Filters
total: 1405
filtered: 878
-
Catalog
Chosen catalog filters
Search results for: PM10 DUST
-
Comparison of the tests for equivalence of the measurement methods for measurement of PM10 dust in ambient air
PublicationThe paper presents the motives for conducting the equivalence tests and the reasons of discrepancies between the results of PM10 dust concentration obtained via the reference method and the methods based on 'on-site' measurement. The reference and non-reference methods of measurement of PM10 dust concentration in air have been discussed. Field tests for equivalence, following the Polish standard and the European Union (EU) guidelines,...
-
Comparative field test for measurement of PM10 dust in atmospheric air using gravimetric (reference) method and b-absorption method (Eberline FH 62-1)
PublicationThe paper presents the results of a field test carried out in Gdansk region between 01-01-2010 and 31-12-2010 in order to demonstrate equivalence of the Eberline FH 62-1 sampler to the reference gravimetric method of suspended PM10 dust measurement. The differences in PM10 dust concentration provided by both methods have been discussed for different seasons of the year. A method of estimation of the correction factors/correction...
-
SZACOWANIE ZAWARTOŚCI BENZO(a)PIRENU W PYLE ZAWIESZONYM PM10 W AGLOMERACJI TRÓJMIEJSKIEJ ZA POMOCĄ WIELOWYMIAROWEJ REGRESJI LINIOWEJ=ESTIMATION OF BENZO(A)PYRENE CONTENT IN SUSPENDED DUST PM10 IN TRI-CITY AGGLOMERATION USING MULTIDIMENSIONAL LINEAR REGRESSION
PublicationW pracy przedstawiono próbę oszacowania przy pomocy wielowymiarowej regresji liniowej modelu empirycznego opisującego czynniki wpływające na zawartość B(a)P w pyle zawieszonym PM10 w Aglomeracji Trójmiejskiej w latach 2008-2011. Na przestrzeni tych lat średnioroczne stężenie B(a)P w PM10 wzrosło ponad dwukrotnie i ponad trzykrotnie przewyższa poziom docelowy. Z przeprowadzonych analiz wynika, że główną przyczyną wzrostu stężenia...
-
Niskokosztowe mierniki pyłu PM10
PublicationOchrona środowiska to jedna z dziedzin, w których ocena jakości powietrza atmosferycznego ma istotne znaczenie. Jakość powietrza zarówno wewnętrznego, jak i zewnętrznego jest jednym z kluczowych czynników wpływających na zdrowie człowieka. Ocena jakości powietrza nie jest jednak zadaniem łatwym. Powietrze jest bowiem złożonym układem, podlegającym zmianom nawet w krótkim czasie Jedną z głównych przyczyn występowania przekroczeń...
-
Cement kiln dust
PublicationThe volume of cement production in the world has remained at the level of approxi mately 4.1 billion tons/year. The cement production process is energy intensive and is the world’s leading emitter of carbon dioxide. Therefore, the main activities cement plants are aimed at introducing technologies changes in production of clinkier.The construction industry is responsible for the majority of CO2 emissions to the atmosphere: the...
-
Equivalence of on-line and reference methods for measurement of pm10 = Równoważność metod pomiarowych on-line i odniesienia stosowanych do oznaczania pm10
PublicationW badaniach nad równoważnością wyników otrzymanych za pomocą pomiaru ciągłego PM10 w stosunku do metody odniesienia stosuje się nienormatywny przewodnik unijny "Demonstration of Equivalence of Ambient Air Monitoring Methods. EC Working Group on Guidance for the Demonstration of Equivalence". W pracy omówiono sposób postępowania wg tego przewodnika. Na podstawie testu terenowego przeprowadzonego na terenie Gdańska w latach 2010-2011...
-
Influence of meteorogical conditions om PM10 concentration in Gdańsk
PublicationThe paper presents the investigation of influence of meteorological conditions on the concentration of PM!) in Gdańsk in 2011 year. on the examples of episodes og high concentrations in this year. The results have shown the most crucial factors for high episodes of PM10: anticyclone atmospheric circulation, stable atmosphere conditions, low wind velocity and the occurence of inversion layer.
