Filters
total: 285
filtered: 198
Chosen catalog filters
Search results for: pulse-frequency
-
A simulation investigation into the signal reconstruction accuracy of the transducer with pulse frequency output
Publication -
The use of a static electrical energy meter as a transducer of active power to a pulse frequency signal
Publication -
Software-based method of increasing the effective resolution of a measurement chain for a transducer with a pulse frequency output
Publication -
Digital Processing of Frequency–Pulse Signal in Measurement System
PublicationThe work presents the issue of the use of multichannel measurement systems of sensors processing input value to impulse signal frequency. The frequency impulse signal obtained from such sensors is often required to be processed at the same time with a voltage signal which is obtained from other sensors used in the same measurement system. In such case, it is usually necessary to sample the output signals from all sensors in the...
-
Frequency measurement research with weight averaging of pulse output signal of voltage-to-frequency converter
PublicationThe paper presents the essence and investigation of the efficiency of weight averaging of a pulse output signal of voltage-to-frequency converter. The effect of counting and the influence of interference on the result of weight averaging of frequency modulated pulses are analyzed. It is shown that from the point of view of counting error reduction, the best are polynomial weight functions. In the case of high interferences whose...
-
Digital processing of pulse signal from light-to-frequency converter under dynamic condition
Publication -
Pulse-Modulated Radio-Frequency Alternating-Current-Driven Atmospheric-Pressure Glow Discharge for Continuous-Flow Synthesis of Silver Nanoparticles and Evaluation of Their Cytotoxicity toward Human Melanoma Cells
Publication -
Influence of preprocessing techniques on pulse pressure velocity determination
PublicationPulse Wave Velocity (PWV) is measured and utilized in many clinical applications. Recently, a wide research has been led to develop a cuff-less and continuous blood pressure method basing on PWV. However, in this application a decision on choosing an appropriate fiducial point of pulse wave (PW) waveform is necessary and substantial. It would allow to measure time parameters necessary to determine PWV. An influence of sampling...
-
The accuracy of pulse rate estimation from the sequence of face images
PublicationThe goal of this paper is to analyze the accuracy of pulse rate estimation from the sequence of face images. Simulated and real signals were used to evaluate two pulse rate estimators; one for frequency domain and the second one for time domain using the autocorrelation function. The results show that the mean difference between the reference measurements and estimated pulse rate values are about 2bpm. In the analysis of short...
-
Multi-pulse VSC arrangements with coupled reactors
PublicationThis paper presents a novel approach to the multipulse VSC (Voltage Source Converter) arrangements based on several conventional inverter modules connected in parallel by using coupled reactors. This solution reduces the THD of the output voltage, despite the low switching frequency of transistors. The advantage of the proposed solution is also a relatively small rated power of the reactors. Proposed new arrangements for different...
-
Utilizing pulse dynamics for non-invasive Raman spectroscopy of blood analytes
PublicationNon-invasive measurement methods offer great benefits in the field of medical diagnostics with molecular-specific techniques such as Raman spectroscopy which is increasingly being used for quantitative measurements of tissue biochemistry in vivo. However, some important challenges still remain for label-free optical spectroscopy to be incorporated into the clinical laboratory for routine testing. In particular, non-analyte-specific...
-
SiC-based T-type modules for multi-pulse inverter with coupled inductors
PublicationThe paper presents SiC-based three-level T-type modules designed for a high-performance 30kVA DC/AC inverter operating at high frequency 85 kHz with low THD of the output voltage. This inverter system consists of two integrated parts. The first part is active and contains three parallelconnected three-phase T-type modules built with fast-switching SiC power transistors. The second, passive part of the system is a set of inductors...
-
Evaluation of Facial Pulse Signals Using Deep Neural Net Models
PublicationThe reliable measurement of the pulse rate using remote photoplethysmography (PPG) is very important for many medical applications. In this paper we present how deep neural networks (DNNs) models can be used in the problem of PPG signal classification and pulse rate estimation. In particular, we show that the DNN-based classification results correspond to parameters describing the PPG signals (e.g. peak energy in the frequency...
-
High Frequency Harmonics Emission in Smart Grids
PublicationPulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....
-
Low Frequency Conducted Emissions of Grid Connected Static Converters
PublicationPulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....
-
Methods of measurement signal acquisition from the rotational flow meter for frequency analysis
PublicationOne of the simplest and commonly used instruments for measuring the flow of homogeneous substances is the rotational flow meter. The main part of such a device is a rotor (vane or screw) rotating at a speed which is the function of the fluid or gas flow rate. A pulse signal with a frequency proportional to the speed of the rotor is obtained at the sensor output. For measurements in dynamic conditions, a variable interval between...
