Search results for: power transformer
-
Implementation of power transformer controlled switching algorithm
PublicationThe article presents two new algorithms of controlled switching the power transformer. The main aim of the paper is to obtain formulas that determine the moments of closing of the circuit breaker poles. The study contains projects of control systems for both algorithms. Mathematical formulas for the time instants of the breaker poles closing were developed on the basis of electric circuit theory and magnetic circuit theory. The...
-
Demagnetization of the core and reduction of power transformer inrush current
PublicationW artykule przedstawiono metodę ograniczenia prądów włączania transformatora energetycznego za pomocą demagnetyzacji rdzenia magnetycznego. Jako źródło energii do demagnetyzacji w proponowanej metodzie zastosowano kondensator. Do wytworzenia pola rozmagnesowującego wykorzystano uzwojenia robocze transformatora. Przeprowadzono obliczenia magnetyzmu szczątkowego rdzenia po demagnetyzacji dla różnych wartości pojemności, napięcia...
-
Propagation Characteristics of Partial Discharges in an Oil-Filled Power Transformer
PublicationPower transformers are among the most important assets in the power transmission and distribution grid. However, they suffer from degradation and possible faults causing major electrical and financial losses. Partial discharges (PDs) are used to identify the insulation health status and their degradation level. PDs are incipient, low-magnitude faults caused by localized dielectric breakdown. Those activities emit signals in many...
-
Simplified saturation modelling in three-leg power transformer for the system stability analisys
PublicationThe paper presents a simplified method for modelling non-linearity of the magnetic circuit of the power transformer. The saturation effect is implemented by describing the self and mutual inductances as a function of the magnetic flux. The most important element of this function is the saturation coefficient which is calculated based on transient state during the unloaded transformer switch on. The transformer model is described...
-
Activity coordination of capacitor banks and power transformer controllers in order to reduce power losses in the MV grid
PublicationOne of the main issues related to the optimization of the MV (middle voltage) network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility...
-
Adaptive Algorithm of a Tap-Changer Controller of the Power Transformer Supplying the Radial Network Reducing the Risk of Voltage Collapse
Publicationhe development of renewable energy, including wind farms, photovoltaic farms as well as prosumer installations, and the development of electromobility pose new challenges for network operators. The results of these changes are, among others, the change of network load profiles and load flows determining greater volatility of voltages. Most of the proposed solutions do not assume a change of the transformer regulator algorithm....
-
SVC and power transformers controllers coordination
PublicationThe use of shunt compensators such as FACTS (for example SVC) in power systems gives possibility of fast and flexible control of voltage or reactive power. An efficient cooperation between a transformer and compensator connected to busbars, or transformer’s tertiary winding, requires a proper coordination of controls. The article contains theoretical considerations and simulation results which indicate that such co-ordination is...
-
High frequency test measurements on physical model of power transformer with use of FRAX analyzer Streszczenie. W niniejszym artykule przedstawiono pomiary testowe SFRA wykonane na modelu fizycznym transformatora elektroenergetycznego
Publication -
Power Electronic Transformer For Smart Grid Application
PublicationIn this paper the control system of Power Electronic Transformer (PET) for the Smart Grid application is proposed. The structure of PET is based on two Cascaded H-bridge (CHB) converters. The electrical energy is transferred between converters using Dual-Active-Bridges (DAB) and high-frequency transformers. This type of coupling has been used to connect the DC-links of all H-bridges. The proposed control system for PET makes it...
-
A simple modular active power electronic transformer
Publication -
Design of a simple modular active power electronic transformer
Publication -
Design and evaluation of a base module of active power electronic transformer
PublicationThis paper presents an active power electronic transformer (APET) based on modular structure. The proposed three phase APET consists of at least three base modules (BM). The input/output stage of the BM is based on half-bridge sub modules. The isolation stage includes a medium frequency transformer and is realized as a dual half-bridge. The paper describes construction process and explains the control strategy. The theoretical...
-
Power electronic transformer based on cascaded H-bridge converter
PublicationIn this paper the control strategy of power electronic transformer (PET) is proposed. The analyzed structure of PET uses two seven-level cascaded H-bridge (CHB) rectifiers. The electrical power of PET is transferred between DC-links of CHB converters using dual-active-bridges (DABs) and low voltage high frequency transformers. The roposed solution allows for controlling the active and reactive power with a low level of harmonic...
-
Design and evaluation of a base module of active power electronic transformer
Publication -
Single-phase power electronics transformer with active functions for smart grid
PublicationThis paper presents the control of one cell of a modular single-phase power electronics transformer with active functions for meeting the smart grid concept. In this way, the converter could be used not only as a conventional transformer but also for grid such as reactive power, harmonic elimination and energy storage. The topology of the cell is composed by a bidirectional converter with three stages: a half bridge in the input...
