Filters
total: 5488
filtered: 4795
-
Catalog
Chosen catalog filters
displaying 1000 best results Help
Search results for: IMPEDANCE ANALYZER
-
Miniaturized impedance analyzer using AD5933
PublicationThe paper presents the analyzer allowing to measure impedance in a range of 10 ohms <|Zx|<10 Gohms in a wide frequency range from 10 mHz up to 100 kHz. The device specific features are: miniaturization, low power consumptions and the use of impedance measurement method based on DSP. These features were possible thanks to the use of newest generation of large scale integration chips: e.g. „system on a chip” microsystems (AD5933)...
-
Miniaturized impedance analyzer using AD5933
PublicationThe paper presents the analyzer allowing to measure impedance in a range of 10 ohms <|Zx|<10 Gohms in a wide frequency range from 10 mHz up to 100 kHz. The device specific features are: miniaturization, low power consumptions and the use of impedance measurement method based on DSP. These features were possible thanks to the use of newest generation of large scale integration chips: e.g. „system on a chip” microsystems (AD5933)...
-
Analyzer for spectroscopy of low-impedance objects
PublicationW artykule przedstawiono analizator umożliwiający pomiar impedancji w zakresie 1 ohma < |Zx| < 100 Mohma. Zastosowano w nim nowe rozwiązania dotyczące obwodu wejściowego i techniki detekcji fazoczułej sygnałów pomiarowych. Obwód wejściowy zaprojektowano w postaci 5-zaciskowej sondy pomiarowej, która umożliwia ograniczenie wpływu rezystancji, indukcyjności i pojemności pasożytniczych na błąd pomiaru impedancji w szerokim przedziale...
-
An analysis of a measurement probe for a high impedance spectroscopy analyzer
PublicationW artykule przedstawiono sondę będącą obwodem wejściowym analizatora do spektroskopii wysokoimpedancyjnej. Sonda umożliwia pomiar impedancji jednym zaciskiem uziemnionej w zakresie od 100ohm do 100Gohm. Sonda umożliwia wydzielenie dwóch sygnałów proporcjonalnych do prądu i napięcia na impedancji mierzonej w szerokim zakresie częstotliwości od 100uHz do 100MHz.Przeprowadzono analizę sondy w której uwzględniono najważniejsze czynniki...
-
An analysis of a measurement probe for a high impedance spectroscopy analyzer
PublicationW artykule przedstawiono sondę będącą obwodem wejściowym analizatora do spektroskopii wysokoimpedancyjnej. Sonda umożliwia pomiar impedancji jednym zaciskiem uziemnionej w zakresie od 100ohm do 100Gohm. Sonda umożliwia wydzielenie dwóch sygnałów proporcjonalnych do prądu i napięcia na impedancji mierzonej w szerokim zakresie częstotliwosci od 100uHz do 100MHz.Przeprowadzono analizę sondy w której uwzględniono najważniejsze czynniki...
-
The high impedance measuring probe for gain-phase analysers.
PublicationAutorzy opracowali tanią sondę pomiarową przeznaczoną do pracy z analizatorami gain-phase jak Solartron 1260 Impedance/Gain-phase Analyser, 1255 Frequency Response Analyser (FRA) lub starszymi wersjami 1250, 1253. Przedstawiona architektura sondy wyznacza jej parametry metrologiczne. Pomiary możliwe są w 8 zakresach obejmujących wartości 100ohm<|Zx|<100Gohm w szerokim zakresie częstotliwości 10uHz-1MHz. Obwód wejściowy sondy pozwala...
-
A family of new generation miniaturized impedance analyzers for technical object diagnostics
PublicationThe paper presents the family of three analyzers allowing to measure impedance in range of 10 ohm<|Zx|<10 Gohm in a wide frequency range from 10 mHz up to 100 kHz. The most important features of the analyzers family are: miniaturization, low power consumption, low production cost, telemetric controlling and the use of impedance measurement method based on digital signal processing DSP. The miniaturization and other above mentioned...
