Search results for: GREEN ANALYTICAL CHEMISTRY (GAC)
-
Analytical studies on the environmental state of the Svalbard Archipelago provide a critical source of information about anthropogenic global impact
Publication -
Environmental fate of endocrine disrupting compounds - analytical problems and challenges
PublicationNarażenie na substancje wykazujące się aktywnością hormonów płciowych może negatywnie wpływać na układ endokrynny i rozrodczy u ludzi i innych organizmów żywych. Badania wykazały że obserwowane są znaczne wzrosty przypadków występowania nowotworów piersi, prostaty i jąder. Inne zaś wykazały obniżoną liczbę plemników w nasieniu mężczyzn i wydłużenie czasu oczekiwania na poczęcie. Odkrycia te znajdują potwierdzenie w badaniach polowych...
-
Challenges in preparing honey samples for chromatographic determination of contaminants and trace residues
PublicationThe determination of contaminations and residues in honey is of growing concern over past few years, especially that these compounds can not only diminish beneficial properties of honey but more importantly, if present in significant amounts, can pose serious threat to human health. Since honey is characterized by complex composition of the matrix sample, it is often necessary to apply clean-up step, in order to eliminate interfering...
-
The state of the art in the field of non-stationary instruments for the determination and monitoring of atmospheric pollutants
PublicationW artykule przedstawiono informacje oparte zarówno na danych literaturowych jak i własnych doświadczeniach dotyczące:-podstawowych tendencji rozwojowych w zakresie analityki i monitoringu zaneczyszczeń powietrza atmosferycznego-wymogów metrologicznych stawianych różnych typom urządzeń kontrolno-pomiarowych;-klasyfikacji analizatorów i monitorów wykorzystywanych w monitoringu powietrza.
-
Progress in development of molecularly imprinted polymers as sorbents for sample preparation
PublicationSample preparation has been one of the most often investigated steps in analytical procedures.These investigations are focused on problems such as isolation of analytes from the sample matrix, matrix implification, analyte enrichment to the level above the detection limit of the instrumentation used, and the removal of interfering species to improve the final determination. Techniques based on solid (adsorption) and pseudo liquid...
-
Comparison Study on Sonodirect and Sonoalternate Current Electrocoagulation Process for Domestic Wastewater Treatment
Publication -
Process Optimization for Acid Hydrolysis and Characterization of Bioethanol from Leftover Injera Waste by Using Response Surface Methodology: Central Composite Design
Publication -
Analytical methodologies for determination of artificial sweeteners in foodstuffs- a review
PublicationArtificial high-intensity sweeteners are more and more frequently used for food production. Food industry tends to highlight beneficial aspects of their use, such as tooth-friendliness, rising-up quality of life of those suffering from different forms of diabetes and possibility of weight control without sacrificing favorite unhealthy drinks or snacks. On the other hand some of the consumers are deeply concerned about safety of...
-
Evolution of models for sorption of PAHs and PCBs on geosorbents.
PublicationWiedza o tym gdzie są zlokalizowane zanieczyszczenia obecne w osadzie oraz z jaką siłą związane są one z osadem jest niezbędna do oszacowania stopnia i skuteczności procesów remediacjyjnych oraz określenia dostępności, mobilności i toksyczności osadów. Dlatego, aby zrozumieć i poznać procesy zachodzące w tak skomplikowanej matrycy, jaką stanowią osady denne/gleby konstruowane są teoretyczne modele matematyczne opisujące prawdopodobny...
-
Environmental Fate of Traffic-Derived Platinum Group Metals
PublicationCiągle wprowadzane standardy odnośne emisji gaz spalinowych determinują rozwój przemysłu motoryzacyjnego oraz stymulują poszukwianie nowych przyjaznych środowiskowo rozwiązań dla transportu drogowego. Jednym z takich rozwiązań było wprowadzenie konwerterów gazów spalinowych w pojazdach mechanicznych które zawierały metali z grupy platynowców (PGM). Obok niezaprzeczalnych korzyści, zastosowanie PGM w konwerterach spalin nie jest...
-
Prospects for the production, research and utilizationof reference materials
PublicationW publikacji przedstawiono najważniejsze informacje i perspektywy użycia, badań i produkcji materiałów odniesienia. Dokładnie omówiono etapy produkcji materiałów odniesienia. Szczególną uwagę zwrócono na certyfikację i przygotowanie raportu z certyfikacji, a także na problemy występujące podczas stosowania materiałów odniesienia. Zaprezentowano różne sposoby interpretacji (graficzne i obliczeniowe) wyniku pomiaru z wartością certyfikowaną...
