Search results for: VOLTAGE CONTROL, REACTIVE POWER CONTROL, LARGE CUSTOMER - Bridge of Knowledge

Search

Search results for: VOLTAGE CONTROL, REACTIVE POWER CONTROL, LARGE CUSTOMER

Search results for: VOLTAGE CONTROL, REACTIVE POWER CONTROL, LARGE CUSTOMER

  • The Large Customer Reactive Power Control Possibilities

    Publication

    n this paper the authors wish to draw attention to the rationale for, and the possibility of, the use of local reactive power sources by the Transmission Node Master Controller (TNMC). Large Customers (LC) are one of the possible reactive power sources. The paper presents the issues related to the need for coordination between the control systems installed in the LC network, and coordination between control systems of the LC as...

    Full text available to download

  • Voltage control in a power system with renewable sources of energy

    Publication

    - Year 2019

    Intensive development of distributed generation in power systems, caused by the European Union energy policy, gives possibility for improving safety in power delivery as well as optimizing the costs of the systems functioning. In this context, distributed generation can be used for voltage control in power systems – it can be performed by the control of reactive power of each source of energy or a group of energy sources. This...

    Full text to download in external service

  • VSC converters control for offshore wind farms HVDC grid connection

    Publication

    - Year 2013

    The paper proposes a voltage sourced converter (VSC) new control method. A well-known in the electric power systems correlation between voltage angle and active power and correlation between voltage and reactive power is used instead of feedforward control. This allows for a fast and almost independent control of active and reactive power flow.

    Full text to download in external service

  • Voltage and Reactive Power Load Flow Optimization in the Power System Using Fuzzy Logic

    The paper presents issues related to voltage control in the power system. An original method of reactive power flow optimization is considered, which leads to improved voltages in the power system and reduced active power losses. The optimization method is based on a procedure that employs fuzzy logic and is supported by a gradient search algorithm. The method has been implemented in PLANS software and verified.

    Full text available to download

  • Piotr Chrzan prof. dr hab. inż.

    Urodził się w 1954 r. w Sopocie. Jest absolwentem Wydziału Elektroniki Politechniki Gdańskiej (1978). W 1980 r. podjął pracę na Wydziale Elektrycznym w zespole prof. Jerzego Jaczewskiego. W 1988 r. uzyskał stopień naukowy doktora nauk technicznych, habilitację w 1999 r., w zakresie elektrotechniki: energoelektroniki i automatyki napędu, a tytuł profesora w 2017 r. Był promotorem 6 obronionych prac doktorskich (w tym 3 z wyróżnieniem)....

  • Numbers, Please: Power- and Voltage-Related Indices in Control of a Turbine-Generator Set

    Publication

    - ENERGIES - Year 2022

    This paper discusses the proper selection and interpretation of aggregated control performance indices values mirroring the quality of electrical energy generation by a turbine-generator set cooperating with a power system. Typically, a set of basic/classical and individual indices is used in energy engineering to ensure the mirroring feature and is related to voltage, frequency and active or reactive power deviations from their...

    Full text available to download

  • Simulation Studies of Control Systems for Doubly Fed Induction Generator Supplied by the Current Source Converter

    Publication

    - ENERGIES - Year 2021

    The control system for a Doubly Fed Induction Generator (DFIG) supplied by a grid-connected Current Source Converter (CSC) is presented in this paper. Nonlinear transformation of DFIG model to the multi-scalar form is proposed. The nonlinear control strategy of active and reactive power of DFIG is realized by feedback linearization. In the proposed control scheme, the DFIG model and CSI parameters are included. Two Proportional-Integral...

    Full text available to download

  • Feedback Control of Doubly-Fed Generator Connected to Current Source Converter

    Doubly-fed induction generator (DFIG) system supplied by current source converter (CSC) is considered in this article. The DFIG can work in two independent modes: AC grid connection and stand-alone mode. The DFIG is connected to the ac grid directly through its stator and the CSC links the rotor side. In this mode, the active and reactive powers of the DFIG must be controlled. This article proposes two control system structures...

