Publications
Filters
total: 816
Catalog Publications
Year 2017
-
Analysis of Properties of an Active Linear Gesture Sensor
PublicationBasic gesture sensors can play a significant role as input units in mobile smart devices. However, they have to handle a wide variety of gestures while preserving the advantages of basic sensors. In this paper a user-determined approach to the design of a sparse optical gesture sensor is proposed. The statistical research on a study group of individuals includes the measurement of user-related parameters like the speed of a performed...
-
Automatic analysis of the aggressive behavior of laboratory animals using thermal video processing
PublicationThe bite detection is very important but difficult element of the social interaction analysis. Standard observation methods like human observer or a camcorder of visible light frequencies fail in this case. However, it is possible to discern cooler spots on the rodent's body that appear after body contact with another individual, and vanish after short time. These spots are assumed to be a saliva trace left on fur after bite. In...
-
BIG DATA SIGNIFICANCE IN REMOTE MEDICAL DIAGNOSTICS BASED ON DEEP LEARNING TECHNIQUES
PublicationIn this paper we discuss the evaluation of neural networks in accordance with medical image classification and analysis. We also summarize the existing databases with images which could be used for training deep models that can be later utilized in remote home-based health care systems. In particular, we propose methods for remote video-based estimation of patient vital signs and other health-related parameters. Additionally, potential...
-
Capacitively coupled ECG measurements - a CMRR circuit improvement
PublicationA typical galvanic-connected electrocardiogram (ECG) measurement system utilizes two signal’s electrodes and a third one in driven-right-leg (DRL) circuit for improving a common-mode rejection ratio(CMRR) of the acquisition system. In capacitive-coupled ECG similar techniques are used, however it is expected, that the utilized DRL subsystem is formed using a capacitive coupling approach, too. An improvement of the acquisition system...
-
Characteristics of La0.8Sr0.2Ga0.8Mg0.2O3-delta -supported micro-tubular solid oxide fuel cells with bi-layer and tri-layer electrolytes
PublicationIn this study, La0.8Sr0.2Ga0.8Mg0.2O3−δ (LSGM)-supported micro tubular solid oxide fuel cells (T-SOFCs) with two different configurations, one containing an LSGM–Ce0.6La0.4O2−δ (LDC) bi-layer electrolyte (Cell A) and one containing an LDC–LSGM–LDC tri-layer electrolyte (Cell B), were fabricated using extrusion and dip-coating. After optimizing the paste formulation for extrusion, the flexural strength of the dense and uniform LSGM...
-
Corrosion Study of Ceria Protective Layer Deposited by Spray Pyrolysis on Steel Interconnects
PublicationSingle fuel cells and electrolysis cells are assembled into stacks using interconnects in order to increase power and gas production capacity. The most common choice for the interconnect material is stainless steel. It has good electrical and mechanical properties and is also cost effective. One of the problems when using steel is the formation of a thermally grown oxide scale during use which has a lower electrical conductivity...
-
Deep Features Class Activation Map for Thermal Face Detection and Tracking
PublicationRecently, capabilities of many computer vision tasks have significantly improved due to advances in Convolutional Neural Networks. In our research, we demonstrate that it can be also used for face detection from low resolution thermal images, acquired with a portable camera. The physical size of the camera used in our research allows for embedding it in a wearable device or indoor remote monitoring solution for elderly and disabled...
-
Distribution of relaxation times as a method of separation and identification of complex processes measured by impedance spectroscopy
PublicationImpedance spectroscopy is one of the most commonly performed measurements to characterize electronic and electrochemical systems. Impedance spectra have limited resolution and many different processes may overlap what could be the reason of obstructions in its proper later analysis. Up to date, there are three approaches to solve this problem: examining impedance spectra itself, fitting spectra with equivalent circuits, and calculating...
