Search results for: FABRY-PÉROT INTERFEROMETER
-
Spectroscopic Optical Coherence Tomography for Thin Layer and Foil Measurements
PublicationThe main goal of this research was to assess if it is possible to evaluate the thickness of thin layers (both thin films on the surface and thin layers below the surface of the tested object) and foils using optical coherence tomography (OCT) for thickness assessment under the resolution of the standard commercially available OCT measurement system. In the proposed solution, light backscattered from the evaluated thin layer has...
-
Tailoring the optical parameters of optical fiber interferometer with dedicated boron-doped nanocrystalline diamond thin film
PublicationOptical fiber interferometer using nanocrystalline boron-doped diamond film was investigated. The diamond films were deposited on glass plates using a Microwave Plasma-Enhanced Chemical Vapour Deposition (μPE CVD) sys-tem. The growth time was 3h, with boron doping level of 10 000 ppm producing films (B-NCD-10) of thickness ~ 200 nm. The presence of boron atoms in the diamond film is evident in Raman spectrum as peaks at 1212 cm-1...
-
The silver layers in fiber-optic sensors
PublicationIn this paper a method of application of the silver layers on the surface of an optical fiber was proposed. The optical properties and surface quality of the silver layer was examined by optical microscopy. The reflection and transmission of the sample were investigated. To evaluate the silver mirror it was placed in a fiber optic Fabry-Perot interferometer and the quality of the spectra was analyzed. The commercial mirror was...
-
FIBRE-OPTIC SENSOR FOR SIMULTANEOUS MEASUREMENT OF THICKNESSAND REFRACTIVE INDEX OF LIQUID LAYERS
PublicationIn this paper, we present a fibre-optic sensor for simultaneous measurement of refractive index and thickness of liquid layers. We designed an experimental low-coherence setup with two broadband light sources and an extrinsic fibre-optic Fabry–Pérot interferometer acting as the sensing head. We examined how the refractive index of a liquid film and its thickness affect spectrum at the output of a fibre-optic interferometer. We...
-
In-situ monitoring of electropolymerization processes at boron-doped diamond electrodes by Mach-Zehnder interferometer
PublicationIn this work, the Mach-Zehnder interferometer was designed to monitor the electrochemical processes conducted at boron-doped diamond electrode surface. The diamond electrodes were synthesized via Microwave Plasma-Assisted Chemical Vapor Deposition on optical grade quartz glass. The achieved transmittance in working are of diamond electrodes reached 55 %. A cage system-based Mach-Zehnder interferometer was used which allowed the...
-
Fiber-optic temperature sensor using low-coherence interferometry
Publication -
Measuring the density of DNA films using ultraviolet-visible interferometry
PublicationIn order to determine a proper value for the density of dry DNA films we have used a method based upon the measurement of interference effects in transmission spectra of thin DNA layers. Our results show that the methodology is effective and the density of DNA in this state, 1.407 g/cm3, is much lower than the commonly used 1.7 g/cm3. Obtaining accurate values for the DNA film density will allow the optical constants for DNA to...
-
Laser beam angular stabilization system based on a compact interferometer and a precise double-wedge deflector
Publication -
White-light interferometric temperature sensor for biomedical diagnostic.
PublicationW artykule opisano opracowany model miniaturowego, światłowodowego czujnika temperatury z interferometrem Fabry-Perot wykorzystującego interferencję światła białego przeznaczonego do zastosowań biomedycznych. Analizowano czujnik wykonany ze światłowodu wielomodowego o skokowym profilu współczynnika załamania oraz ze światłowodu monomodowego. Zasadniczym celem był dobór parametrów mający na celu uzyskania maksymalnej widzialności...
-
Doped Nanocrystalline Diamond Films as Reflective Layers for Fiber-Optic Sensors of Refractive Index of Liquids
PublicationThis paper reports the application of doped nanocrystalline diamond (NCD) films—nitrogen-doped NCD and boron-doped NCD—as reflective surfaces in an interferometric sensor of refractive index dedicated to the measurements of liquids. The sensor is constructed as a Fabry–Pérot interferometer, working in the reflective mode. The diamond films were deposited on silicon substrates by a microwave plasma enhanced chemical vapor deposition...