-
Urine composition as a source of information about occupational exposure to chemicals
PublicationIn the article there is presented review of data concerning application of human urine samples to analytical studies conducted in order to gain information on occupational exposure. The parameters characterizing the most commonly used techniques of xenobiotics isolation and preconcentration (organic compounds and metals) from urine samples and techniques of analytes determination in properly prepared extract samples of human urine.
-
Gradient reversed-phase high-performance chromatography of ionogenic analytes
Publication -
Critical approach to PLE technique application in the analysis of secondary metabolites in plants
Publication -
Perspectives and challenges in extracellular vesicles untargeted metabolomics analysis
Publication -
Recent achievements in element analysis of bee honeys by atomic and mass spectrometry methods
Publication -
Advances in assessing the elemental composition of distilled spirits using atomic spectrometry
Publication -
Chemical-vapor generation of transition metals through the reaction with tetrahydroborate in recent achievements in analytical atomic spectrometry
Publication -
Critical evaluation of recent achievements in low power glow discharge generated at atmospheric pressure between a flowing liquid cathode and a metallic anode for element analysis by optical emission spectrometry
Publication -
Development of direct-current, atmospheric-pressure, glow discharges generated in contact with flowing electrolyte solutions for elemental analysis by optical emission spectrometry
Publication -
Impact and practicability of recently introduced requirements on elemental impurities
Publication -
Cold atmospheric plasma-induced chemical vapor generation in trace element analysis by spectrometric methods
Publication -
Determination of aminoglycoside antibiotics: Current status and future trends
Publication -
Element analysis of bee-collected pollen and bee bread by atomic and mass spectrometry – Methodological development in addition to environmental and nutritional aspects
Publication -
Limitations of Integrative Passive Samplers as a Tool for the Quantification of Pharmaceuticals in the Environment – A Critical Review with the Latest Innovations
Publication -
Calibration of Passive Samplers for the Monitoring of Pharmaceuticals in Water-Sampling Rate Variation
Publication -
The Role of and the Place of Method Validation in the Quality Assurance and Quality Control (QA/QC) System
Publication -
Quality problems in determination of organic compounds in environmental samples, such as PAHs and PCBs
Publication -
Standard gas mixtures – indispensable reference materials in the analysis of gaseous media
Publication -
Gaseous standard mixtures – the challenge of obtaining small amounts of measurands
Publication -
Prospects for the Production, Research and Utilization of Reference Materials
Publication -
Validation of a sampling procedure
Publication -
Analytical Techniques Used in Monitoring of Atmospheric Air Pollutants
PublicationThe air pollution monitoring is one of the most pressing environmental problems today. The paper describes common air pollutants, their interaction and impact on the environment, and classifies the techniques and methods applied in air studies. Furthermore, the review characterizes the selected collection and sampling techniques used for gas sample analysis. Finally, the schematic diagrams of typical designs of systems applied...
-
Application of Passive Samplers in Monitoring of Organic Constituents of Air
PublicationThe principles of passive dosimetry, which has been known for over 100 years, are finding an ever increasing use in analytical practice and are being used as a convenient technique for isolation and enrichment of analytes from various environmental media. Due to its simplicity, a variety of designs, as well as the possibility of using a number of different final determination techniques, passive dosimetry has been applied in...
-
Applications of metal organic framework adsorbents for pipette-tip micro solid-phase extraction
Publication -
High Performance Liquid chromatography - Fourier Transform Infrared Spectroscopy Coupling: A Comprehensive Review
Publication -
Porous material-based sorbent coatings in Solid-phase microextraction technique: Recent trends and future perspectives
PublicationThe use of porous materials as sorbents in sample preparation techniques has gained recent scientific attention in the context of developing novel fibers for the Solid-phase microextraction (SPME) technique. SPME requires the appropriate selection of a robust sorbent for successful utilization under variable conditions. A deeper understanding of the nature of newly developed porous SPME coatings and the impact of their structures...
-
Environmental problems and health risks with disposable baby diapers: Monitoring of toxic compounds by application of analytical techniques and need of education
PublicationDue to the widespread use of disposable diapers in healthy babies as well as children prone to allergiesand premature babies with reduced immunity, disposable diapers should only be made of non-toxic andnatural ingredients. Unfortunately, disposable diaper manufacturers are reluctant to present their exactchemical composition, claiming that their trade secrets apply. However, several reports show thatdisposable diapers of well-known...
-
AGREEprep – Analytical greenness metric for sample preparation
PublicationThis work proposes for the first time, a metric tool that gives prominence to sample preparation. The developed metric (termed AGREEprep) was based on 10 categories of impact that were recalculated to 0 e1 scale sub-scores, and then used to calculate the final assessment score. The criteria of assessment evaluated, among others, the choice and use of solvents, materials and reagents, waste generation, energy consumption, sample...
