Search results for: RUTHERFORD CABLE
-
The effect of cable duct diameter on the ampacity of high-voltage power cables
PublicationThe ampacity of power cables depends, among others, on the conditions of heat dissipation from the cable to the environment. Cables are usually laid directly in the ground, but in some sections, they may be placed in ducts, which adversely affects the ampacity of the cable line. The paper presents heat transfer phenomena for cables installed in pipe-type ducts filled with air. The effect of cable duct diameter on this ampacity...
-
Application of Structural Control Systems for the Cables of Cable-Stayed Bridges: State-of-the-Art and State-of-the-Practice
PublicationStay cables are one of the key elements of cable-stayed bridges and are characterized by lightweight, low inherent damping, and high flexibility. They are continuously subjected to small-to large-amplitude vibrations due to various types of dynamic loads that may, in the long term, cause fatigue and fracture problems for the cable system, and may eventually compromise the safety of cable-stayed bridges. Thus, several countermeasures...
-
Round Table
Journals -
Numerical crash analysis of the cable barrier
PublicationSafety barriers are used to increase road safety. Their basic task is to prevent the errant vehicle from getting off the road in places which are potentially dangerous for vehicle passengers. Barriers, which are used on European roads, must fulfill the requirements of EN 1317 standards by passing appropriate crash tests. Because of their high cost, numerical simulations are increasingly used to evaluate the properties of safety...
-
Modelling of MV and HV Cable Lines
PublicationOverhead and cable lines are fundamental elements of power systems. Participation of cable lines is smaller and their percentage decreases as voltage is increased. HV cable lines are often built with the use of cables which are composed of coaxial metallic sheaths. Such cables are also often used in MV networks. The sheath may operate in different confgurations. In the case of Polish MV network the sheaths are earthed at both ends....
-
Cable-stayed bridges. Basic static schemes
PublicationThe paper presents an overview of shaping of cable-stayed bridges. Historical background, basic static sketches and overview of selected bridges are included. Selected natural solutions and interesting unrealized projects were presented. Basic ideas and most important principals are discussed. The examples and sketches were given an author's comment. Static diagrams of two pylon structures with three variants of the arrangement...
-
Conducting composites as cable anodes in cathodic protection
PublicationOpisano zasadę działania oraz podstawowe parametry charakteryzujące układ anodowy z wykorzystaniem anod kablowych w systemie ochrony katodowej podziemnych konstrukcji. W tej metodzie ochrony jako materiał anodowy wykorzystywany jest kompozyt przewodzący, którego właściwości mechaniczne umożliwiają budowę anody w formie kabla biegnącego wzdłuż trasy konstrukcji podziemnej. Wykazano, że zawartość grafitu w elektrodzie kompozytowej...
-
Dynamic Response of the Suspended on a Single Cable Footbridge
PublicationThe article presents numerical simulations, dynamic in situ load tests and a structural health monitoring (SHM) system installed in a suspended on a single cable footbridge. Numerical simulations performed prior to construction indicated the possibility of structural dynamics problems, finally confirmed in the course of dynamic test loading. In the dynamic load course the bridge deck developed vibrations displaying accelerations...
-
Heat Dissipation from the Power Cable in the Casing Pipe
PublicationThe current carrying capacity of a power cable determines its ability to carry a specific current and is related to the efficiency of dissipation of heat generated in the cable laid in a specific environment. The studies were conducted in order to determine how the characteristics of the medium around the cable affected its temperature, and thus the ability of the cable to transmit electricity. The experimentation in the lab and...
-
Shape and force control of cable structures with minimal actuators and actuation
PublicationShape adjustment and stress control can be considered as one of the effective parameters in prestressed cable structures since such structures are widely constructed nowadays due to their characteristics. The assembly errors and applied loads hugely affect the cables’ nodal positions and stress due to their delicacy. The former could disturb the shape, which affects the appearance and the function of the structure. In contrast,...
