Filters
total: 199
Search results for: pulse-frequency
-
Selective Harmonic Elimination PWM For a Cascaded Multi-level Inverter
PublicationThis paper deals with the selective harmonic elimination pulse width modulation (SHE-PWM) technique. This technique is used for the elimination of selected dominant low order harmonics in the multi-level inverter output voltage. The presence of these harmonics is the essential drawback of such kind of inverters; especially when it is used for the control of different AC drivers. The SHE-PWM is based...
-
Pulse-Width Modulation of Power Electronic DC–AC Converter
PublicationThe Second Edition of High Performance Control of AC Drives with Matlab®/Simulink delivers an updated and thorough overview of topics central to the understanding of AC motor drive systems. The book includes new material on medium voltage drives, covering state-of-the-art technologies and challenges in the industrial drive system, as well as their components, and control, current source inverter-based drives, PWM techniques for...
-
Heart rate PPG signals with acceleration captured at wrist during small and moderate body movements
Open Research DataHeart rate PPG signals with acceleration captured at wrist during small and moderate body movements
-
Structure and the space vector modulation for a medium-voltage power-electronic-transformer based on two seven-level cascade H-bridge inverters
PublicationThis study presents the structure and the space vector pulse-width modulation (SVPWM) for power electronic transformer (PET) based on two seven-level cascade H-bridge (CHB) inverters. The DC links of CHB inverters are coupled with nine dual-active bridge (DAB) converters with medium-frequency transformers. The DC-link voltages are equalised with two methods – through the control of DAB voltages...
-
A Five-Leg Three-Level Dual-Output Inverter
PublicationClassical 3-level dual-output inverter, 3-L DOI, involves two similar 3-level inverters that provides a pair of 3-phase output voltages with same or different frequencies from common input voltage source. Flexibility of either operation of the constituting inverters is evident in this DOI; but total duplication of power switches is a major drawback. State of the art coupled 3-L DOIs reduce this drawback by providing series-shared...
-
Mechanical Properties and Residual Stress Measurements of Grade IV Titanium and Ti-6Al-4V and Ti-13Nb-13Zr Titanium Alloys after Laser Treatment
PublicationNowadays, surface engineering focuses on research into materials for medical applications. Titanium and its alloys are prominent, especially Ti-6Al-4V and Ti-13Nb-13Zr. Samples made of pure grade IV titanium and the titanium alloys Ti-6Al-4V and Ti-13Nb-13Zr were modified via laser treatment with laser beam frequency f = 25 Hz and laser beam power P = 1000 W during a laser pulse with duration t = 1 ms. Subsequently, to analyze...
-
Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset
PublicationThe dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.
-
High Signal Resolution Pulse Oximetry as a Prognostic Indicator of Radiotherapy Toxicity: A Pilot Study
PublicationIntroduction: Radiotherapy plays a prominent role in the multidisciplinary treatment of cancers. Despite new irradiation techniques, radiation-induced cardiotoxicity remains a leading cause of morbidity and mortality. Therefore, prognostic indicators of radiotherapy toxicity are essential. This study aimed to investigate the influence of applied radiotherapy on the pulse wave recording and thereby on...
-
Reliability of Pulse Measurements in Videoplethysmography
PublicationReliable, remote pulse rate measurement is potentially very important for medical diagnostics and screening. In this paper the Videoplethysmography was analyzed especially to verify the possible use of signals obtained for the YUV color model in order to estimate the pulse rate, to examine what is the best pulse estimation method for short video sequences and finally, to analyze how potential PPG-signals can be distinguished from...
-
Increased inspiratory resistance affects the dynamic relationship between blood pressure changes and subarachnoid space width oscillations
PublicationBackground and objective Respiration is known to affect cerebrospinal fluid (CSF) movement. We hypothesised that increased inspiratory resistance would affect the dynamic relationship between blood pressure (BP) changes and subarachnoid space width (SAS) oscillations. Methods Experiments were performed in a group of 20 healthy volunteers undergoing controlled intermittent Mueller Manoeuvres (the key characteristic of the procedure...
