Filtry
wszystkich: 1070
-
Katalog
- Publikacje 820 wyników po odfiltrowaniu
- Osoby 20 wyników po odfiltrowaniu
- Wynalazki 8 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Aparatura Badawcza 3 wyników po odfiltrowaniu
- Kursy Online 7 wyników po odfiltrowaniu
- Dane Badawcze 209 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: ANALIZATORY IMPEDANCJI
-
Influence of sintering temperature of porous SrTi0.30Fe0.70O3-d oxygen electrode on electrochemical impedance spectroscopy spectra measured at 800 °C
Dane BadawczeThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures (800 °C; 900 °C and 1000 °C). Measure temperature was 800 °C (syntetic air, 40 ml min-1). Results converted to electrode surfaces area and dived by two electrodes.
-
Electrochemical impedance spectroscopy spectra measured at 700 °C on porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures
Dane BadawczeThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperaturs (800 °C, 900 °C and 1000 °C). EIS spectra were measured at 700 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to electrode surfaces area and dived by two...
-
Influence of sintering temperature of porous SrTi0.50Fe0.50O3-d oxygen electrode on electrochemical impedance spectroscopy spectra measured at 800 °C
Dane BadawczeThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures (800 °C; 900 °C and 1000 °C). Measure temperature was 800 °C (syntetic air, 40 ml min-1). Results converted to electrode surfaces area and dived by two electrodes.
-
Electrochemical impedance spectroscopy spectra measured at 700 °C on porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures
Dane BadawczeThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperaturs (800 °C, 900 °C and 1000 °C). EIS spectra were measured at 700 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to electrode surfaces area and dived by two...
-
Influence of sintering temperature of porous SrTi0.65Fe0.35O3-d oxygen electrode on electrochemical impedance spectroscopy spectra measured at 800 °C
Dane BadawczeThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures (800 °C; 900 °C and 1000 °C). Measure temperature was 800 °C (syntetic air, 40 ml min-1). Results converted to electrode surfaces area and dived by two electrodes.
-
Electrochemical impedance spectroscopy spectra measured at 700 °C on porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures
Dane BadawczeThis dataset contains results electrochemica impedance spectroscopy (EIS) of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperaturs (800 °C, 900 °C and 1000 °C). EIS spectra were measured at 700 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to electrode surfaces area and dived by two...
-
Analiza procedur oceny uziemień odgromowych
PublikacjaW pracy dokonano prównania różnych metod wyznaczania parametrów uziemień odgromowych na tle obowiązujących przepisów. Porównano metody wyznaczania rezystancji statycznej i udarowej oraz impedancji uziemień w szerokim zakresie częstotliwości. Sformułowano wnioski dotyczące zasadności doboru odpowiednich metod pomiarowych do kontroli uziemień o różnej konstrukcji i różnym przeznaczeniu.
-
Distribution of Relaxation Times analysis results of impedance measured in function of temperature on porous SrTi0.50Fe0.50O3-d oxygen electrode sintered at 800 °C
Dane BadawczeThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at 800 °C. Electrochemical impedance spectroscopy were measured at 800 °C; 750 °C and 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof. Ciucci’s group, was used...
-
Distribution of Relaxation Times analysis results of impedance measured in function of temperature on porous SrTi0.30Fe0.70O3-d oxygen electrode sintered at 800 °C
Dane BadawczeThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. Electrochemical impedance spectroscopy were measured at 800 °C; 750 °C and 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof. Ciucci’s group, was used...
-
Distribution of Relaxation Times analysis results of impedance measured in function of temperature on porous SrTi0.65Fe0.35O3-d oxygen electrode sintered at 800 °C
Dane BadawczeThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at 800 °C. Electrochemical impedance spectroscopy were measured at 800 °C; 750 °C and 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof. Ciucci’s group, was used...
