displaying 1000 best results Help
Search results for: implantable assist device
-
Novel Design of an Ocean Wave Power Device
PublicationW artykule przedstawiono nowoczesną boję energetyczną o opatentowanej konstrukcji. Omówiono jej konstrukcję oraz przedstawiono problemy konstrukcyjne i badawcze. W ostatniej części artykułu przedstawiono wyniki badań wykonanych na modelu w basenie modelowym.
-
Reception of Terrestrial DAB+ and FM Radio with a Mobile Device: A Subjective Quality Evaluation
PublicationNowadays, terrestrial broadcasting enables to receive content anytime and everywhere. People can obtain information both with a portable or desktop receiver, which include pocket-sized devices as well as high-end Hi-Fi equipment, not to mention car audio systems. Numerous manufacturers include FM-compatible chipsets in a variety of user equipment (UE), including mobile phones. However, digital radio signal processing modules, such...
-
The New 3D Printed Left Atrial Appendage Closure with a Novel Holdfast Device: A Pre-Clinical Feasibility Animal Study
PublicationMany patients undergoing cardiac surgery have risk factors for both atrial fibrillation and stroke. The left atrial appendage (LAA) is the primary site for thrombi formation. Therefore LAA occlusion devices should be tested for their ability to reduce future cerebral ischemic events in patients with high-risk of haemorrhage. The aim of this study was to evaluate the safety and feasibility of a novel left atrial appendage exclusion...
-
Clinical effectiveness of primary prevention implantable cardioverter-defibrillators: results of the EU-CERT-ICD controlled multicentre cohort study
Publication -
Peripheral device for marking eye artifacts in the EEG examination
PublicationUrządzenie peryferyjne do oznaczania artefaktów ocznych w badaniu EEG (43) Zgłoszenie ogłoszono: 21.05.2018 BUP 11/18 (45) O udzieleniu patentu ogłoszono: 15.06.2020 WUP 07/20 (73) Uprawniony z patentu: ZACHODNIOPOMORSKI UNIWERSYTET TECHNOLOGICZNY W SZCZECINIE, Szczecin, PL (72) Twórca(y) wynalazku: JOANNA GÓRECKA, Stargard, PL ANDRZEJ BIEDKA, Wołczkowo, PL (74) Pełnomocnik: rzecz. pat. Renata Zawadzka PL 235263 B1
-
Analysis of the Electronic Device Exploitation Process – Research Results
Publication -
Miniaturization and Automation of an Internally Cooled Coated Fiber Device
Publication -
Using wearable device for biomedical signal acquisition and processing
PublicationIn this paper we present the research conducted on synchronous measurements of biosignals. The experiment was conducted to evaluate the possibility of estimating vital signs based on eye tracking. Method: The eGlasses platform was used for acquisition of ECG, respiration rate, eye and pupil movement and blood pressure. Data were acquired in three 5 min. intervals during which a subject was performing certain tasks. The signals...
-
Adaptive acoustic crosstalk cancellation in mobile computer device
PublicationThe cancellation of acoustic crosstalk is employed to enhance the stereo image in mobile listening conditions. A practical setup employing a mobile computer is employed. The adaptation of the crosstalk cancellation filter to the position of the listener's head is featured. The measurement evaluating the possibility of practical application of the method are described. The head and torso simulator was used for measurements. The...
-
Atlantic sturgeon Acipenser oxyrinchus and alien sturgeon species in Polish waters: can biometric analysis assist species discrimination and restoration?
Publication -
Embedded device for indoor positioning of mobile terminals in ISM 2.4 GHz frequency band integrated with ESPAR antenna
PublicationIn the era of multifunctional mobile phones, wireless positioning is one of the most important branches of telecommunications development. This functionality is possible thanks to global positioning systems such as GPS, whose services are available to every average user. Global systems, however, suffer from their low accuracy in confined environments such as forests and building interiors. A popular...