-
High Performance Control of AC Drives with Matlab/ Simulink
PublicationExplore this indispensable update to a popular graduate text on electric drive techniques and the latest converters used in industry. The Second Edition of High Performance Control of AC Drives with Matlab®/Simulink delivers an updated and thorough overview of topics central to the understanding of AC motor drive systems. The book includes new material on medium voltage drives, covering state-of-the-art technologies and challenges...
-
Analysis of the Accuracy of Pulse Estimation Using Smart Watches
PublicationThe purpose of this paper is to perform an analysis of the accuracy of the pulse estimation by comparing readings from a smartwatch with readings from medical devices. The study required writing applications that allow continuous pulse measurement. As a result, two applications were created for the smartwatch. The first one is dedicated to Android Wear devices, while the other one is compatible with Tizen watches. The next step...
-
Directed electromagnetic pulse dynamics: projecting operators method
PublicationIn this article, we consider a one-dimensional model of electromagnetic pulse propagation in isotropic media, takinginto account a nonlinearity of the third order. We introduce a method for Maxwell's equation transformation on thebasis of a complete set of projecting operators. The operators correspond to wave dispersion branches including thedirection of propagation. As the simplest result of applying the method, we derive a system...
-
Measuring pulse rate with a webcam — A non-contact method for evaluating cardiac activity
PublicationIn this paper the simple and robust method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face image captured from webcam. The desired signal was obtained by proper channel selection and principal component analysis. A developed non-contact method of heart rate monitoring is shown in the paper. The proposed technique may have a great value in monitoring...
-
Time domain model of the resonance-based electromagnetic pulses emission system
PublicationIn the literature, the emission properties of the electromagnetic field pulse systems based on high voltage antennas (HVR) have been widely described. In order to increase the emission efficiency by extending duration and increasing amplitude of the impulse it is possible to use a resonance system tuned to the parameters of the signal shaped in the pulse forming circuit. The synthesis of a time-domain simulation model of a complex...
-
The Influence of Laser Alloying of Ti13Nb13Zr on Surface Topography and Properties
PublicationThe laser alloying is a continually developing surface treatment because of its significant and specific structuration of a surface. In particular, it is applied for Ti alloys, being now the most essential biomaterials` group for load-bearing implants. The present research was performed on the Ti13Nb13Zr alloy subject to laser modification in order to determine the treatment effects on surface topography and its some mechanical...
-
Blood Pressure Estimation Based on Blood Flow, ECG and Respiratory Signals Using Recurrent Neural Networks
PublicationThe estimation of systolic and diastolic blood pressure using artificial neural network is considered in the paper. The blood pressure values are estimated using pulse arrival time, and additionally RR intervals of ECG signal together with respiration signal. A single layer recurrent neural network with hyperbolic tangent activation function was used. The average blood pressure estimation error for the data obtained from 21 subjects...
-
Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter
PublicationThe paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...
-
A robust 18-pulse diode rectifier with coupled reactors
PublicationThe article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network...
-
Estimating Intercept Range of Silent Sonar
PublicationWhen used in military application, sonars should ensure secretiveness. There is some evidence suggesting that silent sonars have a significant advantage over pulse sonars in the respect. If improved, the secretiveness of silent sonar translates into the distance over witch its soundings signal are detected by intercept sonars. The article gives estimated distances for far, medium, and short range sonars operating in the oceans...
-
Can we rely on the pulse transit time - pressure relationship - models comparison
PublicationAn unobtrusive, noninvasive and continuous pressure measurement is invaluable however, still being under research and development. There are many attempts proposing an appropriate relationship between pulse pressure velocity and pressure. Fifteen different formulas, both theoretical and experimental, describing relation between blood pressure and crosssectional area of the vessel were examined. Using these formulas the relation...
-
Measuring Pulse Rate with a Webcam
PublicationIn this paper a simple method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face images captured from a webcam. The desired signal is obtained by proper channel selection and principal component analysis. To determine the accuracy of the method an ECG signal is collected together with a video recordings. The effectiveness of the algorithm is considered...