-
Modelling of Voltage Transformer Performance in Power System Harmonic Frequency Range
PublicationZniekształcenia harmoniczne napięć i prądów występujące we współczesnych systemach energetycznych powodują liczne problemy pomiarowe. W referacie przedstawiono analizę właściwości przekładników napięciowych stosowanych w sieciach SN i WN w zakresie częstotliwości mierzonych zniekształceń harmonicznych. Opracowany szerokopasmowy model obwodowy został zweryfikowany symulacyjnie i eksperymentalnie. Wyniki przeprowadzonych badań potwierdzają...
-
Modelling of voltage transformer performance in power system harmonic frequency range
PublicationZniekształcenia harmoniczne napięć i prądów występujące we współczesnych systemach energetycznych powodują liczne problemy pomiarowe. W referacie przedstawiono analizę właściwości przekładników napięciowych stosowanych w sieciach SN i WN w zakresie częstotliwości mierzonych zniekształceń harmonicznych. Opracowany szerokopasmowy model obwodowy został zweryfikowany symulacyjnie i eksperymentalnie. Wyniki przeprowadzonych badań potwierdzają...
-
Single-phase power electronics transformer with active functions for smart grid
Publication -
A Combined TOPSIS and FA Based Strategic Analysis of Technical Condition of High Power Transformers
PublicationThe paper presents mathematical model { TOPSIS method, which was utilized on insulating state of distribution transformer to analyze and sensibility of individual measurements methods mutual comparison. We can uniquely determine the importance of these measurements methods with this mathematical appara- tus in these measurements methods in insulating state of transformers.
-
Determination of Complex Permeability of Silicon Steel for Use in High-Frequency Modeling of Power Transformers
Publication -
SiC-Based Power Electronic Traction Transformer (PETT) for 3 kV DC Rail Traction
PublicationThe design of rolling stock plays a key role in the attractiveness of the rail transport. Train design must strictly meet the requirements of rail operators to ensure high quality and cost-eective services. Semiconductor power devices made from silicon carbide (SiC) have reached a level of technology enabling their widespread use in traction power converters. SiC transistors oering energy savings, quieter operation, improved reliability...
-
Selected aspects of traction transformer diagnosis based on analysis of power looses in windings and the iron core
PublicationW rozdziale przedstawiono metodę diagnostyki detekcji uszkodzeń wewnętrznych uzwojeń transformatora trakcyjnego oparta na analizie strat mocy rozpraszanej wewnątrz transformatora. Straty mocy są powiekszane o szereg czynników świadczacych o uszkodzeniu transformatora takich jak: zwarcia zwojowe, asymetria uzwojeń, relaksacja naprężeń na stykach połaczeń, uszkodzenie izolacji pomiedzy blachami rdzenia itp. Proponowana metoda dokonuje...
-
NPC assessment in insulated DC/DC converter topologies using SiC MOSFETs for Power Electronic Traction Transformer
Publication -
Structure and the space vector modulation for a medium-voltage power-electronic-transformer based on two seven-level cascade H-bridge inverters
PublicationThis study presents the structure and the space vector pulse-width modulation (SVPWM) for power electronic transformer (PET) based on two seven-level cascade H-bridge (CHB) inverters. The DC links of CHB inverters are coupled with nine dual-active bridge (DAB) converters with medium-frequency transformers. The DC-link voltages are equalised with two methods – through the control of DAB voltages...
-
Measurements of no-load and short-circuit parameters of power transformers with taps
Open Research Data1) The Laboratory LINTE^2 is a large research infrastructure operated by the Faculty of Electrical and Control Engineering at Gdańsk University of Technology, to be found in Gdańsk, Poland (54.3690 N, 18.6130 E).
-
Frequency Diagnostics of Transformer Insulating Parameters
PublicationIn the article is presented experimental analysis and diagnostics of insulating system oil-paper for power transformers, mainly by progressive frequency method – dielectric spectroscopy. In the 1-st part of the article is described base theory about measurement and diagnostics insulating part (oil and paper) of power transformers. In the 2-nd part of article is described measuring method of insulating frequency diagnostics - frequency...
-
A method of nonlinearities of transformer no-load characteristic modelling
PublicationA way in which changes of the no-load characteristic are taken into account in the mathematical model of the transformer is presented. Changes of saturation within core of transformer are presented as a combined non-linear flux curve. Analysis of magnetization of the transformer core and simulation of no-load state for distribution transformer of 30 kVA power rating and 15.75/0.4 kV/kV (especially supplying VLV) transformation...
