Filters
total: 9415
filtered: 7061
-
Catalog
Chosen catalog filters
displaying 1000 best results Help
Search results for: BONE REPAIR
-
Development of polyurethanes for bone repair
PublicationThe purpose of this paper is to review recent developments on polyurethanes aimed at the design, synthesis, modifications, and biological properties in the field of bone tissue engineering. Different polyurethane systems are presented and discussed in terms of biodegradation, biocompatibility and bioactivity. A comprehensive discussion is provided of the influence of hard to soft segments ratio, catalysts, stiffness and hydrophilicity...
-
Green engineered biomaterials for bone repair and regeneration: Printing technologies and fracture analysis
PublicationDespite the exceptional self-regeneration properties of bone, severe injuries often require additional surgical intervention such as using artificial bone constructs. These structures need to meet a number of criteria regarding their structure, performance, alongside the rate and the mechanism of erosion and fracture when implanted, for stimulating the regeneration of defected bone and, more critically providing support in the...
-
6.2, Engineering structures. [Chapter] 6.2.1, Assessment of the technical condition and repairs to cylindrical tank : 6.2.2, Assessment and repair of underground arterial pipelines : 6.2.4, Assessment and repair of steel chimneys
PublicationJerzy Ziółko opracował następujące fragmenty książki: w rozdziale 6.2. Engineering structures (Obiekty inżynierskie), pkt. 6.2.1 Assessment of the technical condition and repairs to cylindrical tank (Diagnostyka stanu technicznego i naprawy zbiorników walcowych), pkt. 6.2.2 Assessment and repair of underground arterial pipelines (Diagnostyka i naprawy podziemnych rurociągów magistralnych, pkt. 6.2.4 Assessment and repair of steel...
-
The cement-bone bond is weaker than cement-cement bond in cement-in-cement revision arthroplasty. A comparative biomechanical study
PublicationThis study compares the strength of the native bone-cement bond and the old-new cement bond under cyclic loading, using third generation cementing technique, rasping and contamination of the surface of the old cement with biological tissue. The possible advantages of additional drilling of the cement surface is also taken into account. Femoral heads from 21 patients who underwent a total hip arthroplasty performed for hip arthritis...
-
The acid strength of the datively bound complexes involving AlF3 lone pair acceptor and various lone pair donors
Publication -
Unusual and Conventional Dative Bond Formation by s2 Lone Pair Donation from Alkaline Earth Metal Atoms to BH3, AlH3, and GaH3
Publication -
Folding‐upon‐repair DNA nanoswitches for monitoring DNA repair enzymes activity
PublicationWe demonstrate here a new class of DNA‐based nanoswitches that, upon enzymatic repair, could undergo a conformational change mechanism leading to a change in fluorescent signal. Such folding‐upon‐repair DNA nanoswitches are synthetic DNA sequences containing O6‐methyl‐guanine (O6‐MeG) nucleobases and labelled with a fluorophore/quencher optical pair. The nanoswitches are rationally designed so that only upon enzymatic demethylation...
-
Repair Augmentation of Unstable, Complete Vertical Meniscal Tears With Bone Marrow Venting Procedure: A Prospective, Randomized, Double-Blind, Parallel-Group, Placebo-Controlled Study
Publication -
Therapeutic intervention by the simultaneous inhibition of DNA repair and type I or type II DNA topoisomerases: one strategy, many outcomes
PublicationMany anticancer drugs reduce the integrity of DNA, forming strand breaks. This can cause mutations and cancer or cell death if the lesions are not repaired. Interestingly, DNA repair-deficient cancer cells (e.g., those with BRCA1/2 mutations) have been shown to exhibit increased sensitivity to chemotherapy. Based on this observation, a new therapeutic approach termed 'synthetic lethality' has been developed, in which radiation...
-
Damage repair of the double shell tank
PublicationPłaszcz wewnętrzny stalowego zbiornika dwupłaszczowego o pojemności 10000 m3 został zdeformowany w wyniku błędu popełnionego podczas próby wodnej przy odbiorze zbiornika. W referacie omówiono technologię naprawy silnie zdeformowanego płaszcza zbiornika. Stosowano roztłaczanie hydrauliczne, prostowanie mechaniczne i termiczne oraz wymianę najbardziej uszkodzonych blach.
-
Necessary covariance conditions for a one-field Lax pair
PublicationBadamy kowariancje w odniesieniu do transformacji Darboux wielomianowych różniczkowych i różnicowych operatorów z współczynnikami danymi przez funkcje jednego bazowego pola.