-
Adaptive estimation of the transformer stray capacitances for DC–DC converter modelling
PublikacjaNew low cost and accurate estimation method of transformer stray capacitances for wide band DC–DC converter modelling and design is proposed. The Wiener filter (WF) method is applied to estimate the transformer impedance – referred to the selected transformer winding configurations. Laboratory tests are used to adapt the filter, that is to find optimal impedance which minimises mean square error between measured, noise perturbed...
-
Distribution of Relaxation Times analysis results of impedance measured at 700 °C on porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures
Dane BadawczeThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at different temperatures (800 °C, 900 °C and 1000 °C). Electrochemical impedance spectroscopy were measured at 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof....
-
Distribution of Relaxation Times analysis results of impedance measured at 700 °C on porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures
Dane BadawczeThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.50Fe0.50O3-d oxygen electrodes sintered at different temperatures (800 °C, 900 °C and 1000 °C). Electrochemical impedance spectroscopy were measured at 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof....
-
Distribution of Relaxation Times analysis results of impedance measured at 700 °C on porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures
Dane BadawczeThis dataset contains results of Distribution of Relaxation Times analysis (DRT) of impedance of symmetrical cells with porous SrTi0.65Fe0.35O3-d oxygen electrodes sintered at different temperatures (800 °C, 900 °C and 1000 °C). Electrochemical impedance spectroscopy were measured at 700 °C (syntetic air). The DRTTools Matlab GUI, available from prof....
-
Zaawansowane Metody Pomiarowe i Diagnostyczne 2022/2023
Kursy Online{mlang en} 1. Introduction/Guide for the use of the International System of Units2. Rules and style conventions for expressing values of quantities.3. The role of measurement uncertainty in conformity assessment. 4. Probabilistic model for measurement processes, estimation theory5. Analog-digital conversion methods6. Selected structures of classical analog-digital converters7. New techniques of analog-digital conversion: sigma-delta...
-
Zaawansowane Metody Pomiarowe i Diagnostyczne 2023/2024
Kursy Online{mlang en} 1. Introduction/Guide for the use of the International System of Units2. Rules and style conventions for expressing values of quantities.3. The role of measurement uncertainty in conformity assessment. 4. Probabilistic model for measurement processes, estimation theory5. Analog-digital conversion methods6. Selected structures of classical analog-digital converters7. New techniques of analog-digital conversion: sigma-delta...
-
Design of mm-wave MIC frequency multiplayers and mixers using simple microstrip high-pass filters
PublikacjaPrzedyskutowano podstawowe wymagania dotyczące impedancji elementów półprzewodnikowych wykorzystywanych w mieszaczach i powielaczach częstotliwości projektowanych dla zakresu fal milimetrowych. Określono typy układów filtrujących niezbędnych w różnych częściach układów, podkreślając znaczenie filtrów górnoprzepustowych. Mikropaskowy filtr ze zwartym brzegiem został wykonany i zaimplementowany w mieszaczu pracującym w zakresie 20-40GHz.
-
Compact-planar monopole loop antennas for 802.11b/g WLAN systems
PublikacjaZaproponowano planarne anteny monopolowe dla systemów komunikacji bezprzewodowej WLAN pracujących w pasmach 2.45GHz i 5.25GHz. W strukturze radiatorów zasilanych poprzez linię mikropaskową wykorzystano krzywe fraktalne: pętlę Kocha oraz pętlę Minkowskiego. W obu przypadkach uzyskano dwuzakresową pracę anten dzięki wprowadzeniu nowej konfiguracji zminiaturyzowanych transformatorów impedancji w układzie zasilania.
-
Fitted impedance spectra of a symmetrical porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode (sintered at 1000 °C, measured at 700 °C and 0.1% pO2) with an individual contributions of the respective fitting elements
Dane BadawczeThis dataset contains exemplary impedance spectra (measured at 700 °C and 0.1% pO2) for porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode sintered at 1000 °C. Results of symmetric cell impedance measurement were converted to electrode surfaces area and dived by two electrodes. Dataset conatins also fitting results and individual contributions of the respective...
