Search results for: GNSS, PWV, WATER VAPOUR, TROPICS, CLIMATE MONITORING
-
Long-Term GNSS Tropospheric Parameters for the Tropics (2001-2018) Derived from Selected IGS Stations
PublicationThis paper describes dataset “Tropospheric parameters derived from selected IGS stations in the tropics for the years 2001-2018” contains GNSS-derived zenith tropospheric delay (ZTD), a posteriori corrected zenith wet delay (ZWD), and precipitable water vapour (PWV) time series. These troposphere-related data were estimated for the Jan 2001 – Dec 2018 period for 43 International GNSS Service (IGS) stations located across the global...
-
Hourly GNSS-derived integrated moisture in the global tropics for the years 2001-2018
Open Research DataGlobal tropics are essential in formulating weather patterns and climate across various latitudes through atmospheric teleconnections. Since water vapour is an essential parameter in atmospheric convection and, thus, latent heat release, its tropical variability on different time scales is crucial in understanding weather and climate changes. The provided...
-
Tropospheric parameters derived from the selected IGS stations in the global tropics for the years 2001-2018
Open Research DataThis dataset contains daily GNSS-derived zenith tropospheric delay (ZTD), a posteriori corrected zenith wet delay (ZWD), and precipitable water vapour (PWV) time series. These troposphere-related data were estimated for the period between January 2001 and December 2018, for the 43 International GNSS Service (IGS) stations, located in the global tropics....
-
Interannual Variability of the GNSS Precipitable Water Vapor in the Global Tropics
PublicationThis paper addresses the subject of inter-annual variability of the tropical precipitable water vapor (PWV) derived from 18 years of global navigation satellite system (GNSS) observations. Non-linear trends of retrieved GNSS PWV were investigated using the singular spectrum analysis (SSA) along with various climate indices. For most of the analyzed stations (~49%) the GNSS PWV anomaly was related to the El Niño Southern Oscillation...
-
Diurnal variability of atmospheric water vapour, precipitation and cloud top temperature across the global tropics derived from satellite observations and GNSS technique
PublicationThe diurnal cycle of convection plays an important role in clouds and water vapour distribution across the global tropics. In this study, we utilize integrated moisture derived from the global navigation satellite system (GNSS), satellite precipitation estimates from TRMM and merged infrared dataset to investigate links between variability in tropospheric moisture, clouds development and precipitation at a diurnal time scale. Over...
-
Analysis of GNSS sensed precipitable water vapour and tropospheric gradients during the derecho event in Poland of 11th August 2017
PublicationNowadays, one of the techniques that meets the increasing requirements of meteorologist in terms of monitoring of severe weather events is global navigation satellite systems (GNSS), which can provide information about the tropospheric state independently of the weather conditions and even in real time. In this paper we present the usage of GNSS sensed tropospheric data to monitor sudden and intense weather events. Our analyses...
-
Improved Empirical Coefficients for Estimating Water Vapor Weighted Mean Temperature over Europe for GNSS Applications
PublicationDevelopment of the so-called global navigation satellite system (GNSS) meteorology is based on the possibility of determining a precipitable water vapor (PWV) from a GNSS zenith wet delay (ZWD). Conversion of ZWD to the PWV requires application of water vapor weighted mean temperature (Tm) measurements, which can be done using a surface temperature (Ts) and its linear dependency to the Tm. In this study we analyzed up to 24 years...
-
Case study of water vapour transmission properties of EPDM façade membranes
PublicationThis research aimed to investigate the water vapour transmission properties of chosen EPDM membranes applied in façade and window systems under laboratory tests. The applied procedure included in national and international standards utilized for the laboratory tests of water vapour transmission properties of EPDM membrane is described. Two main types (outside and inside types) of EPDM membranes are laboratory tested. The authors...
-
Carbon Dioxide and Water Vapour Fluxes of a Alkaline Fen and Their Dependence on Reflectance
PublicationThis study shows results of parallel measurements of greenhouse gases fluxes (carbon dioxide and water vapour) and canopy reflectance of alkaline fen. Fluxes were measured using eddy-covariance technique on micrometeorological station located in the Upper Biebrza Basin (NE Poland) in Rogożynek Village. Study site is located in the Biebrza National Park which was established to protect one of the biggest coherent lowland wetland...
-
Adsorption-assisted transport of water vapour in super-hydrophobic membranes filled with multilayer graphene platelets
PublicationThe effects of confinement of multilayer graphene platelets in hydrophobic microporous polymeric membranes are here examined. Intermolecular interactions between water vapour molecules and nanocomposite membranes are envisaged to originate assisted transport of water vapour in membrane distillation processes when a suitable filler-polymer ratio is reached. Mass transport coefficients are estimated under different working conditions,...