-
Porównanie metod stosowanych do pomiaru pyłu PM10
PublicationW pracy przedstawiono krytyczny przegląd i porównanie metod oraz pyłomierzy stosowanych na stacjach pomiarowych w wojewódzwtwach pomorskim i warmińsko-mazurskim do pomiaru pyłu PM10, głównego zanieczyszczenia powietrza w tych województwach. Porównano trzy typy pyłomierzy stosowanych w większości stacji automatycznych i manualnych oraz przedstawiono nowatorskie rozwiazanie firmy Grimm.
-
Determination of benzo(a)pyrene content in PM10 using regression methods
PublicationThe paper presents an attempt of application of multidimensional linear regression to estimation of an empirical model describing the factors influencing on B(a)P content in suspended dust PM10 in Olsztyn and Elbląg city regions between 2010 and 2013. During this period annual average concentration of B(a)P in PM10 exceeded the admissible level 1.5-3 times. Conducted investigations confirm that the reasons of B(a)P concentration...
-
A MODEL FOR FORECASTING PM10 LEVELS WITH THE USE OF ARTIFICIAL NEURAL NETWORKS
PublicationThis work presents a method of forecasting the level of PM10 with the use of artificial neural networks. Current level of particulate matter and meteorological data was taken into account in the construction of the model (checked the correlation of each variable and the future level of PM10), and unidirectional networks were used to implement it due to their ease of learning. Then, the configuration of the network (built on the...
-
Testy równoważności metod pomiarowych dla pyłu zawieszonego pm10
PublicationCelem prowadzonych badań było wykazanie równoważności metody wagowej oznaczania pyłu PM10, spełniającej wymogi referencyjności, z metodami oznaczania "on-site" dla losowo dobranych par danych (4 symulacje). We wszystkich przypadkach równoważność określona została za pomocą trzech odrębnych analiz: zgodnie z procedurą opisaną w Normie Europejskiej EN 12341:1998 oraz z wykorzystaniem analiz regresji ortogonalnej i liniowej, w celu...
-
Comparison of PM10 concentration in Gdansk and London using electron microscopy
PublicationParticulate matter (PM) has been considered as one of the most dangerous elements of air pollution. Multiply analytical methods are employed to identify the composition of particles present in the air. The theoretical part of this work is a description of different research centres all over the world where particulate matter is being analyzed using various techniques. The purpose of this project is to analyze and compare particles...
-
The applicability of low-cost PM10 sensors for atmospheric air quality monitoring
PublicationDescribed in this work are the results of field tests carried out in the Tricity Agglomeration between 01 April 2018 and 30 June 2018 in order to evaluate the usefulness of low-cost PM10 sensors in atmospheric air quality monitoring. The results were juxtaposed with the results obtained using reference methods. The results were validated based on the measurement uncertainty as described in...
-
Zastosowanie niskokosztowych czujników PM10 do monitoringu jakości powietrza atmosferycznego
PublicationW pracy przedstawiono wyniki testu terenowego przeprowadzonego na terenie Gdańska w okresie od 7 do 24 lutego 2018 w celu wykazania wiarygodności uzyskiwanych wyników za pomocą komercyjnych czujników PM10 działających na zasadzie laserowego licznika cząstek w stosunku do metody odniesienia.
-
Microplastics in atmospheric dust samples of Sistan: sources and distribution
Publication -
Gust gdański?
PublicationTekst stanowi próbę syntetycznego opisu przemian estetyki architektonicznej w Gdańsku i powiązania jej z przekształceniami historyczno-kulturowymi zachodzącymi w mieście od XVI do XX w.