-
Fitted impedance spectra of a symmetrical porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode (sintered at 1000 °C, measured at 800 °C and 0.1% pO2) with an individual contributions of the respective fitting elements
Dane BadawczeThis dataset contains exemplary impedance spectra (measured at 800 °C and 0.1% pO2) for porous Sr0.86Ti0.65Fe0.35O3 oxygen electrode sintered at 1000 °C. Results of symmetric cell impedance measurement were converted to electrode surfaces area and dived by two electrodes. Dataset conatins also fitting results and individual contributions of the respective...
-
Nowa metoda optymalizacji pracy ogniw paliwowych.
PublikacjaPrzedstawiono dynamiczną technikę impedancją jako doskonałe narzędzie służące do określenia optymalnych warunków pracy ogniw paliwowych. Możliwości tej techniki zostały przedstawione na przykładzie ustalenia optymalnej temperatury pracy. Otrzymane wyniki zostały skonfrontowane z charakterystykami prądowo napięciowymi ogniwa.
-
Optimal configuration of an electrode array for measuring ventricles' contraction
PublikacjaAn influence of an electrode-array configuration on an impedance signal composition for a fixed spatial distribution of its sources is examined in the paper. The Finite Element Method and Geselowitz relationship were used for examining three different electrode-arrays. A sensitivity approach was used to evaluate each configuration assuming that localization of the signal source is known. A conductivity change, thus the source of...
-
Katedra Metrologii i Systemów Informacyjnych
Zespoły Badawcze* Diagnostyka silników elektrycznych i magnesów nadprzewodzących * Metody pomiaru impedancji zwarciowej * Zastosowania modulowanych częstotliwościowo sygnałów impulsowych * Pomiary dla diagnostyki medycznej * Ocena niepewności pomiaru * Zastosowanie grafenu do wykrywania elektronicznego
-
Glucose/O2 biofuel cell to generate electricity
PublikacjaOgniwa paliwowe mogą stanowić jedną z głównych technologii do produkowania energii w przyszłości. Pozwalają na uzyskanie energii elektrycznej i ciepła bezpośrednio z zachodzącej w nich reakcji chemicznej. Glukoza utleniana jest do glukonolaktonu przez enzym Glucose Oxidase, który jest immobilizowany ze specyficznym mediatorem na anodzie, podczas gdy tlen jest redukowany do wody za pomocą enzymu Laccase zimmobilizowanego ze specyficznym...
-
A comprehensive evaluation of mimosa extract as a corrosion inhibitor on AA6060 alloy in acid rain solution: part I. Electrochemical AC methods
PublikacjaThe inhibition effect of mimosa extract on the corrosion of AA6060 aluminum alloy in acid rain solution was investigated by electrochemical impedance spectroscopy and dynamic electrochemical impedance spectroscopy (DEIS). All the studied electrochemical parameters showed good corrosion inhibitive characteristics with respect to the aluminum alloy in the tested solution. Inhibitor efficiency increased with the concentration and...
-
A concept of measurement system based on the Z-Wave standard
PublikacjaIn the paper a new concept of measurement system based on the Z-Wave standard is presented. This standard is dedicated to use mainly in home automation systems, but its properties enable to use it in dispersed measurement systems and support wireless communication between measurement nodes in a mesh-type network. In the paper basic metrological aspects of the Z-Wave standard and an example of impedance measurement system are discussed.
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of nano-nickel based coating sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of nano-nickel based coating sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
System pomiarowy spektroskopii impedancyjnej do diagnostyki obiektów technicznych
PublikacjaW artykule przedstawiono system pomiarowy ukierunkowany na testowanie i diagnostykę obiektów elektronicznych i nieelektrycznych. Charakterystyczną cechą systemu jest wyposażenie w bibliotekę metod spektroskopii impedancyjnej umożliwiających identyfikację elementów niedostępnych zaciskowo. Omówiono architekturę systemu, podstawy teoretyczne metod wyznaczania widma impedancji oraz przedstawiono wyniki weryfikacji praktycznej metod...
-
Wyłącznik ograniczający z możliwością szybkiego i wielokrotnego samoczynnego ponownego załączania.
