displaying 1000 best results Help
Search results for: standard gas mixtures
-
Gas mixtures recognition using an array of amperometric gas sensors with drifting or faulty sensors
PublicationIn this study, the possibility of using selected methods for diagnostics of performance of matrix composed with six amperometric electrochemical gas sensors is investigated. Measurements of sensor responses in selected concentrations of single toxic gases or gas mixtures were performed and were repeated over time to show sensor drift. Additionally, the studies on the sensors’ drift were performed. The drift has been recognized...
-
Rozwój technik sporządzania gazowych mieszanin wzorcowych = Development of techniques of generation gaseous standard mixtures
PublicationW pracy przedstawiono rozwój dostępnych technik sporządzania gazowych mieszanin wzorcowych oraz informację na temat nowego podejścia do tego zagadnienia. W tym przypadku strumień składnika mierzonego (analitu) jest otrzymywany w procesie termicznego rozkładu związków powierzchniowych powstałych w trakcie procesu chemicznej modyfikacji powierzchni odpowiedniego stałego nośnika.
-
Limited selectivity of amperometric gas sensors operating in multicomponent gas mixtures and methods of selectivity improvement
PublicationIn recent years, smog and poor air quality have became a growing environmental problem. There is a need to continuously monitor the quality of the air. The lack of selectivity is one of the most important problems limiting the use of gas sensors for this purpose. In this study, the selectivity of six amperometric gas sensors is investigated. First, the sensors were calibrated in order to find a correlation between the concentration...
-
Analysis of odor interactions in ternary gas mixtures using electronic nose
PublicationIn recent years there has been a noticeable increase in interest in the use of electronic noses in analytical chemistry. These devices perform a holistic analysis of the gas mixtures composition, without the separation and identification of its individual components. For this reason e-noses are increasingly replacing the conventional olfactometers, due to the significantly shorter analysis time and possible automation. In the work...
-
Utilization of glass fibres as supports for surface compounds for generation of gaseous standard mixtures using thermal decomposition technique
PublicationPrzy oznaczaniu analitów na śladowym lub ultraśladowym poziomie stężeń, szczególnie w przypadku próbek o złożonym lub niejednorodnym składzie matrycy, analityk napotyka dodatkowe trudności techniczne i metodyczne związane z walidacją stosowanych procedur. Niezbędne jest zatem dysponowanie odpowiednimi wzorcami (lub lepiej materiałami odniesienia), które swoim składem są jak najbardziej zbliżone do składu próbek rzeczywistych. W...
-
Preparation of gaseous standard mixtures: methods for controlling the amount of components generated in the process of thermal decomposition of immobilized compounds.
PublicationGazowe mieszaniny wzorcowe odgrywają ważną rolę w ocenie metod analitycznych i urządzeń pomiarowych. W tym przypadku gazowe mieszaniny wzorcowe mogą być traktowane jako specjalny rodzaj materiału odniesienia.Proces walidacji wymaga użycia tzw. matrycowych materiałów odniesienia. Wybór techniki umożliwiającej uzyskanie gazowej mieszaniny wzorcowej o żądanych parametrach użytkowych zależy od natury składników mierzonych i gazu...
-
Kalibracja przyrządów analitycznych, wykorzystanie gazowych mieszanin wzorcowych. Calibration of analitycal instruments, utilization of gaseous standard mixtures
PublicationScharakteryzowano techniki kalibracji jakościowej i ilościowej. Przedstawiono również rolę gazowych mieszanin wzorcowych w procesie kalibracji przyrządów analitycznych oraz wpływ wyboru techniki sporządzania gazowych standardów na spójność pomiarową.
-
Wytwarzanie wzorcowych mieszanin gazowych za pomocą generatora pneumatycznegoGeneration of standard gaseous mixtures using pneumatic generator
PublicationW pracy przedstawiono konstrukcję pneumatycznego generatora wzorcowych mieszanin gazowych przeznaczonych do kalibracji różnych analizatorów gazów. Generator może także być wykorzystany do wytwarzania mieszanin oddechowych dla nurków pracujących na różnych głębokościach. Błąd bezwzględny wykonania mieszanin dwuskładnikowych i trójskładnikowych za pomocą skonstruowanego generatora nie przekracza 2%.
-
Determination of Odour Interactions of Three-Component Gas Mixtures Using an Electronic Nose
PublicationThe paper presents an application of an electronic nose prototype comprised of six TGS-type sensors and one PID-type sensor to identify odour interaction phenomena in odorous three-component mixtures. The investigation encompassed eight odorous mixtures—toluene-acetone-triethylamine and formaldehyde-butyric acid-pinene — characterized by different odour intensity and hedonic tone. A principal component regression (PCR) calibration...