-
Modeling and Evaluation of Electric Treeing Phenomena in Polymeric Cable Insulation
PublicationThis paper investigates the treeing phenomenon in polymeric materials such as crosslinked polyethylene (XLPE) that is widely used in medium and high voltage power cables as primary insulation. The modeling of electrical tree growth in the insulation from its initiation to breakdown is significant research work that illustrates the discharge dynamics and its impact on aging process in polymeric insulation. This study utilizes pulse...
-
Shape and force control of cable structures with minimal actuators and actuation
Publication -
Conducting composites as cable anodes in cathodic protection: a literature summary
PublicationPrzedstawiono podstawową charakterystykę systemu ochrony katodowej z wykorzystaniem anod kablowych. Anody kablowe różnią się od klasycznych systemów anodowych sposobem instalacji anod. System anodowy oparty na anodach kablowych nie jest instalowany punktowo; anoda umieszczana jest w niewielkiej odległości od chronionej konstrukcji i biegnie wzdłuż trasy konstrukcji. Materiałem anodowym proponowanego rozwiązania jest elastyczny...
-
Characterization of Defects Inside the Cable Dielectric With Partial Discharge Modeling
PublicationThe continuous monitoring of power system devices is an important step toward keeping such capital assets safe. Partial discharge (PD)-based measurement tools provide a reliable and accurate condition assessment of power system insulations. It is very common that voids or cavities exist in every solid dielectric insulation medium. In this article, different voids are modeled and analyzed using an advanced finite element (FE)-based...
-
Cross-Bonding of MV Cable Lines for Energy Losses Decrease
PublicationCurrently, almost all medium voltage cable lines (MV) operate with the return wires earthed at both ends of the cable. Such a way of operation causes that during normal states of operation as well as during disturbances, e.g. short-circuits, in the return wires induce currents whose values mainly depend on the currents flowing in the phase wires. These currents in normal operating states are a source of additional energy losses...
-
AC motor feeding cable consequences on EMC performance of ASD
PublicationHigh level of conducted EMI emissions of adjustable speed drives (ASD) is one of the most difficult problems in contemporary applications. Many investigations are carried out in order to find more effective methods allowing to predict this emission at early stage of design, and therefore to predict adequate countermeasures. This paper deals with the method which allows to estimate by simulation the influence of motor feeding cable...
-
A new approach to cross-bonding in medium voltage cable lines
PublicationThe medium voltage underground cable sheaths are usually bonded and earthed in every substation on the cable route. This results in additional power losses in the sheaths. The paper presents an idea of reducing power losses caused by sheaths cross-bonding. The idea of sheaths cross-connecting only in selected MV/LV substations is given instead of a typical solution, where sheaths cross-bonding requires installing additional joints...
-
Adjustment for shape restoration and force control of cable arch stayed bridges
Publication -
Displacements of Cable-Stayed Bridge Measured With The Use of Traditional And Modern Techniques
Publication -
Theoretical analysis of the cable-stayed bridge over brda river in Bydgoszcz
PublicationThe topic of this article is the numerical analysis carried out for the cable-stayed tram (road) bridge over Brda river in Bydgoszcz. The goal of numerical studies was the verification of project assumptions and construction solutions elaborated by the autonomous team. The bridge calculations were conducted on three independent FEM models The internal forces and the elements effort under different loading schemes were examined....
-
Broadband Modeling of Motor Cable Impact on Common Mode Currents in VFD
PublicationExamination of conducted EMI generation and propagation in AC motor drives fed by frequency converter requires to consider parasitic capacitances in converters, motor windings and feeding cables to be taken into account. AC motor winding voltage transients and related common mode currents are significantly correlated with resonance effects occurring in converter's load circuits. Intensity levels of these phenomena depend...
-
Determination of the Bending Properties of Wire Rope Used in Cable Barrier Systems
PublicationThis paper presents research on the bending properties of 3 × 7 19-mm wire rope commonly used in road cable barriers. A total of 19 experimental tests were conducted. In addition, two nonlinear 3D numerical models of the wire rope using beam and solid finite elements were developed. Based on these models, four numerical simulations were carried out. The numerical results were validated against the experimental ones and a very good...