-
Author Reply to “Regarding ‘Repair Augmentation of Unstable, Complete Vertical Meniscal Tears With Bone Marrow Venting Procedure: A Prospective, Randomized, Double-Blind, Parallel-Group, Placebo-Controlled Study’”
Publication -
Influence of Polymorphisms in DNA Repair GenesXPD, XRCC1andMGMTon DNA Damage Induced by Gamma Radiation and its Repair in LymphocytesIn Vitro
Publication -
EXPERIMENTS AND SIMULATIONS FOR LAPAROSCOPICVENTRAL HERNIA REPAIR IMPROVEMENT
PublicationThe authors conducted a wide experimental and numerical study in order to determine effective approaches in the laparoscopic VH repair. At first the study covered identification of mechanical properties of the abdominal fascia, implants, tacks and transabdominalsutures. Basis on these data, the one and two-dimensional mathematical models were formulated and a number of numerical static and dynamic analyses were carried out. Then...
-
Optimization and control of tissue growth and repair in bioreactor.
PublicationPraca przedstawia model matematyczny procesu optymalizacji i odnowy hodowanej w bioreaktorze tkanki. Model matematyczno-numeryczny umożliwia właściwy dobór parametrów w trakcie hodowli w celu uzyskania pożądanych efektów w zakresie fizyko-chemicznych właściwości rozmnażającej się tkanki. Charakterystyką o znamionach nowości jest wieloparametrowość optymalizacji w zakresie hodowli tkanek.
-
Safety and efficacy of a Ventralight ST echo ps implant for a laparoscopic ventral hernia repair – a prospective cohort study with a one-year follow-up
Publicationing new products Thus, every mesh prior to introduction in clinical settings should be tested with a dedicated tacker to discover the proper fixation algorithm. The aim of the study was to assess the safety and efficacy of the Ventralight ST implant with an ECHO positioning system and a dedicated fixation device, the SorbaFix stapler, in a prospective cohort of patients. Material and methods. The study was a prospective single...
-
Antibacterial Activity and Cytocompatibility of Bone Cement Enriched with Antibiotic, Nanosilver, and Nanocopper for Bone Regeneration
PublicationBacterial infections due to bone replacement surgeries require modifications of bone cement with antibacterial components. This study aimed to investigate whether the incorporation of gentamicin or nanometals into bone cement may reduce and to what extent bacterial growth without the loss of overall cytocompatibility and adverse effects in vitro. The bone cement Cemex was used as the base material, modified either with gentamicin...
-
The diagnostic accuracy of cone beam computed tomography in detecting temporomandibular joint bony disorders: a systematic review
Publication -
Common variants of DNA repair genes and malignant melanoma
Publication -
Mechanical properties of mosquito nets in the context of hernia repair
PublicationThe paper deals with issue of applying mosquito nets as implants in hernia repair, which have already been used in resource-poor developing countries. Uniaxial tensile tests have been conducted on polyester mosquito meshes in two orthogonal directions. Non-linear elastic constitutive laws parameters have been identified to be applied in dense net material models. Mechanical performance of tested mosquito nets has been compared...
-
Two-criteria optimisation problem for ventral hernia repair
PublicationTwo-criteria optimisation problem related to laparoscopic ventral hernia repair is formulated in this paper. An optimal implant from a given set and its orientation is sought. The implant is subjected to kinematic extortions due to a patient’s body movement and intra-abdominal pressure. The first criterion of the optimisation problem deals with the reaction force in the implant fastener, while the deflection of the implant constitutes...
-
A Method Supporting Monitoring And Repair Processes of Information Systems
PublicationW pracy zaproponowano nową metodę (ARM) zarządzania monitorowaniem i naprawą systemów IT, bez przerywania ciągłości ich funkcjonowania. Metoda ta integruje procesy monitorowania (uwzględniając już istniejące i stosowane rozwiązania) z procesami naprawy. Stworzono formalny model koncepcyjny opisujący dziedzinę monitorowania i naprawy oraz formalne specyfikacje mechanizmu napraw oraz wybranych procedur naprawczych. Do specyfikacji...
-
Towards automating repairs of IT systems
PublicationThis paper presents formal description of working principles of the repair library, being the essential component of the Repair Management Framework (RMF), which aims at automating the process of repairing IT systems, and consists also of the Repair Management Model (RMM) and the Repair Management System (RMS). RMM introduces two mathematical models (model of monitoring and model of repair processes), general enough to cover the...