    Full text to download in external service

  • Impact of R/X ratio of distribution network on selection and control of energy storage units

    Publication

    The interest in energy storage is still increasing. Energy storage units are installed in high voltage networks, medium voltage networks and low voltage distribution networks as well. These units are often used to improve power quality. One of the criteria for improving power quality is reducing voltage deviations. Depending on the type of network and specifying its R/X ratio, this criterion can be fulfilled by control of active...

    Full text to download in external service

  • TRANSFER OF ELECTRIC ENERGY [2023/24]

    e-Learning Courses
    • J. Klucznik

    Course content: Basic information on the structure of the power system, the major devices (components) for generation, transmission and distribution of electricity. Active and reactive power generation and their sources. Power supply networks. Tasks, structure, parameters. AC and DC transmission of electricity. Equivalent diagrams of the components of the power system. Steady state load flow calculation: currents, voltage,...

  • TRANSFER OF ELECTRIC ENERGY [2022/23]

    e-Learning Courses
    • J. Klucznik

    Course content: Basic information on the structure of the power system, the major devices (components) for generation, transmission and distribution of electricity. Active and reactive power generation and their sources. Power supply networks. Tasks, structure, parameters. AC and DC transmission of electricity. Equivalent diagrams of the components of the power system. Steady state load flow calculation: currents, voltage,...

  • TRANSFER OF ELECTRIC ENERGY [2024/25]

    e-Learning Courses

    Course content: Basic information on the structure of the power system, the major devices (components) for generation, transmission and distribution of electricity. Active and reactive power generation and their sources. Power supply networks. Tasks, structure, parameters. AC and DC transmission of electricity. Equivalent diagrams of the components of the power system. Steady state load flow calculation: currents, voltage, power,...

  • Nonlinear Control of a Doubly Fed Generator Supplied by a Current Source Inverter

    Publication

    Nowadays, wind turbines based on a doubly fed induction generator (DFIG) are a commonly used solution in the wind industry. The standard converter topology used in these systems is the voltage source inverter (VSI). The use of reverse-blocking insulated gate bipolar transistor (RB-IGBT) in the current source inverter topology (CSI), which is an alternative topology, opens new possibilities of control methods. This paper presents...

    Full text available to download

  • Problems of Connecting Wind Farms to the Power System with HV Cables

    Publication

    This paper presents problems caused by connecting wind farms to a power system with high voltage cables. The author highlights possible problems with reactive power compensation, depending on the arrangement of the shunt reactor connection and settings of control systems for reactive power and voltage of the wind farm. The paper also discusses issues of increasing active power losses caused by a shunt reactor installation.

    Full text available to download

  • Voltage and frequency regulation of a standalone induction generator by reduced-rating power electronic compensators - comparative evaluation

    Publication

    - Year 2015

    In this paper are considered two fundamental topologies of power electronic compensators for voltage and frequency control of a standalone self-excited induction generator (IG) system. These are voltage and current source inverter based shunt compensators with energy storage. The aim of this study is to assess main features of both topologies in dynamic and steady-state IG operation. The whole system is modelled with the aid of...

  • Integrated algorithm for selecting the location and control of energy storage units to improve the voltage level in distribution grids

    Publication

    This paper refers to the issue that mainly appears in distribution grids, where renewable energy sources (RES) are widely installed. In such grids, one of the main problems is the coordination of energy production time with demand time, especially if photovoltaic energy sources are present. To face this problem, battery energy storage units (ESU) can be installed. In recent years, more and more attention has been paid to optimizing...

    Full text available to download

  • Interconnection of the Customer-Side Resources Using Single Phase VAPF

    Publication

    - Year 2007

    The paper introduces method for utilization of the customer-side generated energy using single phase voltage active power filter. Structure and control method of the power electronics converter has been described and some simulation results are shown to prove usefulness of this arrangements. Proposed application realizes the following functions: power quality improvement, uninterruptible supplying and energy costs reduction.