-
Pylon foundation of a cable stayed bridge at the motorway ring road of Wrocław
PublicationThe largest bridge of the motorway ring road of Wroclaw is a cable stayed bridge over the Odra river near Rędzin. Due to hydrogeological conditions of the ground it was not convenient to use standard bored piles of high length. Instead shorter piles were applied with additional improvement by cement injections at the pile toes. This decision was possible by extending ground investigation program and application of numerical modeling...
-
The influence of position of the post or its absence on the performance of the cable barrier system
PublicationRoad safety barriers are used to increase safety in potentially dangerous places on the roads. They are designed and installed on the roads to prevent any vehicle from getting outside the travelled way or from entering the opposite lane of the road. Barriers, which are used on European roads, have to undergo full scale crash tests according to the EN 1317 standards. Nowadays as a supplement to real crash tests, numerical simulations...
-
Reference FEM model for SHM system of cable-stayed bridge in Rzeszów
PublicationThe paper presents the references model for structural health monitoring system (SHM) of cable-stayed bridge recently constructed in Rzeszów over Wisłok River. The SHM system is design to provide on-line information on the structure state and facilitate its maintenance procedures. The main feature of the SHM system is permanent observation of the dynamic behavior of the bridge with focus on cable vibrations. The paper discusses...
-
Energy losses reduction in the medium voltage cable line – case study
PublicationThe paper presents an analysis of energy losses in a power cable system, which is composed of two 30 kV cable lines. This cable system is located at the seaside holiday area, so the load profile during a year is specific. Energy losses related to reactive power transmission, as well as to currents induced in the sheaths of the cables, are subject to analysis. Measurements were made in the system in order to prepare a computer model...
-
Experiment-Based Study of Heat Dissipation from the Power Cable in a Casing Pipe
PublicationThe paper deals with the important challenges in terms of electricity transmission by means of underground cable lines. The power cable’s performance is characterized by an ampacity that represents its maximum electric current-carrying capacity. The ampacity of power cables depends on their ability to diffuse the heat generated by the current flow into the environment. In the performed research, the analysis of the efficiency of...
-
Determining the Mechanical Properties of Solid Plates Obtained from the Recycling of Cable Waste
Publication -
Study of Soil Temperature and Moisture Changes in a Physical Model of an Underground Cable Line
PublicationThe ampacity of power cables is highly dependent on the thermal resistivity of the soil in which they are laid. The lower it is, the higher this ampacity. The thermal resistivity of the soil decreases as its moisture increases. Therefore, it is preferable that the soil around the cables has high moisture. Unfortunately, the heat generated in heavily loaded cables causes the migration of moisture from the surrounding soil, which...
-
Motor Cable Effect on the Converter Fed AC Motor Common Mode Current
PublicationAnaliza zaburzeń elektromagnetycznych przewodzonych w przekształtnikowych układach napędowych wymaga uwzględniania pojemności pasożytniczych występujących w przekształtniku, uzwojeniach silnika oraz kablu zasilającym silnik. Dynamiczne zmiany napięć na uzwojeniach silników zasilanych z przekształtników częstotliwości PWM oraz związane bezpośrednio z nimi składowe wspólne prądów zaburzeń przewodzonych są istotnie związane z zjawiskami...
-
The Laboratory Stand for the Evaluation of Heat Dissipation from the Power Cable in a Casing Pipe
PublicationThe current carrying capacity of a power cable determines its efficiency, which depends on its capability to dissipate heat produced inside the cable, as a result of current flow, into the surrounding. The studies were conducted to determine how the characteristics of the medium around the cable affected its temperature and, as a result, its ability to transport electricity. The experimentation in the lab and real measurements...
-
Experimental and numerical analysis of the modified TB32 crash tests of the cable barrier system
PublicationRoad restraint systems, including safety barriers, are one of the means used to improve road safety. Currently, they can be allowed to general use after passing the specific crash tests. However, it is always important and desirable to evaluate their performance under various realistic conditions, which can happen on the roads. In this study, the behaviour of the cable barrier system in impact conditions different than assumed...