-
Polymer membranes loaded with lipids for taste sensing: electrochemical impedance spedance spectroscopy studies
PublicationZcharakteryzowano metodą impedancyjnej spektroskopii elektrochemicznej membrany polichlorku winilu z lipidami zanurzone w roztworze kwasu cytrynowego. Badano membrany elektrod dodatnio naładowanych (heksadecyloamina, chlorek, benzyloheksadecylodimetyloamoniowy) i ujemne naładowanych (kwas elaidynowy, cholesterol, l-dodekonol). Badania impedacyjne pozwoliły na rozróznienie czterech stałych czasowych: rezystancja wysokiej częstotliwości,...
-
ARUZ - Analyzer of Real Complex Systems
Publication -
Linearization in impedance measurements
Publication -
Impedancje i składowe prądu zaburzeń w obwodach z łącznikami półprzewodnikowymi = Impedances and disturbance current components in the circuits with semiconductor switches
PublicationW referacie przedstawiono pewien sposób określenia impedancji i składowych prądu zaburzeń dla przypadku obwodu z łącznikiem półprzewodnikowym. Określono widmową impedancje obciążenia i impedancje wewnętrzną źródła oraz rozpływy składowych prądu zaburzeń. Zaprezentowano wyniki obliczeń dla pewnego przypadku obwodu. W wnioskach omówiono wpływ przyjętego układu zastępczego źródła zaburzeń oraz częstotliwości charakterystycznej na...
-
Polynomial description of dynamic impedance spectrogram—introduction to a new impedance analysis method
PublicationThis paper presents a polynomial description of spectrograms obtained using Dynamic Electrochemical Impedance Spectroscopy. A method to fit the polynomial degree correctly is discussed. A simple electrical system of a diode connected in parallel with a capacitor was used for testing. Dynamic impedance measurements during potentiodynamic polarization were conducted. This paper presents an alternative analysis method that allows...
-
Technology of real-world analyzers (TAUR)
Publication -
Local impedance spectroscopy of membranes
Publication -
Differential analysis of impedance data
Publication -
The amplitude analysis of impedance spectra
Publication -
Local impedance spectroscopy of membranes
PublicationCelem niniejszej publikacji jest zaprezentowanie zastosowania techniki Lokalnej Elektrochemicznej Spektroskopii Impedancyjnej (LEIS) do uzyskania lokalnej charakterystyki membran. Membranę wykonaną z polichlorku winylu (PCV), plastyfikowaną sebacynianem bis(2etyloheksylu) i domieszkowaną boranem tetradodecyloamoniowym zbadano pod kątem równomiernego rozkładu przewodnictwa na powierzchni badanej próbki. Lokalne pomiary impedancyjne,...
-
Impedance of metastable pitting corrosion
PublicationPrzeprowadzono badania impedancyjne metastabilnego procesu korozji wżerowej. Kształt chwilowych widm impedancyjnych otrzymanych w wyniku eksperymentu jest ściśle związany z przebiegiem prądu dc. O szybkość korozji wewnątrz aktywnego zaatakowania decyduje proces przeniesienia ładunku. Ekspansja aktywnej powierzchni jest proporcjonalna do zmian podwójnej warstwy elektrycznej. Zaobserwowane zostały również zmiany rezystancji elektrolitu...
-
Measuring the impedance of ultrasonic transducers.
PublicationW przypadku przetworników ultradźwiękowych charakteryzujących się zazwyczaj bardzo zmienną w funkcji częstotliwości impedancją jej pomiar stwarza szereg trudności. Nie nadają się do tego celu tanie, łatwo dostępne, przyrządy. Znane są drogie systemy badawcze stosowane do tego celu. Zazwyczaj przystosowane są one do takich pomiarów w szerokim paśmie częstotliwości, od pasma akustycznego aż do zakresu mikrofalowego. Natomiast,...
