Filters
total: 3533
-
Catalog
- Publications 1674 available results
- Journals 128 available results
- Conferences 1 available results
- Publishing Houses 1 available results
- People 57 available results
- Inventions 14 available results
- Projects 10 available results
- Laboratories 2 available results
- Research Teams 1 available results
- Research Equipment 9 available results
- e-Learning Courses 215 available results
- Events 13 available results
- Open Research Data 1408 available results
displaying 1000 best results Help
Search results for: EMC ODPORNOŚĆ
-
ReFlexeNN - the Wearable EMG Interface with Neural Network Based Gesture Classification
PublicationThe electromyographic activity of muscles was measured using a wireless biofeedback device. The aim of the study was to examine the possibility of creating an automatic muscle tension classifier. Several measurement series were conducted and the participant performed simple physical exercises - forcing the muscle to increase its activity accordingly to the selected scale. A small wireless device was attached to the electrodes placed...
-
EMI attenuation in a DC-DC buck converter using GaN HEMT
PublicationA dc-dc buck converter using gallium nitride (GaN) high electron mobility transistors (HEMT) is experimentally investigated at the discontinuous current mode (DCM) and at the triangular current mode (TCM) operation. The paper objective is to specify the power conversion efficiency and attenuation of common mode (CM) and differential mode (DM) noise voltage, measured at the line impedance stabilization network (LISN) for compared...
-
EMI mitigation of GaN power inverter leg by local shielding techniques
PublicationThis paper presents local shielding techniques applied to a half-bridge inverter leg with the aim to reduce the common mode (CM) current noise at converter’s DC input. The research study is conducted for 650V Enhancement mode Gallium Nitride (GaN) power transistor switches. Main contributors of parasitic capacitances referred to the inverter-leg middle point node are identified. Then, shielding solutions are proposed to reduce...
-
Jarosław Łuszcz dr hab. inż.
People -
Wpływ filtru wyjściowego falownika na generowanie zaburzeń w przewodzie ochronnym. III Krajowe Sympozjum Kompatybilność Elektromagnetyczna w Elektrotechnice i Elektronice, EMC´03.
PublicationW artykule zamieszczono wyniki badań zaburzeń występujących w przewodzie ochronnym silnika asynchronicznego klatkowego zasilanego z sieci elektroenergetycznej przez przemiennik częstotliwości. Widma zaburzeń powodowane zmianą stanu łączników półprzewodnikowych w przemiennikach częstotliwości określono w zakresie częstotliwości 10kHz - 150kHz, 150kHz - 30MHz. Dla badanego układu zamieszczono przykładowe amplitudy harmonicznych...
-
Cavitation erosion of heterogeneous thin coatings produced by means of laser cladding
PublicationPrzedstawiono badania odporności kawitacyjnej cienkich heterogenicznych warstw nakładanych metodami laserowymi na stal 45. Wykazano dobrą przyczepność i wysoką odporność kawitacyjną wykonanych powłok.
-
Analiza indentacyjnej twardości, odporności na zarysowania i zużycia ślizgowego polimerowych materiałów z żywicy 3D DLP UV
Publication -
Zastosowanie metody emisji akustycznej i metody dynamicznej elektrochemicznej spektroskopii impedancyjnej do badania odporności korozyjnej stopów aluminium
PublicationPrzedstawiono wyniki badania stopów aluminium metodą DEIS oraz metodą emisji akustycznej. Badania przeprowadzono w roztworze buforu boranowego (pH ) domieszkowanego jonami chlorkowymi w celu zwiększenia agresywności korozyjnej. Obydwa badane stopy aluminium ulegają w tych warunkach korozji wżerowej. Stwierdzono, że pierwsze sygnały emisji akustycznej pojawiają się przy potencjałach niższych niż potencjały, przy których następuje...
-
The Development of Anammox and <em>Chloroflexi</em> Bacteria during Composting of Sewage Sludge
Publication -
BMC BIOINFORMATICS
Journals -
BMC Geriatrics
Journals -
Electrochemical cell impedance spectra at Eoc
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Fast EM-driven optimization using variable-fidelity EM models and adjoint sensitivities
PublicationA robust and computationally efficient technique for microwave design optimization is presented. Our approach exploits variable-fidelity electromagnetic (EM) simulation models and adjoint sensitivities. The low-fidelity EM model correction is realized by means of space mapping (SM). In the optimization process, the SM parameters are optimized together with the design itself, which allows us to keep the number...