-
Use of imidazolium ionic liquids for carbon dioxide separation from gas mixtures
PublicationNowoczesnym podejściem do separacji tlenku węgla (IV) z mieszanin gazowych jest zastosowanie cieczy jonowych jako materiału absorpcyjnego. Niemierzalna prężność par i możliwość modyfikacji budowy kationu i wyboru anionu cieczy jonowych sprawiają, że związki te mogą zastąpić obecnie stosowane aminy. Przedstawiono wpływ struktury chemicznej cieczy jonowych, ciśnienia oraz temperatury na efektywność absorpcji CO2 i innych gazów w...
-
Analysis of odour interactions in model gas mixtures using electronic nose and fuzzy logic
PublicationMeasurement and monitoring of air quality in terms of odour nuisance is an important problem. Although the source of these nuisances is different (e.g. wastewater treatment plants, municipal landfills), their common feature is that they are a complex mixture of odorants with different odour thresholds. An additional problem is occurrence of the odour interactions between mixture components. From a practical point of view, it would...
-
Application of fuzzy logic to determine the odour intensity of model gas mixtures using electronic nose
PublicationThe paper presents the possibility of application of fuzzy logic to determine the odour intensity of model, ternary gas mixtures (α-pinene, toluene and triethylamine) using electronic nose prototype. The results obtained using fuzzy logic algorithms were compared with the values obtained using multiple linear regression (MLR) model and sensory analysis. As the results of the studies, it was found the electronic nose prototype along...
-
Towards large-scale application of nanoporous materials in membranes for separation of energy-relevant gas mixtures
PublicationMembranes containing nanoporous materials (such as zeolites, metal–organic materials and 2D materials such as graphene derivatives) may allow more efficient separation of gas mixtures relevant to emerging energy technologies. For example, such membranes could be applied in the separation of gases containing mixtures of carbon dioxide (CO2) and hydrogen (H2). However, these membranes are currently at a relatively low technology...
-
Applicability of glass fiber as a support material for generation of gase ous standard mixtures using thermal decomposition of the surface compound. Calibration of analytical equipment.
PublicationW pracy przedstawiono technikę sporządzania gazowych mieszanin wzorcowych(składnikiem mierzonym był eten) w oparciu o termiczny rozkład związków powierzchniowych. Jako nośnik dla związku powierzchniowego zastosowano włókno szklane. W temperaturze 245 stopni Celsjusza związek powierzchniowy ulega rozkładowi bądź przegrupowaniu uwalniając znaną ilość analitu (etenu). Technika ta umożliwia sporządzanie gazowych mieszanin...
-
MoS2-containing composite membranes for separation of environmental energy-relevant liquid and gas mixtures: A comprehensive review
PublicationMolybdenum sulfide (MoS2) materials adapted into membranes have demonstrated potential for different areas dealing with molecular separations. For instance, MoS2-based membranes have been proposed for distinct environmental applications, such as water treatment, seawater desalination, gas separation, and solvent separation. Emergently, such membranes have been ultimately investigated for energy-relevant gas separation mixtures,...
-
Fungal co-culture improves the biodegradation of hydrophobic VOCs gas mixtures in conventional biofilters and biotrickling filters
PublicationThe present study systematically evaluated the potential of Candida subhashii, Fusarium solani and their consortium for the abatement of n-hexane, trichloroethylene (TCE), toluene and α-pinene in biofilters (BFs) and biotrickling filters (BTFs). Three 3.2 L BFs packed with polyurethane foam and operated at a gas residence time of 77 s with an air mixture of hydrophobic volatile organic compounds (VOCs) were inoculated with C. subhashii,...
-
Exhaust gas temperature measurements in diagnostics of turbocharged marine internal combustion engines. Part I. Standard measurements.
PublicationThe article discusses the problem of diagnostic informativeness of exhaust gas temperature measurements in turbocharged marine internal combustion engines. Theoretical principles of the process of exhaust gas flow in turbocharger inlet channels are analysed in its dynamic and energetic aspects. Diagnostic parameters are defined which enable to formulate general evaluation of technical condition of the engine based on standard...
-
FTIR spectra of gas mixtures from the methanation chamber filled with 50-50wt.% NiO-Al2O3
Open Research DataThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 50/50 wt.% NiO-Al2O3 catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
FTIR spectra of gas mixtures from the methanation chamber filled with 25-75wt.% NiO-Al2O3
Open Research DataThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 25/75 wt.% NiO-Al2O3 catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
FTIR spectra of gas mixtures from the methanation chamber filled with 50-50wt.% NiO-GDC
Open Research DataThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 50/50 wt.% NiO-GDC (Gadolinia Doped Ceria 20mol.%Gd2O3) catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.