-
Correction methods in impedance spectroscopy
PublicationW pracy przedstawiono trzy grupy metod, ktÓre mogą być zastosowane do korekcji danych pomiarowych uzyskanych za pomoca spektroskopii impedancyjnej.
-
Design of a modular impedance tomography
PublicationW pracy przedstawiono konstrukcję, zasadę działania oraz podstawowe parametry tomografu impedancyjnedo przeznaczonego do pomiarów w gruncie.
-
Polynomial analysis as a new way of describing dynamic impedance spectra – Differential and relative impedance spectra
PublicationModel measurements of an equivalent electrical system were carried out using the technique of Dynamic Electrochemical Impedance Spectroscopy. The measurement took the form of potentiodynamic changes imposed on the tested system. Using the possibility of continuous impedance measurements, an attempt was made to develop an original and innovative method of analyzing impedance spectrograms, which is termed polynomial analysis. As...
-
Validity of impedance spectra obtained by dynamic electrochemical impedance spectroscopy verified by Kramers-Kronig transformation.
PublicationArtykuł przedstawia weryfikację wiarygodności widm impedancyjnych otrzymanych za pomocą niedawno wprowadzonej techniki eksperymentalnej - Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej (Dynamic Electrochemical Impedance Spectroscopy, DEIS). Technika ta zakłada, że badany system jest pseudostacjonarny jeśli czas pomiaru jest odpowiednio krótki. Czas potrzebny na otrzymanie pojedynczego spektrum zależy od długości okna...
-
Impedance monitoring of fuel cell stacks
Publication -
Local impedance spectra of organic coatings
Publication -
Local impedance spectra of organic coatings
PublicationPublikacja przedstawia nowe podejście do lokalnych spektroskopowych pomiarów impedancyjnych powłok organicznych, oparte o mikroskop sił atomowych pracujący w trybie kontaktowym. Pomiędzy nieporuszającą się igłę mikroskopu i podłoże metalowe pokryte powłoką epoksydową przyłożono serię sinusoidalnych napięciowych sygnałów pobudzenia w zadanym zakresie częstotliwości. W ten sposób zarejestrowano lokalne widma w trybie "frequency by...
-
Platform Supporting the Esophageal Impedance Analysis
PublicationThe esophageal pH-impedance examination is one of the most popular diagnostic methods for identifying the upper gastrointestinal tract’s diseases. Inconclusive test evaluation criteria makes it difficult to state the definite diagnosis. In this paper, the computer platform supporting the research and teaching process in the area of pH-impedance analysis is presented. Users, having a variety of mathematical and statistical methods...
-
A Comprehensive Analysis of Impedance of the Electrochemical Cell
PublicationA comprehensive impedance characteristics of two electrodes electrochemical cell has been pre sented. In this method a multisinusoidal current excitation signal is used. The change of potential of both the electrodes are all registered as a function of time. The proposed method gives the possibility of determining the impedance of both electrodes individually as well as the impedance of a twoelectrode system. Additional application...
-
Characterization of Bi6Fe2Ti3O18 Ceramics with Impedance Spectroscopy
PublicationIn the present research the tool of impedance spectroscopy was utilized to characterize dielectric behavior of Aurivillius-type ceramics of Bi6Fe2Ti3O18 composition fabricated by hot pressing method from the stoichiometric mixture of oxides Bi2O3, TiO2 and Fe2O3. Impedance spectroscopy was applied to characterize dielectric response of bulk, grain boundary, and material/electrode interfaces of the fabricated polycrystalline ceramic...
-
Impedance monitoring of fuel cell stacks
PublicationThis paper presents an innovative, electrochemical impedance method for monitoring of electrochemical behaviour of a multi-cell, direct methanol fuel cell (DMFC) device. This method not only provides classical voltage changes at successive cells but also allows their detailed impedance behaviour to be presented. Impedance characteristics of individual cells within a fuel cell stack (depending on actual operating conditions) are...