-
A concept of software extension of 3D low-PRF radar systems to 4D semi-medium-PRF radar systems
PublicationWe present a concept of software modification of three-dimensional (3D) radar systems, designed to work in the low pulse repetition frequency mode, that equips them with the ability to estimate the radial velocity and to properly measure the range of targets that are detected outside the radar’s instrumented range. Despite the fact that the proposed modifications are designed so as to require only minor changes in software, they...
-
Modular multipulse voltage source inverters with integrating coupled reactors
PublicationA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse and twenty-four-pulse...
-
The forming and emission of high power electromagnetic pulses
PublicationAn impulse energy source, a power conditioning system and an electromagnetic field emitter are essential to generate an electromagnetic field pulse (EMFP) with a specific frequency bandwidth. Selected simulation results for a power conditioning system consisting of a fuse opening switch and a paraboloidal electromagnetic emitter have been presented in this article. The synthetic system examined in the simulation is powered by an...
-
Hybrid Modulation for Modular Voltage Source Inverters with Coupled Reactors
PublicationThis paper proposes and discusses a concept of a hybrid modulation for the control of modular voltage source inverters with coupled reactors. The use of coupled reactors as the integrating elements leads to significant reduction in the size and weight of the circuit. The proposed modulation combines novel coarsely quantized pulse amplitude modulation (CQ-PAM) and innovative space-vector pulse width modulation (SVPWM). The former...
-
The forming and emission of high power electromagnetic pulses
PublicationAn impulse energy source, a power conditioning system and an electromagnetic field emitter are essential to generate an electromagnetic field pulse (EMFP) with a specific frequency bandwidth. Selected simulation results for a power conditioning system consisting of a fuse opening switch and a paraboloidal electromagnetic emitter have been presented in this article. The synthetic system examined in the simulation is powered by...
-
Continuous blood pressure monitoring by photoplethysmography - signal preprocessing requirements based on blood flow modelling
PublicationObjective. The aim of the study is to investigate the effect of the signal sampling frequency and low-pass filtering on the accuracy of the localisation of the fiducial points of the photoplethysmographic signal (PPG), and thus on the estimation of the blood pressure (i.e. the accuracy of the estimation). Approach. Statistical analysis was performed on 3,799 data samples taken from a publicly available database. Four PPGfiducial...
-
Narrowband Transmission Quality in Presence of Modified IEEE 802.15.4a UWB Signal
PublicationThis paper presents results of measurement of narrowband transmission quality in presence of impulse radio UWB interference. In the first part of paper, unmodified IEEE 802.15.4a IR UWB signal is used. Then some modification of transmitted pulse sequence is proposed, which allow to reduce UWB power spectral density at frequency of narrowbandtransmission. Finally narrowband transmission quality in presence of modified ultrawideband...
-
Stress Detection of Children With ASD Using Physiological Signals
PublicationThis paper proposes a physiological signal-based stress detection approach for children with autism spectrum disorder (ASD) to be used in social and assistive robot inter- vention. Electrodermal activity (EDA) and blood volume pulse (BVP) signals are collected with an E4 smart wristband from children with ASD in different countries. The peak count and signal amplitude features are derived from EDA signal and used in order to detect...
-
Narrowband Transmission Quality in Presence of Modified IEEE 802.15.4a UWB Signal
PublicationThis paper presents results of measurement of narrowband transmission quality in presence of impulse radio UWB interference. In the first part of paper, unmodified IEEE 802.15.4a IR UWB signal is used. Then some modification of transmitted pulse sequence is proposed, which allow to reduce UWB power spectral density at frequency of narrowband transmission. Finally narrowband transmission quality in presence of modified ultrawideband...
-
The Conceptual Research over Low-Switching Modulation Strategy for Matrix Converters with the Coupled Reactors
PublicationIn this paper, different Pulse Width Modulation (PWM) strategies for operating with a low-switching frequency, a topology that combines Conventional Matrix Converters (CMCs), and Coupled Reactors (CRs) are presented and discussed. The principles of the proposed strategies are first discussed by a conceptual analysis and later validated by simulation. The paper shows how the combination of CMCs and CRs could be of special interest...
-
Modeling of Common Mode Currents Induced by Motor Cable in Converter Fed AC Motor Drives
PublicationInvestigation of conducted EMI generation in AC motor fed by pulse width modulated frequency converters requires to consider parasitic capacitances in converters, motor windings and feeding cables to be taken into account. Motor voltage transients and related common mode currents are significantly correlated with resonance effects occurring in load circuits. An analysis of frequency converter load impedance-frequency characteristics...
-
Multipulse inverter structures with low voltage distortion
PublicationA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse three-level...
-
Low harmonic multipulse voltage converters using coupled reactors
PublicationThis paper presents a novel approach to the multi pulse voltage converters (VC), especially voltage source inverters (VSI) and matrix converters (MC) based on several typical identical modules connected in parallel using coupled reactors. Such arrangements resulting in lower voltage distortions at extremely low switching frequency. The proposed arrangement was validated by simulation. Laboratory models of 18- and 24pulse 3-level...
-
Cichy sonar - stan aktualny i perspektywy
PublicationW zastosowaniach militarnych często istnieje potrzeba prowadzenia obserwacji w sposób skryty za pomocą urządzeń emitujących sygnały trudne do przechwycenia przez przeciwnika. Rozwiązania stosowane w cichych radarach stanowiły punkt wyjścia do opracowania cichego sonaru. Prace nad projektem rozpoczęto na Politechnice Gdańskiej w roku 2010 w ramach Grantu NCBiR i są one dalej kontynuowane. W celu zachowania w cichym sonarze warunków...
-
Derivation of motor mean phase currents in PMSM drives operating with low switching-to-fundamental frequency ratio
PublicationPulse width modulation (PWM) of inverter output voltage causes the waveforms of motor phase cur-rents to consist of distinctive ripples. In order to provide suitable feedback for the motor current con-trollers, the mean value must be extracted from the currents’ waveforms in every PWM cycle. A com-mon solution to derive the mean phase currents is to sample their value at the midpoint of a symmetrical PWM cycle. Using an assumption...
-
Motor Cable Influence on the Conducted EMI Emission of the Converter Fed AC Motor Drive. - Vol. 1
PublicationInvestigation of conducted electromagnetic interference in AC motor drives fed by pulse width modulated voltage converters requires considering parasitic capacitances in converters, motor windings and feeding cables to be taken into account. Motor voltage transients and related conducted electromagnetic emission are significantly correlated with resonance effects occurring in load circuits. The levels of intensity of these phenomena...
-
Femtosecond Er-doped fiber laser source tunable from 872 to 1075 nm for two-photon vision studies in humans
PublicationWe report the development of a widely-tunable femtosecond fiber laser system and its application for two-photon vision studies. The source is based on an Er-doped fiber laser with spectral shift up to 2150 nm, followed by a second harmonic generation module to generate a frequency-doubled beam tunable from 872 to 1075 nm. The source delivers sub-230 fs pulses with nearly-constant duration over the entire tuning range, with output...
-
Detection of damages in a rivetted plate
PublicationThe paper presents the results of damage detection in a riveted aluminium plate. The detection method has been based on Lamb wave propagation. The plate has been analysed numerically and experimentally. Numerical calculations have been carried out by the use of the time-domain spectral finite element method, while for the experimental analysis laser scanning Doppler vibrometry (LSDV) has been utilised. The panel has been excited...
-
Behavior of residual current devices at frequencies up to 50 kHz
PublicationThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
Cross-talk Between the Heart and Arteries in Older 65+ Adults
PublicationRegulatory synchronization between the heart and the arterial walls is essential for optimal blood delivery to tissues. We investigated functional coherence between heart rhythm and aortic wall compliance in 30 volunteers aged 65 – 74. ECG and carotid and iliac pulse-wave were recorded and digitized at 2 kHz. Carotid-femoral pulse-wave transit time (cfTT) which reflex aortic compliance was assessed using the intersecting tangent...
-
Optimization-based stacked machine-learning method for seismic probability and risk assessment of reinforced concrete shear walls
PublicationEfficient seismic risk assessment aids decision-makers in formulating citywide risk mitigation plans, providing insights into building performance and retrofitting costs. The complexity of modeling, analysis, and post-processing of the results makes it hard to fast-track the seismic probabilities, and there is a need to optimize the computational time. This research addresses seismic probability and risk assessment of reinforced...
-
Stress Detection of Children with Autism using Physiological Signals in Kaspar Robot-Based Intervention Studies
PublicationThis study aims to develop a stress detection system using the blood volume pulse (BVP) signals of children with Autism Spectrum Disorder (ASD) during robot-based interven- tion. This study presents the heart rate variability (HRV) analysis method to detect the stress, where HRV features are extracted from raw BVP signals recorded from an E4 wristband during interaction studies with the social robot Kaspar. Low frequency power...
-
Asynchronous Charge Carrier Injection in Perovskite Light-Emitting Transistors
PublicationUnbalanced mobility and injection of charge carriers in metal-halide perovskite light-emitting devices pose severe limitations to the efficiency and response time of the electroluminescence. Modulation of gate bias in methylammonium lead iodide light-emitting transistors has proven effective in increasing the brightness of light emission up to MHz frequencies. In this work, a new approach is developed to improve charge carrier...
