Filters
total: 599
filtered: 578
Search results for: REVERSED PHASE LIQUID CHROMATOGRAPHY
-
A headspace solid-phase microextraction method development and itsapplication in the determination of volatiles in honeys by gas chromatography
PublicationThe first part of the paper presents the detailed optimisation of all steps of the determination procedureof volatiles from Polish honeys by headspace solid-phase microextraction (HS-SPME) as the sample preparationmethod and gas chromatography/mass spectrometry (GC-MS) as the method of final determination.The methodology of semi-quantative analysis allowed the isolation and identification of volatile fractioncompounds from popular...
-
Comparison of classical and modern approach of determination of highly polar compounds by High Performance Liquid Chromatography coupled with Tandem Mass Spectrometry
PublicationAbstract: Sugars and sugar alcohols are known as highly polar compounds. Four analytes were taken into consideration for comparison of classical and modern approach of separation of highly polar substances. Mannitol was chosen as an example of simple sugar alcohol, sucrose and lactulose as examples of disaccharides and structural isomers, raffinose as an example of complex trisaccharide. Raffinose was also used as internal standard...
-
Free silanols and ionic liquids as their suppressors in liquid chromatography
Publication -
Calixarenes as stationary phases in High Performance Liquid Chromatography
PublicationPraca przeglądowa przedstawia dotychczasowe metody syntezy faz stacjonarnych na bazie pochodnych kaliksarenów, kaliksrezorcyarenów i kalikspiroli chemicznie ziązanych z żelem krzemionkowym lub dynamicznie na nim obsadzonych. Podsumowano zastosowanie tych faz w rozdzielaniu szeregu klas związków organicznych i nieorganicznych metodą wysokosprawnej chromatografii cieczowej.
-
Sensitive determination of isoprostanes in exhaled breath condensate samples with use of liquid chromatography-tandem mass spectrometry
PublicationOxidative stress is the hallmark of various inflammatory lung diseases. Increased concentrations of reactive oxygen species in the lungs are reflected by elevated concentrations of oxidative stress markers in the breath, airways, lung tissue and blood. The aim of this work was to develop a method for the fast measurement of F2 isoprostanes in exhaled breath condensate (EBC) samples using equipment which is nowadays available and...
-
The presence of polycyclic aromatic hydrocarbons in disposable baby diapers: A facile determination method via salting-out assisted liquid-liquid extraction coupled with gas chromatography-mass spectrometry
PublicationIn this paper we demonstrate the development of the extraction procedure of polycyclic aromatic hy- drocarbons from baby diapers along with their quantification by gas chromatography-mass spectrometry. Apart from covering plastic foil, disposable baby diapers contain sorbents intended to absorb urine and feces. A hygroscopic, adsorptive, and tough-to-homogenize fibrous sorbent, represents an analytical chal- lenge to analytical...
-
Comparison of noise reduction methods in radiometric correlation measurements of two-phase liquid-gas flows
PublicationTwo-phase liquid-gas flows occur frequently in the mining, energy, chemical, and petrochemical industries. One of non-contact methods used to analyse these flows is the gamma ray absorption method. However, the signals received from radiation detectors contain a significant stochastic noise, which makes them difficult to analyse. The article describes four methods of noise reduction in cross-correlation measurements of water-air...
-
In-Syringe Dispersive Liquid-Liquid Microextraction Coupled with High- Performance Liquid Chromatography for Trace Analysis of Naphthalene Sulfonates in Seawater
Publication -
Diverse roles, advantages and importance of deep eutectic solvents application in solid and liquid-phase microextraction techniques – A review
PublicationDeep eutectic solvents (DESs) are an emerging class of promising green solvents used as an alternative to traditional organic solvents in various scientific fields. The high biodegradability, biocompatibility, eco-friendliness, tunable properties, and presence of active groups in DESs make them the preferred solvent in a variety of solid- and liquid-phase microextraction techniques. Aside from these benefits, the use of DESs in...
-
Determination of nine high-intensity sweeteners in various foods by high-performance liquid chromatography with mass spectrometric detection
PublicationAn analytical procedure involving solid-phase extraction (SPE) and high-performance liquid chromatography-mass spectrometry has been developed for the determination of nine high-intensity sweeteners authorised in the EU; acesulfame-K (ACS-K), aspartame (ASP), alitame (ALI), cyclamate (CYC), dulcin (DUL), neohesperidin dihydrochalcone (NHDC), neotame (NEO), saccharin (SAC) and sucralose (SCL) in a variety of food samples (i.e. beverages,...
