Filters
total: 1232
-
Catalog
- Publications 755 available results
- Conferences 1 available results
- People 6 available results
- Inventions 2 available results
- Projects 1 available results
- Laboratories 1 available results
- Research Equipment 1 available results
- e-Learning Courses 7 available results
- Open Research Data 458 available results
displaying 1000 best results Help
Search results for: MP3 ENCODER
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 290 mA. Sample 82, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 290 mA. Sample 82. Experiment run #1.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 28 mA. Sample 115.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 28 mA. Sample 115.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 180 mA. Sample 103.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 180 mA. Sample 103. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 360 mA. Sample 103.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 360 mA. Sample 103. The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 256 mA. Sample 91.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 256 mA. Sample 91.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 260 mA. Sample 82.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 260 mA. Sample 82.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to ensure uniform surface...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 290 mA. Sample 82, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 290 mA. Sample 82, experiment run #2.The images were taken with thermographic camera VigoCAM V50. The sample was covered by black graphite paint to...
-
Symulacja pracy komunalnego ujęcia infiltracyjnego w warunkach dopuszczalnej eksploatacji = Municipal infiltration intake work simulation under the admissible exploatation
PublicationW dolinie rzeki Brdy realizowane jest, jako jedno z pierwszych w Polsce, sztuczne ujęcie infiltracyjne. Dopuszczalna eksploatacja ujęcia wynosi 100 000 m3/24 godz. W pracy przedstawiono wyniki obliczeń modelowych pracy ujecia infiltracyjnego przy wykorzystaniu programu Modflow. W wyniku obliczeń otrzymano rzędne swobodnej powierzchni wytworzonej warstwy wodonośnej oraz opracowano bilans wodny krążenia wód podziemnych w rejonie...
-
Static and dynamic properties of light PU foam for building the shallow river barges
PublicationPrzedstawiono wyniki badań wytrzymałości statycznej na rozciąganie, ściskanie i ścinanie oraz zmęczeniowej przy obciążeniach ściskających jednostronnie tętniących pian poliuretanowych o gęstości 53 i 62 kg/m3, mierzonych w kierunku podłużnym i prostopadłym do kierunku wzrostu piany w procesie jej otrzymywania. Stwierdzono wyraźną anizotropię własności mechanicznych piany. Obserwowano znacznie silniejsze zniszczenie zmęczeniowe...
-
Badania betonów o przyspieszonym twardnieniu
PublicationBadania wykazały, że możliwe jest uzyskanie tak wysokich wytrzymałości wczesnych betonów, że całkowicie zbędna staje się ich obróbka termiczna. Stosując odpowiedni cement klasy 42,5R i prawidłowo dobrana mieszankę upłynniającą można uzyskać już po 12 godz. wytrzymałość betonu około 35MPaa przy klasie cementu 52,5R nawet około 50MPa i to przy ilości cementu nie przekraczającej 400 kg/m3 betonu.
-
Speech Intelligibility Measurements in Auditorium
PublicationSpeech intelligibility was measured in Auditorium Novum on Technical University of Gdansk (seating capacity 408, volume 3300 m3). Articulation tests were conducted; STI and Early Decay Time EDT coefficients were measured. Negative noise contribution to speech intelligibility was taken into account. Subjective measurements and objective tests reveal high speech intelligibility at most seats in auditorium. Correlation was found between...
-
Conley-Morse graphs for a non-linear Leslie population model with 2 varying parameters
Open Research DataThis dataset contains selected results of rigorous numerical computations conducted in the framework of the research described in the paper "A database schema for the analysis of global dynamics of multiparameter systems" by Z. Arai, W. Kalies, H. Kokubu, K. Mischaikow, H. Oka, P. Pilarczyk, published in SIAM Journal on Applied Dynamical Systems (SIADS),...
-
Conley-Morse graphs for a non-linear Leslie population model with 3 varying parameters
Open Research DataThis dataset contains selected results of rigorous numerical computations conducted in the framework of the research described in the paper "A database schema for the analysis of global dynamics of multiparameter systems" by Z. Arai, W. Kalies, H. Kokubu, K. Mischaikow, H. Oka, P. Pilarczyk, published in SIAM Journal on Applied Dynamical Systems (SIADS),...