-
Duże zbiory danych w zdalnej diagnostyce medycznej z wykorzystaniem technik głębokiego uczenia,
PublicationW ostatnim czasie obserwujemy tendencję globalnego starzenia się i znaczących zmian struktur demograficznych na całym świecie. Zgodnie z raportem przedstawionym przez Moody Investors Service, przewiduje się, iż do 2030 roku liczba znacząco-starzejących się krajów wzrośnie z 3 do 34. Światowy proces starzenia się społeczeństw doprowadził do wzrastających oczekiwań wobec starszych osób do pozostania niezależnymi. W związku z tym...
-
Effects of La Content on the Densification, Microstructure, and Conductivity of Doped La10−x Ge6 O26±δ Electrolytes
PublicationIn this study, the influence of La content on the characteristics of Nb-, Mo-, and W-doped LaxGe6O26±δ electrolytes was investigated through sintering study, X-ray diffraction, scanning electron microscopy, and conductivity measurement. The densification of LaxGe5.5Nb0.5O26±δ and LaxGe5.5W0.5O26±δ was retarded as the x reached 9.75, while that of LaxGe5.5Mo0.5O26±δ improved with increasing La content. The average grain size slightly...
-
Evaluation of Respiration Rate Using Thermal Imaging in Mobile Conditions
PublicationRespiratory rate is very important vital sign that should be measured and documented in many medical situations. The remote measurement of respiration rate can be especially valuable for medical screening purposes (e.g. severe acute respiratory syndrome (SARS), pandemic influenza, etc.). In this chapter we present a review of many different studies focused on the measurements and estimation of respiration rate using thermal imaging...
-
Extending touch-less interaction with smart glasses by implementing EMG module
PublicationIn this paper we propose to use temporal muscle contraction to perform certain actions. Method: The set of muscle contractions corresponding to one of three actions including “single-click”, “double-click” “click-n-hold” and “non-action” were recorded. After recording certain amount of signals, the set of five parameters was calculated. These parameters served as an input matrix for the neural network. Two-layer feedforward neural...
-
Graphene oxide, reduced graphene oxide and composite thin films NO2 sensing properties
PublicationA graphene oxide (GO), reduced graphene oxide (RGO) and poly(3,4-ethylenedioxytiophene)- reduced graphene oxide (PEDOT-RGO composite) gas sensors were successfully fabricated using an electrodeposition method. The electrodeposition was carried out in aqueous GO dispersions. In order to obtain RGO and PEDOT-RGO, the electrochemical reduction of GO and PEDOT-GO was carried out in 0.1 M KCl at constant potential of −0.85 V. The GO, RGO...
-
High performance LaNi1-xCoxO3-δ (x = 0.4 to 0.7) infiltrated oxygen electrodes for reversible solid oxide cells
PublicationOxygen electrodes prepared by infiltration of yttria stabilized zirconia backbone with Ce0.8Gd0.2O1.95 barrier layer and LaNi1-xCoxO3-δ (x=0.4 to 0.7) catalyst for application in reversible solid oxide cells have been studied. The effect of temperature and Ni:Co ratio on their phase composition, microstructure and electrochemical properties are discussed. It was shown that oxygen electrodes infiltrated with LaNi0.5Co0.5O3-δ had...
-
Improved performance of LaNi0.6Fe0.4O3 solid oxide fuel cell cathode by application of a thin interface cathode functional layer
PublicationIn this work, novel functional layers were prepared by a low temperature spray pyrolysis method on the oxygen side of the solid oxide cells. Thin layers of Ce0.8Gd0.2O2 and LaNi0.6Fe0.4O3 are prepared between the electrolyte and the porous oxygen electrode. Additionally the influence of the sprayed ceria barrier layer on the zirconia based electrolyte with the new layers is evaluated. Impedance spectroscopy results show improvement...
-
Increased inspiratory resistance affects the dynamic relationship between blood pressure changes and subarachnoid space width oscillations
PublicationBackground and objective Respiration is known to affect cerebrospinal fluid (CSF) movement. We hypothesised that increased inspiratory resistance would affect the dynamic relationship between blood pressure (BP) changes and subarachnoid space width (SAS) oscillations. Methods Experiments were performed in a group of 20 healthy volunteers undergoing controlled intermittent Mueller Manoeuvres (the key characteristic of the procedure...
