Filters
total: 34
Search results for: ODOUR INTERACTIONS
-
Determination of Odour Interactions of Three-Component Gas Mixtures Using an Electronic Nose
PublicationThe paper presents an application of an electronic nose prototype comprised of six TGS-type sensors and one PID-type sensor to identify odour interaction phenomena in odorous three-component mixtures. The investigation encompassed eight odorous mixtures—toluene-acetone-triethylamine and formaldehyde-butyric acid-pinene — characterized by different odour intensity and hedonic tone. A principal component regression (PCR) calibration...
-
Analysis of odour interactions in model gas mixtures using electronic nose and fuzzy logic
PublicationMeasurement and monitoring of air quality in terms of odour nuisance is an important problem. Although the source of these nuisances is different (e.g. wastewater treatment plants, municipal landfills), their common feature is that they are a complex mixture of odorants with different odour thresholds. An additional problem is occurrence of the odour interactions between mixture components. From a practical point of view, it would...
-
Determination of Odour Interactions in Gaseous Mixtures Using Electronic Nose Methods with Artificial Neural Networks
PublicationThis paper presents application of an electronic nose prototype comprised of eight sensors, five TGS-type sensors, two electrochemical sensors and one PID-type sensor, to identify odour interaction phenomenon in two-, three-, four- and five-component odorous mixtures. Typical chemical compounds, such as toluene, acetone, triethylamine, α-pinene and n-butanol, present near municipal landfills and sewage treatment plants were subjected...
-
Determination of odour concentration by TD-GC×GC–TOF-MS and field olfactometry techniques
PublicationField olfactometry is one of the sensory techniques used to determine odour concentration, in atmospheric air, directly in emission sources. A two-dimensional gas chromatography with time of flight mass spectrometer (GC×GC–TOF-MS) allows performing the chemical characterization of various groups of chemical compounds, even in complex mixtures. Application of these techniques enabled determination of odour concentration level in...
-
Application of Electronic Nose to Ambient Air Quality Evaluation With Respect to Odour Nuisance in Vicinity of Municipal Landfills and Sewage Treatment
PublicationThis chapter contains information about application of the electronic nose type instruments to evaluation of ambient air odour quality connected with such sectors of human activity as municipal landfills or sewage treatment plants. The authors present potential sources of emission from these sectors, characterize the chemical compounds responsible for presence of unpleasant odours, describe the influence of those compounds on human...
-
A case study of odour nuisance evaluation in the context of integrated urban planning
PublicationOdour nuisance poses a serious problem in many urban areas, yet its evaluation and mitigation is often omitted in the urban planning process. By identifying its range and spatio-temporal variations, it could be taken into consideration by planners in urban development strategies and land use decisions. The aim of the study was to present the application of odour evaluation techniques in the improvement of the quality of life in...
-
Odour Perception Using a Sniffing Team at a Municipal Solid Waste Treatment Plant: A Case Study
PublicationThe monitoring of odour intensity, generated by a landfill area, is a difficult activity since it is a multi-source problem with discontinuous odour emissions. A modified sniffing team method is described here and applied to determine the main odour sources in a landfill located in Pomerania, Poland. Four consecutive test sessions were performed during the following months: August, December, April, and June. It was found that the...
-
IDENTIFICATION OF ODOR OF VOLATILE ORGANIC COMPOUNDS USING CLASSICAL SENSORY ANALYSIS AND ELECTRONIC NOSE TECHNIQUE
PublicationThe paper compares two methods of analysis of odour of volatile organic compounds: classical sensory analysis and electronic nose technique. Eight volunteers participated in the classical sensory analysis investigations, which lasted two weeks. An instrumental odour analysis involved a prototype of 6-sensor electronic nose designed by the authors. The research performed with this device provided higher reproducibility and reliability...
-
Evaluation of Health Hazard Due to Emission of Volatile Organic Compounds from Various Processing Units of Wastewater Treatment Plant
PublicationThe paper describes an attempt at health risk assessment and odour concentration determination in the most important units of a wastewater treatment plant. The cancer risk (CR) and hazard index (HI) parameters in selected measurement locations were calculated based on the results of chromatographic analyses (GCxGC-TOF-MS) and the United States Environmental Protection Agency (US EPA) guidelines. No exceedance of the CR and HI acceptable...
-
Different Ways to Apply a Measurement Instrument of E-Nose Type to Evaluate Ambient Air Quality with Respect to Odour Nuisance in a Vicinity of Municipal Processing Plants
PublicationThis review paper presents different ways to apply a measurement instrument of e-nose type to evaluate ambient air with respect to detection of the odorants characterized by unpleasant odour in a vicinity of municipal processing plants. An emphasis was put on the following applications of the electronic nose instruments: monitoring networks, remote controlled robots and drones as well as portable devices. Moreover, this paper presents...