-
Innovative Solutions in Surface Water Quality Monitoring
PublicationIn 2010 a project entitled "Integrated Support System for Management and Protection of Water Dam Reservoir (ZiZOZap)” was initiated, to aid solving water management problems on a river and dam reservoir formed on it. An innovative system of continuous monitoring was created, that encompassed selected physical and chemical parameters of river and lake waters in three chosen sites. This article presents a selection of results, that...
-
GNSS reference solution for permanent sition stability monitoring and geodynamical investigations - the ASG-EUPOS case study
PublicationThe aim of this paper is to present the strategy of determination of the reference solution for the ASG-EUPOS (ActiveGeodetic Network – European Position Determination System) coordinate monitoring system. ASG-EUPOS is a network of permanent GNSS (Global Navigation Satellite System) stations controlled by the Polish Head Office of Geodesy and Cartography (HOGC), which main role is to realize the ETRS89 (European Terrestrial Reference...
-
Robust Monitoring of Water Quality in Drinking Water Distribution System
PublicationThe paper develops a novel open loop set bounded observer for robust estimation of water quality in DWDS based on the advanced nonlinear quality dynamics model including disinfections by-products (DBPs). The observer utilises a cooperativeness of the quality dynamics model and is computationally efficient, hence applicable to on-line quality monitoring. The simulation results illustrate its good and sustainable performance.
-
Impact of Climate Change on Water Sources and River‐Floodplain Mixing in the Natural Wetland Floodplain of Biebrza River
PublicationThe origins of river and floodplain waters (groundwater, rainfall, and snowmelt) and their extent during overbank flow events strongly impact ecological processes such as denitrification and vegetation development. However, the long-term sensitivity of floodplain water signatures to climate change remains elusive. We examined how the integrated hydrological model HydroGeoSphere and the Hydraulic Mixing-Cell method could help us...
-
The protection and monitoring of a distribution piping network for potable water supply
PublicationPurpose – The purpose of this paper is to implement the corrosion protection method for steel pipes used in a municipal water-pipe network. Results of an inhibitor protection system installed on the system are presented. Inhibitor protection was required due to the high corrosivity of the water collected by a surface intake, which had resulted in a large number of failures and low water quality, due to the presence of corrosion...
-
GROUND WATER MONITORING AND REMEDIATION
Journals -
Journal of Water and Climate Change
Journals -
Euilibrium composition of CH4-CO2-CO-H2-H2O-C system under various compositions syngas methanation with 10% water vapour introduced
Open Research DataThe equilibrium compositions of CH4, CO2, CO, H2, H2O and C under the methanation reaction of various syngas mixtures (different CO/H2 ratio) were supplied with this dataset
-
Euilibrium composition of CH4-CO2-CO-H2-H2O-C system under various compositions syngas methanation with 30vol.% water vapour introduced
Open Research DataThe equilibrium compositions of CH4, CO2, CO, H2, H2O and C under the methanation reaction of various syngas mixtures (different CO/H2 ratio) were supplied with this dataset
-
Multi-sensor monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in utility water installations
PublicationThis paper presents an implementation of the monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in a utility water installation using an automated corrosion monitoring system. Due to the fact that the corrosion inhibitor was added to water intended for human consumption, it was necessary to build a multi-sensor monitoring system. In order to implement corrosion monitoring using a linear...
-
Euilibrium composition of CH4-CO2-CO-H2-H2O-C system under various compositions syngas methanation with 20vol.% water vapour introduced
Open Research DataThe equilibrium compositions of CH4, CO2, CO, H2, H2O and C under the methanation reaction of various syngas mixtures (different CO/H2 ratio) were supplied with this dataset
-
A global atmospheric electricity monitoring network for climate and geophysical research
Publication -
GNSS-based multi-sensor system for structural monitoring applications
Publication -
Network design for surface water quality monitoring in a road construction project using Gamma Test theory
PublicationRoad construction has a negative environmental impact on the surrounding aquatic environment, requiring the continuous monitoring of surface water quality. Here, optimization of the water quality monitoring network (WQMN) is an essential step in supporting the sustainable development of road construction projects. This study introduces Gamma Test theory (GTT) as a practical method for optimizing the WQMN of surface waters during...
-
Mariusz Figurski prof. dr hab. inż.
PeopleMariusz Józef Figurski (born 27 April 1964 in Łasinie, Poland) - Polish geodesist, professor of technical sciences, professor at the Gdańsk University of Technology. Early life and education He passed the matriculation examination in 1983 after he had finished Jan III Sobieski High school in Grudziądz. He graduated the Military University of Technology on an individual mode at the Faculty of Electromechanics and Civil Engineering...
