Filtry
wszystkich: 215
-
Katalog
Wyniki wyszukiwania dla: KNEE BIOMECHANICS
-
Biomechanics of the medial meniscus in the osteoarthritic knee joint
PublikacjaBackground. Increased mechanical loading and pathological response of joint tissue to the abnormal mechanical stress can cause degradation of cartilage characteristic of knee osteoarthritis (OA). Despite osteoarthritis is risk factor for the development of meniscal lesions the mechanism of degenerative meniscal lesions is still unclear. Therefore, the aim of the study is to investigate the influence of medial compartment knee OA...
-
Możliwości modelowania w biomechanice = Modelling capabilities in biomechanics
PublikacjaOmówiono mozliwości modelowania w biomechanice. Zaprezentowano główne kierunki badań biomechanicznych oraz metody modelowania, w tym najbardziej popularne oprogramowania do symulacji komputerowej modeli biomechanicznych ciała człowieka. Przedstawiono metody wykorzystania programów komputerowych CHARM, SIMM oraz AnyBody System do utworzenia biomechanicznych modeli ramienia człowieka.
-
Friction and flow around growing tissue in bioreactor. Proceedings of the Biomechanics 2003. Engineering Biomechanics - Biomechanics of Sport - Medical Biomechanics.
PublikacjaPrzedstawione zostały problemy teoretyczne związane z wyznaczaniem sił tarcia, współczynników tarcia, rozkładów wartości ciśnienia w warstwie przyściennej wytworzonej wokół hodowanej tkanki w bioreaktorze w trakcie opływu tej tkanki cieczami biologicznymi o właściwościach lepkosprężystych. Model Rivlina Ericksena lepkosprężystej cieczy biologicznej jest tu brany pod uwagę.
-
Acta of Bioengineering and Biomechanics
Czasopisma -
KNEE
Czasopisma -
JOURNAL OF BIOMECHANICS
Czasopisma -
Wiktoria Wojnicz dr hab. inż.
OsobyDSc in Mechanics (in the field of Biomechanics) - Lodz Univeristy of Technology, 2019 PhD in Mechanics (in the field of Biomechanics) - Lodz Univeristy of Technology, 2009 (with distinction) Publikacje z listy MNiSW (2009 - ) Wojnicz W., Wittbrodt E., Analysis of muscles' behaviour. Part I. The computational model of muscle. Acta of Bioengineering and Biomechanics, Vol. 11, No.4, 2009, p. 15-21 Wojnicz W., Wittbrodt E.,...
-
Chosen aspects of muscle biomechanics
PublikacjaConsidering a striated skeletal muscle as a different properties mechanical system, one can understand series of important phenomena happening in a real muscle phenomenon of muscle: 1) force delivery to skeletal apparatus through tendons; 2) changing of exerted muscle belly mass distribution with regards to skeletal apparatus; 3) beginning drop of muscle force. A disregard of first phenomenon causes an impossibility to explain...
-
3D intact knee model used in analysis of the medial meniscus biomechanics in the osteoarthritic knee joint - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model with original geometry and material parametetrs was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. The file was created in Abaqus 6.14-2, but can be read in a text editor.
-
Modeling knee joint endoprosthesis mode of deformation
Publikacja -
CLINICAL BIOMECHANICS
Czasopisma -
The Influence of Articular Cartilage Thickness Reduction on Meniscus Biomechanics
PublikacjaObjective Evaluation of the biomechanical interaction between meniscus and cartilage in medial compartment knee osteoarthritis. Methods The finite element method was used to simulate knee joint contact mechanics. Three knee models were created on the basis of knee geometry from the Open Knee project. We reduced the thickness of medial cartilages in the intact knee model by approximately 50% to obtain a medial knee osteoarthritis...
-
Journal of Knee Surgery
Czasopisma -
3D model of osteoarthritic (OA) knee joint for analysis of the medial meniscus biomechanics - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. In the OA model thickness of articular cartilage and material parameters of the cartilage and menisci were reduced to simulate degenerative changes in the...
-
Osteotomies and Total Knee Arthroplasty: Systematic Review and Meta-Analysis
Publikacja -
Jaw biomechanics: Estimation of activity of muscles acting at the temporomandibular joint
PublikacjaThe aim of this study was to elaborate a method of estimation of activity of surface muscles acting at the temporomandibular joint of the healthy subjects by using a surface electromyography (EMG). The scope of this study involved testing chosen jaw motions (open, close, lateral deviation) and process of mastication occurring during eating food with different toughness (chewing gum, cereal and carrot) by using mixed sides, right...