-
Influence of electropolymerization temperature on corrosion, morphological and electrical properties of PPy doped with salicylate on iron
PublicationIn this work, the influence of the electropolymerization temperature on corrosion, morphological and electrical properties of polypyrrole (PPy) film is studied. Polypyrrole is electrochemically synthesized on iron in the presence of sodium salicylate. The X-ray diffraction and scanning electron microscopy are performed in order to study the structure and morphology of electrodeposited PPy. The electroactive surface area, corrosion...
-
Influence of operation temperature instability on gas sensor performance
PublicationGas sensors based on the semiconducting metal-oxides, such as SnO2, have been found to be very useful for detecting a wide range of gases. The reversible interactions of the gas with the surface of the sensing layer made of semiconducting metal-oxides are responsible for changes of sensor resistance which is usually used as a measure of sensor response. Semiconductor gas sensors are commercially available and applied in numerous...
-
La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ oxygen electrodes for solid oxide cells prepared by polymer precursor and nitrates solution infiltration into gadolinium doped ceria backbone
PublicationInfiltration is a method, which can be applied for the electrode preparation. In this paper oxygen electrode is prepared solely by the infiltration of La0.6Sr0.4Co0.2Fe0.8O3‐δ (LSCF) into Ce0.8Gd0.2O2-δ (CGO) backbone. The use a polymer precursor as an infiltrating medium, instead of an aqueous nitrate salts solution is presented. It is shown that the polymer forms the single-phase perovskite at 600 °C, contrary to the nitrates...
-
Microstructure and Electrical Properties of Fe,Cu Substituted (Co,Mn)3O4 Thin Films
PublicationIn this work, thin films (~1000 nm) of a pure MnCo2O4 spinel together with its partially substituted derivatives (MnCo1.6Cu0.2Fe0.2O4, MnCo1.6Cu0.4O4, MnCo1.6Fe0.4O4) were prepared by spray pyrolysis and were evaluated for electrical conductivity. Doping by Cu increases the electrical conductivity, whereas doping by Fe decreases the conductivity. For Cu containing samples, rapid grain growth occurs and these samples develop cracks...
-
Modeling of Cardiac Component of Subarachnoid Space Changes in Apnoea Resulting as a Function of Blood Pressure and Blood Flow Parameters - Two Mechanizm of Regulation
PublicationExperiments were performed in a group of 19 healthy, non-smoking volunteers. The experiment consisted of three apnoeas, sequentially: 30 s apnoea, 60 s apnoea and maximal, that could be done, apnoea. The breath-hold was separated for 5 minutes rest. The following parameters were measured and obtained for further analysis: blood parameters, artery diameter of the internal carotid artery, end-tidal CO2 in expired air, the cardiac...
-
Modelling of subarachnoid space width changes in apnoea resulting as a function of blood flow parameters
PublicationDuring apnoea, the pial artery is subjected to two opposite physiological processes: vasoconstriction due to elevated blood pressure and vasorelaxation driven by rising pH in the brain parenchyma. We hypothesized that the pial artery response to apnoea may vary, depending on which process dominate. Apnoea experiments were performed in a group of 19 healthy, non-smoking volunteers (9 men and 10 women). The following parameters...
-
Nanocrystalline cathode functional layer for SOFC
PublicationRecently, it was shown that thin functional layers introduced between an electrolyte and cathode might improve cathode performance. However, the mechanism of this improvement still needs analysis. In this paper, a thin (∼140 nm), spin-coated perovskite layer (La0.6Sr0.4Co0.2Fe0.8O3-δ) was placed between a cathode (La0.6Sr0.4Co0.2Fe0.8O3-δ) and an electrolyte (Ce0.8Gd0.2O2-δ) and the effects of this investigated. The microstructure...
