which methods for analysis of their reliability are considered. Reliability analysis of UAV fleets is less frequently studied, although a single UAV...
-
Integrated algorithm for selecting the location and control of energy storage units to improve the voltage level in distribution grids
PublikacjaThis paper refers to the issue that mainly appears in distribution grids, where renewable energy sources (RES) are widely installed. In such grids, one of the main problems is the coordination of energy production time with demand time, especially if photovoltaic energy sources are present. To face this problem, battery energy storage units (ESU) can be installed. In recent years, more and more attention has been paid to optimizing...
-
Wykorzystanie logiki rozmytej do regulacji napięcia w systemie elektroenergetycznym z wybranymi odnawialnymi źródłami energii
PublikacjaW ostatnich latach w krajowym systemie elektroenergetycznym liczba i moc odnawialnych źródeł energii znacząco wzrosły. Źródła te można wykorzystać nie tylko do produkcji tzw. czystej energii elektrycznej, ale również do poprawy warunków napięciowych w tym systemie. W artykule przedstawiono koncepcję układu regulacji napięcia w systemie elektroenergetycznym z przyłączonymi w pewnym obszarze: farmą wiatrową, farmą fotowoltaiczną,...
-
Voltage control in a power system with renewable sources of energy
PublikacjaIntensive development of distributed generation in power systems, caused by the European Union energy policy, gives possibility for improving safety in power delivery as well as optimizing the costs of the systems functioning. In this context, distributed generation can be used for voltage control in power systems – it can be performed by the control of reactive power of each source of energy or a group of energy sources. This...
-
Analiza wpływu wybranych odnawialnych źródeł energii na straty mocy czynnej i biernej w systemie elektroenergetycznym
PublikacjaMoc zainstalowana oraz produkcja energii elektrycznej z odnawialnych źródeł energii od kilkunastu lat systematycznie w Polsce wzrasta. Należy spodziewać się, że tendencja ta w najbliższych latach zostanie utrzymana. Dość dużym zainteresowaniem cieszą się źródła wiatrowe oraz źródła fotowoltaiczne, co sprawia, że przy znacznych ich mocach zainstalowanych konieczne staje się badanie wpływu tych źródeł na system elektroenergetyczny....
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Higher harmonics produced by traction substations – computer modelling and experimental verification
PublikacjaVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers, although the rms value of load current does not exceed their current-carrying capacity. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion...
-
WPŁYW GENERACJI ROZPROSZONEJ NA STRATY MOCY CZYNNEJ W SIECIACH DYSTRYBUCYJNYCH WN I SN
PublikacjaW referacie przedstawiono wpływ lokalizacji generacji rozproszonej na pracę sieci dystrybucyjnej WN i SN. W przypadku sieci SN rozpatrzono przypadki lokalizacji źródła blisko GPZ oraz w głębi sieci z uwzględnieniem jej topologii: sieć promieniowa oraz dwustronnie zasilana. Rozpatrzono również aspekty wpływu źródeł na rozpływy mocy, straty mocy, poziomy napięć oraz pracę regulatora transformatora w GPZ. W przypadku sieci WN przeanalizowano...
-
Harmonics produced by traction substations – computer modelling and experimental verification
PublikacjaVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion include traction rectifiers. This paper presents results of the computer investigation of...
-
Energy Efficiency and Economic Policy: Comprehensive Theoretical, Empirical, and Policy Review
PublikacjaIn this paper, we analyze the role of economic policy in prompting energy efficiency. This study reviews three aspects, theoretical, empirical, and existing policies to evaluate the relationship of energy efficiency and economic policy. This study furthermore identifies the existing issues from a policy perspective in energy efficiency. Although not all public policies may be justified, it suggests that these types of financial...
-
Fire-Retardant Flexible Foamed Polyurethane (PU)-Based Composites: Armed and Charmed Ground Tire Rubber (GTR) Particles
PublikacjaInadequate fire resistance of polymers raises questions about their advanced applications. Flexible polyurethane (PU) foams have myriad applications but inherently suffer from very high flammability. Because of the dependency of the ultimate properties (mechanical and damping performance) of PU foams on their cellular structure, reinforcement of PU with additives brings about further concerns. Though they are highly flammable and...