-
International Biomechanics
Czasopisma -
Series on Biomechanics
Czasopisma -
Influence of meniscus shape in the cross sectional plane on the knee contact mechanics
PublikacjaWe present a three dimensional finite element analysis of stress distribution and menisci deformation in the human knee joint. The study is based on the Open Knee model with the geometry of the lateral meniscus which shows some degenerative disorders. The nonlinear analysis of the knee joint under compressive axial load is performed. We present results for intact knee, knee with partial and complete radial posterior meniscus root...
-
Biomechanics of Lumbar Spine Injury in Road Barrier Collision–Finite Element Study
PublikacjaLiterature and field data from CIREN database have shown that lumbar spine injuries occur during car crashes. There are multiple hypotheses regarding how they occur; however, there is no biomechanical explanation for these injuries during collisions with road safety barriers (RSBs). Therefore, the objective of this study was to investigate the mechanics of vertebral fractures during car collisions with concrete RSBs. The finite...
-
Evaluation of Wear Resistance of Ti alloys used for elements friction of knee endoprosthesis
PublikacjaThe paper presents research results of resistance to abrasive wear of titanium alloys: Ti6Al4V (commonly used) and Til3Nb13Zr (alloy of new generation) in association with polyethylene (UHMW-PE) predisposed for elements on pair of the knee endoprosthesis. The results were analysed from the point of possibility of an use of new generation titanium alloys as components of such implants. The tests of resistance to abrasive wear of...
-
Knee Surgery and Related Research
Czasopisma -
Biomechanical properties of 3D-printed bone models
PublikacjaBone lesions resulting from large traumas or cancer resections can be successfully treated by directly using synthetic materials or in combination with tissue engineering methods (hybrid). Synthetic or hybrid materials combined with bone tissue’s natural ability for regeneration and biological adaptation to the directions of loading, allow for full recovery of its biological functions. Increasing interest in new production methods...
-
Biomechanical causes for failure of the Physiomesh/Securestrap system
PublikacjaThis study investigates the mechanical behavior of the Physiomesh/Securestrap system, a hernia repair system used for IPOM procedures associated with high failure rates. The study involved conducting mechanical experiments and numerical simulations to investigate the mechanical behavior of the Physiomesh/Securestrap system under pressure load. Uniaxial tension tests were conducted to determine the elasticity modulus of the Physiomesh...
-
Biomechanics of the front abdominal wall as a potential factorleading to recurrence with laparoscopic ventral hernia repair
PublikacjaThis study investigated the front abdominal wallto describe its elasticity in vivo and searched for elongationsthat possibly stretched an implanted mesh, therebycausing fixation failure and subsequent recurrence.To measure front abdominal wall elongations, amodel of fascia movements was created. Eight healthyvolunteers were measured during exercise to determine theextent of elongations in their front abdominal wall. Videoswere...
-
Biomaterials and Biomechanics in Bioengineering
Czasopisma -
Molecular & Cellular Biomechanics
Czasopisma -
JOURNAL OF APPLIED BIOMECHANICS
Czasopisma -
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING
Czasopisma -
The Clinical Use of Platelet-Rich Plasma in Knee Disorders and Surgery—A Systematic Review and Meta-Analysis
Publikacja -
Geomechanics and Engineering
Czasopisma -
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
Czasopisma -
The influence of a change in the meniscus cross-sectional shape on the medio-lateral translation of the knee joint and meniscal extrusion
PublikacjaObjective The purpose of this study was to evaluate the influence of a change in the meniscus cross sectional shape on its position and on the biomechanics of a knee joint. Methods One main finite element model of a left knee joint was created on the basis of MRI images. The model consisted of bones, articular cartilages, menisci and ligaments. Eight variants of this model with an increased or decreased meniscus height were then...
-
Assessment of the Relationship between the Shape of the Lateral Meniscus and the Risk of Extrusion Based on MRI Examination of the Knee Joint
PublikacjaBackground Meniscus extrusion is a serious and relatively frequent clinical problem. For this reason the role of different risk factors for this pathology is still the subject of debate. The goal of this study was to verify the results of previous theoretical work, based on the mathematical models, regarding a relationship between the cross-section shape of the meniscus and the risk of its extrusion. Materials and Methods Knee...
-
SimMechanics package - some effective tool for pedagogical exercises in multibody dynamics.
PublikacjaW pracy skoncentrowano się na poszukiwaniach narzędzia przydatnego w procesie nauczania dynamiki układów wielomasowch. Proces ten, z natury dwuetapowy, wymaga aby klasyczne wykłady dla studentów poszerzyć o ćwiczenia komputerowe, pozwalające na samodzielne modelowanie wybranych układów. Wymaga to zastosowania oprogramowania łatwego do nauki i wykorzystania, w tym pozwalającego na szybkie modelowanie prostych mechanizmów i umożliwiającego...