-
Measurement of complex refractive index of human blood by low-coherence interferometry
PublicationIn this article, the usefulness of the optical technique for measurements of blood complex refractive index has been examined. Measurement of optical properties of human blood is difficult to perform because of its nonuniform nature. However, results of my investigation have shown the usefulness of low-coherencei nterferometry for measurement complex refractive index of human blood. Furthermore, mathematical analysis of spectrum...
-
Modeling of selected transducer designs for optical pressure sensors using polarization interferometry
PublicationW artykule przedstawiono wyniki modelowania metodą Elementów Skończonych wybranych konstrukcji membran do zastosowań w interferometrycznych czujnikach ciśnienia. Omówiono zależność prametrów membran od kształtu membrany, jej wymiarów i zastosowanego materiału. Zakres odkształcen badanych membran jest niezbyt duży, co może pogarszać dokładność pomiaru czujników ciśnienia, w których będą one stosowane Omówiono kierunki dalszych...
-
Miniaturowy czujnik temperatury z interferometrem światła białego dla zastosowań biomedycznych.
PublicationW artykule opisano model miniaturowego, światłowodowego czujnika temperatury z interferometrem Fabry Perota wykorzystującego interferencję światła białego, dla zastosowań biomedycznych.
-
Coda wave interferometry in monitoring the fracture process of concrete beams under bending test
PublicationEarly detection of damage is necessary for the safe and reliable use of civil engineering structures made of concrete. Recently, the identification of micro-cracks in concrete has become an area of growing interest, especially using wave-based techniques. In this paper, a non-destructive testing approach for the characterization of the fracture process was presented. Experimental tests were made on concrete beams subjected to mechanical...
-
Marvels & Tales-Journal of Fairy-Tale Studies
Journals -
Combined Long-Period Fiber Grating and Microcavity In-Line Mach–Zehnder Interferometer for Refractive Index Measurements with Limited Cross-Sensitivity
PublicationThis work discusses sensing properties of a long-period grating (LPG) and microcavity in-line Mach–Zehnder interferometer (µIMZI) when both are induced in the same single-mode optical fiber. LPGs were either etched or nanocoated with aluminum oxide (Al2O3) to increase its refractive index (RI) sensitivity up to ≈2000 and 9000 nm/RIU, respectively. The µIMZI was machined using a femtosecond laser as a cylindrical cavity (d = 60...
-
Implementation of SiN thin film in fiber-optic sensor working in telecommunication range of wavelengths
PublicationMirrors are used in optical sensors and measurement setups. This creates a demand for mirrors made of new materials and having various properties tailored to specific applications. In this work, we propose silicon covered with a thin silicon nitride layer as a mirror for near-infrared measurements. SiN layer was deposited on a standard silicon wafer with a Low-Pressure Chemical Vapor Deposition furnace. Then, the created layer...
-
Smart Growth – Is It a Fairy Tale or the Best Initiative for Polish Cities and Their Functional Regions?
Publication.
-
Interferometric Sensor of Wavelength Detuning Using a Liquid Crystalline Polymer Waveplate
PublicationOperation of a polarization interferometer for measurement of the wavelength changes of a tunable semiconductor laser was investigated. A lambda/8 waveplate made from liquid crystalline polymer is placed in one of interferometers’ arms in order to generate two output signals in quadrature. Wavelength was measured with resolution of 2 pm in the wavelength range 628–635 nm. Drift of the interferometer, measured in the period of 500...
-
Incorporation of nitrogen in diamond films - A new way of tuning parameters for optical passive elements
PublicationThis paper investigates the impact of nitrogen incorporation in diamond films for the construction of an interferometric sensor to measure displacement. Diamond films with different nitrogen levels (0–5%) were deposited on silicon substrates by microwave plasma enhanced chemical vapor deposition. The structural characteristics of these samples are characterized using scanning electron microscopy (SEM), atomic force microscopy...