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublicationPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Cerclage cable augmentation does not increase stability of the fixation of intertrochanteric fractures. A biomechanical study
PublicationBackground: Intertrochanteric fractures with a posteromedial intermediate fragment are unstable because of the loss of medial support. Additional fixation with a cerclage is used in subtrochanteric fractures, but not in intertrochanteric fractures. The aim of this biomechanical study is to evaluate whether cerclage fixation improves stability of intertrochanteric fractures. Hypothesis: Our hypothesis is that the cerclage fixation...
-
Optimum number of actuators to minimize the cross-sectional area of prestressable cable and truss structures
PublicationThis paper describes a new computational method for determining the optimum number of actuators to design the optimal and economic cross-sectional area of pin-jointed assemblies based on the conventional force method. The most active members are selected to be prestressed to redistribute stress in the whole structure, resulting in regulating the internal force of bars that face high stress. Reducing stress in critical members allows...
-
Cable stayed bridge over Vistula river in Plock. Dynamic analysis and site test
PublicationBudowę mostu przez rzekę Wisłę w Płocku ukończono w 2006 roku. Główne przęsło o długości 375 m zaprojektowano jako stalową konstrukcję podwieszoną. W celu weryfikacji konstrukcji zbudowano przestrzenny model MES. Badano zachowanie się konstrukcji mostu pod wpływem statycznego i dynamicznego obciążenia. W dalszym etapie przeprowadzono badania in - situ weryfikujące analizy numeryczne oraz założenia projektowe. Na bazie modelu MES...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublicationThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
DETERMINATION OF ADDITIONAL TENSION IN TOWED STREAMER CABLE TRIGGERED BY COLLISION WITH UNDERWATER MOVING OBJECT
PublicationThe paper deals with issues connected with the behaviour of a streamer cable towed by a survey seismic vessel when the cable undergoes a strike triggered by collision with an underwater moving object. The consequences of such collisions may be both threat to the life of marine animals or damage to underwater units and large economic losses suffered by vessel owners. The risk of such collisions has increased over the last years...
-
Design of power cable lines partially exposed to direct solar radiation – special aspects
PublicationPower cable lines are usually buried in the ground. However, in some cases, their ending sections are mounted along the supports of overhead lines. This leads to a situation where the cables are exposed to direct solar radiation and, consequentially, overheat. The paper presents the advanced computer modelling of power cables’ heating, considering their insolation as well as the effect of wind. The temperature and current-carrying...
-
Overheating of underground power cable line due to its partial exposition to solar radiation
PublicationCurrent-carrying capacity of underground power cable lines depends, among others, on thermal resistivity of the soil and cables layout: trefoil formation, flat formation with or without spacing. If conditions for heat transfer in the ground are favorable, the current-carrying capacity is relatively high. Therefore, it generates risk of the power cables overheating, if part of the cable line is located vertically in the air, to...
-
Elektroenergetyczne kable hybrydowe z włóknami światłowodowymi.
PublicationPrzedstawiono opracowane konstrukcje kabli energetycznych z wbudowanymi włóknami światłowodowymi. Zaprezentowano i omówiono przeprowadzone badania wykonanego prototypu, oceniono możliwości zastosowań w sieci telekomunikacyjnej i pomiarowej oraz dla sterowania wyposażeniem budynków inteligentnych monitoringu obiektów chronionych i świadczenia telekomunikacyjnych usług szerokopasmowych, w tym usług multimedialnych. Omówiono...
-
Modeling of Common Mode Currents Induced by Motor Cable in Converter Fed AC Motor Drives
PublicationInvestigation of conducted EMI generation in AC motor fed by pulse width modulated frequency converters requires to consider parasitic capacitances in converters, motor windings and feeding cables to be taken into account. Motor voltage transients and related common mode currents are significantly correlated with resonance effects occurring in load circuits. An analysis of frequency converter load impedance-frequency characteristics...