-
Instrumental measurement of odour nuisance in city agglomeration using electronic nose
PublicationThe paper describes an operation principle of odour nuisance monitoring network in a city agglomeration. Moreover, it presents the results of investigation on ambient air quality with respect to odour obtained during six-month period. The investigation was carried out using a network comprised of six prototypes of electronic nose and Nasal Ranger field olfactometers employed as a reference method. The monitoring network consisted...
-
Complementary use of GCxGC–TOF–MS and statistics for differentiation of variety in biosolid samples
PublicationFormation of biosolid cakes, which are one of the main wastes generated in wastewater treatment plants, is connected with emission of many hazardous chemical compounds, including odoriferous ones. To optimize particular processes of biosolid cake processing, it is necessary to assess chemical composition of the gas mixtures containing the compounds released from the cakes. The paper proposes application of two-dimensional gas chromatography...
-
Application of fuzzy logic to determine the odour intensity of model gas mixtures using electronic nose
PublicationThe paper presents the possibility of application of fuzzy logic to determine the odour intensity of model, ternary gas mixtures (α-pinene, toluene and triethylamine) using electronic nose prototype. The results obtained using fuzzy logic algorithms were compared with the values obtained using multiple linear regression (MLR) model and sensory analysis. As the results of the studies, it was found the electronic nose prototype along...
-
Bioelectronic nose: Current status and perspectives
PublicationA characteristic feature of human and animal organs of smell is the ability to identify hundreds of thousands of odours. It is accompanied by particular smell sensations, which are a basic source of information about odour mixture. The main structural elements of biological smell systems are the olfactory receptors. Small differences in a structure of odorous molecules (odorants) can lead to significant change of odour, which is...
-
Monitoring of n-butanol vapors biofiltration process using an electronic nose combined with calibration models
PublicationMalodours, by definition, are generally unpleasant, nuisance smells that are a mixture of volatile chemical compounds which can be perceptible even at low concentrations. Due to the more frequent occurrence of odour nuisance associated with the odour sensations, and thus the need to remove them from the air, deodorization techniques are commonly used. Biofiltration is one of the methods of reducing odorants in the air stream. In...
-
Biotrickling filtration of n-butanol vapors: process monitoring using electronic nose and artificial neural network
PublicationBiotrickling filtration is one of the techniques used to reduce odorants in the air. It is based on the aerobic degradation of pollutants by microorganisms located in the filter bed. The research presents the possibility of using the electronic nose prototype combined with artificial neural network for biofiltration process monitoring in terms of reduction in n-butanol concentration and odour intensity of treated air. The study...
-
Monitoring of odour nuisance in the Tricity Agglomeration
PublicationThe paper describes a principle of operation of odour nuisance monitoring network, which is being designed in the Tricity Agglomeration. Moreover, it presents the preliminary results of an investigation on ambient air quality with respect to odour nuisance in a vicinity of the municipal landfill. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The...
-
Comparison of the measurement techniques employed for evaluation of ambient air odour quality
PublicationThe paper presents the results of investigation on ambient air odour quality in a vicinity of the industrial sewage treatment plant being a part of the crude oil processing plant. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. The field...
-
Advances in olfaction-inspired biomaterials applied to bioelectronic noses
PublicationAmong all the senses, olfactory system of mammals is the least characterised as far as the mechanisms of odour identification are concerned. The results of recent investigations allow better understanding of the operation mechanism of the sense of smell. Progress in this field is crucial for the development of sensor technology based on olfaction-inspired biomaterials, which simulate the olfactory system of the biological counterparts....
-
Investigation of Air Quality beside a Municipal Landfill: The Fate of Malodour Compounds as a Model VOC
PublicationThis paper presents the results of an investigation on ambient air odour quality in the vicinity of a municipal landfill. The investigations were carried out during the spring–winter and the spring seasons using two types of the electronic nose instrument. The field olfactometers were employed to determine the mean odour concentration, which was from 2.1 to 32.2 ou/m3 depending on the measurement site and season of the year. In...
-
Monitoring of Odour Nuisance from Landfill Using Electronic Nose
PublicationThe paper presents the results of investigation on classification of atmospheric air samples collected in a vicinity of municipal landfill with respect to their odour nuisance. The research was conducted using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type –HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co.. Classification of the air samples...
-
Comparison of different types of electronic nose instruments for evaluation of odour nuisance from landfill
PublicationThe paper presents and compares the results of investigation on classification of atmospheric air samples collected in a vicinity of municipal landfill with respect to their odour nuisance. The research was conducted using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with six semiconductor sensors of TGS type. Classification of the air...
-
Comparison of Evaluation of Air Odour Quality in Vicinity of Petroleum Plant Using a Prototype of Electronic Nose Instrument and Fast GC Technique
PublicationThe paper presents the results of investigation on classification of the ambient air samples collected in a vicinity of the LOTOS Group S.A. petroleum plant with respect to odour. The investigations were carried out with an electronic nose prototype and a commercial electronic nose of Fast GC-type – HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and a photoionization sensor of PID-type....