-
Remote Estimation of Video-Based Vital Signs in Emotion Invocation Studies
PublicationAbstract— The goal of this study is to examine the influence of various imitated and video invoked emotions on the vital signs (respiratory and pulse rates). We also perform an analysis of the possibility to extract signals from sequences acquired with cost-effective cameras. The preliminary results show that the respiratory rate allows for better separation of some emotions than the pulse rate, yet this relation highly depends...
-
Directed pulse dynamics
PublicationIntroducing a projection method into a one-dimensional model of a pulse propagation in isotropic media, we derive and investigate a system of equation describing dynamics ultrashort pulses of opposite directions ofpropagation and ones with interaction of directed pulses with different polarization.
-
Propagation of acoustic pulses in some fluids with yield stress
PublicationThis study is devoted to the derivation of approximate equations governing acoustic pulses in flows with yieldstress, including some time-dependent flows with a slow dependence on time of yield stress and apparent viscosity. Themodeling of yield stress and apparent viscosity in the vicinity of a zero deformation rate allows us to consider a thixotropicfluid as a Bingham plastic with coefficients that are dependent on time. The...
-
Influence of pulse waves on the transmission of near-infrared radiation in outer-head tissue layers.
PublicationIn this study, we investigate the effect of pulse waves on the transmission of near-infrared radiation in the outer tissue layers of the human head. This effect is important in using optical radiation to monitor brain conditions based on measuring the transmission changes in the near-infrared radiation between the source and the detector, placed on the surface of the scalp. This is because the signal related to the changes in the...
-
Ultrashort Opposite Directed Pulses Dynamics with Kerr Effect and Polarization Account
PublicationWe present the application of projection operator methods to solving the problem of the propagation and interaction of short optical pulses of different polarizations and directions in a nonlinear dispersive medium. We restrict ourselves by the caseof one-dimensional theory, taking into account material dispersion and Kerr nonlinearity. The construction of operators is delivered in two variants: for the Cauchy problem and for the...
-
New Architecture of Solid-State High-Voltage Pulse Generators
PublicationThe application of the nanosecond pulsed electric field (nsPEF) for biomedical treatments has gained more interest in recent decades due to the development of pulsed power technologies which provides the ability to control the electric field dose applied during tests. In this context, the proposed paper describes a new architecture of solid-state high-voltage pulse generators (SSHVPG) designed to generate fully customised sequences...
-
A Wind Energy Conversion System Based on a Generator with Modulated Magnetic Flux
PublicationIn this work, the concept of an energy conversion system for wind turbines based on the modified permanent magnet synchronous generator (PMSG) is presented. In the generator, a pair of three-phase windings is used, one of which is connected in a “star” and the second in a “delta” configuration. At the outputs of both windings, two six-pulse uncontrolled (diode) rectifiers are included. These rectifiers are mutually coupled by a...
-
Control strategy for the multilevel cascaded H-bridge converter
PublicationThe paper presents the control strategy for Cascaded H-bridge (CHB) converter . The converter output voltage using Space-Vector Pulse Width Modulation (SV-PWM) strategy is controlled. The DC-link voltages are controlled by appropriate choice of H-Bridges and appropriate choice of active and passive vectors.
-
A new duty cycles calculation method in pulse width modulation for direct matrix converters based on the shape function concept
PublicationPaper presents a new approach to duty cycle calculation in pulse width modulation for direct matrix converters. The essence of the proposed method is the use of elementary shape function of finite element. The algorithm for calculating the duty cycles was reduced to simple operations on the coordinates of input and output voltage vectors without trigonometric functions.
-
Enhanced Remote Control Providing Medical Functionalities
PublicationThis paper presents the enhanced remote control and its role in pervasive healthcare in the home. The device was equipped with health-related measurement modules and a message-processing unit. Preliminary results are presented for monitoring of a pulse, hand tremors, grip forces, and for self evaluation procedures. The interaction of the device with the smart environment is presented and discussed.