-
Critical analysis of laboratory measurements and monitoring system of water-pipe network corrosion-case study.
PublicationCase study of corrosion failure of urban water supply system caused by environmental factors was presented. Nowadays corrosion monitoring of water distribution systems is an object of major concern. There is possibility of application broad range of techniques like gravimetric and electrochemical. Both kinds of techniques can be applied in laboratory and field conditions. In many cases researches limit the case analysis to measurements...
-
Monitoring of Chlorine Concentration in Drinking Water Distribution Systems Using an Interval Estimator
PublicationThis paper describes the design of an interval observer for the estimation of unmeasured quality state variables in drinking water distribution systems. The estimator utilizes a set bounded model of uncertainty to produce robust interval bounds on the estimated state variables of the water quality. The bounds are generated by solving two differential equations. Hence the numerical efficiency is sufficient for on-line monitoring...
-
The Application of a Mobile Unmanned Device for Monitoring Water and Sediment Pollution in the Port of Gdynia
PublicationPollution in the Port of Gdynia can encompass various types of substances and contaminants that affect the quality of water and sediment in this region. Ships entering and leaving the port can release pollutants such as oil, fuel, waste, and chemicals into the water. Controlling and monitoring these pollutants is a crucial part of environmental stewardship. In recent years, uncrewed units have been increasingly in use for in situ...
-
Assessment of the Water Needs of Fruit Plants in the Perspective of Climate Change
Publication -
Optimised Robust Placement of Hard Quality Sensors for Robust Monitoring of Quality in Drinking Water Distribution Systems
PublicationA problem of optimised robust placement of the hard quality sensors in Drinking Water Distribution Systems under several water demand scenarios for robust quality monitoring is formulated. Numerical algorithms to solve the problem are derived. The optimality is meant as achieving at the same time a desired trade off between the sensor capital and maintenance costs and resulting robust estimation accuracy of the monitoring algorithm...
-
(Vapour + liquid) equilibrium in (n,n-dimethylacetamide + ethanol + water) at the temperature 313.15 K
PublicationW pracy prezentowane są pomiary całkowitej prężności pary dla tytułowego układu trójskładnikowego oraz dla składowych układów binarnych. Uzyskane w pracy wyniki porównane zostały z wcześniejszymi danymi dla podobnych układów. Znaleziono w przybliżeniu liniową zależność pomiędzy wartościami nadmiarowej entalpii swobodnej Gibbsa a objętością molową amidu, spełnianą w układach dwuskładnikowych: amid + alkohol alifatyczny.
-
Sound velocity and parameter of nonlinearity of a ternary mixture consisting of water, vapour and dry air
PublicationRozpatruje się własności akustyczne mieszanki trójskładnikowej zawierającej wodę, parę wodną i suche powietrze. Dokładne obliczenia pozwoliły na wyprowadzenie prędkości dźwięku i parametru nieliniowości jako funkcji koncentracji pary wodnej i powietrza przy zadanych warunkach równowagowych. Rozpatrywane są dwa typy mieszanin. Przedstawiono wzory ogólne oraz symulacje numeryczne.
-
(Vapour and liquid) equilibrium in (N,N-dimethylacetamide+methanol+water) at the temperature 313.15 K.
PublicationPraca zawiera wyniki pomiarów całkowitej prężności pary dla tytułowego układu trójskładnikowego oraz dla ''składowych'' układów binarnych. Wyniki obliczeń nadmiarowej energii swobodnej mieszania dla układów (N,N-dimetyloaceta-mid+woda) i (N,N-dimetyloacetamid+metanol) porównane zostały z rezultatami uzyskanymi wcześniej dla innych układów (amid+metanol) oraz (amid+woda). Znaleziono interesującą zależność wartości nadmiaru...
-
Optimised Allocation of Hard Quality Sensors for Robust Monitoring of Quality in Drinking Water Distribution Systems
PublicationA problem of optimised placement of the hard quality sensors in Drinking Water Distribution Systems for robust quality monitoring is formulated. Two numerical algorithms to solve the problem are derived. The optimality is meant as achieving a desired trade off between the sensor capital and maintenance costs and resulting robust estimation accuracy of the monitoring algorithm. The robust estimation algorithm recently developed...
-
An optimised placement of the hard quality sensors for a robust monitoring of the chlorine concentration in drinking water distribution systems
PublicationThe problem of an optimised placement of the hard quality sensors in drinking water distribution systemsunder several water demand scenarios for a robust monitoring of the chlorine concentration is formulatedin this paper. The optimality is understood as achieving a desired trade off between the sensors and theirmaintenance costs and the accuracy of estimation of the chlorine concentration. The contribution of thiswork is a comprehensive...
