Filters
total: 966
filtered: 30
Search results for: CATHODIC ACTIVATION
-
The electrochemical studies of CB-PLA surface activation by electrolysis in 1M NaOH
Open Research DataThe dataset contains the electrochemical studies performed under different conditions of surface activation of the CB-PLA 3D printed electrodes. The activation was performed by electrolysis in 1M NaOH solution under cycling polarization with different anodic or cathodic overpotentials (data in different subfolders). The file names contain the exact...
-
Partial PLA composite surface activation by femtosecond laser ablation
Open Research DataThe dataset contains the studies on electrochemical activity of PLA composite (commercially available CB-PLA Protopasta), which was 3D printed in a form of 1x1cm electrodes. The electrodes were submitted to femtosecond laser ablation, etching a certain % of the electrochemically-exposed electrode size. The % value is in the name of each file. The goal...
-
Partial PLA composite surface activation by femtosecond laser ablation
Open Research DataThe dataset contains the studies on electrochemical activity of PLA composite (commercially available CB-PLA Protopasta), which was 3D printed in a form of 1x1cm electrodes. The electrodes were submitted to femtosecond laser ablation operating with different parameters. These were: gas atmosphere (He or air, data in different subfolders), the percentage...
-
The electrochemical studies of CB-PLA electrode after surface activation by proteinase K digestion
Open Research DataThe dataset contains the electrochemical studies performed to evaluate surface activation of the CB-PLA 3D printed electrodes by enzymatic hydrolysis in a solution containing proteinase K (72h digestion period). Different enzyme concentrations were evaluated: 0.2, 0.4, 0.6 and 0.8 mg/ml. The studies were performed before surface activation, during and...
-
The cyclic voltammetry studies of CB-PLA electrode after surface activation by electrolysis in 1M NaOH
Open Research DataThe dataset contains the electrochemical studies performed for surface activation of the CB-PLA 3D printed electrodes by electrolysis in 1M NaOH solution. The studies were performed after treatment at an anodic overpotential of 1V, found to be optimal for surface activation. The measurements were carried out with cyclic voltammetry (CV) under different...
-
The electrochemical studies of CB-PLA electrode after surface activation by proteinase K digestion with different times and concentrations
Open Research DataThe dataset contains the electrochemical studies performed to evaluate surface activation of the CB-PLA 3D printed electrodes by enzymatic hydrolysis in a solution containing proteinase K. DIfferent proteinase K concentrations and digestion times were evaluated, as described in subfolder names. The studies were performed before surface activation, during...
-
Surface activation by cyclic polarization in 1M HCl and its effects on the electrochemical response of CB-PLA 3D printed electrodes
Open Research DataThe dataset contains the electrochemical studies performed for surface activation of the CB-PLA 3D printed electrodes by electrolysis in 1M HCl solution. The studies were performed after treatment at different polarization ranges, as labeled in subfolder names. For each electrode the consecutive studies describe different samples, as labeled in subfolders:...
-
Flow cytometry analysis of caspase 3/7 activation in A549, H460 and U2OS cells after exposure to TXT2 and TXT4
Open Research DataThe data contains flow cytometry analysis of caspase 3/7 activation in A549, H460 and U2OS cells after exposure to equitoxic concentrations of TXT2 and TXT4. DMSO and MTX were used as positive and negative controls, respectively. Caspase 3/7 activity was detected using CellEvent™ Caspase-3/7 Green Flow Cytometry Assay Kit (#C10427, Thermo Fisher Scientific)....
-
Hydrogenation process ofTiO2/BiVO4/PEDOT:PSS observed by XPS method
Open Research DataTitania nanotubes synthesis was based on a two-stage anodization process at water/ethylene glycol (5%/95%) electrolyte containing 0.27 M NH4F and 1 M H3PO4 described previously. Anodization process was performed in two-electrode cell compartment using platinum mesh as a cathode. The distance between electrodes was about 2 cm. The anodization voltage...
-
The XPS studies of the CB-PLA electrodes after different surface treatments (chemical, electrochemical, enzymatic)
Open Research DataThe dataset contains the Xray Photoelectron Spectroscopy results of the studies performed under different conditions of surface activation of the CB-PLA 3D printed electrodes. The activation was performed by hydrolysis in different solvents (DMF, 1M HCl, 1M NaOH), electrolysis in 1M NaOH, enzymatic treatment in polymerase or simultaneous electrolysis...