-
A system automating repairs of IT systems
PublicationThis paper presents two problems that are important nowadays: the problem of IT systems monitoring and the problem of repairing them. It shows the developed solution, aimed to automate the existing industrial repair process and to integrate it with the existing monitoring solutions and mechanisms. Described solution is a part of a bigger whole, called the Repair Management Framework (RMF). This paper presents also briefly a case...
-
Towards automation of IT systems repairs
PublicationMonitoring and repair are two sides of the on-the-fly maintenance of IT systems.Monitoring is well supported by automatic tools. In contrast, repairs involve much higherhuman intervention which negatively affects reliability and efficiency. The paper intro-duces a method of automating repairs of IT systems which can be integrated with any ofthe existing monitoring mechanisms. The method is described as a collection of modelsand...
-
Short ultrasonic waves in cancellous bone
Publication -
Three-Dimensional Printing of Bone Models
PublicationThe trabecular bone occurs, for example, in the femoral heads. Understanding the phenomenon of bone tissue degeneration can be the basis for the possibility of looking for alternative methods of surgical treatment of bone loss. The paper presents the results of the trabecular bone model, which was produced in additive manufacturing method with fused filament fabrication technology. The verification of the mechanical behavior of...
-
Tribology of bone tissue culture in bioreactor.
PublicationOpracowano system tribologiczny powstających sił tarcia w bioreaktorze. Pomimo, że wartości sił tarcia osiągają wartości poniżej 0,1 N to mają one decydujący wpływ na wartość porostu tkanki. Mechanika opływu tkanki cieczą o właściwościach biologicznych nienewtonowskich oraz hydrodynamiczna teoria opływu warstwy przyściennej jest bazą wyznaczania parametrów trybologicznychniniejszej pracy.
-
Assessment of usefulness of different tacks in laparoscopic ventral hernia repair
PublicationLaparoscopic ventral hernia repair is becoming a popular technique with good results and fast postoperative recovery. The mesh is placed directly under the peritoneum and anchored with transabdominal sutures and tacks. However, the ideal size of the mesh covering the hernia orifice is know, nor the ideal type or amount of tacks has to be described.
-
Mechanical Modelling of Human Fascia in the Problem of Ventral Hernia Repair
PublicationPraca dotyczy badań doświadczalnych tkanki ludzkiej oraz symulacji numerycznej zachowania tej tkanki. Na podstawie eksperymentu dokonuje się identyfikacji modelu materiałowego tkanki a następnie w celu wweryfikacji przeprowadza się symulacje numeryczną zachowania modelowanej struktury. Celem badań jest uzyskanie informacji przydatnych podczas leczenia przepuklin brzusznych u ludzi.
-
Experimental Study on Polymer Mass Used to Repair Damaged Structures
Publication -
Paraesophageal Hernia Repair Followed by Cardiac Tamponade Caused by ProTacks
Publication -
MutL protein as a constituent of vsp, ner and mmr repair systems
PublicationMutS and MutL proteins are renowned mostly for their functions in well-characterized, post-DNA replication mis- match repair system (MMR). However, there is growing evidence that MMR system is not the only field of action for these pro- teins. Moreover, the participation in MMR does not even have to be their primary function. There are some reports indicat- ing involvement of MutL in BER, NER and VSP (very short patch repair)....
-
Mathematical modelling of implant in an operated hernia for estimation of the repair persistence
PublicationThis paper presents mathematical modelling of an implanted surgical mesh used in the repair process of the abdominal hernia. The synthetic implant is simulated by a membrane structure. The author provides a material modelling of the implant based on the dense net model appropriate for technical fabrics. The accuracy of the proposed solution is evaluated by comparing the simulations of the dynamic behaviour of the system with the...
-
Experimental study on polymer mass used to repair damaged structures
PublicationA new method of repairing damaged structures by injecting the cracks with specially designed polymer mass (flexible two-component grout based on polyurethane resin) has been recently proposed. The technique is mainly dedicated to damaged masonries, especially historical structures where minimum intervention is permitted. The cracks are filled with the special injection, forming the flexible joints bonding the disrupted structural...
-
SIMULATION OF PROCEED® SURGICAL MESH APPLIED TO VENTRAL HERNIA REPAIR
PublicationIn the present research, Proceed® implant is considered. The system is subjected to short-time dynamic pressure load, similar to post-operative cough naturally occurring in human abdomen. The model refers to a clinical case of 5cm of hernia operated by Proceed implant fixed by 15 joints every 3cm around the orifice. The simulations of the implanted mesh are performed by means of the Finite Element Method. The implant is modelled...