-
Influence of the Addition of Recycled Aggregates and Polymer Fibers on the Properties of Pervious Concrete
PublicationThe aim of the study was to check the possibility of reusing aggregate from recycled concrete waste and rubber granules from car tires as partial substitution of natural aggregate. The main objective was to investigate the effects of recycled waste aggregate modified with polymer fibers on the compressive and flexural strength, modulus of elasticity and permeability of pervious concrete. Fibers with a multifilament structure and...
-
Hydration of simple amides. FTIR spectra of HDO and theoretical studies
PublicationZastosowano metodę ważonych widm różnicowych do opisu hydratacji amidów w roztworach wodnych: formamidu, N-metyloformamidu, N,N-dimetyloformaidu, acetamidu, N-metyloacetamidu, N,N-dimetyloacetamidu. Narzędziem wspomagającym interpretację wyników eksperymentalnych są struktury agregatów solwatacyjnych wokół cząsteczki substancji rozpuszczonej uzyskane na podstawie obliczeń teoretycznych metodą ab initio z korelacją elektronową...
-
The influence of oscillatory low pressure on bacteria number in groundwater supplied to distribution system
PublicationPrzedstawiono wyniki wstępnych badań laboratoryjnych nad wpływem stałego podwyższonego ciśnienia oraz częstych i gwałtownych jego zmian na liczbę bakterii w wodzie podziemnej. Określono zmiany liczby bakterii heterotroficznych (na agarze R2A) oraz całkowitej liczby bakterii (DAPI) w wodzie podziemnej (w temperaturze 20 st.C w okresie 96 h) poddawanej ciągłemu ciśnieniu 0,6 MPa i porównano z uzyskanymi w wodzie poddanej gwałtownym...
-
Hydrogen assisted cracking of high-strength weldable steels in sea-water.
PublicationOceniono niszczenie wodorowe stalio wysokiej wytrzymałości i ich złączy spawanych przy różnych rodzajach obciążenia w wodzie morskiej. Prowadzono próby rozcią gania z małą prędkością odkształcenia i zmęczenia niskocyklowego w wodzie morskiej przy polaryzacji katodowej. Badano dwa gatunki stali o minimalnej granicy plastyczności 690 MPa, oraz jej złącza spawane automatycznie łukiem krytym i ręcznie łukowo elektrodą otuloną. Dla...
-
Hydrogen production from ethanol In nitrogen microwave plasma At atmospheric pressure
PublicationHydrogen seems to be one of the most promising alternative energy sources. It is a renewable fuel as it could be produced from e.g. waste or bio-ethanol. Furthermore hydrogen is compatible with fuel cells and is environmentally clean. In contrast to conventional methods of hydrogen production such as water electrolysis or coal gasification we propose a method based on atmospheric pressure microwave plasma. In this paper we present...
-
Thermophysical study of the binary mixtures of triethyl phosphate with N-methylformamide, N,N-dimethylformamide and N,N-dimethylacetamide – Experimental and theoretical approach
PublicationDensities at (293.15, 298.15, 303.15 and 308.15) K, and viscosities and ultrasonic velocities at 298.15 K of binary liquid mixtures of triethyl phosphate with N-methylformamide, N,N-dimethylformamide and N,N-dimethylacetamide have been measured over the entire range of composition at p = 0.1 MPa. From the experimental data, values of excess molar volume, excess isentropic compressibility, viscosity deviation and excess Gibbs energy...
-
Processing, Performance Properties, and Storage Stability of Ground Tire Rubber Modified by Dicumyl Peroxide and Ethylene-Vinyl Acetate Copolymers
PublicationIn this paper, ground tire rubber was modified with dicumyl peroxide and a variable content (in the range of 0–15 phr) of ethylene-vinyl acetate copolymers characterized by different vinyl acetate contents (in the range of 18–39 wt.%). Modification of ground tire rubber was performed via an auto-thermal extrusion process in which heat was generated during internal shearing of the material inside the extruder barrel. The processing,...