-
Monitoring of odour nuisance on the adjacent areas to the landfill using fast GC and sensory analysis
PublicationThe paper shows the results of investigation on classification of the atmospheric air samples collected in a vicinity of the landfill during August and September period have been presented. The studies was conducted by the use of Fast GC HERACLES II from AlphaMOS company and sensory analysis. About 86% of the atmospheric air samples ollected were classified correctly using PCA and LDA. Based on a classification of the atmospheric...
-
Direct measurements of odorous volatile organic compounds present in biosolids cakes by Proton Transfer Reaction – Mass Spectrometry Technique
PublicationThis paper show the results of investigation of concentration of odorous chemical compounds emitted upon ageing of anaerobically stabilised biosolids that could contribute to the overall odour character of nuisance emissions. Biosolids samples from wastewater treatment plant were collected in spring time. Concentrations of volatile organic compounds using a US EPA flux hood and Proton Transfer Reaction-Time of Flight-Mass Spectrometry...
-
Treatment of malodorous air in biotrickling filters: A review
PublicationOdour nuisance, resulting mainly from the presence of the compounds containing osmophore group and characterized by low olfactory threshold, is associated with danger and may be the cause of negative psychosomatic symptoms. Among different methods of malodorous air treatment, biological methods are of importance, mainly due to reduced operating costs, high purification efficiency of voluminous gas streams characterized by low concentrations...
-
The application of environmental issues in designing urban structures – a framework for comprehensive local planning policies
PublicationThe implementation of environmental issues in planning and designing urban structures is becoming a novel approach and a common practice consistent with the paradigm of sustainable development. Maintaining environmental quality in urban areas, managing natural resources and understanding the complexity of urban systems is becoming increasingly challenging. Therefore, it is important to develop strategies for the integration of...
-
Discrimination of selected fungi species based on their odour profile using prototypes of electronic nose instruments
PublicationThe paper presents practical application of an electronic nose technique to fast and efficient discrimination of the samples of different fungi species such as: Penicillium chrysogenum, Cladosporium herbarum, Rhizopus oryzae, Alternaria alternata. Two prototypes of electronic nose instrument were utilized for investigation of discrimination capability with respect to odour profile of these fungi: the first prototype was based on...
-
Bio-inspired approaches for explosives detection
PublicationDue to unique abilities of the animals regarding analysis of complex gas substances, they still remain a gold standard in analysis of explosives. Unusual capabilities of biological chemosensory systems, including both vertebrates and invertebrates, stimulate elaboration of the devices mimicking their activity and operation parameters as precisely as possible. The electronic analogues are a subject of investigation in many research...
-
Electronic nose algorithm design using classical system identification for odour intensity detection
PublicationThe two elements considered crucial for constructing an efficient environmental odour intensity monitoring systems are sensors and algorithms typically addressed to as electronic nose sensor (e-nose). Due to operational complexity of biochemical sensors developed in human bodies algorithms based on computational methods of artificial intelligence are typically considered superior to classical model based approaches in development...
-
Evaluation of the photoprotective effect of β-cyclodextrin on the emission of volatile degradation products of ranitidine
PublicationThe process of the photo-excitation of ranitidine hydrochloride (RAN) in a solid state makes visible changes to its colour and generates an unpleasant odour. The purpose of the present study was to observe the protective effects of ˇ-cyclodextrin (CD) complexation as well as the effect of the mixture of two stoichiometries 1:1 and 1:2 (RAN:CD, IC) on the photostability of samples in a solid state. Samples of inclusion complexes...
-
Evaluation of the photoprotective effect of ˇ-cyclodextrin on the emission of volatile degradation products of ranitidine
PublicationThe process of the photo-excitation of ranitidine hydrochloride (RAN) in a solid state makes visible changes to its colour and generates an unpleasant odour. The purpose of the present study was to observe the protective effects of ˇ-cyclodextrin (CD) complexation as well as the effect of the mixture of two stoichiometries 1:1 and 1:2 (RAN:CD, IC) on the photostability of samples in a solid state. Sam- ples of inclusion complexes...
-
Differences between selected volatile aromatic compound concentrations in sludge samples in various steps of wastewater treatment plant operations
PublicationSewage sludge, one of the main wastes generated during wastewater treatment, constitutes an important source of emissions of volatile chemical compounds such as volatile aromatic compounds These substances may undergo various changes as a result of operations and unit processes, which affects their concentrations in sewage sludge. An important factor determining the potential hazardousness of volatile organic compounds is the quality...
-
Determination of Odor Intensity of Binary Gas Mixtures Using Perceptual Models and an Electronic Nose Combined with Fuzzy Logic
PublicationMeasurement and monitoring of air quality in terms of odor nuisance is an important problem. From a practical point of view, it would be most valuable to directly link the odor intensity with the results of analytical air monitoring. Such a solution is offered by electronic noses, which thanks to the possibility of holistic analysis of the gas sample, allow estimation of the odor intensity of the gas mixture. The biggest problem...