-
Test równoważności metod pomiarowych stosowanych do oznaczania pyłu zawieszonego PM10
PublicationW pracy przedstawiono przyczyny wystepowania różnic wartości stężeń pyłu PM10 uzyskiwanych metodą referencyjną a metodami opartymi na pomiarze w trybie on-site. Przedyskutowano metodykę wyznaczania równania bądź współczynnika korekcyjnego dla ciągłych metod pomiarowych w oparciu o unijną dyrektywę. Przeprowadzono weryfikację tej metodyki korzystając z danych uzyskanych z testu terenowego. Wyznaczono równanie korekcyjne przy pomocy...
-
Modelling Coarse Particulate Matter PM10 Concentration in the Tricity Area Using GIS
PublicationEnvironmental pollution is an issue of global concern, with Particulate Matter (PM) poisoning being a prime cause of lung cancer. This has led the European Commission to establish strict daily and annual PM concentration limits. The monitoring of air quality in major cities is the responsibility of European Member States. The Tricity, a 414.81 km 2 area in northern Poland, is monitored by a network of only 9 stations operated by...
-
Równoważność metod pomiarowych ciągłych i odniesienia stosowanych do oznaczania pm10
PublicationW pracy przedstawiono wyniki testu terenowego przeprowadzonego na terenie Gdańska w okresie od 01-01-2010 do 31-12-2010 i od 01-01-2011 do 31-12-2011 w celu wykazania równoważności wskazań analizatora Eberline FH 62-1 w stosunku do wagowej metody odniesienia. Przedyskutowano występowanie różnic wskazań wartości stężeń pyłu PM10 w zależności od pory roku dla obu metod pomiarowych. Przedstawiono sposób określania równoważności tych...
-
CLEANING METHODS FOR DUST DEPOSITED ON THE FRONT COVER OF PHOTOVOLTAIC MODULE
PublicationPhotovoltaic modules are one of the renewable energy sources with great potential for application in various regions of the world as well as for different terrain. They are, however, sensitive to external factors, affecting the overall amount of energy generated, such as solar irradiance, shading effects and any form of soil build-up on the front glass cover of solar device. The latter issue happens over a course of weeks, months...
-
Quasi Real-Time XRF Spectrometer in Source Apportionment of PM10 in a Typical Suburban Area
Publication -
The Analysis of Working Parameters Decrease in Photovoltaic Modules as a Result of Dust Deposition
PublicationThe aspect of dust accumulation on the surface of photovoltaic (PV) modules should be thoroughly understood in order to minimize possible obstacles affecting energy generation. Several elements affect the amount of pollutant gathered on the surface of a solar device, mainly its localization, which is irreversibly linked to factors such as annual rainfall, occasional snow coverage, or, in a dry climate, increased blow of dust during...
-
The Issue of Shading Photovoltaic Installation Caused by Dust Accumulation on the Glass Surface
PublicationThe issue of accumulation of dust and other pollutants on the surface of photovoltaic modules was thoroughly analysed over the years. One of the first surveys in this field of knowledge linked pollutant accumulation on the module surface with transmittance loss of its glass covering, which leads to lessened amount of solar radiation reaching solar cells. First stage of this accumulation process is linear transparency loss, and second...
-
Determination of bisphenol A in size fractions of indoor dust from several microenvironments
Publication -
Indoor allergens in settled dust from kindergartens in city of Łódź, Poland
Publication -
Site environment type – The main factor of urban road dust toxicity?
Publication -
Magnetic Susceptibility of Spider Webs and Dust: Preliminary Study in Wrocław, Poland
Publication -
Influence of cleaned granite dust on the properties of silicone pressure-sensitive adhesives
Publication -
Prototyp modelu systemu samouczącego do prognozowania stężenia pyłu PM10 w powietrzu atmosferycznym
PublicationArtykuł przedstawia model prognozowania stężenia pyłu PM10 z wykorzystaniem algorytmów genetycznych. Model ten jest drugim z kolei do prognozowania pyłu (poprzedni wykorzystywał jednokierunkowe sieci neuronowe) i stanowi podstawę do budowy modelu samouczącego. Podczas budowy modelu uwzględniono oddziaływanie czynników meteorologicznych, a do implementacji wykorzystano algorytm genetyczny ze względu na specyfikę problemu prognozowania...