-
Pressure-induced flow processing behind the superior mechanical properties and heat-resistance performance of poly(butylene succinate)
PublicationWe propose a pressure-induced flow (PIF) processing method for the simultaneous enhancement of strength, toughness, and heat resistance of biodegradable poly(butylene succinate) (PBS). The pressure and temperature were systematically adjusted to optimize the tensile strength of PBS. Under the optimized processing conditions, the structured PBS was characterized by relatively high strength of 89.5 MPa, toughness of 21.4 kJ·m−2 ,...
-
Cyclic behavior of FeCoCrNiMn high entropy alloy coatings produced through cold spray
PublicationeCoCrNiMn high entropy alloy powders were employed to produce coatings on carbon steel through high pressure cold spray (at 1100 °C and 7 MPa in temperature and pressure respectively). X-ray diffraction of the sprayed material revealed a dense coating with the retention of the original crystallographic structure. Once splatted, particles revealed high flattening ratio with consequent excellent adhesion of the coating to the substrate....
-
Surface engineering of graphene oxide membranes for selective separation of perfluorooctanoic acids
PublicationPerfluoroalkyl compounds (PFCs) are environmental toxicants and their widespread detection and accumulation in the environment can be detrimental to the ecosystem. In this study, surface charge of GO membranes was engineered to enhance selectivity of graphene oxide (GO) membranes and for the removal of perfluorooctanoic acid (PFOA ∼400 Da) in real concentration ranges in wastewater streams. The structure and physicochemical properties...
-
Changes on the Surface of the SiO2/C Composite, Leading to the Formation of Conductive Carbon Structures with Complex Nature of DC Conductivity
PublicationSol–gel layers have been the subject of many studies in recent decades. However, very little information exists about layers in which carbon structures are developed in situ. Using the spin-coating method, we obtained thin iron-doped SiO2/C composite films. The results of Raman spectroscopy showed that our samples consisted of graphitic forms and polymers. The latter’s contribution decreases with rising temperature. FTIR and EDS...
-
Preparation and Properties of Thermoplastic Polyurethane Composites Filled with Powdered Buckwheat Husks
PublicationBio-based fillers for the polymer composites are still interesting from the scientific and industrial point of view, due to their low cost and renewable nature. In this work partially green composites were obtained by the mixing of thermoplastic poly(ester-urethane) with the unmodified and modified (by acetylation) grinded buckwheat husks. Obtained biocomposites were characterized in the terms of their chemical structure (FTIR),...
-
Recent Progress on Hydrogen Storage and Production Using Chemical Hydrogen Carriers
PublicationDepleting fossil fuel resources and anthropogenic climate changes are the reasons for the intensive development of new, sustainable technologies based on renewable energy sources. One of the most promising strategies is the utilization of hydrogen as an energy vector. However, the limiting issue for large-scale commercialization of hydrogen technologies is a safe, efficient, and economical method of gas storage. In industrial practice,...
-
Badania tensometryczne płaszcza zbiornika z imperfekcjami kształtu.
PublicationW referacie przedstawiono wykorzystanie tensometrycznej metody pomiaru odkształceń do oceny rozkładu naprężeń powierzchniowych w konstrukcji rzeczywistego obiektu. Obiektem poddanym badaniom był stalowy zbiornik magazynowy, o osi pionowej, z dachem pływającym, o pojemności V=12000 m3. Badany zbiornik charakteryzował się znacznymi imperfekcjami geometrycznymi walcowej powłoki tworzącej płaszcza zbiornika. Celem realizacji badań...
-
Design of septic tanks placed on cohesive soils
PublicationThe paper presents a short review of literature with regard to design and erection of the reinforced concrete and concrete tanks. The authors investigated the underground septic tank with of 10 m3 capacity placed on cohesive soils. The authors compared the values of internal forces for soils in drained and undrained conditions with different geotechnical parameters: loamy sand of liquidity index IL = 0.1 and IL = 0.7 and clay with...