    Full text to download in external service

  • Sensorless Rotor Position Estimation of Doubly-Fed Induction Generator Based on Backstepping Technique

    This paper proposes a speed observer algorithm for the sensorless control of a doubly-fed induction generator based on classical adaptive backstepping technique. The sensorless control is shown using classic stator field oriented control which is used to active and reactive power control. Performance of the proposed algorithm of a speed observer is validated by simulation and experimental results obtained using a small-rating generator...

    Full text to download in external service

  • SVC and power transformers controllers coordination

    Publication

    The use of shunt compensators such as FACTS (for example SVC) in power systems gives possibility of fast and flexible control of voltage or reactive power. An efficient cooperation between a transformer and compensator connected to busbars, or transformer’s tertiary winding, requires a proper coordination of controls. The article contains theoretical considerations and simulation results which indicate that such co-ordination is...

    Full text to download in external service

  • Laboratory Load Model Based on 150 kVA Power Frequency Converter and Simulink Real-Time – Concept, mplementation, Experiments

    Publication

    - Acta Energetica - Year 2015

    First section of the paper provides technical specification of laboratory load model basing on 150 kVA power frequency converter and Simulink Real-Time platform. Assumptions, as well as control algorithm structure is presented. Theoretical considerations based on criteria which load types may be simulated using discussed laboratory setup, are described. As described model contains transformer with thyristor-controlled tap changer,...

    Full text available to download

  • Lack of control over work and organizational citizenship behavior: overwork climate as a suppressor variable

    Open Research Data
    open access

    This study investigates a suppressor effect in the relationship between lack of control over work and organizational citizenship behavior (OCB). Suppressor effects operate when the addition of a predictor (in our study it is an overwork climate) increases the predictive power of another variable (lack of control over work) in predicting an outcome variable...

  • Symulacja pracy przesuwnika fazowego w sieci elektroenergetycznej przy połączeniu transformatora szeregowego w gwiazdę

    Poniższy artykuł prezentuje sposób regulacji mocy czynnej i biernej za pomocą przesuwnika fazowego, którego uzwojenie transformatora dodawczego (szeregowego) jest połączone w gwiazdę. W artykule pokazano regulację mocy czynnej i biernej na przykładzie wybranego systemu elektroenergetycznego. Omawiany przesuwnik fazowy reguluje jednocześnie przepływem mocy czynnej i biernej w danym systemie elektroenergetycznym.

    Full text available to download

  • Muhammad Jamshed Abbass Phd in Electrical Engineering

    People

    Muhammad Jamshed Abbass received the M.S. degree in electrical engineering from Riphah International University, Islamabad. He is currently pursuing the Ph.D. degree with the Wrocław University of Science and Technology, Wroclaw, Poland. His research interests include machine learning, voltage stability within power systems, control design, analysis, the modeling of electrical power systems, the integration of numerous decentralized...

  • Power electronic transformer based on cascaded H-bridge converter

    In this paper the control strategy of power electronic transformer (PET) is proposed. The analyzed structure of PET uses two seven-level cascaded H-bridge (CHB) rectifiers. The electrical power of PET is transferred between DC-links of CHB converters using dual-active-bridges (DABs) and low voltage high frequency transformers. The roposed solution allows for controlling the active and reactive power with a low level of harmonic...

    Full text available to download

  • The Influence of Limiters UEL and OEL (The power angle, stator's current and excitation current) ot the possibility of voltage collapse development

    Voltage stability has been a major concern for power system utilities because of event of voltage collapses in the recent past. Sometimes, power system events have shown the need for generators to operate in the overexcited and underexcited region to support stable operation. Modern excitation systems include devices for controlling or limiting machine terminal voltage (overvoltage limiters), volts per hertz ratio (V/Hz limiters),...