-
Hysteresis modelling of a medium frequency single-phase transformer
PublicationThe article describes a feedback Preisach hysteresis model equivalent circuit implementation of a medium frequency single-phase transformer being a part of a high power and high efficiency DC-DC converter. The macroscopic models of magnetic hysteresis are introduced and the feedback Preisach model is selected for further analysis. The hysteresis model is developed for a prototype transformer and the hysteresis loops are compared...
-
Low Current Transformer Utilizing Co-Based Amorphous Alloys
PublicationMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
Low current transformer utilizing Co-based amorphous alloys
PublicationMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
Multi-Transformer Flyback Converter for Supplying Isolated IGBT and MOSFET Drivers
PublicationA multi transformer flyback converter topology for supplying transistor drivers is presented. The topology presents some advantages over typical multi output single transformer, as reduction of effective leakage inductance, equal magnetic coupling between primary and secondary circuits and better isolation between outputs. Simulation study carried out in the LTSpice IV program and preliminary experimental results indicate high...
-
Distribution Transformer with Multi-Zone Voltage Regulation for Smart Grid System Application
PublicationThe article presents four concepts of the multi-zone voltage regulation (MZVR) system. It is a combination of a distribution transformer with an on-load tap-changer, for step voltage regulation, and a power electronic converter, dimensioned for a fraction of MZVR power, realizing continuous voltage regulation, supplemented by a special switch, the so-called bypass. This allows voltage regulation at high resolution, wide range and...
-
Adaptive estimation of the transformer stray capacitances for DC–DC converter modelling
PublicationNew low cost and accurate estimation method of transformer stray capacitances for wide band DC–DC converter modelling and design is proposed. The Wiener filter (WF) method is applied to estimate the transformer impedance – referred to the selected transformer winding configurations. Laboratory tests are used to adapt the filter, that is to find optimal impedance which minimises mean square error between measured, noise perturbed...
-
Management of MV/LV Transformer Replacement Based on AMI Platform
PublicationThe paper presents the extended possibilities of managing the selection and replacement of MV/LV transformers using the measurement data from the Advanced Metering Infrastructure (AMI) system. The analysis was conducted on samples of over 1900 transformers that operate in two different types of MV grids: rural and urban. The analysis has shown that there is a great potential in the field of optimizing the rated power of the transformers.
-
3-phase medium frequency transformer for a 100kW 1.2kV 20kHz Dual Active Bridge converter
PublicationThe article presents a three-phase Medium Frequency Transformer being a part of a 100kW 1.2kV 20kHz Dual Active Bridge DC-DC converter. The transformer design is detailed focusing on winding and core power loss calculation. The high power three-phase MFT prototype is presented. The experimental results include the transformer impedance characteristics, no load test and three-phase DAB full load test waveforms
-
Modified Preisach model of hysteresis in multi air gap ferrite core medium frequency transformer
PublicationThis article presents the modified Preisach model of hysteresis for a 3-phase medium frequency transformer in a 100 kW dual active bridge converter. The transformer magnetic core is assembled out of ferrite I-cores, which results in multiple parasitic air gaps. For this transformer, the hysteresis loops were measured and parameters of the Preisach model were determined. The Preisach distribution function is approximated with a...
-
Multi-transformer primary-side regulated flyback converter for supplying isolated IGBT and MOSFET drivers
PublicationThis paper presents primary-side voltage regulated multi-transformer quasi-resonant flyback converter (MTFC) for supplying isolated power switch drivers. The proposed topology offers distinct advantages over frequently used flyback converter possessing one high frequency transformer with isolated multiple outputs. Particularly, when a large number of separate dc supply units is required, then MTFC enables improved regular distribution...
-
Analysis of leakage flux in deenergized transformer
PublicationThe article presents the numerical analysis of the magnetic field that occurs around the transformer after it has been switched off. The purpose of this analysis was to determine if it is possible to define the residual fluxes in the legs of transformer based on the measurements of this field. These studies have allowed us to determine the quantity and location of the sensors. The influence of the Earth's magnetic field has also...
-
Hybrid stepless distribution transformer with four-quadrant AC/DC/AC converter at low voltage side - simulation tests
PublicationThe article presents the work of the stepless hybrid distribution transformer (HT), as an alternative to the so far applied Automatic Voltage Regulator (AVR) solutions, used to control the voltage in the power system in terms of the fundamental harmonic. The HT is a combination of a conventional distribution transformer and an AC/DC/AC converter connected in series with the transformers secondary winding. In the work the basic...