-
Determination of Ocular Artifacts in the Clinical EEG Software by a Peripheral Device
Publication -
A Method and Device for 3D Recognition of Cutting Edge Micro Geometry
Publication -
A Method of Lathe Checks Measurement; SMOF device and its software
Publication -
A Method and Device for 3D Recognition of Cutting Edge Micro Geometry
PublicationA very useful method was successfully applied in the investigation of tools for machining wood and wood based composites. It allows scanning of the cutting edge micro geometry in three dimensions and reproducing it in a virtual space as a 3D surface. The application of the method opens new possibilities of studying tool wear by scanning, including the calculation of volume loss and other analysis of tool wedge geometry along and...
-
A New Technique of Spine Disease Treatment Supported by ADRSK1 Device
Publication -
Synthesis and hydrogen evolving catalysis of a panchromatic photochemical molecular device
PublicationA dinuclear hydrogen evolution photocatalyst [(tbbpy)2Os(tpphz)PtI2](PF6)2 (tbbpy = 4,4′-tert-butyl-2,2′-bipyridine; tpphz = tetrapyrido[3,2-a:2′,3′-c:2′′,3′′-h:2′′′,3′′′-j]phenazine) is synthesized in order to make use of the broader range of visible light absorption mitigated by the osmium center. In a first step, the activity of the complex for hydrogen evolution is investigated by evaluating the role of different electron donors...
-
Rehabilitation device supporting active and passive upper limb exercises
PublicationThis article presents a mechatronic solution for rehabilitation devices supporting active and passive exercises in persons with motor dysfunctions of the upper limbs in the area of the elbow and shoulder joints. A planar positioner integrated with original software and a control system, served as the basis for creating the present solution. Bellman’s programming method was applied to optimize the motion trajectory of the planar...
-
A pilot study with flow mediated skin fluorescence: A novel device to assess microvascular endothelial function in coronary artery disease
PublicationBackground: Endothelial dysfunction is one of the earliest vascular manifestations in the pathogenesis of cardiovascular disease. Noninvasive, simple and inexpensive methods of endothelial function assessment are therefore needed. Methods: Microvascular endothelial function was assessed in coronary artery disease (CAD) patients by flow mediated skin fluorescence (FMSF), based on measurements of NADH fluorescence intensity during...
-
DESIGN OF THE DUAL CONSTELLATION GPS/GALILEO MOBILE DEVICE FOR IMPROVING NAVIGATION OF THE VISUALLY IMPAIRED IN AN URBAN AREA
PublicationIt is well known by users of Personal Navigation Device (PND) and other GPS-based devices that positioning suffers from (local) significant decreases of accuracy in partially obscured environments like urbanized areas, where buildings (especially high buildings), trees or terrain block large portions of the sky. In such areas, GPS receiver performance is usually deteriorated by the reduced number of currently available satellite...
-
Survey of patient and physician assessment of a compliance reminder device in the treatment of hypertension
Publication -
Mechanical chest compression with the LifeLine ARM device during simulated CPR
Publication -
Spectroscopic and microscopic study of Prussian blue film for electrochromic device application
Publication -
Operation of an ultra short fuse shunted by a semiconductor device: simulation and experiments.
PublicationW artykule przedstawiono ideę działania i wymagane cechy ultraszybkiego bezpiecznika w ograniczniku hybrydowym z równoległym elementem półprzewodnikowym. Eksperyment i modelowanie działanie bezpiecznika przeprowadzono dla spodziewanego prądu zwarciowego 2 kA. Symulacje wykonano przy użyciu programu polowego FLUX. Jego zastosowanie do modelowania ultrakrótkich bezpieczników zostało również przedstawione.
