  • A Novel Device and System for Fall Detection Under the Shower
    Publikacja

    In this paper, device construction and preliminary results for shower safety assistance are presented. The device allows monitoring of shower-taking persons without violating privacy and intimacy, while it has the ability to detect a persons entering and leaving the shower and detecting fall conditions. It allows better supervision of elders living independently at their locations.

    Pełny tekst do pobrania w serwisie zewnętrznym

Rok 2023
Rok 2022
  • QRS Morphology-Based EDR Signal—Factors Determining its Properties
    Publikacja

    Respiration-induced signals contain a clinically significant information. It could be obtained utilizing both direct and indirect methods. ECG-Derived Respiration (EDR) method is the latter one. However, in this case, two approaches could be distinguished. First one is based on determining changes in the morphology of QRS complexes while the second one is based on the Respiratory Sinus Arrhythmia (RSA) mechanism. The former approach...

    Pełny tekst do pobrania w portalu

Rok 2021
  • Influence of preprocessing techniques on pulse pressure velocity determination

    Pulse Wave Velocity (PWV) is measured and utilized in many clinical applications. Recently, a wide research has been led to develop a cuff-less and continuous blood pressure method basing on PWV. However, in this application a decision on choosing an appropriate fiducial point of pulse wave (PW) waveform is necessary and substantial. It would allow to measure time parameters necessary to determine PWV. An influence of sampling...

    Pełny tekst do pobrania w serwisie zewnętrznym

Rok 2020
Rok 2019
Rok 2018
Rok 2017
  • A body position influence on ECG derived respiration

    An influence of a human body position on ECG derived respiration (EDR) signal is presented in the paper. Examinations were performed during deep, suspended and normal breathing for eight people in four different body positions. EDR and thoracic impedance signals were compared using correlation and standard deviation coefficients. Obtained results have shown that it is possible to monitor breath activity of people being in different...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Extending touch-less interaction with smart glasses by implementing EMG module

    In this paper we propose to use temporal muscle contraction to perform certain actions. Method: The set of muscle contractions corresponding to one of three actions including “single-click”, “double-click” “click-n-hold” and “non-action” were recorded. After recording certain amount of signals, the set of five parameters was calculated. These parameters served as an input matrix for the neural network. Two-layer feedforward neural...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • The role of EMG module in hybrid interface of prosthetic arm

    Nearly 10% of all upper limb amputations concern the whole arm. It affects the mobility and reduces the productivity of such a person. These two factors can be restored by using prosthetics. However, the complexity of human arm makes restoring its basic functions quite difficult. When the osseointegration and/or targeted muscle reinnervation (TMR) are not possible, different modalities can be used to control the prosthesis. In...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Using wearable device for biomedical signal acquisition and processing

    In this paper we present the research conducted on synchronous measurements of biosignals. The experiment was conducted to evaluate the possibility of estimating vital signs based on eye tracking. Method: The eGlasses platform was used for acquisition of ECG, respiration rate, eye and pupil movement and blood pressure. Data were acquired in three 5 min. intervals during which a subject was performing certain tasks. The signals...

    Pełny tekst do pobrania w serwisie zewnętrznym

Rok 2016
Rok 2015
Rok 2014
Rok 2013
Rok 2012
Rok 2011
  • Analysis of correlation between heart rate and blood pressure
    Publikacja

    - Rok 2011

    W artykule przedstawiono analizę korelacji pomiędzy częstością akcji serca (HR) i ciśnieniem krwi (BP). Wykorzystano rzeczywiste pomiary ciśnienia skurczowego i rozkurczowego krwi zmierzonego metodą inwazyjną w tętnicy promieniowej. Ze względu na możliwe zaszumienie sygnału przeanalizowano także dane po filtracji filttrem uśredniającycm oraz wykonano analizę trendów sygnałów. Wyniki analizy zarówno danych pomiarowych jak i filtrowanych...

    Pełny tekst do pobrania w serwisie zewnętrznym