-
Phylogenetic analysis of Oncidieae subtribe - ITS1-5,8S-ITS2
Open Research DataThe dataset contains alignment and consensus matrix files, and results of phylogenetic analysis of ITS1- 5,8S-ITS2 region from 186 orchid species considered to belong Oncidieae subtribe. Sequences were assessed from NCBI GeneBank (list of all records with identifiers in the separate file)
-
Application of recombinant antigens in serodiagnosis of swine toxoplasmosis and prevalence of Toxoplasma gondii infection among pigs in Poland
PublicationNiniejsza praca przedstawia częstość występowania toksoplazmozy w populacji świń obejmującej 1754 osobników pochodzących z różnych regionów Polski, która określona została z wykorzystaniem testu IgG ELISA opartego na antygenie natywnym pasożyta. Specyficzne przeciwciała anty-T. gondii klasy IgG zostały wykryte u 19,2% zwierząt z testowanej grupy. Ponadto w pracy oszacowano użyteczność diagnostyczną w rozpoznawaniu toksoplazmozy...
-
Występowanie azotu organicznego w ściekach oczyszczonych z oczyszczalni komunalnych
PublicationCelem pracy było zbadanie przemian azotu organicznego w komorach osadu czynnego z biologicznym usuwaniem związków biogennych. Badania wykonano w Komunalnej Oczyszczalni Ścieków „Dębogórze” w Gdyni. Obejmowały one pomiary stężenia azotu ogólnego i organicznego w ściekach oczyszczonych mechanicznie i ściekach oczyszczonych biologicznie w okresie przed i po zakończonej modernizacji bioreaktorów. Azot organiczny został podzielony na...
-
Monitoring of odors emitted from stabilized dewatered sludge subjected to aging using proton transfer reaction–mass spectrometry
PublicationOne of the potential emission sources of odorous compounds from wastewater treatment plants is sludge processing. The odorous compounds released from dewatered sludge can result in odor nuisance. This study concerns the use of flux hood chamber combined with proton transfer reaction—time of flight—mass spectrometry (PTR-MS) technique for periodical monitoring of odorous compounds emitted from aged, stabilized dewatered sludge samples...
-
Peripheral T-cell lymphoma, NOS - Male, 60 - Tissue image [5190730046652591]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Peripheral T-cell lymphoma, NOS - Male, 60 - Tissue image [5190730046657141]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Peripheral T-cell lymphoma, NOS - Male, 60 - Tissue image [5190730046651671]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Peripheral T-cell lymphoma, NOS - Male, 60 - Tissue image [5190730046653801]
Open Research DataThis is the histopathological image of LYMPH NODES tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma, NOS - Female, 60 - Tissue image [5030730017667801]
Open Research DataThis is the histopathological image of BONES, JOINTS AND ARTICULAR CARTILAGE OF LIMBS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma, NOS - Female, 60 - Tissue image [5030730017665291]
Open Research DataThis is the histopathological image of BONES, JOINTS AND ARTICULAR CARTILAGE OF LIMBS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 534 mA. Sample J53, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 534 mA. Sample J53, experiment run #2. The period of images is 30 minutes in order to observe slow temperature fluctuations.The images were taken...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 534 mA. Sample J53, run #5.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 534 mA. Sample J53, experiment run #5. The period of images is 30 minutes in order to observe slow temperature fluctuations.The images were taken...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #5.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #5. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #10.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #10. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,0 V at 420 mA. Sample 103, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,0 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #2. Voltage was increased to accelerate the ageing process.The images were taken with thermographic camera VigoCAM...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 534 mA. Sample J52.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 534 mA. Sample J52. The period of images is 30 minutes in order to observe slow temperature fluctuations. The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #9.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #9. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,3 V at 420 mA. Sample 103, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,3 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #2. Voltage was increased to accelerate the ageing process.The images were taken with thermographic camera VigoCAM...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 1281 mA. Sample J51, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 1098 mA. Sample J51, experiment run #2. The current is extremely high for this type of sample to accelerate ageing processes.The images were taken...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #6.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #6. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #12.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #12. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #4.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #4. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...