-
Auditory Brainstem Responses recorded employing Audio ABR device
Open Research DataThe dataset consists of ABR measurements employing click, burst and speech stimuli. Parameters of the particular stimuli were as follows:
-
ECG measurement from the hand with standing - hands resting on the device - Woman 27 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Man 29 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 49 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Man 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 30 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Man 53 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with standing - hands resting on the device - Woman 24 age
Open Research DataThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
Modular Ceramic-Polymeric Device for Analysis of Selected Elements in Liquid Using Microplasma
Publication -
Evaluation of Sound Enhancement in Mobile Device Using Virtual Bass Synthesiss Algorithm
PublicationAn experiment conducted to validate possibility of use virtual bass synthesis (VBS) algorithm in a portable computer is presented. The subjective listening tests based on the procedure of pairwise comparison between VBS, based on the so-called missing fundamental phenomenon, and standard bass boost technique are employed. The evaluation was carried out in two types of conditions: in a professional listening room and employing an...
-
Assessment of the Reliability of Wind Farm Device on the Basis of Modeling Its Operation Process
Publication -
Numerical Analysis of Magnetic Core Properties Influence on Residual Current Device Behaviour
PublicationW artykule przedstawiono analizę wpływu kształtu prądu w uzwojeniu pierwotnym transformatora prądowego na pracę przekładnika różnicowo-prądowego. Przeprowadzono obliczenia symulacyjne dla wymuszenia o kształcie sinusoidy i sinusoidy wyprostowanej dla częstotliwości 50 Hz. Wzięto pod uwagę dwa typy charakterystyki magnesowania transformatora: dla materiału magnetycznie miękkiego i materiału o prostokątnej pętli histerezy. Analiza...
-
Pointing device for elders with low cost and mixed manual-gaze control interface
PublicationW artykule przedstawiono projekt interfejsu pozwalającego na zastąpienie standardowej myszki komputerowej sterowaniem wzrokowym, z nieznacznym manualnym wspomaganiem. Manualne wspomaganie ma na celu korekcję współrzędnych kursora.
-
The Application of a Mobile Unmanned Device for Monitoring Water and Sediment Pollution in the Port of Gdynia
PublicationPollution in the Port of Gdynia can encompass various types of substances and contaminants that affect the quality of water and sediment in this region. Ships entering and leaving the port can release pollutants such as oil, fuel, waste, and chemicals into the water. Controlling and monitoring these pollutants is a crucial part of environmental stewardship. In recent years, uncrewed units have been increasingly in use for in situ...
-
Effect of Sieve Unit Inclination Angle in a Rotary Cleaning Device for Barley Grain
Publication -
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 28 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 24 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 53 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 30 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
Sensitivity of personalized ventilation air terminal device geometry with regard to a human thermal sensation
Publication -
Optimal selection of the sawdust separation device for a narrow-kerf sawing machine PRW15-M
PublicationW pracy przedstawiono granulometryczną analizę rozkładu wiórów i pyłu drzewnego otrzymanego w procesie przecinania suchych pryzm sosnowych na pilarce ramowej wielopiłowej PRW15-M. Wielkości wiórów mieściły się w granicach od 84,7 μm do nawet 14 mm. Te ostatnie są elementami będącymi efektem rozszczepiania dolnej powierzchni pryzmy przez wychodzące z niej ostrza piły. Większośc wiórów z najmniejszych frakcji ma postać sześciennych...
-
Numerically efficient algorithm for compact microwave device optimization with flexible sensitivity updating scheme
PublicationAn efficient trust-region algorithm with flexible sensitivity updating management scheme for electromagnetic (EM)-driven design optimization of compact microwave components is proposed. During the optimization process, updating of selected columns of the circuit response Jacobian is performed using a rank-one Broyden formula (BF) replacing finite differentiation (FD). The FD update is omitted for directions sufficiently well aligned...
-
A Generalized SDP Multi-Objective Optimization Method for EM-Based Microwave Device Design
PublicationIn this article, a generalized sequential domain patching (GSDP) method for efficient multi-objective optimization based on electromagnetics (EM) simulation is proposed. The GSDP method allowing fast searching for Pareto fronts for two and three objectives is elaborated in detail in this paper. The GSDP method is compared with the NSGA-II method using multi-objective problems in the DTLZ series, and the results show the GSDP method...