-
Impedance spectroscopy of single chamber SOFC.
PublicationMechanizm działania jednokomorowego ogniwa paliwowego SOFC, które pracuje w mieszaninie powietrza i paliwa, nie jest do końca zbadany. W tej pracy przedstawiono wyniki badań ogniwa paliwowego zbudowanego z tlenku cyrkonu stabilizowanego itrem jako nośnego elektrolitu, cermetu z tlenku niklu jako anody i perovskitu LSCF jako katody w temperaturach 500-700C z użyciem mieszaniny propanu i powietrza. Wykorzystując spektroskopię impedancyjną...
-
Impedance spectroscopy of undoped cerium oxide.
PublicationW pracy przedstawiono badania impedancyjne niedomieszkowanego tlenku ceru. Wyniki wskazują na występowanie zjawiska dyfuzji,???? które nie są (.. jest.?)związane z odpowiedzią elektrodową. Rozważania teoretyczne dopuszczają obserwowanie impedancji Warburga, która reprezentuje zjawisko dyfuzji w przewodnikach mieszanych, jednakże niewiele informacji na ten temat można znaleźć w literaturze. W związku z tym szczegółowe badania zródła...
-
Use of porous glass and silica gel as support media of a surface compound for generation of analytes in gaseous standard mixtures. New method for the determination of the amount of analyte generated
Publication -
The new analyzer based on single pellistor sensor for determination of hydrogen and methane in air
PublicationW artykule przedstawiono rezultaty niedawnych badań nad konstrukcją prostego i selektywnego analizatora do monitoringu stężenia gazów wybuchowych w powietrzu. Opisano konstrukcję takiego urządzenia i wyniki prób laboratoryjnych dla gazowych mieszanin wzorcowych.
-
Impedance of cation-coupled electron transfer reaction: teoretical description of one pathway process
PublicationPrzyjęto możliwość występowanie dwóch wzajemnie sprzężonych reakcji. Opisana została impedancja sprzężonej reakcji przeniesienia elektronu z kationem. Wyznaczony został również model elektrycznego schematu zastępczego. Całkowita impedancja Faradayowska jest sumą impedancji przeniesienia elektronu i impedancji przeniesienia kationu. Przykłady pomiaru impedancyjnego w warunkach potencjostatycznych i potencjodynamicznych zostały omówione....
-
Mesoscopic impedance analysis of solid materials’ surface
Publication -
Instantaneous electrochemical impedance spectroscopy of electrode reactions
Publication -
The time dependence of pit creation impedance spectra
Publication -
Continuous‐Frequency Method of Measurement of Electrode Impedance
Publication -
Mesoscopic impedance analysis of solid materials surface
PublicationSeveral techniques have been developed in order to characterize electrical properties of surfaces in micrometer/nanometer scale. Obtaining of the spatial distribution of sample resistance, capacitance or potential requires separate measurements performed in different scanning modes. On the other hand, analysis of the frequency response of investigated system enables determination of several physical quantities in single measurement...
-
Using A Particular Sampling Method for Impedance Measurement
PublicationThe paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was...
-
Selection of excitation signals for high-impedance spectroscopy
PublicationA method of fast impedance spectroscopy of technical objects with high impedance (|Zx| > 1 GOhm) is evaluated in this paper. An object is excited with a signal generated by a digital-to-analog converter (DAC) located on the U2531A DAQ module. Response signals proportional to current flowing through and voltage across the measured object are sampled by analog-to-digital converters (ADC) in the DAQ module. The object impedance spectrum...
-
On the characteristic impedance definition in microstrip and coplanar lines
PublicationW niniejszej pracy rozważono definicję impedancji charakterystycznej dla bezstratnych linii mikropaskowych i koplanarnych. Wykazano, że ze względu na znaczne wartości prądu przesunięcia związanego z podłużną składową pola elektrycznego, definicja impedancji staje się niejednoznaczna. W rezultacie może to przyczyniać się do istotnych błędów powstających już na etapie projektowania układów. Pokazano, iż efekt ten jest szczególnie...