-
SEM micrographs of V2O5 nanorods as cathode material in Li-ion batteries
Open Research DataThe DataSet contains the scanning electron microscopy (SEM) micrographs of V2O5 nanorods as cathode materials before and after the galvanostatic charge/discharge curves.
-
Cycling performances of the V2O5 nanorods as cathode material in Li-ion batteries
Open Research DataThe DataSet contains the next one hundred galvanostatic charge/discharge curves of the V2O5 nanorods obtained by the sol-gel method. The battery tests of the samples were performed using the Atlas-Sollich 0961 (Atlas-Sollich, Poland) with C/5 and 2C current densities in the voltage range between 2.0 V and 4.0 V vs. Li/Li+. Here 1C is 294 mAh g-1. The...
-
Rate performance of the V2O5 nanocrystals as cathode material in Li-ion batteries
Open Research DataThe DataSet contains the galvanostatic charge/discharge curves of the V2O5 nanocrystals obtained by the sol-gel method. The battery tests of the samples were performed using the Atlas-Sollich 0961 (Atlas-Sollich, Poland) with different current densities in the voltage range between 2.0 V and 4.0 V vs. Li/Li+. Here 1C is 294 mAh g-1.
-
Cycling performances of the V2O5 nanostructures as cathode material in Na-ion batteries
Open Research DataThe DataSet contains the next one hundred galvanostatic charge/discharge curves of the V2O5 nanostructures with different morphology obtained by the sol-gel method. The battery tests of the samples were performed using the Atlas-Sollich 0961 (Atlas-Sollich, Poland) with C/5 current densities in the voltage range between 2.0 V and 4.0 V vs. Li/Li+. Here...
-
Cycling performances of the V2O5 nanocrystals as cathode material in Li-ion batteries
Open Research DataThe DataSet contains the next one hundred galvanostatic charge/discharge curves of the V2O5 nanocrystals obtained by the sol-gel method. The battery tests of the samples were performed using the Atlas-Sollich 0961 (Atlas-Sollich, Poland) with C/5 and 2C current densities in the voltage range between 2.0 V and 4.0 V vs. Li/Li+. Here 1C is 294 mAh g-1. ...
-
SEM micrographs of V2O5 nanocrystals as cathode material in Li-ion batteries
Open Research DataThe DataSet contains the scanning electron microscopy (SEM) micrographs of V2O5 nanocrystals as cathode materials before and after the galvanostatic charge/discharge curves.
-
Rate performance of the V2O5 nanorods as cathode material in Li-ion batteries
Open Research DataThe DataSet contains the galvanostatic charge/discharge curves of the V2O5 nanorods obtained by the sol-gel method. The battery tests of the samples were performed using the Atlas-Sollich 0961 (Atlas-Sollich, Poland) with different current densities in the voltage range between 2.0 V and 4.0 V vs. Li/Li+. Here 1C is 294 mAh g-1.
-
Rate performance of (NH4)2V10O25·8H2O as cathode material in Li-ion batteries
Open Research DataThe DataSet contains the galvanostatic charge/discharge curves of the ammonium vanadate nanostructures obtained by the hydrothermal method under an initial pressure of 50 bar ((NH4)2V10O25·8H2O). The battery tests of the samples were performed using the ATLAS 0961 MBI multichannel battery testing system with different current densities in the voltage...
-
Data from the survey on motivation to study abroad and criteria for choosing a place to study for foreign graduates of Gdańsk University of Technology
Open Research DataThe dataset includes data from the survey on the Gdańsk University of Technology foreign graduates’ on motivation to study abroad and criteria for choosing a place to study. The research was conducted over a four-month period, from December 2019 to March 2020, using the Computer-Assisted Web Interview (CAWI). The research sample included 142 respondents....
-
AFM investigation of electrode fabricated by 3D printing
Open Research Data3D printing, also known as additive manufacturing, has enjoyed great interest in recent years due to the versatility of this method of producing various shapes and details. Due to the possibility of precise control of the shape and composition of the printed elements, the discussed technique can be widely used in electrochemistry, including electrochemical...