-
Nanostruktury w katodach tlenkowych ogniw paliwowych
PublicationCelem badań przeprowadzonych w trakcie realizacji pracy doktorskiej było zbadanie i opracowanie nanostruktur, które można wykorzystać w celu podniesienia wydajności katod w tlenkowych ogniwach paliwowych. Bazując na przeglądzie literaturowym przedstawionym, spośród różnych kierunków badań nad poprawą wydajności katod wybrano dwa, które wykorzystują struktury o charakterystycznych wymiarach rzędu dziesiątek nanometrów....
-
New perspective on the in vivo use of cold stress dynamic thermography in integumental reconstruction with the use of skin-muscle flaps
PublicationAmong the problems encountered by plastic surgeons is the reconstruction of defects following tumors. One of the reconstructive options is TRAM flap. Despite that anatomy is well-explored, marginal flap necrosis may develop. To minimize complications imaging examinations was designed to determine the degree of flap perfusion. One of them is the thermographic examination.
-
Nitrogen dioxide sensing properties of PEDOT polymer films
PublicationThis work presents a simple and fully electrochemical route for the polymerization of poly(3,4-ethylenedioxytiophene) (PEDOT) films for fabricating a NO2 gas sensor prepared by electropolymerization of 3,4-Ethylenedioxythiophene (EDOT) monomer in lithium perchlorate/acetonitrile solution. The main aim of this study is to determine the sensing properties of conductive polymer at elevated temperatures. The effects of the humidity,...
-
Open smart glasses development platform for AAL applications
PublicationThis paper describes an open platform for multi sensory electronic glasses that supports new and enhanced methods for intelligent interaction with patients, with smart objects, or to be used as new data input modalities like proximity sensor or smart textile interfaces. All the activities have been developed, investigated and evaluated within EU CHIST-ERA eGlasses project...
-
Performance of a single layer fuel cell based on a mixed proton-electron conducting composite
PublicationMany of the challenges in solid oxide fuel cell technology stem from chemical and mechanical incompatibilities between the anode, cathode and electrolyte materials. Numerous attempts have been made to identify compatible materials. Here, these challenges are circumvented by the introduction of a working single layer fuel cell, fabricated from a composite of proton conducting BaCe0.6Zr0.2Y0.2O3-δ and a mixture of semiconducting...
-
Playback detection using machine learning with spectrogram features approach
PublicationThis paper presents 2D image processing approach to playback detection in automatic speaker verification (ASV) systems using spectrograms as speech signal representation. Three feature extraction and classification methods: histograms of oriented gradients (HOG) with support vector machines (SVM), HAAR wavelets with AdaBoost classifier and deep convolutional neural networks (CNN) were compared on different data partitions in respect...
-
Pose classification in the gesture recognition using the linear optical sensor
PublicationGesture sensors for mobile devices, which have a capability of distinguishing hand poses, require efficient and accurate classifiers in order to recognize gestures based on the sequences of primitives. Two methods of poses recognition for the optical linear sensor were proposed and validated. The Gaussian distribution fitting and Artificial Neural Network based methods represent two kinds of classification approaches. Three types...
-
Proposal of New Tracer Concentration Model in Lung PCT Study Comparison with Commonly Used Gamma-variate Model
PublicationPerfusion computed tomography (pCT) is one of the methods that enable non-invasive imaging of the hemodynamics of organs and tissues. On the basis of pCT measurements, perfusion parameters such as blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface (PS) are calculated and then used for quantitative evaluation of the tissue condition. To calculate perfusion parameters it is necessary to approximate...
-
Recurrent potential pulse technique for improvement of glucose sensing ability of 3D polypyrrole
PublicationIn this work, a new approach for using a 3D polypyrrole (PPy) conducting polymer as a sensing material for glucose detection is proposed. Polypyrrole is electrochemically polymerized on a platinum screen-printed electrode in an aqueous solution of lithium perchlorate and pyrrole. PPy exhibits a high electroactive surface area and high electrochemical stability, which results in it having excellent electrocatalytic properties. The...