-
Effectiveness of toluene separation from gas phase using supported ammonium ionic liquid membrane
PublicationAmmonium ionic liquids (ILs) are relatively cheap in synthesis and environmentally benign and despite that they have been very rarely used in gas separation. In this research we used several ammonium ILs as liquid membranes for removal of residual toluene from gas phase. Ionic liquids used in this study were composed of bis(trifluoromethylsulfonyl)imide anion [Tf2N] and trimethylbutylammonium [N1114], trietylbutylammonium [N2224],...
-
Comprehensive determination of flavouring additives and nicotine in e-cigarette refill solutions. Part I: Liquid chromatography-tandem mass spectrometry analysis
PublicationLiquid chromatography-tandem mass spectrometry with electrospray ionization (HPLC-ESI–MS/MS) methods were developed for the simultaneous determination of 42 flavouring compounds and nicotine in liquids for e-cigarettes. The chromatographic separation was performed using an Ace® Ultracore™ SuperC18™ (100 × 2.1 mm, 2.5 μm) column in both acidic and alkaline pH conditions to separate all the compounds. A simple “dilute & shoot” approach...
-
Development of a liquid chromatography–tandem mass spectrometryprocedure for determination of endocrine disrupting compounds infish from Mediterranean rivers
PublicationA new, sensitive and rapid method based on QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe)approach followed by ultra high performance liquid chromatography coupled with tandem mass spec-trometry (UHPLC–MS/MS) was developed for the determination of nineteen endocrine disruptors (EDCs)and related compounds belonging to different classes in various fish species. Matrix effect on the analyti-cal performance was evaluated,...
-
pH gradient high-performance liquid chromatography: theory and applications
Publication -
Direct solid phase microextraction combined with gas chromatography – Mass spectrometry for the determination of biogenic amines in wine
PublicationA direct method based on immersion solid phase microextraction (DI-SPME) gas chromatography mass-spectrometry (GC-MS) was optimized and validated for the determination of 16 biogenic amines in Polish wines. In the analysis two internal standards were used: 1,7-diaminoheptane and bis-3-aminopropylamine. The method allows for simultaneous extraction and derivatization, providing a simple and fast mode of extraction and enrichment....
-
Phenomenon of hydraulic jump formed on liquid layer by single-phase impinging liquid jet
PublicationPrzedstawiono analizę teoretyczną zjawiska uskoku hydraulicznego tworzonego przez uderzającą strugę. rezultaty analizy teoretycznej porównano z wynikami badań eksperymentalnych.
-
Origin of the liquid-liquid phase transition for trans-1,2-dichloroethylene observed by IR spectroscopy
Publication -
Determination of five sulfonamides in medicated feedingstuffs by liquid chromatography with ultraviolet detection
Publication -
Amphenicols stability in medicated feed – development and validation of liquid chromatography method
Publication -
The simultaneous determination of hydrophobicity and dissociation constant by liquid chromatography–mass spectrometry
Publication -
Quantitative structure–retention relationships in affinity high-performance liquid chromatography
Publication -
Determination of antifreeze substances in the airport runoff waters by solid-phase microextraction and gas chromatography–mass spectrometry method
PublicationA new method has been developed for the determination of antifreeze agents such as ethylene glycol (EG), propylene glycol (PG), and diethylene glycol (DEG) in the samples of airport runoff water. The method is based on headspace solid–phase microextraction (HS–SPME) of target analytes, which is coupled with gas chromatography–mass spectrometry (GC–MS). Until now, there was a lack of appropriate methodology for collecting reliable...
-
First deep eutectic solvent-based (DES) stationary phase for gas chromatography and future perspectives for DES application in separation techniques
PublicationThe paper presents the first application of deep eutectic solvents (DES) as stationary phases for gas chromatography. DES obtained by mixing tetrabutylammonium chloride (TBAC) as a hydrogen bond acceptor (HBA) with heptadecanoic acid being a hydrogen bond donor (HBD) in a mole ratio of HBA:HBD equal to 1:2 was characterized by its ability to separate volatile organic compounds (VOCs). The Rohrschneider – McReynolds constants determined...
-
Application of dispersive liquid-liquid microextraction for the determination of selected organochlorine pesticides in honey by gas chromatography - mass spectrometry
PublicationDispersive liquid-liquid microextraction (DLLME) is a rapid and easy technique that consumes minute amounts of organic solvents. In this work, we present chemometric study on optimization of DLLME parameters for the extraction of aldrin, endrin, lindane, alfa-endosulfan, 4,4'-DDT and its metabolites from honey matrix. Method quantification limits (MQLs) vary between 0.3 ng/g for 2,4'-DDE and 4,4'-DDE to 13.2 ng/g for alfa-endosulfan...