-
Long-Period Gratings and Microcavity In-Line Mach Zehnder Interferometers as Highly Sensitive Optical Fiber Platforms for Bacteria Sensing
PublicationSelected optical fiber sensors offer extraordinary sensitivity to changes in external refractive (RI), which make them promising for label-free biosensing. In this work the most sensitive ones, namely long-period gratings working at (DTP-LPG) and micro-cavity in-line Mach-Zehnder interferometers (µIMZI) are discussed for application in bacteria sensing. We describe their working principles and RI sensitivity when operating in water...
-
Combined analysis of whole human blood parameters by Raman spectroscopy and spectral-domain low-coherence interferometry
PublicationIn this article the simultaneous investigation of blood parameters by complementary optical methods, Raman spectroscopy and spectral-domain low-coherence interferometry, is presented. Thus, the mutual relationship between chemical and physical properties may be investigated, because low-coherence interferometry measures optical properties of the investigated object, while Raman spectroscopy gives information about its molecular...
-
Laser reflectance interferometry system with a 405 nm laser diode for in-situ measurement of CVD diamond thickness
PublicationIn situ monitoring of the thickness of thin diamond films during technological processes is important because it allows better control of deposition time and deeper understanding of deposition kinetics. One of the widely used techniques is laser reflectance interferometry (LRI) which enables non-contact measurement during CVD deposition. The authors have built a novel LRI system with a 405 nm laser diode which achieves better...
-
Diamond Structures for Tuning of the Finesse Coefficient of Photonic Devices
PublicationFinesse coefficient is one of the most important parameters describing the properties of a resonant cavity. In this research, a mathematical investigation of the application of diamond structures in a fiber-optic Fabry–Perot measurement head to assess their impact on the finesse coefficient is proposed. We present modeled transmission functions of cavities utilizing a nitrogen-doped diamond, a boron-doped diamond, nanocrystalline...
-
Application of sol-gel-developed integrated optic devices to biochemical fiber optic sensors based on polarimetric interferometry.
PublicationW pracy omówiono zasady działania sensorów optycznych wykonanych w technologii optyki zintegrowanej i wykorzystujących interferometrię polaryzacyjną. Zaproponowano konstrukcję jednorazowego przetwornika pomiarowego, wykonanego w technologii sol-żel z materiałów hybrydowych, która umożliwia wykorzystanie nieodwracalnych reakcji chemicznych do pomiarów w medycynie, chemii i ochronie środowiska. Omówiono technologię syntezy materiałów...
-
Optimization of white light interferometric temperature sensor. Workshop on Atomic and Molecular Physics.
PublicationW artykule przedstawiono metodę optymalizacji parametrów niskokoherencyjnego interferometrycznego czujnika temperatury wykorzystującego miniaturowy interferometr Farby Perota, pracujący w modzie odbiciowym.
-
Nanocrystalline diamond sheets as protective coatings for fiber-optic measurement head
PublicationFiber-optic sensors find numerous applications in science and industry, but their full potential is limited because of the risk of damaging the measurement head, in particular, due to the vulnerability of unprotected tips of the fiber to mechanical damage and aggressive chemical agents. In this paper, we report the first use of a new nanocrystalline diamond structure in a fiber-optic measurement head as a protective coating of...
-
Computer support of analysis optical spectra measurements
PublicationVerification of measurement errors has a big impact on assessment of accuracy of conducted measurements and obtained results. In many cases computer simulation results are compared with measurement results in order to evaluate measurement errors. The purpose of our research was to check the accuracy of measurements made with Fabry-Perot interferometer working in the transmission mode. In measurement setup, a 1310 nm superluminescent...
-
Computer Support of Analysis of Optical Spectra Measurements
PublicationThe verification of measurement errors has a big impact on the assessment of the accuracy of conducted measurements and obtained results. In many cases, computer simulation results are compared with measurement results in order to evaluate measurement errors. The purpose of our research was to check the accuracy of measurements made with a Fabry–Perot interferometer working in the transmission mode. In the measurement setup, a...