-
Mechanical compatibility of implants used in hernia repair with abdominal wall
PublicationThe paper deals with a membrane model of a synthetic surgical mesh for treatment of abdominal hernia. The authors analyse the compatibility of two implant types with the human wall: Dualmesh Gore and Proceed. The finite element method is applied to simulate tjhe behavior of the proposed model. Due fact that recurrences are usually caused by connection failure, this study is focused on reaction forces in supports representing the...
-
Technological Considerations of Periodic Repair Works of Concrete Industrial Floors
PublicationConcrete floors are among the elements in construction facilities whose design requires engineering experience, workmanship requires the maintenance of a technological regime, while during their operation it is necessary to conduct periodic repairs. Concrete floors are most often used as working and communication space in industrial facilities, and very often they are also a functional element in objects that are immovable monuments....
-
Bone Metabolism and Dental Implant Insertion as a Correlation Affecting on Marginal Bone Remodeling: Texture Analysis and the New Corticalization Index, Predictor of Marginal Bone Loss—3 Months of Follow-Up
Publication -
Evaluation of the Elastomeric Composite Self-repair Process for the Construction of Protective Gloves
Publication -
DNA repair is responsible for the presence of oxidatively damaged DNA lesions in urine
Publication -
In vivo performance of intraperitoneal onlay mesh after ventral hernia repair
PublicationBackground: Ventral hernia repair needs to be improved since recurrence, postoperative pain and other complications are still reported in many patients. The behavior of implants in vivo is not sufficiently understood to design a surgical mesh mechanically compatible with the human abdominal wall. Methods: This analysis was based on radiological pictures of patients who underwent laparoscopic ventral hernia repair. The pictures...
-
IMPLANT USED IN HERNIA REPAIR UNDER PHYSIOLOGICAL MOVEMENTS OF HUMAN ABDOMEN
PublicationThe study deals with the mechanical behaviour of implant used in repair of abdominal hernia. The influence of orientation of the orthotropic implants in different areas of abdominal wall is studied.
-
Orthotropic membrane as a mechanical model of surgical implant in abdominal hernia repair
PublicationEven though the incisional hernia repair surgery is a well known procedure, mechanical properties of the tissue-implant system are unknown so the implantation of the repairing mesh is quite intuitive and, recurrences of the illness still take place. The main objective of the study is to define an operated hernia model that can be used for surgery planning and the assessment of the repair persistence. The load applied to the structure...
-
Safety assessment of a concrete viaduct damaged by vehicle impact and an evaluation of the repair
PublicationDamage to lower parts of viaducts caused by impact from under-passing high vehicles is relatively frequent. One such incident, in which a viaduct was damaged by the impact from a truck with an improperly assembled hydraulic crane, is considered in this work. The analysis is based on a detailed object damage evaluation, 3D laser scanning, and numerical simulations. The aim of the study is to accurately model the vehicle impact into...
-
Underwater Wet Repair Welding of API 5L X65M Pipeline Steel
PublicationThis paper presents results of the research of effect of polymer insulation of pipeline made of API 5L X65M steel as well as underwater wet welding parameters on properties of joints made by covered electrodes. Effect of heat input on structure and hardness of joints during repair of underwater pipeline was analyzed. Welding defects like microcracks, micro-lacks of fusion, slag inclusions, as well as HAZ hardness increase over...
-
Dynamics of mechanical model of implant-tissue system in ventral hernia repair
PublicationThe paper deals with a finite element modelling of implants in the problem of ventral hernia repair. The synthetic mesh implanted in the abdomen during surgery is here modelled as a membrane structure. Thesystem undergoes the internal abdominal pressure that occurs during the postoperative cough, the load identified in the literature as the main cause of the connection failure and hernia recurrence. The model can be used to estimate...
-
Porous materials used as inserted bone implants
PublicationArtykul zawiera przegladowa analize literatury dotyczaca scaffoldow
-
Analisys of the failure of fixator used in bone surgery
PublicationThe Gamma nail (fixator) made of stainless steel, which has broken in the body, was subjected to examination. The fixator was removed from the patient femur. The fracture occurred in the area of the nail hole after two months' stay in the organism. The research included chemical composition, hardness of the Gamma nail material and the observation and analysis of the type of fracture. The research showed the fatigue failure of the...
-
Bone status in adolescents with type 1 diabetes
Publication