-
Sinusoidal Alternating-Current Voltammetry and Metrological Properties of a Flat Voltammetric Electrode in the Time Domain
PublicationIn this paper there were analyzed metrological properties of a flat electrode used to mark ions with the method of sinusoidal alternating-current voltammetry in the situation where on its surface an electrochemical reversible reaction of oxidizing / reduction takes place. The result of the analysis conducted is that such a voltammetric electrode functions like a converter type I. Metrological properties of such an electrode in...
-
Spray pyrolysis of doped-ceria barrier layers for solid oxide fuel cells
PublicationGadolinium doped ceria (Ce0.8Gd0.2O2 − x-CGO) layer fabricated by spray pyrolysis is investigated as the diffusion barrier for solid oxide fuel cell. It is deposited between the La0.6Sr0.4FeO3 − δ cathode and the yttria stabilized zirconia electrolyte to mitigate harmful interdiffusion of elements. The parameters of the fabrication process are linked to the measured area specific resistances of the symmetrical cells and the efficiency...
-
Status report on high temperature fuel cells in Poland – Recent advances and achievements
PublicationThe paper presents recent advances in Poland in the field of high temperature fuel cells. The achievements in the materials development, manufacturing of advanced cells, new fabrication techniques, modified electrodes and electrolytes and applications are presented. The work of the Polish teams active in the field of solid oxide fuel cells (SOFC) and molten carbonate fuel cell (MCFC) is presented and discussed. The review is oriented...
-
Study of Metrological Properties of Voltammetric Electrodes in the Time Domain
PublicationMetrological properties of voltammetric electrodes, in the situation where on their surface an electrochemical reaction of oxidizing/reduction takes place, were analyzed in this chapter. The properties of electrodes on which a reaction controlled by ion transport process takes place were taken into consideration. Also, it was analyzed how the electrode’s shape and the voltage polarizing the electrode influence this electrode’s...
-
Surgical tool tracking by on-line selection of structural correlation filters
PublicationIn visual tracking of surgical instruments, correlation filtering finds the best candidate with maximal correlation peak. However, most trackers only consider capturing target appearance but not target structure. In this paper we propose surgical instrument tracking approach that integrates prior knowledge related to rotation of both shaft and tool tips. To this end, we employ rigid parts mixtures model of an instrument. The rigidly...
-
Tailoring the electrochemical degradation of iron protected with polypyrrole films for biodegradable cardiovascular stents
PublicationThe degradation of polypyrrole (PPy) coated iron is studied in phosphate buffer saline solution at 37 °C by odd random phase multisine electrochemical impedance spectroscopy (ORP-EIS). PPy is electropolymerized with anti-inflammatory salicylates incorporated in the film, as a drug release system. The modelling of EIS over time provides the quantitative description of the corrosion behaviour of the material. Thus, the reliable...
-
The motion influence on respiration rate estimation from low-resolution thermal sequences during attention focusing tasks
PublicationGlobal aging has led to a growing expectancy for creating home-based platforms for indoor monitoring of elderly people. A motivation is to provide a non-intrusive technique, which does not require special activities of a patient but allows for remote monitoring of elderly people while assisting them with their daily activities. The goal of our study was to evaluate motion performed by a person focused on a specific task and check...
-
The role of EMG module in hybrid interface of prosthetic arm
PublicationNearly 10% of all upper limb amputations concern the whole arm. It affects the mobility and reduces the productivity of such a person. These two factors can be restored by using prosthetics. However, the complexity of human arm makes restoring its basic functions quite difficult. When the osseointegration and/or targeted muscle reinnervation (TMR) are not possible, different modalities can be used to control the prosthesis. In...
-
Time window based features extraction from temperature modulated gas sensors for prediction of ammonia concentration
PublicationElectronic gas recognition systems, in literature commonly referred as electronic noses, enable the recognition of a type and a concentration of various volatile compounds. Typical electronic gas-analyzing device consists of four main elements, namely, gas delivery subsystem, an array of gas sensors, data acquisition and power supply circuits and data analysis software. The commercially available metal-oxide TGS sensors are widely...