-
Impedance evaluation of coatings from biobased material
PublicationThe authors propose a modification of sodium caseinate edible coating for foodstuff protection. The aim was to improve the film’s barrier properties. It was achieved by the addition of propolis, which is a natural, environmentally friendly product known from its intrinsic sealing action. In the next step, propolis-admixed sodium caseinate films were exposed to elevated temperature for 10 min. This approach was meant to improve...
-
Impulse Impedance Measurements of Lightning Protection Earthings
PublicationLightning protection earthing systems should be tested at currents with time parameters similar to those of lightnings. A method and definition of a measured value of impulse impedance are introduced. The impulse impedance was determined by a quotient of voltage drop on the tested earthing to a value of current in measure circuit. The usefulness of the impulse method for lightning protection evaluation is tested on radio base stations...
-
Continuous frequency method of measurement of electrode impedance.
PublicationPrzedstawione zostały matematyczne podstawy nowej metody pomiaru impedancji elektrodowej. Metoda wykorzystuje sygnał pobudzenia którego częstotliwość zmienia się liniowo w czasie. Amplituda sinusoidalnego niestacjonarnego pobudzenia jest stała. Zapis i analiza sygnału pobudzenia i odpowiedzi pozwalana wyznaczenie ciągłego widma impedancyjnego. Jednoczesna analiza czasowo częstotliwościowa wykonano została przy użyciu transformacji...
-
Impedance measurements of coating properties on bridge structures
PublicationPomiary impedancyjne pozwalają na prostą ocenę właściwości ochronnych powłok ochronnych i wykładzin. Pomiary stosuje się w celu porównania powłok, monitorowania ich właściwości i oceny mechanizmu działania. Metodyka jest z powodzeniem stosowana w pomiarach laboratoryjnych. Pomiary terenowe są bardziej skomplikowane ponieważ wymagają w pełni kontrolowanych komputerowo przyrządów, kontroli warunków pogodowych oraz wielu innych parametrów...
-
Instantaneous electrochemical impedance spectroscopy of electrode reactions.
PublicationUstalona została ciągła transformata STFT sinusoidalnego sygnału pobudzeniai odpowiedzi prądowej dla pierwszorzędowej reakcji elektrodowej. Impedancja elektrodowa wyznaczona została w łącznej dziedzinie czasowo-częstotliwościowej. Wykonano pomiary reakcji redukcji Cd(II) na kapiącej elektrodzie rtęciowej w funkcji czasu. Zaprezentowano możliwość wyznaczania chwilowych widm impedancyjnych. Opisano czasowe charakterystyki rezystancji...
-
The time dependence of pit creation impedance spectra.
PublicationPrzeprowadzono pomiar impedancyjny w warunkach chronoamperometrycznych uzyskując zmiany impedancji układu w czasie. Na ich podstawie wyznaczono zmiany rezystancji przeniesienia ładunku i pojemności w czasie opisujące inicjację i rozwój korozji wżerowej. Potwierdzono użyteczność dynamicznej elektrochemicznej spektroskopii impedancyjnej w badaniu korozji wżerowej.
-
A metrological analysis of the input circuit of an impedance meter.
PublicationW pracy przeprowadzono analizę obwodu wejściowego miernika impedancji W analizie obwodu wejściowego, uwzględniono najważniejsze czynniki wpływające na sygnały na jego wejściu: parametry zmiennoprądowe zastosowanych wzmacniaczy, rezystancję zakresową przetwornika prąd-napięcie, pojemności montażowe. Przeprowadzono symulację sygnałów wydzielanych w obwodzie dla różnych wartości pojemności pasożytniczych, następnie dokonano badań...