  • Static Series and Shunt-series PE Voltage-quality Controllers

    Publication

    - Year 2007

    As presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...

    Full text to download in external service

  • The Influence of LED Lighting Sources on the Nature of Power Factor

    Publication

    - ENERGIES - Year 2018

    This article presents measurements of electric power absorbed by a newly built facility for office and scientific research activities. These measurements highlighted the need for compensation of capacitive reactive power—not predicted by the designer—due to the vast use of LED lighting in the facility. The article also describes a reactive power compensation system, designed on the basis of the above-mentioned measurements, and...

    Full text available to download

  • Regulacja napięcia w sieci nN z rozproszonymi źródłami energii

    Publication

    Podłączanie rozproszonych źródeł energii do sieci energetycznych niskiego napięcia powoduje powstawanie problemów zmienności i niesymetrii napięcia, zwłaszcza w przypadku dużych odległości od transformatora zasilającego. W skrajnych przypadkach zachodzi konieczność redukcji mocy generowanej przez źródło podczas oddawaniu energii do sieci. Rozwiązaniem tego problemu jest zastosowanie energoelektronicznego regulatora napięcia składającego...

    Full text available to download

  • Measurements of reactive power distribution in a ship power station with two generators working in parallel

    Open Research Data
    open access
    • R. Maśnicki
    • D. Hallmann
    • J. Mindykowski
    • T. Tarasiuk
    • M. Górniak
    • B. Pałczyńska
    • M. Szweda

    The presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2),  developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing a reactive...

  • Comparative Analysis of Reactive Power Compensation Devices in a Real Electric Substation

    Publication
    • H. Tariq
    • S. Czapp
    • S. Tariq
    • K. M. Cheema
    • A. Hussain
    • A. H. Milyani
    • S. Alghamdi
    • Z. M. S. Elbarbary

    - ENERGIES - Year 2022

    A constant worldwide growing load stress over a power system compelled the practice of a reactive power injection to ensure an efficient power network. For this purpose, multiple technologies exist in the knowledge market out of which this paper emphasizes the usage of the flexible alternating current transmission system (FACTS) and presents a comparative study of the static var compensator (SVC) with the static synchronous compensator...

    Full text available to download

  • WARUNKI REZONANSOWE W WĘŹLE Z KOMPENSATOREM SVC

    Instalowanie kompensatorów statycznych w sieciach rozdzielczych i przesyłowych służy poprawie profili napięciowych. Kompensatory jako źródła mocy biernej zwiększają stabilność napięciową systemu. Pozwalają także na szybszą odbudowę systemu w przypadku awarii napięciowej. W artykule zaprezentowano wpływ struktury i wysterowania układu SVC na zmianę impedancji w układzie zasilania. Ma to bezpośredni wpływ na częstotliwości, przy...

    Full text available to download

  • Comparative analysis of switched reluctance motor control algorithms

    Publication
    • G. Demidova
    • Y. Derbikov
    • F. Petrikov
    • D. Lukichev
    • R. Strzelecki
    • A. Anuchin

    - Scientific and Technical Journal of Information Technologies, Mechanics and Optics - Year 2023

    Предмет исследования. Развитие микропроцессорной техники и силовой электроники позволило создавать недорогие и эффективные системы управления различными электромеханическими объектами, которые ранее широко не использовались из-за сложности управления. К таким устройствам можно отнести вентильно-индукторные электрические машины. Данные машины широко применяются в различных практических разработках, например, в тяговом электроприводе,...

    Full text available to download

  • Comparative analysis of switched reluctance motor control algorithms

    Publication
    • G. Demidova
    • Y. Derbikov
    • F. Petrikov
    • D. Lukichev
    • R. Strzelecki
    • A. Anuchin

    - Scientific and Technical Journal of Information Technologies, Mechanics and Optics - Year 2023

    Предмет исследования. Развитие микропроцессорной техники и силовой электроники позволило создавать недорогие и эффективные системы управления различными электромеханическими объектами, которые ранее широко не использовались из-за сложности управления. К таким устройствам можно отнести вентильно-индукторные электрические машины. Данные машины широко применяются в различных практических разработках, например, в тяговом электроприводе,...

