Wyniki wyszukiwania dla: dosimetry
-
Visualizing the Dose Distribution and Linear Energy Transfer by 1D and 2D ESR Imaging: A Potassium Dithionate Dosimeter Irradiated with C6+ and N7+ Ions
Publikacja -
SU‐GG‐T‐286: Performance of An Improved Optical Computed Tomography Polymer Gel Dosimeter System for 3‐D Dose Verification of Static and Dynamic Phantom Deliveries
Publikacja -
Application of Passive Samplers in Monitoring of Organic Constituents of Air
PublikacjaThe principles of passive dosimetry, which has been known for over 100 years, are finding an ever increasing use in analytical practice and are being used as a convenient technique for isolation and enrichment of analytes from various environmental media. Due to its simplicity, a variety of designs, as well as the possibility of using a number of different final determination techniques, passive dosimetry has been applied in...
-
Determination of Volatile Organic Compounds in Indoor Air in the Gdansk Area Using Permeation Passive Samplers
PublikacjaPassive dosimetry — known for over a hundred years — is still a useful tool in monitoring air pollutants. In this work, permeation passive samplers were used to determine indoor air quality in 22 apartments located in the Gdansk area in the northern part of Poland. The results obtained by the passive sampling technique were compared to those obtained by dynamic sampling. Attempts were also made to identify indoor sources of...
-
Employment of passive sampling in monitoring indoor air quality in selected residences in a Tri-city area in Poland
PublikacjaNa etapie pobierania próbek analitów zastosowano dwie techniki: pasywną - wykorzystującą permeacyjne dozymetry pasywne oraz technikę klasyczną - wykorzystującą rurki sorpcyjne. Wyznaczono sumaryczną zawartość TVOC lotnych związków organicznych.
-
A comparative study of the performance of passive samplers
PublikacjaPodstawowym celem podjętych badań było porównanie pracy dozymetrów pasywnych wykorzystywanych na etapie izolacji i wzbogacania lotnych związków organicznych z powietrza atmosferycznego na terenie aglomeracji Trójmiejskiej. Jako próbniki do pobierania próbek analitów zastosowano komercyjne dozymetry pasywne typu dyfuzyjnego (Radiello i Orsa 5) oraz dozymetry typu permeacyjnego własnej konstrukcji wyposażone w półprzepuszczalną membranę...
-
Application of low-cost Gallium Arsenide light-emitting-diodes as kerma dosemeter and fluence monitor for high-energy neutrons
Publikacja -
Characterisation of PRESAGE™: A new 3-D radiochromic solid polymer dosemeter for ionising radiation
Publikacja -
CALIBRATION OF LOW ENERGY X-RAY EXPERIMENTAL SETUP WITH STRONGLY FILTERED BEAM USING DATA FROM A SEMICONDUCTOR AND A THERMOLUMINESCENT DETECTORS
Publikacja -
IMAGING OF PROTON BRAGG PEAKS IN LiF
Publikacja -
LITHIUM FLUORIDE CRYSTALS AS FLUORESCENT NUCLEAR TRACK DETECTORS
Publikacja -
Application of PL-Grid Platform for Modeling of the Selected Acoustic Phenomena
PublikacjaDomain grids are specific computational environments, developed within the PLGrid Plus project. For the Acoustic domain grid two supercomputer grid based services were prepared. Dedicated software consists of the outdoor sound propagation module and psychoacoustical noise dosimeter. The results are presented in a form of maps of sound level and Temporary Threshold Shift (TTS) values, therefore the services may play an informative...
-
Passive sampling and/or extraction techniques in environmental analysis: a review
PublikacjaThe current state-of-the-art of passive sampling and/or extraction methods for long-term monitoring of pollutants in different environmental compartments is discussed in this review. Passive dosimeters that have been successfully used to monitor organic and inorganic contaminants in air, water, sediments, and soil are presented. The application of new approaches to the determination of pollutants at the sampling stage is discussed....
-
Determination of Volatile Organic Compounds in indoor air in the Gdansk area using permeation passive samplers.
PublikacjaDozymetria pasywna, znana od wielu lat, jest użytecznym narzędziem w monitoringu poziomu zanieczyszczeń. Do określenia jakości powietrza wewnętrznego w 22 pomieszczeniach mieszkalnych, zlakoalizowanych na terenie Gdańska, wykorzystano dozymetry pasywne typu permeacyjnego na etapie pobierania próbek analitów. Uzyskane wyniki porównano z wynikami uzyskanymi przy wykorzystaniu matedy dynamicznej. Podjęto również próbę identyfikacji...
-
Radionuclides activity and effective doses referred to geological formations
PublikacjaNaturally occurring radioactive materials (NORM) are present in Earth’s crust and they caused natural background radiation, variable in different regions. Liquid, gas and solid radionuclides emit three types of radiation – alpha, beta and gamma. Fluctuations of natural radioactivity in different geological formations in the world and in Poland were compared in relation to radiological hazard. Also drilling cuttings from boreholes...
-
A new methodological approach to the noise threat evaluation based on the selected physiological properties of the human hearing system
PublikacjaA new way of assessment of noise-induced harmful effects on human hearing system is presented in the paper. The method takes into consideration properties of the selected physiological human hearing system. On the basis of the hearing examinations and noise measurements results and psychoacoustical noise dosimeter performance the new indicators of the noise harmfulness were proposed. The evaluation of the proposed indicators were...
-
Towards Understanding the Health Aspects of the Processing of Lignocellulosic Fillers
PublikacjaHealth and safety issues should be addressed during the development and investigation of the industrial processes. In order to develop a sustainable process and fully evaluate its benefits and drawbacks for its optimization, it is crucial to determine its impact on the surrounding environment. This study aimed to assess the emission of volatile organic compounds during the modification of lignocellulosic fillers with passive dosimetry....