-
Application of Headspace Solid-phase Microextraction with Poly(1-vinyl-3- Hexylimidazolium Chloride) Polymeric Ionic Liquid Coating using GC - MS to Determine Volatile Fatty Acids in Dairy Wastewater
PublicationVolatile fatty acids were determined in this study using headspace solid-phase microextraction (HS-SPME) with a poly(1-vinyl-3-hexylimidazolium chloride) polymeric ionic liquid coated fiber followed by gas chromatography - mass spectrometry. Experimental parameters such as extraction time and temperature, sample volume as well as desorption time and temperature were optimized. Detection limits of the method were in the range of...
-
Monolithic capsule phase microextraction prior to gas chromatography-mass spectrometry for the determination of organochlorine pesticides in environmental water samples
PublicationIn this study, a capsule phase microextraction (CPME) protocol followed by gas chromatography-mass spectrometry is proposed for the accurate and sensitive monitoring of organochlorine pesticides (OCPs) in environmental water samples. Different monolithic sol–gel encapsulated sorbents were compared and monolithic sol–gel poly(ethylene glycol)-based sorbent incorporated into porous microextraction capsules resulted in the highest...
-
Fast, sensitive and reliable multi-residue method for routine determination of 34 pesticides from various chemical groups in water samples by using dispersive liquid – liquid microextraction coupled with gas chromatography – mass spectrometry
PublicationA simple and efficient dispersive liquid-liquid microextraction technique (DLLME) was developed by using a mixture of two solvents: 40 μL of tetrachlorethylene (extraction solvent) and 1.0 mL of methanol (disperser solvent), which was rapidly injected with a syringe into 10mL ofwater sample. Some important parameters affecting the extraction efficiency, such as type and volume of solvents, water sample volume, extraction time,...
-
Rapid ion-exchange matrix removal for a decrease of detection limits in the analysis of salt-rich reservoir waters for fluorobenzoic acids by liquid chromatography coupled with tandem mass spectrometry
PublicationA matrix removal procedure with ion-exchange resin prior to analysis for 18 fluorinated benzoic acids (FBAs) tracers in saline (>25% salt) reservoir water was optimized. The elimination of >98% of salt and the simultaneous matrix sample cleanup allowed the direct analysis using the supernatant by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). This resulted in a gain in detection limits for most of the tracers...
-
Determination of trace levels of eleven bisphenol A analogues in human blood serum by high performance liquid chromatography–tandem mass spectrometry
PublicationChemicals showing structural or functional similarity to bisphenol A (BPA), commonly called BPA analogues, have recently drawn scientific attention due to their common industrial and commercial application as a substitute for BPA. In the European Union, the use of BPA has been severely restricted by law due to its endocrine disrupting properties. Unfortunately, it seems that all BPA analogues show comparable biological activity,...
-
Chemically Bonded Silica Stationary Phases: Synthesis, Physicochemical Characterization, and Molecular Mechanism of Reversed-Phase HPLC Retention
Publication -
Determination of fluoride as fluorosilane derivative using reversed-phase HPLC with UV detection for determination of total organic fluorine
Publication -
DETERMINATION OF POLYCYCLIC AROMATIC HYDROCARBONS IN SOIL SAMPLES USING ULTRASONIC PROBE AND SALT-ASSISTED LIQUID-LIQUID EXTRACTION COUPLED WITH HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
Publication -
Micellar liquid chromatography for lipophilicity determination of new biologically active 1,3‐purinodiones
Publication -
High resolution liquid chromatography and time of flight mass spectrometry in perfume analysis
PublicationPerfumes consist of a wide range of natural and synthetic compounds that belongs to different chemical classes. Most of these compounds are generally determined by GC. However, in this study RP-HPLC-Q-TOF-MS and HILIC-Q-TOF-MS technique was applied for the determination of ingredients of original perfumes and their imitations. Antioxidants and compounds specific to fragrances of animal \origin were found in original...
-
Stability of liquid film formed due to impingement of a two-phase jet
PublicationPrzedstawiono analizę teoretyczną i badania eksperymentalne zjawiska rozrywania się warstwy cieczy powstałej na powierzchni ciała stałego z uderzającej strugi.
-
Thermotropic Biaxial Nematic Phase in Liquid Crystalline Organo-Siloxane Tetrapodes
Publication -
Mechanism of a Four-Phase Liquid Membrane Oscillator Containing Hexadecyltrimethylammonium Bromide
PublicationBadano zachowanie nitrometanowego oscylatora z membraną ciekłą zawierającego kationowy surfaktant. Początkowo układ składał się z trzech faz: wodnej donorowej zawierającej surfaktant i etanol, membrany ciekłej (kwas pikrynowy w nitrometanie) oraz fazy wodnej akceptorowej zawierającej sacharozę. Podczas procesu oscylacyjnego wytwarzała się nowa fazą X między membraną ciekłą, a fazą akceptorową. Stwierdzono oscylacje różnicy potencjału...
