Filtry
wszystkich: 3368
-
Katalog
- Publikacje 1275 wyników po odfiltrowaniu
- Czasopisma 7 wyników po odfiltrowaniu
- Osoby 9 wyników po odfiltrowaniu
- Wynalazki 2 wyników po odfiltrowaniu
- Projekty 1 wyników po odfiltrowaniu
- Laboratoria 3 wyników po odfiltrowaniu
- Aparatura Badawcza 4 wyników po odfiltrowaniu
- Kursy Online 40 wyników po odfiltrowaniu
- Wydarzenia 2 wyników po odfiltrowaniu
- Dane Badawcze 2025 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: MMG
-
LanroNET, a non-interventional, prospective study to assess the resource utilization and cost of lanreotide autogel 120 mg in Polish patients with neuroendocrine tumors – results of interim analysis
Publikacja -
Expanded graphite assistant construction of gradient-structured char layer in PBS/Mg(OH)2 composites for improving flame retardancy, thermal stability and mechanical properties
Publikacja -
MMM-2024
Kursy OnlineI st, 3 sem. Automatyka, Cybernetyka i Robotyka
-
MMM-2022
Kursy OnlineI st, 3 sem. Automatyka, Cybernetyka i Robotyka
-
MMM-2023
Kursy OnlineI st, 3 sem. Automatyka, Cybernetyka i Robotyka
-
Experimental economics in business education: Using simple games to achieve multifaceted effects
PublikacjaEconomics differs from other sciences not only because of its normative part, but also because of very limited use of experiments. In this way, economics is often perceived as being methodologically more similar to astronomy or meteorology rather than physics or chemistry. Over last decades, however, experimental economics has been significantly developed. This chapter presents some of the possibilities for academic teachers to...
-
SU‐GG‐T‐208: 3‐D Dosimetric Comparison of IMRT with 2.5 Mm HD120 MLC Using Optical CT Based Polymer Gel and PRESAGE Dosimeters
Publikacja -
Intensity Ratio of Kβ/Kα in Selected Elements from Mg to Cu, and the Chemical Effects of Cr Kα1,2 Diagram Lines and Cr Kβ/Kα Intensity Ratio in Cr Compounds
Publikacja -
Fourier transform infrared spectroscopic and theoretical study of water interactions with glycine and its N-methylated derivatives
PublikacjaZbadano hydratację glicyny i jej metylowych pochodnych: N-metyloglicyny (NMG), N,N-dimetyloglicyny (DMG) i N,N,N-trimetyloglicyny (TMG) przy wykorzystaniu spektroskopii FTIR, z zastosowaniem cząsteczki HDO jako sondy molekularnej. Ilościowa wersja metody widm różnicowych pozwoliła na wyizolowanie widma wody zaburzonej przez substancję rozpuszczoną. Wyniki widmowe zostały skonfrontowane z obliczeniami teoretycznymi w ramach teorii...
-
Metamaterial-Based Series-Fed Antenna with High Gain and Wideband Performance for Millimeter Wave Spectrum Applications
PublikacjaThis paper presents a high-gain, wideband series-fed antenna designed for 5G millimeter-wave (MMW) applications. The structure employs a substrate-integrated waveguide (SIW)-based power splitter and metamaterials (MMs). The power divider functions effectively at 27.5 GHz, exhibiting an impedance bandwidth from 26.9–28.6 GHz. The series-fed dipole is assembled on the SIW-based power splitter, incorporating four dipoles with varying...
-
Development and optimization of simplified method of fast sequential HR-CS-FAAS analysis of apple juices on the content of Ca, Fe, K, Mg, Mn and Na with the aid of response surface methodology
Publikacja -
Influence of synthesis conditions on glass formation, structure and thermal properties in the Na 2 O-CaO-P 2 O 5 system doped with Si 3 N 4 and Mg
PublikacjaOxynitride phosphate glasses and glass-ceramics were prepared using new synthesis routes for phosphate glasses. Materials were melted from pre-prepared glass samples in the system Na-Ca-P-O with addition of Mg and/or Si3N4 powders under different preparation conditions. The melting process was conducted at 1000–1500 °C either under air or nitrogen atmosphere to obtain materials with different nitrogen content. Their topography...