-
DEPO: A dynamic energy‐performance optimizer tool for automatic power capping for energy efficient high‐performance computing
PublikacjaIn the article we propose an automatic power capping software tool DEPO that allows one to perform runtime optimization of performance and energy related metrics. For an assumed application model with an initialization phase followed by a running phase with uniform compute and memory intensity, the tool performs automatic tuning engaging one of the two exploration algorithms—linear search (LS) and golden section search (GSS), finds...
-
Modeling external carbon addition in combined N-P activated sludge systems with an extension of the IWA Activated Sludge Models
PublikacjaThe aim of this study was to expand the IWA Activated Sludge Model No. 2d (ASM2d) to account for a newly defined readily biodegradable substrate that can be consumed by polyphosphate accumulating organisms (PAOs) under anoxic and aerobic conditions, but not under anaerobic conditions. The model change was to add a new substrate component and process terms for its use by PAOs and other heterotrophic bacteria under anoxic and aerobic...
-
The influence of food phytochemicals on cyclic phosphodiesterase 4 (PDE4) activity
PublikacjaCyclic phosphodiesterase 4 (PDE4) belongs to family of cyclic phosphodiesterases, which are expressed predominantly in inflammatory cells, airway smooth muscles, cardiovascular tissues and brain. Inhibitors of this family of enzymes found medicinal applications as antidepressants, antiinflamatory drugs (mainly in airway diseases) or antiasthmatics (Ibudilast). PDE4 inhibitors are also being tested for preventing the development...
-
Modeling external carbon addition in combined N-P activated sludge systems with an extension of the IWA Activated Sludge Models
PublikacjaThe aim of this study was to expand the IWA Activated Sludge Model No. 2d (ASM2d) to account for a newly defined readily biodegradable substrate that can be consumed by polyphosphate accumulating organisms (PAOs) under anoxic and aerobic conditions, but not under anaerobic conditions. The model change was to add a new substrate component and process terms for its use by PAOs and other heterotrophic bacteria under anoxic and aerobic...
-
Dual-Activity Fluoroquinolone-Transportan 10 Conjugates offer alternative Leukemia therapy during Hematopoietic Cell Transplantation
PublikacjaHematopoietic cell transplantation (HCT) is often considered a last resort leukemia treatment, fraught with limited success due to microbial infections, a leading cause of mortality in leukemia patients. To address this critical issue, we explored a novel approach by synthesizing antileukemic agents containing antibacterial substances. This innovative strategy involves conjugating fluoroquinolone antibiotics, such as ciprofloxacin...
-
Layer-by-layer polymer deposited fabrics with superior flame retardancy and electrical conductivity
PublikacjaSmart and multifunctional textiles and fabrics are progressively developing, such that multifunctional fabrics are becoming more widespread. We elaborated herein multi-layered flax fabrics with superior flame retardancy and conductivity, which revealed fireproof feature while keeping conductivity during burning. The flax fabric was reinforced by layer-by-layer (LbL) deposition of sodium polyacrylate (SPA), polyethylenimine (PEI),...
-
The effect of road restraint systems on the level of road safety - Polish experience
PublikacjaRoadside accidents happen when a vehicle runs off the road. The majority of these accidents are very severe because leaving the road is usually followed by hitting a solid obstacle (tree, pole, support, culvert front wall, barrier). Roadsides are some of the most important issues of road safety. They have been studied for years to identify roadside hazards and the effectiveness of road safety measures such as restraint systems....
-
Crystalline Silicon (c-Si)-Based Tunnel Oxide Passivated Contact (TOPCon) Solar Cells: A Review
Publikacja -
Detection of high frequency current components by residual current devices
PublikacjaThe negative impact of current harmonics on the main components of residual current devices is presented. A solution for the improvement of the operation of residual current devices is proposed.
-
Case studies of resonance phenomena in high voltage overhead power lines with shunt reactors
PublikacjaMisguided design of the towers of power transmission lines can lead to serious problems such as voltage asymmetry, overvoltages, electric arc extinction difficulties or resonance – in case of double circuit line with shunt reactors. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors.