Filters
total: 2943
displaying 1000 best results Help
Search results for: MIXED METAL OXIDES
-
Hepatoblastoma, mixed epithelial-mesenchymal - Female, 3 - Tissue image [5190730046632231]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Female, 3 - Tissue image [5190730046635851]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Female, 3 - Tissue image [5190730046635201]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Female, 3 - Tissue image [519073004663171]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Female, 3 - Tissue image [5190730046631141]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Female, 3 - Tissue image [519073004663341]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Female, 3 - Tissue image [5190730046635421]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Female, 3 - Tissue image [5190730046635731]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Female, 3 - Tissue image [519073004663251]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Female, 3 - Tissue image [7040247104946081]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Female, 3 - Tissue image [5190730046634821]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Female, 3 - Tissue image [5190730046636461]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
INDIVIDUAL TREE DETECTION FROM UAV LIDAR DATA IN A MIXED SPECIES WOODLAND
Publication -
The Influence of the Mixed DPC:SDS Micelle on the Structure and Oligomerization Process of the Human Cystatin C
Publication -
Synthesis and characterization of periphery-functionalized porphyrazines containing mixed pyrrolyl and pyridylmethylamino groups
Publication -
Mixed electronic-ionic conductivity in vanadate oxide glasses containing alkaline ions
PublicationZbadano mieszane przewodnictwo polaronowo-jonowe w szkłach wanadanowych zawierających jony metali alkalicznych.
-
Effective dielectric constant of two phase systems: Application to mixed conducting systems
PublicationW pracy przedstawiono wyniki badań spektroskopii impedancyjnej systemów dwufazowych oraz ich porównanie z wynikami oczekiwanymi przez różne modele.
-
Lexicographic and weighting approach to multi-criteria portfolio optimization by mixed integer programming
Publication -
On electrical and photoconductive properties of mixed Nb2O5/TiO2 sol-gel thin films
PublicationPraca prezentuje wyniki przewodnictwa elektrycznego i fotoprzewodnictwa cienkich warstw TiO2 i Nb2O5/TiO2 otrzymanych metodą zol-żel. Pomiary przeprowadzono w funkcji temperatury i natężenia oświetlenia zarówno w próżni jak i w powietrzu. Struktura warstw została zbadana metodami XRD oraz AFM. W pracy zaobserwowano zaobserwowano spadek fotoprzewodnictwa wraz z zawartością Nb2O5
-
Almost homoclinic solutions for a certain class of mixed type functional differential equations
PublicationW pracy opisano pewną metodę aproksymacyjną szukania rozwiązań prawie homoklinicznych dla równań różniczkowo funkcyjnych z opóźnionym i przyśpieszonym argumentem. Podano również przykłady zastosowań tej metody.
-
Pointing device for elders with low cost and mixed manual-gaze control interface
PublicationW artykule przedstawiono projekt interfejsu pozwalającego na zastąpienie standardowej myszki komputerowej sterowaniem wzrokowym, z nieznacznym manualnym wspomaganiem. Manualne wspomaganie ma na celu korekcję współrzędnych kursora.
-
Effect of brookite on the photocatalytic properties of mixed-phase TiO2 obtained at a higher temperature
Publication -
Generalized solutions of mixed problems for first-order partial functional differential equations
PublicationW pracy udowodniono twierdzenie o istnieniu rozwiązań i ich ciągłej zależności od warunków początkowo brzegowych. Do przekształcenia zagadnienia oryginalnego w układ równań całkowo funkcyjnych typu Volterry użyto metody bicharakterystyk. Istnienie rozwiązań udowodnione jest metodą kolejnych przybliżeń, przy użyciu twierdzeń o nierównościach całkowych. Rozwiązania klasyczne układów równań całkowo funkcyjnych prowadzą do rozwiązań...
-
The mixed EIS-EQCM method for investigation of electrodeposition and electrodissolution of copper in acidic solution
PublicationCelem pracy jest połączenie chronowoltimpedancjometrii i mikrograwimetrii dobadania procesu elektroosadzania i elektroredukcji miedzi w środowisku kwaśnym. Proces elektroosadzania i elektroredukcji miedzi w środowisku kwaśnym został wybrany jako przykład prostej reakcji elektrochemicznej, by sprawdzić wiarygodność metody. Przedstawiono nową, obiecującą technikę - EIS-EQCM - jako metodę badania procesów niestacjonarnych, przebiegających...
-
Eficient multimode mixed time-frequency domain analysis and optimization of waveguide structures.
PublicationW pracy przedstawiona jest pełnofalowa analiza i optymalizacja struktur falowodowych o zadanej topologii. Nieciągłości falowodowe analizowane są z wykorzystaniem metody FDTD-IBC oraz scharakteryzowane uogólnioną macierzą rozproszenia. Efektywność metody zilustrowana jest na przykładzie filtru falowodowego siódmego rzędu.
-
Mixed integer nonlinear optimization of biological processes in wastewater sequencing batch reactor
PublicationWastewater treatment plays a key role for humanity. The waste entering lakes, rivers, and seas deteriorates daily quality of life. Therefore, it is very important to improve the efficiency of wastewater treatment. From a control point of view, a biological wastewater treatment plant is a complex, non-linear, multidimensional, hybrid control system. The paper presents the design of the optimizing hierarchical control system applied...
-
Eficient multimode mixed time-frequency domain analysis and optimization of waveguide structures.
PublicationW pracy przedstawiona jest pełnofalowa analiza i optymalizacja struktur falowodowych o zadanej topologii. Nieciągłości falowodowe analizowane są z wykorzystaniem metody FDTD-IBC oraz scharakteryzowane uogólnioną macierzą rozproszenia. Efektywność metody zilustrowana jest na przykładzie filtru falowodowego siódmego rzędu.
-
Measurements of passive components using of an IEEE 1149.4 mixed-signal test bus
PublicationW pracy przedstawiono wyniki badań nad wykorzystaniem magistrali testującej mieszanej sygnałowo IEEE 1149.4 do pomiarów elementów pasywnych zamontowanych na pakietach elektronicznych. Do badań użyto wyposażonych w magistralę układów scalonych typu STA400. Zaprezentowano metody pomiaru rezystancji pojedynczych elementów z wykorzystaniem źródła prądowego oraz źródła VH znajdującego się w analogowych modułach ABM układu STA400. Pokazano...
-
The Metal-Free Regioselective Deuteration of 2-Methylquinolin-8-ol and 2,5-Dimethylquinolin-8-ol, Spectroscopic and Computational Studies
PublicationAbstract: Aim and Background: Introducing deuterium to a molecule is of interest to a wide variety of research, including investigation of reaction mechanisms or kinetics, analysis of drug metabolism, structural elucidation of molecules, and syntheses of isotopically labeled materials used for NMR spectroscopy and medicinal research. Objective: The transition-metal-free regioselective deuteration of 2-methylquinolin-8-ol...
-
The role of aluminium in metal–organic frameworks derived carbon doped with cobalt in electrocatalytic oxygen evolution reaction
PublicationWater electrolysis is one of the most crucial processes in the development of new energy sources, where ultra-clean fuel is produced - hydrogen. Oxygen evolution reaction (OER) is the sluggish process of overall water splitting. Therefore, this study presents the design, characterization and electrochemical study of cobalt-based electrocatalysts embedded into porous carbons derived from an Al-metal–organic...
-
Miniaturized Metal-Mountable U-shaped Inductive-Coupling-Fed UHF RFID Tag Antenna with Defected Microstrip Surface
PublicationThis study presents a novel miniature ultra-high frequency (UHF) radio frequency identification (RFID) tag for metallic objects. Its arrangement includes a U-shaped feeder, which is inductively coupled to two E-type connected patches. Size reduction is achieved by means of utilizing the U-shaped feeder, and introducing a defection in the connection between the two E-type patches. The defection in the connection area between the...
-
Hepatoblastoma, mixed epithelial-mesenchymal - Male, 5 - Tissue image [5190730046639571]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Male, 5 - Tissue image [5190730046634371]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Male, 5 - Tissue image [5190730046635051]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Male, 5 - Tissue image [5190730046631461]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Male, 5 - Tissue image [5190730046636251]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Male, 5 - Tissue image [5190730046634271]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Male, 5 - Tissue image [5190730046632401]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Male, 5 - Tissue image [5190730046633801]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Male, 5 - Tissue image [5190730046637431]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Male, 5 - Tissue image [5190730046631861]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Male, 5 - Tissue image [5190730046633331]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Male, 5 - Tissue image [5190730046639431]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Male, 5 - Tissue image [5190730046639391]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Male, 5 - Tissue image [5190730046631611]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Hepatoblastoma, mixed epithelial-mesenchymal - Male, 5 - Tissue image [5190730046634681]
Open Research DataThis is the histopathological image of LIVER AND INTRAHEPATIC BILE DUCTS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
TEM imaging of metal nanoparticle cross section
Open Research DataTEM microscope was used for a imaging of metallic nanostructures. Metallic nanostructures were manufactured by thermal annealing of thin films. Gold and silver nanostructures were chosen for measurements. Samples were annealed for 15 and 60 minutes at 550 deg.
-
Electrical measurements of the dewetting of metal thin films
Open Research DataIn situ observations of dewetting of thin films is very complicated. One of the method, that helps to observe it, could be electrical measurements. For experiments, thin gold, silver and gold-silver nanoalloy films were deposited by magnetron sputtering method. Films were deposited on a Corning glass substrates. Samples were measured by four point method...
-
Metal-Organic Frameworks-Based Sensors for the Detection of Toxins in Food: A Critical Mini-Review on the Applications and Mechanisms
PublicationUsing scientific technologies to detect toxins in food is significant to prevent food safety problems and protect people’s health. Recently, the rise of sensors has made rapid, efficient, and safe detection of food toxins possible. One of the key factors impacting the sensor’s performance is the nanomaterials employed. Metal-organic frameworks (MOFs), with high specific surface area, tunable composition, porous structure, and flexible...
-
Titanium lanthanum three oxides decorated magnetic graphene oxide for adsorption of lead ions from aqueous media
PublicationThe current study presents a viable and straightforward method for synthesizing titanium lanthanum three oxide nanoparticles (TiLa) and their decoration onto the ferrous graphene oxide sheets to produce FeGO-TiLa as efficient magnetic adsorbent. Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), and vibration sample magnetometer (VSM) were used to evaluate...