-
Electrical and noise responses of carbon nanotube networks enhanced by UV light for nitrogen dioxide sensing
Open Research DataNetworks consisting of randomly oriented carbon nanotubes (CNN) were investigated toward nitrogen dioxide detection by means of electrical and low-frequency noise measurements. UV-activation of CNN layers improved gas sensitivity and reduced the limit of detection, especially by employing 275 nm-LED. This data set includes DC resistance measurements...
-
Rate performance of mixture (NH4)2V6O16 and (NH4)2V10O25·8H2O as cathode material in Li-ion batteries
Open Research DataThe DataSet contains the galvanostatic charge/discharge curves of the ammonium vanadate nanostructures obtained by the hydrothermal method without initial pressure (mixture (NH4)2V6O16 and (NH4)2V10O25·8H2O). The battery tests of the samples were performed using the ATLAS 0961 MBI multichannel battery testing system with different current densities...
-
Electrical conductivity relaxation measurements - water uptake of BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Open Research DataFor Electrical Conductivity Relaxation (ECR) measurements, platinum reversible electrodes were applied in a four-probe arrangement and the BaCe0.6Zr0.2Y0.1Tb0.1O3-δ sample was measured in the ProboStat™ measurement system. The ECR measurements were performed in air in the temperature range of 450-800 ℃ after switching water partial pressure between...
-
Electrical conductivity relaxation measurements - oxidation and reduction of BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Open Research DataThe dataset consists of 2 main catalogs: measurements performed for oxidation/reduction in dry conditions and in humid conditions. For Electrical Conductivity Relaxation (ECR) measurements, platinum reversible electrodes were applied in a four-probe arrangement and the sample was measured in the ProboStat™ measurement system. The ECR measurements were...
-
Bio based PUR-PIR foams thermal degradation (TG) and isoconversional kinetics
Open Research DataIn the present work, we perform a thorough thermogravimetric (TG) analysis of the bio-based polyurethane – polyisocyanurate (PUR-PIR) foams in both nitrogen and oxygen atmosphere. A sustainable element of the foam was a biopolyol obtained via acid-catalyzed liquefaction of Zostera Marina and Enteromorpha Algae biomass. Based on isoconversional analysis...
-
Electrochemical impedance spectroscopy measurements - conductivity vs. temperature and conductivity vs. oxygen partial pressure - BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Open Research DataThe dataset consists of two main catalogs consisting of measurement data: of the electrical conductivity of the BaCe0.6Zr0.2Y0.1Tb0.1O3-δ (BCZYTb) sample as a function of temperature and of the electrical conductivity as a function of oxygen partial pressure (pO2). Measurements as a function of temperature were carried out in dry and wet air (pH2O ~...
-
SEM micrographs of Ti tooth implant corrosion
Open Research DataThe dataset contains micrographs made with a scanning electron microscope (SEM) Hitachi S-3400N of the tooth implant removed after inflammation. The inflammation was induced by the increased corrosion rate of the titanium screw. The reason for the corrosion to occur was the appearance of the concentration cell of different aeration for various areas...
-
Data from the research into the opinions of foreign graduates at the Gdańsk University of Technology
Open Research DataThe dataset includes data from the survey on the Gdańsk University of Technology foreign graduates’ motivation to study abroad, criteria for choosing a place to study, assessment of satisfaction with graduating, professional careers, assitional activities undertaken during studies and socio-demographic characteristics . The research was conducted over...
-
The luminescence study of Bi-doped Cs2AgInCl6 double perovskite.
Open Research DataHere, we report a halide precursor acid precipitation method to synthesize Cs2AgIn1−xBixCl6 (x = 0, 0.02, 0.04, 0.08, 0.16, 0.32, 0.64, and 1) microcrystals. Cs2AgInCl6 and Bi derivative double perovskites show broadband white light emission via self-trapped excitons (STEs) and have achieved the highest internal quantum efficiency of up to 52.4% at...
-
Compliance with the restrictions during the COVID-19 pandemic in Poland and Sweden
Open Research DataOur study is aimed to check if the difference between Sweden and Poland in trust is related to negative affective reactions to authorities and law antipathy being manifestations of lack of trust and related to value-based legitimacy, behavioral legitimacy and prosocial justification of compliance with the restrictions put on citizens to limit the spread...