    Full text available to download

  • Harmonics produced by traction substations – computer modelling and experimental verification

    Voltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion include traction rectifiers. This paper presents results of the computer investigation of...

    Full text available to download

  • Resonant Conditions in a Node with an SVC Compensator

    Publication

    - Acta Energetica - Year 2016

    The primary purpose of installing static shunt compensators in power grids is to improve the voltage conditions. Additional reactive power sources increase the system’s voltage stability and enable faster system recovery after a voltage failure. This paper presents the impact of an SVC device’s structure and settings on impedance change in the supply system, and hence on the frequencies at which resonance phenomena can develop.

    Full text available to download

  • Installation of Compensators in the Power System Transmission Grid

    Publication

    - Acta Energetica - Year 2019

    The article discusses issues of reactive power compensation in transmission grids, with particular focus on the selection of compensator locations and basic parameters. Attention was focused on modern power electronics systems that ensure full automatic compensator adjustment to voltage or power criteria.

    Full text available to download

  • Activity coordination of capacitor banks and power transformer controllers in order to reduce power losses in the MV grid

    Publication

    One of the main issues related to the optimization of the MV (middle voltage) network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility...

  • Higher harmonics produced by traction substations – computer modelling and experimental verification

    Voltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers, although the rms value of load current does not exceed their current-carrying capacity. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion...

    Full text to download in external service

  • Ancillary services to grids provided with distributed generation

    Publication

    - Year 2009

    The paper introduces system for utilization of the customer-side generated energy. Additionally system can secure some ancillary services to grids. Those services include: current active filtering, load voltage stabilization and in case of grid voltage faults - uninterruptible load supplying (possible with energy storage device). Presented experimental results confirm flexibility of this arrangement in processes of power delivery...

    Full text to download in external service

  • Jarosław Guziński prof. dr hab. inż.

    Jaroslaw Guzinski received M.Sc., Ph.D. and D.Sc. degrees from the Electrical Engineering Department at Technical University of Gdansk, Poland in 1994, 2000 and 2011 respectively. Since 2016 he is Associate Professor at Gdansk University of Technology. Currently he is the head of the Department of Electric Drives and Energy Conversion. From 2006 to 2009 he was involved in European Commission Project PREMAID Marie Curie, ‘Predictive...

  • Long-term measurements from a photovoltaic power plant and meteorological stations at the Laboratory LINTE^2 of Gdańsk University of Technology

    Open Research Data

    1)    The Laboratory LINTE^2 is a large research infrastructure operated by the Faculty of Electrical and Control Engineering at Gdańsk University of Technology, to be found in Gdańsk, Poland (54.3690 N, 18.6130 E). 2)    The measurements have been collected from a photovoltaic power plant located on the roof of the laboratory, having total capacity...

  • СИЛОВОЙ ПРЕОБРАЗОВАТЕЛЬ С АКТИВНЫМ ПОДАВЛЕНИЕМ ВЫСШИХ ГАРМОНИК ДЛЯ СИСТЕМ ЭЛЕКТРОСНАБЖЕНИЯ ЛЕТАТЕЛЬНЫХ АППАРАТОВ (Power converter with active suppression of higher harmonics for aircraft power supply systems)

    Publication

    - Izvestiya vysshikh uchebnykh zavedeniy. Priborostroenie - Year 2020

    Представлены два алгоритма активной фильтрации для силового преобразователя с активным подавлением высших гармоник. Первый алгоритм основан на дискретном преобразовании Фурье: посредством синтезированной системы управления инвертированные измеренные высшие гармоники напряжения поступают на вход инвертора. Второй метод управления основан на алгоритме с использованием принципов самообучения, что значительно снижает потребность в...