-
Lagrangian model of an isolated dc-dc converter with a 3-phase medium frequency transformer accounting magnetic cross saturation
PublicationThis article presents a nonlinear equivalent circuit model of an isolated dc-dc converter with a 3-phase medium frequency transformer. The model takes into account the magnetic cross saturation of the 3-phase core-type magnetic circuit. The model is suitable in detailed electromagnetic transient simulations of power systems involving isolated dc-dc converters. The model is developed using the Lagrange energy method. It involves...
-
Method of determining the residual fluxes in transformer core
PublicationThe article presents the method of calculating the residual induction in transformer columns. The method is based on measurement of the magnetic induction in selected points around the transformer core. The values of residual induction are calculated as linear combination of the results of measurement.
-
Research of leakage magnetic field in deenergized transformer
PublicationThe article deals with the issue of the numerical analysis of the magnetic field occurring around the transformer after it has been powered down. The main goal of this analysis was to examine if it is possible to identify the residual fluxes in the transformer legs based on this fields’ measurements. It was also intended to determine the type and the location of magnetic sensors. Numerical analysis of the magnetic field was performed....
-
Effective Permeability of Multi Air Gap Ferrite Core 3-Phase Medium Frequency Transformer in Isolated DC-DC Converters
PublicationThe magnetizing inductance of the medium frequency transformer (MFT) impacts the performance of the isolated dc-dc power converters. The ferrite material is considered for high power transformers but it requires an assembly of type “I” cores resulting in a multi air gap structure of the magnetic core. The authors claim that the multiple air gaps are randomly distributed and that the average air gap length is unpredictable at the...
-
Modelling and analysis of medium frequency transformers for power converters
PublicationThe evolutions in power systems and electric vehicles, related to the economic opportunities and the environmental issues, bring the need of high power galvanically isolated DC-DC converter. The medium frequency transformer (MFT) is one of its key components, enabled by the increasing switching frequency of modern power semiconductors like silicon carbide transistors or diodes. The increased operating frequency offers small...
-
Analysis of transformer inrush currents
PublicationW artykule przedstawiono model i wyniki obliczeń prądu i strumienia magnetycznego w układzie zawierającym transformator trójfazowy i wyłącznik. Opracowano obwodowy model łącznika z łukiem elektrycznym. Model łuku zbudowano w oparciu o jego statyczną i dynamiczną charakterystykę prądowo-napięciową. Przeprowadzone symulacje wykazały, że wartość maksymalna prądu włączania transformatora zależy zarówno od chwili włączenia napięcia...
-
Comparative analysis of three‐phase dual active bridge converter with different transformer topology and modern universal control for DC microgrids
PublicationThe presented work discusses issues related to the use of modern multiphase topologies of Dual Active Bridge (DAB)-type converters. Converters of this type are widely used in most DC microgrid applications. The introduction emphasizes a comparative analysis between single-phase and multi-phase DAB topologies within high-power DC microgrids, delving into their respective advantages, drawbacks, design procedures, and considerations...
-
Marek Adamowicz dr hab. inż.
PeopleStopień naukowy doktora uzyskał w 2008 r. na Wydziale Elektrotechniki i Automatyki Politechniki Gdańskiej. W latach 2005 – 2011 pracował na Akademii Morskiej w Gdyni. W 2010 r. jako laureat programu NCBR LIDER wybrał Wydział Elektrotechniki i Automatyki Politechniki Gdańskiej jako jednostkę realizującą swój projekt z zakresu szerokopasmowych przyrządów półprzewodnikowych i ich zastosowań w elektrowniach wiatrowych. Od 2011 roku...
-
Transformer-Capsule Model for Intent Detection
Publication -
Compact microstrip to coplanar standard transformer.
PublicationW pracy zaprezentowano transformator standardu umożliwiający bezodbiciowe połączenie linii mikropaskowej z linią koplanarną. Konstrukcja układu opiera się na założeniu zachowania jednakowej wartości impedancji w każdym przekroju poprzecznym struktury. Zaprojektowano i przebadano dwa rozwiązania z ze skokową i ciągłą zmianą szerokości linii. Do badań numerycznych wykorzystano symulator pełnofalowy Momentum. W symulacjach uwzględniono...
-
Code development of a DSP-FPGA based control platform for power electronics applications
PublicationThis paper focuses on the implementation of power electronics algorithms in control platforms based on DSP-FPGA. Today’s power electronics technology demands high power computation with high speed interfacing at the same time. The most popular configuration is a DSP for the former and a FPGA for the latter. The main goal of this work was to develop a generic control system for power electronics application, but it is explained...