-
Frequency bands selection of the Portevin-LeChatelier
PublikacjaEfekt Portevina-LeChateliera ujawnia się w postaci skokowych zmian naprężenia w trakcie procesu odkształcenia próbek pewnych stopów. Zjawisko PLC występuje w kilku odmianach charakteryzujących się istotnymi różnicami zarówno w przestrzennym rozkładzie pasm odkształcenia jak też przebiegu krzywej naprężeniowej. Przebiegi odpowiadające różnym odmianom serration charakteryzują się odmiennymi właściwościami rozkładu energetycznego...
-
Detailed experimental investigations on frictional pressure drop of R134a during flow boiling in 5 mm diameter channel: The influence of acceleration pressure drop component =Études expérimentales détaillées sur la chute de pression frictionnelle du R134a lors de l'ébullition en écoulement dans un canal de 5 mm de diamètre : influence de la composante d'accélération de la chute de pression
PublikacjaThis article presents detailed two-phase diabatic pressure drop data for refrigerant R134a at a saturation pressure of 5.5 bar corresponding to the saturation temperature of 19.4 °C. Study cases have been set for a mass flux varying from 100 to 500 kg m−2 s−1. The obtained data are used as a validation of the void fraction literature models, a set of graphs shows comparisons, for a representative set of experimental conditions,...
-
Overview of Metamaterials-Integrated Antennas for Beam Manipulation Applications: The Two Decades of Progress
PublikacjaMetamaterials (MMs) are synthetic composite structures with superior properties not found in naturally occurring materials. MMs have gained massive attention over the last two decades because of their extraordinary properties, such as negative permittivity and permeability. These materials enable many applications in communication subsystems, especially in the field of antenna design, to enhance gain, bandwidth, and efficiency,...
-
Optimization of capillary isotachophoretic method for determination of major macroelements in blue honeysuckle berries (Lonicera caerulea L.) and related products
PublikacjaA reliable and repeatable isotachophoretic method for the simultaneous determination of K+, Na+, Ca2+, Mg2+ and ammonium in berries of different blue honeysuckle cultivars was developed. The usefulness of the complex-forming equilibria in determining the cations mentioned above was studied. The addition of 7.5 mM 18-crown-6 and 2 mM α-hydroxyisobutyric acid to sulfuric acid enhanced the separation capacity of the leading electrolyte....
-
N-phosphonomethylglycine utilization by the psychrotolerant yeast Solicoccozyma terricola M 3.1.4.
PublikacjaSolicoccozymaterricolaM 3.1.4., the yeast strain isolated from soil sample from blueberry cultivation in MiedzyrzecPodlaski in Poland, is capable to split of phosphorus to nitrogen and nitrogen to carbon bonds inN-phosphono-methylglycine (PMG, glyphosate). The biodegradation process proceeds in the phosphate-independent manner. Itis the first example of a psychrotolerant yeast strain able to degrade PMGviaCeN bond cleavage accompanied...
-
AFM visualization of Mg alloy surface modification
Dane BadawczeMagnesium alloys with additives improving their mechanical properties are valued as materials with low density and elasticity coefficient. Additionally, their biocompatibility and biodegradability make them interesting in prosthetic applications. However, the last of these features, valuable in medicine, contradicts the industrial needs for the described...
-
Izolacja drożdży psychrotolerancyjnych oraz ocena ich zdolności do wykorzystania N-fosfonometyloglicyny jako źródła pierwiastków biogennych
PublikacjaN-fosfonometyloglicyna (PMG, glifosat) jest substancją aktywną herbicydu Roundup o szerokim spektrum aktywności biologicznej. Mechanizm jego działania opiera się na inhibicji aktywności syntazy 5-enolopirogroniano-szikimowo-3-fosforanowej (EPSP), przez co hamowana jest biosynteza aminokwasów aromatycznych u roślin. Glifosat jest związkiem fosforoorganicznym, w którego budowie wyróżnia się trwałe wiązanie C-P. Szybkość rozkładu...