-
Pulse-Width Modulation Template for Five-Level Switch-Clamped H-Bridge-Based Cascaded Multilevel Inverter
PublicationThis article presents a carrier-based pulse-width modulation (PWM) template for a 5-level, H bridge-based cascaded multilevel inverter (MLI). The developed control concept generates adequate modulation template for this inverter topology wherein a sinusoidal modulating waveform is modified to fit in a single triangular carrier signal range. With this modulation approach, classical multiplicity and synchronization of the triangular...
-
Electrodeposited Biocoatings, Their Properties and Fabrication Technologies: A Review
PublicationCoatings deposited under an electric field are applied for the surface modification of biomaterials. This review is aimed to characterize the state-of-art in this area with an emphasis on the advantages and disadvantages of used methods, process determinants, and properties of coatings. Over 170 articles, published mainly during the last ten years, were chosen, and reviewed as the most representative. The most recent developments...
-
Studying the Effect of Working Conditions on WEDM Machining Performance of Super Alloy Inconel 617
PublicationWire electrical discharge machining (WEDM) has been for many years a precise and efficient non-conventional manufacturing solution in various industrial applications, mostly involving the use of hard-to machine materials like, among other, the Inconel super alloys. The focus of the present study is on exploring the effect of selected control parameters, including pulse duration, pulse-off time and the dielectric flow pressure on...
-
The data exchange between smart glasses and healthcare information systems using the HL7 FHIR standard
PublicationIn this study we evaluated system architecture for the use of smart glasses as a viewer of information, as a source of medical data (vital sign measurements: temperature, pulse rate, and respiration rate), and as a filter of healthcare information. All activities were based on patient/device identification procedures using graphical markers or features based on visual appearance. The architecture and particular use cases were implemented...
-
Current harmonic controller in multiple reference frames for series active power filter integrated with 18-pulse diode rectifier
PublicationThe paper presents the control system and selected results of experimental tests of the AC/DC power converter consisting of an 18-pulse diode rectifier based on coupled reactors and a serial active power filter. Proportional integral controllers with decoupling components are implemented in multiple reference frames for selective line current harmonic suppression. The regulator is provided with a backtracking anti-windup mechanism...
-
Radar time budget optimization subject to angle accuracy constraint via cognitive approach
PublicationThe problem of minimizing dwell time in multifunction phased array radar is considered. Target of interest is assumed to fluctuate according to a generalization of Swerling family and the parameters of fluctuation model are assumed to be known. The a'priori position of the target is uncertain. Optimization, whose variables include pulse count and array transmit beampattern, is carried out subject to achieving a desired accuracy...
-
Gate Driver with Overcurrent Protection Circuit for GaN Transistors
PublicationThe improvement of the gate driver for GaN transistor is presented in this paper. The proposed topology contains the overcurrent protectionwith the two-stage turning off and independent control of turn on and off time of the GaN transistor. The operation of driver and its application in thehalf-bridge converter are described using both simulation and prototype measurements. The overcurrent protection was tested in Double Pulse...
-
Eksperymentalna analiza modalna stojanów silników indukcyjnych
PublicationW artykule zaprezentowano technikę pomiarów i wyniki obliczeń postaci drgań własnych badanego stojana silnika indukcyjnego klatkowego. Przedstawiono również teoretyczne podstawy zastosowanej techniki obliczeniowej. Jako narzędzie akwizycji danych wykorzystano pomiarowy system PULSE firmy Brüel&Kjær, a w celu przeprowadzenia koniecznych obliczeń oraz wizualizacji wyników wykorzystano środowisko Matlab.
-
A compact smart sensor based on a neural classifier for objects modeled by Beaunier's model
PublicationA new solution of a smart microcontroller sensor based on a simple direct sensor-microcontroller interface for technical objects modeled by two-terminal networks and by the Beaunier’s model of anticorrosion coating is proposed. The tested object is stimulated by a square pulse and its time voltage response is sampled four times by the internal ADC of microcontroller. A neural classifier based on measurement data classifies the...