    Full text to download in external service

  • Active Power Quality Controllers

    Publication

    - Year 2008

    Dynamic Static Synchronous Compensator is the most important controller for distribution networks and probably in SEEN. It has been widely used since the 1990s to regulate system voltage precisely, improve voltage profile, reduce voltage harmonics, reduce transient voltage disturbances and load compensation. Rather than using conventional capacitors and inductors combined with fast switches, the D-STATCOM uses a power-electronics...

    Full text to download in external service

  • Tomasz Zubowicz dr inż.

    Tomasz Zubowicz has received his M.Sc. Eng. degree in Control Engineering from the Faculty of Electrical and Control Engineering at the Gda{\'n}sk University of Technology (GUT) in $2008$. He received his Ph.D. Eng. (Hons.) in the field of Control Engineering from the same faculty in $2019$. In $2012$ he became a permanent staff member at the Department of Intelligent Control and Decision Support Systems at GUT and a member of...

  • Estimation of Selected Synchronous Generator Parameters Based on the Gradient Method

    The authors present a method for the estimation of synchronous generator model parameters using a gradient algorithm. The paper shows an example of model parameter estimation for a turbogenerator and hydrogenerator, based on the generator voltage time responses obtained during an active and reactive power rejection test.

    Full text available to download

  • Estimation of Synchronous Generator and AVR Parameters Based on Gradient and Genetic Methods

    Publication

    The author present a method for the estimation of selected synchronous generator model and AVR parameters using a gradient and a genetic algorithm. The paper shows an example of model parameter estimation for a turbogenerator, based on the generator voltage time responses obtained during an active and reactive power rejection test

    Full text available to download

  • BEZCZUJNIKOWE STEROWANIE WOLNOOBROTOWYM SILNIKIEM PMSM Z KOMPENSACJĄ MOMENTU ZACZEPOWEGO

    W pracy przedstawiono propozycję rozwiązania problemu bezczujnikowego sterowania wolnoobrotową maszyną synchroniczną z magnesami trwałymi PMSM. Przedstawiono silnik PMSM, który zastosowano w stanowisku badawczym. Omówiono problem występowania tętnień momentu napędowego wynikający głównie ze znacznego momentu zaczepowego. Pokazano rozwiązanie kompensujące tętnienia momentu napędowego w silniku PMSM. Przygotowano procedurę startową...

    Full text available to download

  • Pompownie dużej mocy z falownikiem wędrującym średniego napięcia

    Artykuł zawiera rys rozwoju napędów przekształtnikowych w stacjach pomp, w szczególności regulacji wydatku kilku pomp, po kolei, przez jeden przemiennik częstotliwości. Omówiono podstawy teoretyczne zjawiska pola niestłumionego i napięcia resztkowego silników, które utrudniają szybkie przełączania silnika pompy pomiędzy zasilaniem regulowanym przez falownik a zasilaniem z sieci. Przedstawiono zasady transferu (przełączania) synchronicznego...

    Full text to download in external service

  • Evaluation of VSC Impact on Power System Using Adequate P-Q Capability Curve

    Publication

    - Electronics - Year 2023

    Renewable energy sources, which are becoming increasingly popular, often use a voltage source converter (VSC) for connection to the power system. Assessing the effects of connecting such a source to the power system is essential to ensure the proper operation of the power system and the connected source. For this purpose, it is necessary to know the range of active and reactive power generation by the converter. The authors indicate...

    Full text available to download

  • Measurements of power supply system properties of "Magnetic SpeedLine" ultra-fast robot prototype for IML labeling

    Open Research Data
    open access

    Tests of the power supply system of "SpeedLine magnetic" ultra-fast industrial robot for IML labeling were carried out to analyze the effect of the active power filter (APF) parameters on the power quality.  at the target duty cycle. Tests were performed with the target duty cycle. Linear synchronous motors with permanent magnets were used to drive...