PublikacjaWyłącznik, obok zdolności szybkiego i wielokrotnego działania w cyklu SPZ umożliwia samoczynne włączenie do obwoduw początkowej chwili zwarcia dużej impedancji dławików ograniczających wartość prądu zwarciowego. Przepięcia łaczeniowe generowane przez ten wyłącznik są ograniczone do bardzo niskiego poziomu. Ograniczony jest również poziom zapadu napięcia w czasie zwarcia w obwodzie chronionym tym wyłącznikiem.
-
Hybrid inductance-thyristor short-circuit current limiting devices
PublikacjaDla wartości prądu w gałęzi w której zainstalowane jest urządzenie jest mniejsza od prądu w dławiku urządzenia, dławik jest zwarty gałęzią z tyrystorem. Impedancja bieguna urządzenia hybrydowego jest praktycznie równa zero. W chwili wzrostu prądu w gałęzi z urządzeniem ograniczającym ponad tę wartość, do obwodu głównego wtrącona zostaje impedancja kolejno dwóch dławików, ograniczając bezzwłocznie dynamikę i amplitudę prądu zwarciowego....
-
Impulse and high frequency methods of lighting earthing testes.
PublikacjaUziemienia projektowane dla prądów zwarciowych nie zawsze są właściwe do odprowadzania prądów piorunowych, gdzie należy brać pod uwagę impedancję uziemień. W pracy porównano metody: udarową oraz wysokiej częstotliwości zastosowane do oceny przydatności uziemień odgromowych.
-
Barbara Becker prof. dr hab. inż.
Osoby -
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 3
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name EPCS1) sample 3. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
AOR Nowe katalizatory oparte na metalach nieszlachetnych do elektroutleniania amoniaku
ProjektyProjekt realizowany w Katedra Inżynierii Procesowej i Technologii Chemicznej zgodnie z porozumieniem UMO-2021/41/B/ST4/03255 z dnia 2021-11-26
-
Resonant Conditions in a Node with an SVC Compensator
PublikacjaThe primary purpose of installing static shunt compensators in power grids is to improve the voltage conditions. Additional reactive power sources increase the system’s voltage stability and enable faster system recovery after a voltage failure. This paper presents the impact of an SVC device’s structure and settings on impedance change in the supply system, and hence on the frequencies at which resonance phenomena can develop.
-
Double-ridged horn antenna with sinusoidal ridge profile
PublikacjaPrzedstawiono wyniki symulacji numerycznej oraz pomiarów parametrów anteny tubowej z podwójnym grzbietem. Badania numeryczne dotyczyły zarówno samego układu zasilania falowodu grzbietowego jak i całej anteny z uwzględnieniem sinusoidalnego profilu impedancji grzbietu. Wyniki obliczeń dopasowania oraz charakterystyk promieniowania, wykonanych przy użyciu symulatora QW-3D, porównano z wynikami pomiarów, stwierdzając dobrą zgodność...
-
Wpływ uwarunkowań rzeczywistych na pracę równoległego filtru aktywnego sterowanego ze sprzężeniem od prądu zasilającego
PublikacjaW artykule przedstawiono wpływ uwarunkowań rzeczywistych na pracę równoległego filtru aktywnego i zdolność kompensacji prądów harmonicznych. Zbadano wpływ opóźnień czasowych wynikających z implementacji cyfrowej sterowania, wpływ impedancji zwarciowej sieci zasilającej oraz błędów generowania napięcia przekształtnika na jakość kompensacji filtru. Badania symulacyjne przeprowadzono dla trzech układów sterowania: otwartego, zamkniętego...
-
Wpływ uwarunkowań rzeczywistych na pracę równoległego filtru aktywnego sterowanego ze sprzężeniem od prądu zasilającego
PublikacjaW artykule przedstawiono wpływ uwarunkowań rzeczywistych na pracę równoległego filtru aktywnego i zdolność kompensacji prądów harmonicznych. Zbadano wpływ opóźnień czasowych wynikających z implementacji cyfrowej sterowania, wpływ impedancji zwarciowej sieci zasilającej oraz błędów generowania napięcia przekształtnika na jakość kompensacji filtru. Badania symulacyjne przeprowadzono dla trzech układów sterowania: zamkniętego, otwartego...