-
Compensation Topologies in IPT Systems: Standards, Requirements, Classification, Analysis, Comparison and Application
PublicationWireless power transfer devices are becoming more relevant and widespread. Therefore, an article is devoted to a review, analysis and comparison of compensation topologies for an inductive power transfer. A new classification of topologies is developed. A lot of attention is paid to the problems of the physical fundamentals of compensation work, standards, safety, and five main topology requirements. It is determined, that topologies...
-
Synchronized six-step voltage generation in high-speed PMSM drive
PublicationSynchronized voltage generation has already been considered in the context of pulse width modulation (PWM). References prove that synchronized PWM substantially decreases subharmonics in inverter output voltage when operating with low switching-to-fundamental frequency ratio. This paper identifies problems of unsynchronized voltage generation in electric drives under six-step inverter operation. Guidelines for the synchronization...
-
Searching of the buried objects into the sea bottom by means of nonlinear acouctic methods
PublicationThe main goal of this paper is to introduce the methodology of preparing the area for investigations that will be carried out at the sea. As the first step there is recognition of the basic method both in the theory as well as experimental investigation. There were taken into account the nonlinear methods. These ones are very promising methods that have very interesting features, very convenient for examinations of the seabed structure....
-
Performance Comparison of a 650 V GaN SSFET and CoolMOS
PublicationThe new technology of wide band gap semiconductors is said to outperform up-to-date silicon devices. High voltage Gallium Nitride (GaN) transistors, now emerging in the market, have even three times shorter switching times and even four times smaller energy losses compared to the best in-class Si devices. In this paper the performance of a 650 V GaN SSFET is evaluated and compared with the newest silicon family of CoolMOS™ technology....
-
Error analysis of calculating average d-q current components using Regular Sampling and Park transformation in FOC drives
PublicationIn electric drives using voltage source inverters, motor currents contain ripple component resulting from pulse-width modulated (PWM) voltage. The frequency range of the ripples is much higher than the bandwidth of current control. Therefore the control is performed on the basis of a fundamental current component, i.e. average value with the averaging time being the PWM period. In majority of cases the average current is measured...
-
Integrated Three-Level Dual-Phase Inverter
PublicationIn view of reducing the number of inverter legs that provide dual-phase, three-level output voltages (as may be needed in an uninterruptible power supply), and that also provide a wide range of output frequencies (as needed in an advanced motor drive system with wide speed ranges), a three-level, dual-phase inverter topology is presented in this paper. Its three-level attribute was based on the F-type inverter topological concept,...
-
Pulse-Width Modulation of Power Electronic DC–AC Converter
PublicationThe Second Edition of High Performance Control of AC Drives with Matlab®/Simulink delivers an updated and thorough overview of topics central to the understanding of AC motor drive systems. The book includes new material on medium voltage drives, covering state-of-the-art technologies and challenges in the industrial drive system, as well as their components, and control, current source inverter-based drives, PWM techniques for...
-
Selective Harmonic Elimination PWM For a Cascaded Multi-level Inverter
PublicationThis paper deals with the selective harmonic elimination pulse width modulation (SHE-PWM) technique. This technique is used for the elimination of selected dominant low order harmonics in the multi-level inverter output voltage. The presence of these harmonics is the essential drawback of such kind of inverters; especially when it is used for the control of different AC drivers. The SHE-PWM is based...
-
Structure and the space vector modulation for a medium-voltage power-electronic-transformer based on two seven-level cascade H-bridge inverters
PublicationThis study presents the structure and the space vector pulse-width modulation (SVPWM) for power electronic transformer (PET) based on two seven-level cascade H-bridge (CHB) inverters. The DC links of CHB inverters are coupled with nine dual-active bridge (DAB) converters with medium-frequency transformers. The DC-link voltages are equalised with two methods – through the control of DAB voltages...
-
A Five-Leg Three-Level Dual-Output Inverter
PublicationClassical 3-level dual-output inverter, 3-L DOI, involves two similar 3-level inverters that provides a pair of 3-phase output voltages with same or different frequencies from common input voltage source. Flexibility of either operation of the constituting inverters is evident in this DOI; but total duplication of power switches is a major drawback. State of the art coupled 3-L DOIs reduce this drawback by providing series-shared...
-
Mechanical Properties and Residual Stress Measurements of Grade IV Titanium and Ti-6Al-4V and Ti-13Nb-13Zr Titanium Alloys after Laser Treatment
PublicationNowadays, surface engineering focuses on research into materials for medical applications. Titanium and its alloys are prominent, especially Ti-6Al-4V and Ti-13Nb-13Zr. Samples made of pure grade IV titanium and the titanium alloys Ti-6Al-4V and Ti-13Nb-13Zr were modified via laser treatment with laser beam frequency f = 25 Hz and laser beam power P = 1000 W during a laser pulse with duration t = 1 ms. Subsequently, to analyze...