-
Tomografia perfuzyjna pCT w diagnostyce cukrzycowej mikroangiopatii płucnej
PublicationNiniejsza rozprawa jest poświęcona zagadnieniom diagnostyki mikroangiopatii płucnej ze szczególnym uwzględnieniem perfuzyjnej tomografii komputerowej (pCT). Retinopatia, nefropatia i neuropatia są znanymi powikłaniami cukrzycy. Mało poznany jest wpływ cukrzycy na funkcjonowanie układu oddechowego. Obecnie stosowana metoda diagnostyki cukrzycowej mikroangiopatii płucnej ma ograniczoną wiarygodność. W rozprawie została przedstawiona...
-
Using wearable device for biomedical signal acquisition and processing
PublicationIn this paper we present the research conducted on synchronous measurements of biosignals. The experiment was conducted to evaluate the possibility of estimating vital signs based on eye tracking. Method: The eGlasses platform was used for acquisition of ECG, respiration rate, eye and pupil movement and blood pressure. Data were acquired in three 5 min. intervals during which a subject was performing certain tasks. The signals...
-
Virtual designs and reconstructions of amber works: Amber craftsman simulator
PublicationThis paper presents the concept of visualization of amber works in a virtual reality cave. It describes problems encountered during the acquisition, modeling and rendering of geometrical objects distinguished by heterogeneous transparency.
Year 2016
-
3D polypyrrole structures as a sensing material for glucose detection
PublicationIn this work, 3D polypyrrole (PPy) structures as material for glucose detection is proposed. Polypyrrole was electrochemically polymerized on platinum screen-printed electrode from an aqueous solution of lithium perchlorate and pyrrole. The growth mechanism of such PPy structures was studied by ex-situ scanning electron microscopy. Preliminary studies show that studied here PPy film is a good candidate as a sensing material for...
-
A new diagnostic IR-thermal imaging method for evaluation of cardiosurgery procedures
PublicationTwo methods for monitoring the state of the myocardium during cardiosurgical interventions based on thermal IR imaging are presented below. These methods, called static thermography and active dynamic thermography (ADT), use information about the distribution of temperature on the surface, and an external excitation source to induce thermal transient processes in a tested object. Recording the time series of thermograms allows...
-
A new diagnostic method for evaluation of cardiosurgery wound healing
PublicationOne of important and still unsolved problems in medicine is the question of objective and quantitative evaluation of post-surgery wound healing. The aim of this research is to analyse possibility and value of using the newly elaborated infrared imaging procedure – Active Dynamic Thermography (ADT) – for quantitative description of wound healing processes in cardiosurgery. Both, classical thermal figures of merit as well as ADT...
-
A novel concept for tissue-metal detection and differentiation using an inductive proximity sensor
PublicationIn this paper a novel application of inductive proximity sensors for detection of living tissue by means of measurements of the coil impedance changes at different frequencies is described. The mathematical analyses utilizing Bessel function estimation include detected object size and its distance from a sensor. The main aim of this study is to prove the possibility of distinguishing between metal objects and living tissues. The...
-
Accuracy analysis of the RSSI BLE SensorTag signal for indoor localization purposes
PublicationIn this paper we describe possibility of use the RSSI signal (Radio Signal Strength Indication) from Texas Instruments SensorTag CC2650 for indoor positioning purposes. This idea is not a new but in our opinion it is possible to use SensorTags with Bluetooth LE wireless interface for positioning inside buildings in such applications as people findings in hospitals, senior come care, etc. RSSI is mostly selected as the sensor localization...
-
Active IR-Thermal Imaging in Medicine
PublicationIn this paper we summarize results of several research projects devoted to development of new diagnostic methods and procedures based on quantitative infrared thermography in medical applications. First, basics of active dynamic thermography are presented. Described are both, instrumentation and software comprising measurement procedures including collection of series of IR-images after external excitation, data treatment with...