-
Low temperature broad band dielectric spectroscopy of multiferroic Bi6Fe2Ti3O18 ceramics
PublikacjaIn the present research the tool of broadband dielectric spectroscopy was utilized to characterize dielectric behavior of Bi6Fe2Ti3O18 (BFTO) Aurivillius-type multiferroic ceramics. Dielectric response of BFTO ceramics was studied in the frequency domain (Δν=0.1Hz – 10MHz) within the temperature range ΔT=-100°C – 200°C. The Kramers-Kronig data validation test was employed to validate the impedance data measurements and it was found...
-
The effect of cobalt addition on the corrosion behavior of near equiatomic NiTi shape memory alloy in normal saline solution, impedance and microscopic studies
Dane BadawczeThe electrochemical and corrosion (uniform and localized) behavior of a binary Ni52Ti48 shape memory alloy (SMA) and two ternary Ni52Ti48-xCox (x = 1.5 and 4.0 wt.%) SMAs were studied. Measurements were conducted in 0.9% NaCl solution at 37 oC. This dataset contains the results of electrochemical impedance spectroscopy (EIS) studies done on daily basis...
-
INFLUENCE OF BISMUTH CONTENT ON COMPLEX IMMITTANCE CHARACTERISTICS OF PRESSURELESS SINTERED BiNbO4 CERAMICS
PublikacjaGoal of the present research was to study immittance properties of BiNbO4 ceramics fabricated by the solid state reaction route followed by pressureless sintering. Four sets of samples were examined, namely the one fabricated from the stoichiometric mixture of oxides, viz. Bi2O3 and Nb2O5 as well as the ones with an excess of 3%, 5% and 10% by mole of Bi2O3. The immittance properties were studied by impedance spectroscopy. Measurements...
-
Synteza, właściwości i zastosowanie cieczy jonowych, pochodnych naturalnych związków organicznych
PublikacjaW ramach pracy doktorskiej zaprojektowano, zsyntezowano oraz określono właściwości cieczy jonowych zawierających w swojej strukturze cząsteczki pochodzenia naturalnego – głównie aminokwasów w postaci N-acetylowanej. Wybrane ciecze jonowe zostały wykorzystane jako katalizatory przeniesienia fazowego w reakcjach N- oraz C¬-substytucji. Wydajności reakcji zostały porównane ze standardowymi katalizatorami. Innym rodzajem otrzymanych...
-
Investigation of corrosion behavior of 6060 and 6082 aluminum alloys under simulated acid rain conditions
PublikacjaInstantaneous impedance changes of 6060 and 6082 type aluminum alloys in pure water, and simulated acid rain poured into the pure water was investigated by dynamic electrochemical impedance spectroscopy (DEIS). In this way, the influence of aluminum content on the corrosion behavior of 6060 and 6082 type aluminum alloys immersed in simulated acid rain was determined. The corrosion rate of the alloy decreased with increasing Al...
-
Dynamic Nanoimpedance Characterization of the Atomic Force Microscope Tip-Surface Contact
PublikacjaNanoimpedance measurements, using the dynamic impedance spectroscopy technique, were carried out during loading and unloading force of a probe on three kinds of materials of different resistivity. These materials were: gold, boron-doped diamond, and AISI 304 stainless steel. Changes of impedance spectra versus applied force were registered and differences in the tip-to-sample contact character on each material were revealed. To...
-
PROBLEMS WITH CORROSION PROTECTION STEEL STACKS IN FGD SYSTEMS
PublikacjaThis paper presents problems associated with corrosion of steel stacks and changes in philosophy of corrosion protection when implemented into flue gas desulphurization systems. In-situ tests were taken by means of electrochemical impedance spectroscopy at a stack which discharges flue gas before wet lime/limestone desulphurization. A very rapid soaking of spherical infill vinylester coating with electrolyte has been observed....