-
THE IMPLICATIONS OF ECONOMIC DEVELOPMENT, CLIMATE CHANGE AND EUROPEAN WATER POLICY ON SURFACE WATER QUALITY THREATS
Publication -
DETERMINATION OF THE EFFECT OF ENVIRONMENTAL FACTORS ON THE CORROSION OF WATER DISTRIBUTION SYSTEM BASED ON ANALYSIS OF ON-LINE CORROSION MONITORING RESULTS
PublicationCorrosion of water distribution system is a significant issue causing problems with quality, safety and continuity of distribution. The changes of corrosion rates of the water distribution systems in Cracow made of carbon steel were investigated by analysis of online corrosion monitoring system results. Corrosion rates were determined using the linear polarization method. The impact of rain, temperatures, conductivity, dissolved...
-
Monitoring Salt Water Intrusion During Construction of a Road Tunnel under the Martwa Wisła River in Gdańsk
PublicationThe paper presents results of groundwater monitoring carried out during the construction of a road tunnel under the Martwa Wisła river in Gdańsk, Poland. Martwa Wisła is one of the branches of Wisła (Vistula) river, heavily influenced by storm surges and saline water inflow from the Bay of Gdańsk. Increased values of chloride concentration were observed on both sides of the river, in particular on the western side, which was caused...
-
Assessment of Water Needs of Grapevines in Western Poland from the Perspective of Climate Change
Publication -
Passive sampling techniques for monitoring pollutants in water
PublicationPraca przeglądowa poświęcona technice dozymetrii pasywnej. Omówiono charakterystykę wybranych próbników pasywnych wykorzystywanych w analityce zanieczyszczeń wody. Ponadto przedstawiono zalety i wady technik pasywnych oraz opisano obszar praktycznego zastosowania próbnikow pasywnych.
-
Automatic Watercraft Recognition and Identification on Water Areas Covered by Video Monitoring as Extension for Sea and River Traffic Supervision Systems
PublicationThe article presents the watercraft recognition and identification system as an extension for the presently used visual water area monitoring systems, such as VTS (Vessel Traffic Service) or RIS (River Information Service). The watercraft identification systems (AIS - Automatic Identification Systems) which are presently used in both sea and inland navigation require purchase and installation of relatively expensive transceivers...
-
An interval estimator for chlorine monitoring in drinking water distribution systems under uncertain system dynamics, inputs and chlorine concentration measurement errors
PublicationThe design of an interval observer for estimation of unmeasured state variables with application to drinking water distribution systems is described. In particular, the design process of such an observer is considered for estimation of the water quality described by the concentration of free chlorine. The interval observer is derived to produce the robust interval bounds on the estimated water quality state variables. The stability...
-
Monitoring and diagnosis of quality and quantity in drinking water systems.
PublicationArtykuł przedstawia nowe podejście do inteligentnego monitorowania oraz diagnostyki Systemu Wodnego (WS) jako problem statusu, warunków operacyjnych oraz rozpoznawania zdarzeń. Oprogramowanie komputerowego systemu monitorowania i diagnostyki zawiera narzędzia dla identyfikacji modeli dyskretnych statusów oraz określenia parametrów ilości i jakości wody dla każdego statusu. Dla każdego stanu decyzje podejmowane są przy użyciu metody...
-
GNSS reference solution for permanent station stability monitoring and geodynamical investigations: the ASG-EUPOS case study.
Publication.
-
Effective green ammonia synthesis from gaseous nitrogen and CO2 saturated-water vapour utilizing a novel photocatalytic reactor
Publication -
Water Needs of Sweet Cherry Trees in the Light of Predicted Climate Warming in the Bydgoszcz Region, Poland
Publication -
Effect of Forecast Climate Changes on Water Needs of Giant Miscanthus Cultivated in the Kuyavia Region in Poland
Publication -
A Climatic water balance variability during the growing season in Poland in the context of modern climate change
Publication -
<title>Fiber optic probe for monitoring of drinking water</title>
Publication -
Chemometrics in monitoring spatial and temporal variations in drinking water quality
PublicationOpracowanie przedstawia wyniki zastosowania wybranych technik chemometrycznych w monitoringu okresowych i powierzchniowych zmian jakości wody pitnej na podstawie wyników oznaczeń chloro i bromopochodnych produktów dezynfekcji wody w 12 dzielnicach w Gdańsku w okresie 1993-2000. Na podstawie wyników analizy podobieństwa lokalizacje podzielono na dwie grupy dzielnic różniących się jakością wody pitnej spowodowanej różnicami wynikającymi...