-
A method of self-testing of an analog circuit terminated by an ADC in electronic embedded systems controlled by microcontrollers
PublicationA new self-testing method of analog parts terminated by an ADC in electronic embedded systems controlled by microcontrollers is presented. It is based on a new fault diagnosis method based on on-line (i.e. during measurement), transformations of voltage samples of the time response of a tested part to a square pulse - onto localization curves placed in the measurement space. The method can be used for fault detection and single...
-
Analysis of the possibility of creep damage detection in T24 heat resistant steel with the help of magnetic nondestestructive testing methods
PublicationThe paper presents the result of an analysis of applicability of various electromagnetic methods of nondestructive evaluation for creep damage detection in a novel heat resistant steel - T24 grade. Two sample sets, cut out from membrane wall tubes, were investigated – the as-delivered one and another exploited for 36,000 h in a power plant. There are described results of magnetic hysteresis loops B(H), Barkhausen noise (BN) and...
-
Compact and Integrated High-Power Pulse Generation and Forming System
PublicationThis paper presents comprehensive analytical, numerical and experimental research of the compact and integrated high-power pulse generation and forming system based on the flux compression generator and the electro-explosive forming fuse. The paper includes the analysis of the presented solution, starting from the individual components studies, i.e., the separate flux compression generator tests in field conditions and the forming...
-
Long Distance Vital Signs Monitoring with Person Identification for Smart Home Solutions
PublicationAbstract— Imaging photoplethysmography has already been proved to be successful in short distance (below 1m). However, most of the real-life use cases of measuring vital signs require the system to work at longer distances, to be both more reliable and convenient for the user. The possible scenarios that system designers must have in mind include monitoring of the vital signs of residents in nursing homes, disabled people, who...
-
Comparison of the paracetamol electrochemical determination using boron-doped diamond electrode and boron-doped carbon nanowalls
PublicationTwo different type of electrodes, boron-doped diamond electrode (BDD) and boron-doped carbon nanowalls (B:CNW) electrode, were used for the electrochemical determination of paracetamol using the cyclic voltammetry and the differential pulse voltammetry in phosphate buffered saline, pH = 7.0. The main advantage of these electrodes is their utilization without any additional modification of the electrode surface. The peak current...
-
FFT spectrum based matching algorithm for activedynamic thermography
PublicationIn Active Dynamic thermography (ADT) sequences of consecutive temperature distributions are analyzed. In biomedical applications of ADT, the problems of a patient's movements in front of a thermal camera should be eliminated before data analysis. Complete mechanical stabilization of the patients is impossible due to natural voluntary and involuntary moves caused by pulse breathing, etc. This paper presents a simple and efficient...
-
Application of the laser diode with central wavelength 975 nm for the therapy of neurofibroma and hemangiomas
PublicationThis paper presents newly developed dermatological laser (with central wavelength 975 nm) for application in therapies requiring deep penetration of tissue, e.g. cutaneous (dermal) neurofibroma (Recklinghausen disease) and hemangiomas. This laser can work either in pulse or continues wave mode. Laser radiation is transmitted toward the application region by optical fiber with a diameter of 0.6 mm. The compact design of the laser...
-
Blood Pressure - Pulse Transit Time Relationships: Comparative Studies
PublicationA non-invasive and continuous blood pressure estimation could allow a better diagnosis and an earlier detection of various diseases. It could be performed using a photoplethysmography. However, it requires that a relation between blood pressure and pulse transit time is known. Eleven theoretical formulas were used in obtaining the simulated and noise free synthetic data. Then, they were utilized in validation of three, commonly...
-
DC-link voltage balancing in cascaded H-Bridge converters
PublicationIn the paper a DC-link voltage balancing strategy for multilevel Cascaded H-Bridge (CHB) converter is proposed. Presented solution bases on optimal choice of active vector durations in Space-Vector Pulse Width Modulation (SV-PWM). It makes it possible to DC-link voltages control and to properly generate the output voltage vector in the case of DC-link voltage unbalance. Results of simulation and experimental researches...