-
HR-CS FAAS based method for direct determination of total concentrations of Ca, Fe, Mg and Mn in functional apple beverages and evaluation of contributions of the bioaccessible fraction of these elements by in vitro gastrointestinal digestion and chemical fractionation
Publikacja -
OPINIA TECHNICZNA O BUDOWLI PRZEZNACZONEJ DO PROWADZENIA RUCHU KOLEJOWEGO – PODKŁAD DREWNIANY NOWY TYPU IIIB DLA TORÓW O SZEROKOŚCI 750 MM ZASTOSOWANY W TORACH KROŚNICKIEJ KOLEI WĄSKOTOROWEJ
PublikacjaZlecenie obejmuje wykonanie badań koniecznych przez jednostkę upoważnioną i przedstawienie opinii jednostki upoważnionej celem uzyskania świadectwa dopuszczenia do eksploatacji typów budowli przeznaczonych do prowadzenia ruchu kolejowego: szyny kolejowej, systemu przytwierdzeń, podkładu kolejowego, rozjazdu kolejowego (Rozporządzenie Ministra Transportu, Budownictwa i Gospodarki Morskiej z dnia 7 sierpnia 2012 r. w sprawie wykazu...
-
Solid-contact lead(II) ion-selective electrodes for potentiometric determination of lead(II) in presence of high concentrations of Na(I), Cu(II), Cd(II), Zn(II), Ca(II) and Mg(II)
PublikacjaLead and its compounds are a serious threat to the environment. Monitoring of this toxic heavy metal is a driving force for the continuous development of novel lead(II) ionophores to be applied in ion-selective electrodes. In this work a highly selective lead(II) ionophore, namely 25,26,27,28-tetrakis(piperidinylthiocarbonylmethylene)-p-tert-butylcalix[4]arene, was used in solid-contact ion-selective electrodes for determination...
-
Design optimization of novel compact circular polarization antenna
PublikacjaThe paper describes a structure and a design optimization procedure of a miniaturized circular polarization antenna with elliptical ground plane slots and feed line with stepped-impedance stubs. Constrained optimization of all antenna parameters is executed in order to explicitly reduce the antenna size while maintaining required impedance axial ratio bandwidth of 5 GHz to 7 GHz at the same time. The size of the optimized antenna...
-
XXX Wieczór z Ekonomią
WydarzeniaJubileuszowe spotkanie Wieczoru z Ekonomią odbędzie się we wtorek 3.03.20 r. o godz. 18:00 w sali 318/319 na WZiE. Gościem będzie dr Paweł Umiński. Temat spotkania: „Nowoczesna Teoria Monetarna MMT".
-
Analysis of efficiency of phosphates sorption by different granulation of selected reactive material
PublikacjaIn the light of the need to find an effective way to remove phosphorus from wastewater, studies on the suitability of sorption materials in this process should be conducted. The aim of the study was to examine the potential benefits of using selected adsorbents to reduce orthophosphates from the model solution under steady conditions. The study was conducted on a laboratory scale using synthetic wastewater with concentration of...
-
Room temperature solvent extraction for simple and fast determination of total concentration of Ca, Cu, Fe, Mg, Mn, and Zn in bee pollen by FAAS along with assessment of the bioaccessible fraction of these elements using in vitro gastrointestinal digestion
Publikacja -
Cyclic polarization studies of Mg corrosion in alkaline environment
Dane BadawczeThe dataset contains the cyclic polarization studies of Mg (99.99%) in NaOH electrolyte at different pH values: 10, 11 and 12 aiming at understanding of Mg(OH)2 passive layer formation mechanism and conditions. The electrochemical studies were carried out in a three electrode setup, with Pt mesh as the counter electrode and Ag|AgCl as the reference...
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 500 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 500 mm stroke subjected only to a mass load of 1640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 750 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 1100 g
Dane Badawcze -
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 150 mm stroke subjected only to a mass load of 1650 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 450 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 500 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 300 mm stroke subjected only to a mass load of 1680 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 930 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 560 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 100 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 100 mm stroke subjected only to a mass load of 640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 300 mm stroke subjected only to a mass load of 1530 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 63 mm piston diameter and 150 mm stroke subjected only to a mass load of 1040 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 50 mm piston diameter and 150 mm stroke subjected only to a mass load of 640 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 100 mm stroke subjected only to a mass load of 900 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....
-
Dynamics of a linear pneumatic actuator with 80 mm piston diameter and 300 mm stroke subjected only to a mass load of 2570 g
Dane BadawczeThe aim of the study was to determine the dynamics of a linear pneumatic cylinder subjected only to mass load. An actuator of one of the well known European manufacturers was tested.The experiment were to measure pressure changes in both chambers of the actuator and the position of the piston during stroke and retracting. The test was repeated 11 times....