-
Multimedia System for Environmental Noise Monitoring. [Multimedialny System Monitorowania Hałasu Środowiskowego]
PublikacjaIntroductionNumerous reports relating to noise threats in Poland indicate that they occur commonly. The noise has an enormous impact on the health and life quality of the human beings. Noise pollution in Poland is greater than in others UE countries, moreover it has been increased recently. Taking into account 2002/49/WE directive related to the control and assessment of environmental noise a necessity of monitoring these threats...
-
Brygida Mielewska dr
OsobyBrygida Mielewska urodziła się 1 grudnia 1972 r. w Gdyni. Studia wyższe ukończyła w 1997 r. na Wydziale Matematyki, Fizyki i Informatyki Uniwersytetu Gdańskiego, uzyskując tytuł magistra fizyki. W latach 1997–2003 pracowała na stanowisku asystenta w Katedrze Fizyki Zjawisk Elektronowych na Wydziale Fizyki Technicznej i Matematyki Stosowanej Politechniki Gdańskiej. Pracę doktorską pisała pod kierunkiem prof. dr. hab. Mariusza Zubka,...
-
Influence of sensor design and optical properties of tissue on the photoplethysmographic signal
PublikacjaPhotopletysmography and an associated technique called pulse oximetry are still explored due to the expectations that they give a lot of information about the state of the patient and, also, due to the fact that they are non invasive. Knowledge about the impact of various parameters on the measured signal leads to a faster and a more reliable way of analyzing measurement results and finding the dependencies between the involved...
-
Multimedia services applied to noise and hearing monitoring and measuring
PublikacjaThe goal of this chapter is to show a research study related to processing of data acquired by the multimedia services engineered at the multimedia systems department (MSD) of the Gdansk University of Technology. This concerns a survey on noise threat employing the multimedia noise monitoring system (MNMS) and hearing tests performed by the "I can hear. . . " system. The obtained results of the noise measurements revealed that...
-
Inhibition of amyloid fibril formation of hen egg white lysozyme by trimethylamine N-oxide at low pH
PublikacjaIn vitro inhibition of the formation of fibrous aggregates of proteins (amyloids) has gained increasing attention due to the number of diseases associated with protein misfolding and fibrillation. An interesting group of compounds for which pronounced activity against this phenomenon can be expected consists of low molecular weight substances (osmolytes) which have the ability to change protein stability. Here we investigate the...
-
Dozymetria pasywna - dogodne narzędzie do badania zanieczyszczeń środowiska wodnego
PublikacjaDozymetry pasywne stanowią coraz powszechniej wykorzystywane narzędzie do pobierania próbek analitów ze środowiska wodnego. Pobieranie analitów przy użyciu próbników pasywnych następuje na drodze swobodnego transportu masy przez membranę do medium zatrzymującego na skutek różnicy potencjałów chemicznych związków w medium zatrzymującym i środowiskiem wodnym, w którym umieszczany jest próbnik. Próbniki umieszczane są w wodzie na...
-
Selected concentration techniques for gas chromatographic analysis of environmental samples
PublikacjaThe paper describes the role and tasks of environmental analysis and monitoring. It emphasises the leading role played by gas chromatography, especially when coupled with suitable sample preparation. This is demonstrated by some literature evidence and mainly by the author's original work on the design of sample preparation apparatus and development of GC-based methods of determination of a wide variety of organic pollutants in...
-
Application of passive sampling techniques for monitoring the aquatic environment
PublikacjaDozymetry pasywne są coraz powszechniej stosowanym narzędziem do pobierania próbek analitów ze środowiska wodnego. W przypadku próbników pasywnych pobieranie analitów następuje na drodze swobodnego transportu masy przez membranę do medium zatrzymującego, na skutek różnicy potencjałów chemicznych analitów w medium zatrzymującym w próbniku i środowiskiem wodnym, w którym umieszczany jest próbnik. Największą zaletą stosowania próbników...
-
Distributed System For Noise Threat Evaluation Based On Psychoacoustic Measurements
PublikacjaAn innovative system designed for the continuous monitoring of acoustic climate of urban areas was presentedin the paper. The assessment of environmental threats is performed using online data, acquired through a grid ofengineered monitoring stations collecting comprehensive information about the acoustic climate of urban areas.The grid of proposed devices provides valuable data for the purpose of long and short time acoustic climateanalysis....
-
Effect of Maximal Apnoea Easy-Going and Struggle Phases on Subarachnoid Width and Pial Artery Pulsation in Elite Breath-Hold Divers
PublikacjaPurpose: The aim of the study was to assess changes in subarachnoid space width (sas-TQ), the marker of intracranial pressure (ICP), pial artery pulsation (cc-TQ) and cardiac contribution to blood pressure (BP), cerebral blood flow velocity (CBFV) and cc-TQ oscillations throughout the maximal breath hold in elite apnoea divers. Non-invasive assessment of sas-TQ and cc-TQ became possible due to recently developed method based on...
-
Wykorzystanie próbników pasywnych w analityce zanieczyszczeń wody (badania modelowe)
PublikacjaDozymetry pasywne stanowią coraz powszechniej wykorzystywane narzędzie do pobierania próbek analitów ze środowiska wodnego. W pracy opisano podstawy teoretyczne działania dozymetrów pasywnych oraz czynniki wpływające na szybkość pobierania próbek analitów zwody. Przedstawiono również charakterystykę oraz omówiono obszar praktycznego zastosowania wybranych typów próbników pasywnych.Przedmiotem moich badań było zastosowanie próbnika...