-
Istota testu równoważności dla metod pomiarowych pyłu zawieszonego PM10 w powietrzu atmosferycznym
PublicationW pracy przedstawiono przyczyny przeprowadzania testów równoważności i występowania różnic wartości stężeń pyłu PM10 uzyskiwanych metodą referencyjną a metodami opartymi na pomiarze "on-site". Omówiono metodę referencyjną i metody niereferencyjne oznaczania pyłu PM10 w powietrzu. Przeanalizowano testy równoważności (terenowe) przeprowadzane przez Fundację ARMAAG na terenie Trójmiasta. Przedstawiono współczynniki korekcyjne uzyskane...
-
Zastosowanie analitycznej mikroskopii elektronowej w badaniach pyłów PM10 ze stacji Gdańsk - Wrzeszcz
PublicationPrzedstawiono wyniki pierwszych w Gdańsku badań pyłów z wykorzystaniem mikroskopii elektronowej. Opisano sposób przygotowania próbek do badań w SEM i TEM oraz wyniki analizy morfologicznej i jakościowej z użyciem widm EDS lub EDX. Stwierdzono występowanie 6 charakterystycznych grup pyłów o różnym składzie chemicznym i wielkościach zawierających się w przedziale 8-800 nm.
-
Particle Image Velocimetry Measurements of Airflow in Electrohydrodynamic Device for Dust Particle Collection
PublicationIn this paper the electrohydrodynamic (EHD)device for gas pumping and cleaning is presented. To induce an airflow in this EHD device corona discharge was used. The discharge was generated between the one-sided spike electrodes and the plate electrodes. An asymmetric electric field and generated discharge result in unidirectional gas flow through the EHD device. The current-voltage characteristics were measured and the corona discharge...
-
Particle Image Velocimetry Measurements of Airflow in Electrohydrodynamic Device for Dust Particle Collection
PublicationIn this paper the pumping effect of air in the electrohydrodynamic (EHD) device for dust particle collection is presented. To induce an airflow in this EHD device corona discharge was used. The discharge was generated between the one-sided spike electrodes and the plate electrodes. The asymmetric electric field and generated discharge resulted in a unidirectional airflow through the EHD device. The current-voltage characteristics...
-
Selected Metals in Urban Road Dust: Upper and Lower Silesia Case Study
Publication -
Boiling crisis - danger or a must?
PublicationW artykule przedstawiono zjawisko kryzysu wrzenia w przepływie. W głównej mierze skupiono się na zjawisku dryout'u podczas przepływu pierścieniowego. W pracy przedstawiono teoretyczny model wysychania filmu cieczowego na ściance wraz z jego modyfikacją w oparciu o model dwurównaniowy zaprezentowany przez Sedlera i Mikielewicza (1981). Model ten opiera się na bilansie cieczy w rdzeniu przepływu i w filmie cieczowym, gdzie głównym...
-
Szacowanie zawartości benzo(a)pirenu w pyle zawieszonym pm10 przy pomocy wielowymiarowej regresji liniowej
PublicationW pracy przedstawiono próbę oszacowania przy pomocy wielowymiarowej regresji liniowej modelu empirycznego opisującego czynniki wpływające na zawartość B(a)P w pyle zawieszonym PM10 w jednej z dzielnic aglomeracji trójmiejskiej, gdzie głównym źródłem występowania B(a)P była niska emisja, spowodowana spalaniem paliw kopalnianych. Analizie poddano wzajemne zależności: stężenia pyłu PM10 w powietrzu, temperaturę powietrza, prędkość...
-
Degradation of electrical performance of a crystalline photovoltaic module due to dust deposition in northern Poland
PublicationThe reduction in power output caused by the accumulation of dust on the photovoltaic module surface is an important problem and should receive much more attention in the literature. This study was an evaluation of the performance degradation of crystalline photovoltaic modules due to natural and simulated dust deposition. Dust is created from powdered grains of sand and particles of different bodies. Dust originates from different...