-
Recent theoretical and practical applications of micellar liquid chromatography (MLC) in pharmaceutical and biomedical analysis
Publication -
High Performance Liquid chromatography - Fourier Transform Infrared Spectroscopy Coupling: A Comprehensive Review
Publication -
Liquid chromatography tandem mass spectrometry study of urinary nucleosides as potential cancer markers
Publication -
Suppression of deleterious effects of free silanols in liquid chromatography by imidazolium tetrafluoroborate ionic liquids
Publication -
Comparative study of surface topography of high performance liquid chromatography columns in terms of hydrophobicity
Publication -
Characterization of In Vitro and In Vivo Metabolism of Antazoline Using Liquid Chromatography-Tandem Mass Spectrometry
Publication -
Troubleshooting of the determination of bisphenol A at ultra-trace levels by liquid chromatography and tandem mass spectrometry
PublicationDetermination of trace amounts of bisphenol A (BPA) may cause problems mainly related to the presence of BPA in solvents (even in LC-MS grade), laboratory vessels, and plastic equipment used for sample preparation. Variable and sometimes significant amounts of BPA present in the background cause problems in obtaining good repeatability of measurements at the ultra-trace levels. Such observations (i.e., poor repeatability of results)...
-
Rapid and Green Separation of Mono- and Diesters of Monochloropropanediols by Ultrahigh Performance Supercritical Fluid Chromatography–Mass Spectrometry Using Neat Carbon Dioxide as a Mobile Phase
PublicationThis study demonstrates the effect of column selectivity and density of supercritical carbon dioxide (SC-CO2) on the separation of monochloropropanediol (MCPD) esters, known as food toxicants, using SC-CO2 without addition of cosolvent in ultrahigh performance supercritical fluid chromatography–mass spectrometry (UHPSFC-MS). This study shows that over 20 2-monochloropropanediol (2-MCPD) and 3-monochloropropanediol (3-MCPD) mono-...
-
Solid phase microextraction–comprehensive twodimensional gas chromatography–time-of-flight mass spectrometry: a new tool for determining PAHs in airport runoff water samples
Publicationfundamental aspect of airport operations is the pollution caused by airport runoff waters. Polycyclic aromatic hydrocarbons (PAHs) are one of the most important groups of xenobiotics which are commonly found in runoff water originating from airports. Only very limited data on the analysis of airport runoff water have been published until now. Therefore, a reliable and accurate analytical method based on headspace solid-phase microextraction...
-
Novel liquid chromatography method based on linear weighted regression for the fast determination of isoprostane isomers in plasma samples using sensitive tandem mass spectrometry detection
PublicationA simple, fast, sensitive and accurate methodology based on a LLE followed by liquid chromatography–tandem mass spectrometry for simultaneous determination of four regioisomers (8-iso prostaglandin F2α, 8-iso-15(R)-prostaglandin F2α, 11β-prostaglandin F2α, 15(R)-prostaglandin F2α) in routine analysis of human plasma samples was developed. Isoprostanes are stable products of arachidonic acid peroxidation and are regarded as the...
-
Ultrasound assisted solvent extraction of porous membrane-packed samples followed by liquid chromatography-tandem mass spectrometry for determination of BADGE, BFDGE and their derivatives in packed vegetables
PublicationThe problem of the presence of trace organic pollutants in food is of growing importance due to increasing awareness about their impact on newborns, infants and adults of reproductive age. Despite the fact that packaged food products offer many advantages, packaging can be a source of contamination for stored food. Thus, monitoring such pollution in food is of high importance. In this work, a novel methodology based on the solvent...
-
Balance of pesticides mass in gas, liquid and solid phase after their chemical degradation.
PublicationOpisano metodę usuwania pestycydów z wody przy zastosowaniu fotodegradacji (UV) i katalizatora (TiO2). Efektywność procesu usuwania pestycydów była kontrolowana przy zastosowaniu chromatografu gazowego z detektorem wychwytu elektronów. Oznaczano zawartość pestycydów w wodzie, a także zaadsorbowanych na powierzchni stałej, oraz w fazie gazowej. Największa zawartość pestycydów znajdowała się na fazie stałej, następnie w cieczy i...
-
Silicon polypodands: a new class of efficient solid–liquid phase-transfer catalysts
Publication