-
Orbital blowout trauma occurring at the workplace – clinical, biomechanical and legal aspects
PublikacjaIntroduction and objective: Craniofacial injury at the workplace may lead to orbital blowout fractures. The aim of the study is the development of own numerical model of the eye orbit, assessment of the damage zones, and comparing them with clinical examinations. In addition, the current legal status of patients after injuries is presented Material and methods: In laboratory tests performed on bones collected from the upper and...
-
Pakiet SIMMECHANICS jako narzędzie w dydaktyce dynamiki układów wielomasowych
PublikacjaW pracy zaprezentowano oprogramowanie przydatne w procesie nauczania dynamiki układów wielomasowch. We wspomnianym procesie dydaktycznym wymagane jest, aby wykład poszerzyć o ćwiczenia komputerowe, pozwalające na samodzielne modelowanie układów omawianych na wykładzie. Poszukiwane oprogramowanie powinno wprowadzać studenta w szczegóły teorii zaczynając od zagadnień prostych, w których fragmenty bardziej złożone przywoływane są...
-
Can local infiltration analgesia supplemented with tranexamic acid reduce blood loss during total knee arthroplasty?
Publikacja -
Seismic Response Analysis of Knee-Braced Steel Frames Using Ni-Ti Shape Memory Alloys (SMAs)
PublikacjaShape Memory Alloys (SMAs) are known as active materials that can be widely used for structural purposes due to their flag-shape behavior under loading and reloading. Their unique characteristics provided a potential solution for civil engi-neers especially to model buildings with the capability of dissipating seismic en-ergy. In this study, the main purpose is to explore the seismic behavior of Knee-Braced Frames (KBFs) and...
-
Journal of Applied Biomaterials & Biomechanics
Czasopisma -
Identification of the damage mechanism in orthopaedic implant. Case study including the biomechanical analysis
Publikacja -
Wybrane bazodanowe zbiory informacji z zakresu biomechaniki, fizjologii i psychologii
PublikacjaDeponowanie wyników badań naukowych – zarówno opracowanych, jak też tzw. surowych danych – odbywa się pod wieloma postaciami, poprzez zamieszczanie w repozytoriach danych badawczych, umieszczanie wyników w publikacjach, które są następnie indeksowane na platformach czasopism, w bazach bibliograficzno-abstraktowych. Niektóre czasopisma funkcjonujące w obiegu międzynarodowym wymagają od autorów dołączania do artykułów także zbiorów...
-
Biomechanical testing of bioactive bone cements – a comparison of the impact of modifiers: antibiotics and nanometals
PublikacjaApart from its bone filler and fracture stabilizing function, bone cement can be used as a carrier of bioactive substances, and such modified bone cement can protect the implant against microorganisms, treat local infections and combat bacteria introduced during the surgical procedure. In this paper, the effects of modifying antibiotics and nanosilver on the biomechanical properties of bone cement were examined. The following tests...
-
Mechanical Properties of Additively Manufactured Polymeric Materials—PLA and PETG—For Biomechanical Applications
PublikacjaThe study presented herein concerns the mechanical properties of two common polymers for potential biomedical applications, PLA and PETG, processed through fused filament fabrication (FFF)—Material Extrusion (ME). For the uniaxial tension tests carried out, two printing orientations—XY (Horizontal, H) and YZ (Vertical, V)—were considered according to the general principles for part positioning, coordinates, and orientation typically...
-
Efficacy of tranexamic acid supplemented with local infiltration analgesia in reducing blood loss in patients undergoing unicompartmental knee arthroplasty
Publikacja -
Efficacy of tranexamic acid supplemented with local infiltration analgesia in reducing blood loss in patients undergoing unicompartmental knee arthroplasty.
Publikacja -
INTERNATIONAL JOURNAL FOR NUMERICAL AND ANALYTICAL METHODS IN GEOMECHANICS
Czasopisma -
Cerclage cable augmentation does not increase stability of the fixation of intertrochanteric fractures. A biomechanical study
PublikacjaBackground: Intertrochanteric fractures with a posteromedial intermediate fragment are unstable because of the loss of medial support. Additional fixation with a cerclage is used in subtrochanteric fractures, but not in intertrochanteric fractures. The aim of this biomechanical study is to evaluate whether cerclage fixation improves stability of intertrochanteric fractures. Hypothesis: Our hypothesis is that the cerclage fixation...
-
Australian Geomechanics Journal
Czasopisma -
International Journal of Geomechanics
Czasopisma