-
Impact of dielectric deterioration on the conducted EMI emissions in the DC-DC boost converter
PublicationW artykule przedstawiono wpływ starzenia kondensatorów elektrolitycznych na poziom zaburzeń elektromagnetycznych generowanych przez układ podwyższający napięcie w oparciu o metody symulacyjne oraz cyfrowe przetwarzanie sygnału (filtracje Wienera). Wyniki przedstawiono w formie widm zaburzeń generowanych przez układ oraz transmitancji pomiędzy źródłem zaburzeń a zaburzeniami. (Wpływ starzenia się dielektryków na poziom zaburzeń...
-
BMC Medical Ethics
Journals -
BMC Cardiovascular Disorders
Journals -
BMC Systems Biology
Journals -
BMC EVOLUTIONARY BIOLOGY
Journals -
BMC Medical Genetics
Journals -
BMC CELL BIOLOGY
Journals -
BMC STRUCTURAL BIOLOGY
Journals -
BMC Endocrine Disorders
Journals -
BMC Family Practice
Journals -
BMC Womens Health
Journals -
BMC Medical Genomics
Journals -
BMC DEVELOPMENTAL BIOLOGY
Journals -
BMC Oral Health
Journals -
BMC Medical Education
Journals -
ESC Heart Failure
Journals -
BMC Pharmacology & Toxicology
Journals -
BMC Emergency Medicine
Journals -
BMC Clinical Pathology
Journals -
BMC Pharmacology & Toxicology
Journals -
BMC Palliative Care
Journals -
BMC MEDICAL IMAGING
Journals -
Pratique Neurologique - FMC
Journals -
BMC Primary Care
Journals -
BMC Ecology and Evolution
Journals -
BMC Genomic Data
Journals -
Makrogenerator translatorów MC²
PublicationArtykuł prezentuje stworzony przez autorów makrogenerator translatorów MC². Makrogenerator ten po otrzymaniu definicji języka staje się translatorem tego języka. Język definiuje się podając jego składnię (produkcje gramatyki zapisane w notacji BNF) oraz znaczenie poszczególnych konstrukcji składniowych tj. opis przekształceń tekstu odpowiadającego danej konstrukcji składniowej na tekst w pewnym języku bazowym (makrodefinicje)....
-
Stress corrosion cracking of Al-Zn-Mg weldments.Korozja naprężeniowa złączy spawanych stopów Al-Zn-Mg.
PublicationPraca zawiera wyniki badań odporności korozyjnej złączy spawanych Al-Zn-Mg. Zbadano wpływ składu chemicznego stopu oraz spoiwa na odporność na korozje naprężeniową w warunkach statycznych naprężeń rozciągających.
-
Obróbka wykańczająca powłok MMC w aspekcie umocnienia i zmniejszenia chropowatości powierzchni
PublicationPowłoki natryskiwane cieplnie nakładane są z uwzględnieniem naddatku na obróbkę wykańczającą. Obróbka wykańczająca powinna zapewnić nie tylko odpowiednią grubość powłok związaną z wymiarem nominalnym przedmiotu ale również uzyskanie wymaganej chropowatości i falistości powierzchni. Najczęściej w tym celu stosuje się obróbkę wiórową, rzadziej szlifowanie. Ze względu na dużą chropowatość powłok kompozytowych o osnowie metalowej...
-
The resistance investigation of the marine engine exchaust valve using the modelling chamber = Badania odporności zaworów wylotowych silnika okrętowego w komorze modelowej
PublicationWe współczesnej technice szereg części urządzeń i instalacji pracuje w długich okresach czasu i w złożonych warunkach obciążenia mechanicznego, termicznego i chemicznego. Próby wprowadzenia nowych rozwiązań technicznych muszą być poprzedzone szczegółowymi badaniami, które stwierdzą przydatność do konkretnych zastosowań. Problemem występującym w przemyśle okrętowym, a dokładniej w procesie eksploatacji silników okrętowych jest trwałość...
-
Electrochemical cell impedance spectra at Eoc+100mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc+200mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc-100mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc-200mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Mechanizm korozji stopu Al-Si nadtapianego laserowo w niskiej temperaturze.
PublicationBadano odporność na korozję elektrochemiczną stopu Al-Si metodami krzywych polaryzacji i impedancji. Ujawniono wyraźny wzrost odporności na korozję stopu nadtapianego laserowo po schłodzeniu do niskiej temperatury. Zaproponowano mechanizm korozji warstwy wierzchniej stopu.
-
Higuchi fractal dimension analysis of surface EMG signals and determination of active electrode positions
Publication -
I-V, dielectric, antibacterial, and robust EMI shielding effectiveness properties of graphene/Fe3O4
Publication