-
Olfactory receptor-based biosensors as potential future tools in medical diagnosis
PublicationThe detection of biomarkers is the future of non-invasive medical diagnosis and screening. Discovery and identification of reliable disease specific volatile organic compounds is dependent on repeatable, accurate analysis of trace level gaseous analytes mainly in breath samples. Natural variety of the olfactory systems and the compounds capable of gas molecules binding creates wide possibilities of acquisition and implementation...
-
Quantum and carbon dots conjugated molecularly imprinted polymers as advanced nanomaterials for selective recognition of analytes in environmental, food and biomedical applications
PublicationSamples with complex matrix analyzed during explanation of pathogenesis of various diseases and food or environmental monitoring request advanced analytical and instrumental devices. Among the materials used for described purposes, quantum (QDs) or carbon dots (CDs) layered by molecularly imprinted polymer (MIP) shells have gained widespread attention. Unique optical and physicochemical properties of QDs/CDs together with high...
-
Evaluation of Langmuir and Freundlich Isotherms for Removal of Cephalexin and Tetracycline Antibiotics By Sistan Sand from Water and Wastewater Samples
PublicationIn this research, Sistan sand was used as a natural and inexpensive sorbent for removal of cephalexin and tetracycline antibiotics from water and wastewater samples. For a concentration 60.0 mg L-1 of cephalexin, optimum removal conditions were: pH of the sample 3.0, adsorbent amount 1.0 g, contact time 20.0 min, added amount of sodium chloride to adjust the ionic strength of the solution 7.0 g L-1. Langmuir isotherm was the best...
-
Bio-inspired approaches for explosives detection
PublicationDue to unique abilities of the animals regarding analysis of complex gas substances, they still remain a gold standard in analysis of explosives. Unusual capabilities of biological chemosensory systems, including both vertebrates and invertebrates, stimulate elaboration of the devices mimicking their activity and operation parameters as precisely as possible. The electronic analogues are a subject of investigation in many research...
-
Unconventional and user-friendly sampling techniques of semi-volatile organic compounds present in an indoor environment: An approach to human exposure assessment
PublicationThe commonly applied solutions used to assess the potential risk of human exposure to semi-volatile organic compounds (SVOCs) are based on the investigation of biological samples collected in an invasive or non-invasive manner. For SVOCs, which are typically introduced to humans through the respiratory system, dermal adsorption, or digestive system, sampling solutions generally used in the indoor environments are classified as...
-
Direct Analysis of Samples of Various Origin and Composition Using Specific Types of Mass Spectrometry
PublicationOne of the major sources of error that occur during chemical analysis utilizing the more conventional and established analytical techniques is the possibility of losing part of the analytes during the sample preparation stage. Unfortunately, this sample preparation stage is required to improve analytical sensitivity and precision. Direct techniques have helped to shorten or even bypass the sample preparation stage; and in this...
-
Prospects of ionic liquids application in electronic and bioelectronic nose instruments
PublicationThis paper addresses the problem of application of ionic liquids to chemical sensors and biosensors being an integral part of the electronic and bioelectronic-type instruments. The design and principle of operation of the electronic and bioelectronic noses are compared. Both the benefits and shortcomings of the application of ionic liquids in these type of instruments are described. The prospects of the development and application...
-
A Comprehensive Review on Shilajit: What We Know about Its Chemical Composition
Publication -
Trends in biomedical analysis of red blood cells – Raman spectroscopy against other spectroscopic, microscopic and classical techniques
Publication -
Current trends in analytical strategies for the determination of polybrominated diphenyl ethers (PBDEs) in samples with different matrix compositions – Part 2: New approaches to PBDEs determination
PublicationHerein, we review the latest technical solutions for polybrominated diphenyl ethers (PBDEs) determination in samples with different matrix compositions, largely focusing on gas chromatography but also presenting some liquid chromatography–based solutions. Moreover, we discuss the use of diverse sample injection techniques while considering the advantages and disadvantages of each injection system in the context of PBDEs analysis....
-
Preconcentration and Analytical Methods for Determination of Methyl Tert-Butyl Ether and Other Fuel Oxygenates and Their Degradation Products in Environment: A Review
PublicationFuel oxygenates (FOs) are mainly ethers or alcohols which are added to gasoline either to boost the octane number or to make the fuel burning process more "cleaner" with increasing the oxygen content, or to obtain a combination of both effects. FOs are water soluble with high mobility in the environment which presence even at very low concentrations lower the quality of water making it unsafe or unpleasant due to their objectionable...