-
Influence of Rock Dust Additives as Fine Aggregate Replacement on Properties of Cement Composites—A Review
PublicationConcrete production consumes enormous amounts of fossil fuels, raw materials, and is energy intensive. Therefore, scientific research is being conducted worldwide regarding the possibility of using by-products in the production of concrete. The objective is not only to identify substitutes for cement clinker, but also to identify materials that can be used as aggregate in mortar and concrete productions. Among the potential alternative...
-
Mechanical Behavior of Plastic Strips-Reinforced Expansive Soils Stabilized with Waste Marble Dust
PublicationExpansive soil needs to undergo treatment to be used as safe foundation soil for roads and buildings. From an environmental conservation and economical point of view, the usage of agricultural and industrial wastes is the best option. In this study, the effects of utilizing plastic waste and marble waste dust on the engineering properties of expansive soils were examined. Various laboratory tests were carried out on sampled expansive...
-
Influence of Exhaust System Setup on Working Zone Pollution by Dust during Sawing of Particleboards
Publication -
Aqueous Mechanical Oxidation of Zn Dust: An Inventive Technique for Bulk Production of ZnO Nanorods
Publication -
Mechanical Behavior of Plastic Strips-Reinforced Expansive Soils Stabilized with Waste Marble Dust
PublicationExpansive soil needs to undergo treatment to be used as safe foundation soil for roads and buildings. From environmental conservation and economical point of view, the usage of agricultural and industrial wastes is the best option. In this study, the effects of utilizing plastic waste and marble waste dust on the engineering properties of expansive soils were examined. Various laboratory tests were carried out on sampled expansive...
-
Virtual teachers - a future or just a dream?
PublicationRozdział dotyczy tematyki inteligentnych systemów uczących, w tym szczególny nacisk jest położony na wizualizowane postaci pojawiające się w systemach zdalnej edukacji (wirtualni mentorzy, wirtualni nauczyciele). Rozdział wskazuje cele budowania wirtualnych nauczycieli i pokazuje wybrane zadania, które mogą one realizować. Opisuje kilka przykładów wirtualnych mentorów, w tym bota wirtualnego nauczyciela GERDA tworzonego na Wydziale...
-
Is reduced integration just a numerical trick
Publication -
AQUA-DUCT: a ligands tracking tool
Publication -
Cavitation Erosion of P110 Steel in Different Drilling Muds
PublicationThe P110 steel specimens were subjected to ultrasonic cavitation erosion in different compositions of drilling muds and surfactant additive. The test procedure was based on ASTM-G-32 standard recommendations. API 5CT-P110 steel is used for pipes in oil and gas industry. The harsh environment and high velocity of flows poses corrosive and erosive threat on materials used there. The composition of drilling fluid influences its rheological...
-
House dust as a source of analytical information on concentration of polybrominated diphenyl ethers (PBDEs) - first approach
PublicationPolybrominated diphenyl ethers (PBDEs), which are best recognized as flame retardants, were in 2001, by virtue of Stockholm Convention, listed in a group of Persistent Organic Compounds (POPs). Increasing concentration levels of PBDEs, reported in human tissues (e.g., blood, serum, breast milk, etc.) haverecently caught worldwide concern due to their potential tendency to disrupt thyroid hormones, neurobehavioral deficits and endocrine...
-
Compositional characteristics of black-carbon and nanoparticles in air-conditioner dust from an inhabitable industrial metropolis
Publication -
If Gravity is Geometry, is Dark Energy just Arithmetic?
PublicationArithmetic operations (addition, subtraction, multiplication, division), as well as the calculus they imply, are non-unique. The examples of four-dimensional spaces, R^4 and (−L/2,L/2)^4, are considered where different types of arithmetic and calculus coexist simultaneously. In all the examples there exists a non-Diophantine arithmetic that makes the space globally Minkowskian, and thus the laws of physics are formulated in terms...
-
"Just Culture" From the Perspective of Nursing Personnel
Publication