-
Attempt to a Video-Transmission Capability in MV Mine Cable Network Using BPL-PLC Technology
PublicationThis article presents and discusses the attempt to transmit video content using the BPL-PLC (Broadband over Power Line - Power Line Communication) technology. It includes simulation results of a specially developed digital transmitter and receiver, dedicated to a given predefined 6 kV mining power cable. The effect of two different transmission modes (2-7 MHz and 3-7.5 MHz) and two types of coupling (capacitive-inductive and induction-inductive),...
-
Incomplete Cross-Bonding in the MV Line. Experience from the Operation of MV Single Cable Lines
PublicationCable lines are one of the basic components of power systems. Medium and high voltage cables mainly comprise a metallic sheath, which is concentric to the main core conductor. There are several operating schemes of such cable lines, which differ in the place of earthing of sheaths and the possible use of the sheaths and/or conductors crossing. The sheaths cross-bonding is typically done in two places of one cable line section,...
-
Numerical studies on the influence of selected construction features and road conditions on the performance of road cable barriers
PublicationCable barriers are commonly used on Polish roads, including motorways and local roads. Their main elements are pre-stressed wire ropes, which are usually anchored at two ends in concrete blocks buried in the soil. In this work numerical studies concerning the influence of selected construction features and parameters of the vehicle motion on the performance of cable barriers were performed. Numerical simulations are a useful tool...
-
LS-DYNA simulations of the impacts of a 38-ton Heavy Goods Vehicle into a road cable barrier
PublicationNowadays, more and more attention is being paid to safety on roads and motorways. It is due to the continuous development of road and motorway network and a significant increase of the number of vehicles on roads. To meet the expectations of improving road safety in Poland, the Road Innovations Development (RID) research programme was implemented in 2016. The aim of the RID 3A - Road Safety Equipment (RoSE) project is a comprehensive...
-
Quality Evaluation of Voice Transmission Using BPL Communication System in MV Mine Cable Network
PublicationThis article presents results of a quality evaluation study, considering voice transmission in a 6 kV medium voltage cable network using the BPL (Broadband over Power Line) communication system. The tests are carried out under real mining conditions for the selected power cable without voltage, earthed at both sides. Such a method of monitoring work conditions is of great importance, especially during a disaster. Power cables are...
-
Semantic Driven Table Understanding in Born-Digital Documents
PublicationThis paper presents a new approach to table understanding, suitable for born-digital PDF documents. Advance beyond the current state of the art in table understanding is provided by the proposed reverse MVC method, which takes advantage of only partial logic structure loss (degradation) in born-digital PDF documents, as opposed to unrecoverable loss (deterioration) taking place in scan based PDF documents.
-
Zasilanie urządzeń sieci Ethernet przez kable transmisyjne
PublicationW roku 2003 komitet IEEE zatwierdził standard 802.3af (PoE) specyfikujący zasady zasilania urządzeń końcowych przez standardowe kable ethernetowe. W roku 2008 ma zostać zatwierdzona nowa wersja PoE, tzw. PoE Plus (IEEE 802.3at). W pracy omówiono zasady zasilania urządzeń proponowane w standardzie PoE, wskazano na ograniczenia wprowadzone przez IEEE 802.3af, przedstawiono podstawowe rozszerzenia proponowane w nowym rozwiązaniu PoE...
-
Design of thermal cutting table - welding technology and construction
PublicationW referacie przedstawiono pionierską pracę dyplomową stopnia inżynierskiego, wykonaną przez dwoje studentów Wydziału Mechanicznego Politechniki Gdańskiej zgodnie z systemem CDIO (Conceive, Design, Implement, Operate). W ramach pracy studenci zaprojektowali stół do cięcia termicznego metali (rysunki i obliczenia wytrzymałościowe metodą elementów skończonych), opracowali technologię spawania stołu oraz samodzielnie go wykonali. Stół...