-
Crack monitoring in concrete beams under bending using ultrasonic waves and coda wave interferometry: the effect of excitation frequency on coda
PublicationConcrete is one of the most widely used construction materials in the world. In recent years, various non-destructive testing (NDT) and structural health monitoring (SHM) techniques have been investigated to improve the safety and control of the current condition of concrete structures. This study focuses on micro-crack monitoring in concrete beams. The experimental analysis was carried out on concrete elements subjected to three-point...
-
Distance measurement by the low coherent interferometer
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1560 nm, an optical spectrum analyzer and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Application of fiber optic sensors using Machine Learning algorithms for temperature measurement of lithium-ion batteries
PublicationOptical fiber sensorsusing low-coherence interferometry require processing ofthe output spectrum or interferogramto quickly and accurately determine the instantaneous value of the measured quantity, such as temperature.Methods based on machine learning are a good candidate for this application. The application of four such methods in an optical fiber temperature sensoris demonstrated.Using aZnO-coated...
-
Monitoring the fracture process of concrete during splitting using integrated ultrasonic coda wave interferometry, digital image correlation and X-ray micro-computed tomography
PublicationThe paper deals with the continuous-time monitoring of mechanical degradation in concrete cubes under splitting. A series of experiments performed with integrated coda wave interferometry (CWI) and digital image correlation (DIC), supported with X-ray micro-computed tomography (micro-CT) is reported. DIC and micro-CT techniques were used to characterize the fracture process in detail. CWI method was proved to be effective in the...
-
Global Complex Roots and Poles Finding Algorithm in C × R Domain
PublicationAn algorithm to find the roots and poles of a complex function depending on two arguments (one complex and one real) is proposed. Such problems are common in many fields of science for instance in electromagnetism, acoustics, stability analyses, spectroscopy, optics, and elementary particle physics. The proposed technique belongs to the class of global algorithms, gives a full picture of solutions in a fixed region ⊂ C × R and...
-
Dependence of biological sensing on temperature based on investigation of SARS-CoV-2
Open Research DataPresented dataset is the result of an investigation of the attachment of SARS-CoV-2 specific IgG in the temepratures relevant in biology. The samples were measured during a period of 15 minutes, at 5°C, 25°C and 55°C. The measurements were performed using the microspher-based fiber-optic sensor, as an interferometer. The broadband optical light source...
-
Incorporation of nitrogen in diamond films – A new way of tuning parameters for optical passive elements
PublicationThis paper investigates the impact of nitrogen incorporation in diamond films for the construction of an interferometric sensor to measure displacement. Diamond films with different nitrogen levels (0–5%) were deposited on silicon substrates by microwave plasma enhanced chemical vapor deposition. The structural characteristics of these samples are characterized using scanning electron microscopy (SEM), atomic force microscopy (AFM), confocal...
-
Preparation and Characterization of Microsphere ZnO ALD Coating Dedicated for the Fiber-Optic Refractive Index Sensor
PublicationWe report the fabrication of a novel fiber-optic sensor device, based on the use of a microsphere conformally coated with a thin layer of zinc oxide (ZnO) by atomic layer deposition (ALD), and its use as a refractive index sensor. The microsphere was prepared on the tip of a single-mode optical fiber, on which a conformal ZnO thin film of 200 nm was deposited using an ALD process based on diethyl zinc (DEZ) and water at 100 °C....
-
Paweł Wierzba dr hab. inż.
PeopleDr Paweł Wierzba, E.E. M.Sc. E.E. received from WETI PG 1994 PhD in optoelectronics (with honours) from WETI PG 2001 Research Stays at VTT Technical Research Centre of Finland from 1997 to 2000 Finnish Academy Scholarship at VTT Technical Research Centre of Finland (12 months) 2002-3 Research interest area covers optical and optical fiber meaurement methods, technology of selected ceramic and liquid crystalline materials relevant...
-
Distance measurement by the low coherent interferometer with NND layer (the source wavelegth 1310 nm)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 0 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 40 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 30 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 200 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 80 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 170 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 20 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 140 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 130 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 50 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...