Filtry
wszystkich: 214
wybranych: 185
Wyniki wyszukiwania dla: currents
-
Comprehensive compensation of grid current distortion by shunt active power filters
PublikacjaThe paper presents a comprehensive approach to the compensation of grid current distortion in shunt active power filter systems. Four sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the evaluation of grid voltages and computation of compensating currents, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Five-phase induction motor drive with sine-wave filter
PublikacjaThe paper presents closed loop ac drive with 5 phase induction motor operating with voltage source inverter and sine wave filter. The motor supply voltages and currents have sinusoidal shape. For well known adjustable electric drives the field oriented control method with flux and speed co ntrol can be applied. In the presence of output filter both control and estimation algorithms should be modified due to sine wave filter installation....
-
Potential changes in an electric field and electrolytic corrosion.
PublikacjaSources have been described of corrosively hazardous electric fields and methods of determination of the corrosion hazard to metal structures caused by electrolytic corrosion. Results of potential and impedance investigations in the field of stray currents flowing out of a tram traction and in the presence of a defined electric field of low frequency have been presented. Uncertainties have been indicated relating to the generally...
-
Protection of bridges against stray current corrosion
PublikacjaA case study of Siennicki Bridge stray current corrosion hazard is presented. A corrosion risk was caused by incorrectly designed tram line traction which goes over the bridge. No dielectric insulation between running rails and bridge steel construction was used. A variety of protection methods against stray currents are described. Characteristics of the endangered bridge were described. Impressed current cathodic protection system...
-
Influence of temperature and interactions with ligands on dissociation of dsDNA and ligand-dsDNA complexes of various types of binding : an electrochemical study.
PublikacjaSeveral medicinally important compounds that bind to dsDNA strands via intercalation (C-1311, C-1305, EtBr), major groove binding (Hoechst 33258) and covalent binding (cis-Pt) were examined. The obtained results suggest that both the transfer of conformation B to C and the denaturation process, for the ligand-dsDNA complexes, except for covalently bound cis-Pt, took place at higher temperatures compared to the unbound helix. Furthermore,...
-
Error analysis of calculating average d-q current components using Regular Sampling and Park transformation in FOC drives
PublikacjaIn electric drives using voltage source inverters, motor currents contain ripple component resulting from pulse-width modulated (PWM) voltage. The frequency range of the ripples is much higher than the bandwidth of current control. Therefore the control is performed on the basis of a fundamental current component, i.e. average value with the averaging time being the PWM period. In majority of cases the average current is measured...
-
Safety issues referred to induced sheath voltages in high-voltage power cables – case study
PublikacjaLoad currents and short-circuit currents in high-voltage power cable lines are sources of the induced voltages in the power cables’ concentric metallic sheaths. When power cables operate with single-point bonding, which is the simplest bonding arrangement, these induced voltages may introduce an electric shock hazard or may lead to damage of the cables’ outer non-metallic sheaths at the unearthed end of the power cable line. To...
-
Model and laboratory simulation of a induction motor for diagnostic purposes
PublikacjaStatistics say that bearings are this part of induction motors which is most susceptible to damage. The equipment employed for bearing diagnostics usually makes use of vibrations as the criterion for technical condition of the bearings. A faulty bearing results in additional motor vibrations. They are reflected in the harmonic content of stator currents. In certain operating conditions the current signal is the sole source of information...
-
The influence of the motor filtrers on harmonic current emmision in the pro-ective connection of drive systems.
PublikacjaThis paper contains detailed analysis of currents in protective wire in engine supplied from frequency converter without any external filters added. It was found that the peak value of current in protective conductor of engine was about 1500 mA at frequencies 5 Hz 50 Hz. In the continuation of research the dU/dt type motor filter and the sinusoidal filter were tested. It was found that the current in protective wire decreased...
-
RCDs Tripping in the Range from DC to AC 50 kHz for Slowly Rising Residual Current
PublikacjaThe wide use of power electronic converters means that in many low-voltage systems earth fault currents containing components from DC to AC of various frequencies have to be taken into account. Due to the tendency to increase the modulation frequency in converters, components of higher frequencies may be in the order of several tens of kilohertz. Therefore, it is very important to verify the behavior of devices for protection against...
-
Impact of digital signal processing on FOC current feedback in high-speed PMSM drive
PublikacjaIn applications where size and weight of the electric motor are among major design concerns, Permanent Magnet Synchronous Motors (PMSMs) with wide operational speed-range are commonly preferred. Due to limited inverter switching frequency, high-speed operation of a drive results in a low ratio between the switching frequency and the fundamental frequency of motor voltage. Such operating conditions have been recently identified...
-
Dynamics of fault arc traveling along busbars in high voltage switchboards = Dynamika łuku zwarciowego przemieszczającego się wzdłuż szyn rozdziel-nic wysokiego napięcia
PublikacjaThe paper presents the results of magnetic induction and electrodynamic force calculations acting on arc column during short-circuit in medium voltage air-insulated bus-bars. The gap between the bars was 120 mm and the prospective short-circuit currents ranged from 4 kA to 8 kA. The paper also shows the measurement results of average velocity fault arc depending on currents arc diameter and arc current was established and described....
-
Prądy łożyskowe w układach napędowych z silnikami indukcyjnymi
PublikacjaW pracy przedstawiono problemy występujące w układach napędowych z silnikami indukcyjnymi zasilanymi z falownika napięcia. Zwrócono uwagę na rosnącą liczbę uszkodzeń silników w napędach przekształtnikowych. Wskazano przyczyny wynikające z charakteru zasilania przekształtnikowego silnika. Główną uwagę poświęcono prądowi łożyskowemu, który odpowiada za większość awarii maszyn. Przedstawiono rodzaje prądów łożyskowych, wyjaśniając...
-
Bezczujnikowe sterowanie trakcyjnym silnikiem IPMSM małej mocy
PublikacjaThis paper describes an algorithm for estimation of IPMSM angular rotor position. The algorithm uses derivatives of motor phase currents resulting from PWM modulation to obtain the rotor position. Control of the IPMSM electromagnetic torque requires a precise estimation of the rotor angular position throughout the wide speed range. This involves using a set of estimation methods switched with the dependence on the actual rotor...
-
Double Fed Induction Machine Drives
PublikacjaContents of the Chapter 22:Machine model.Properties of the DFM.Steady state machine operation.Control rules and decoupled control.Decoupling based on MM machine model.Decoupling based on vector model.Decoupling based on rotor current equation.Overall control system.Control system based on MM model.Control system based on vector model.Estimation of variables.Calculation of the angle between stator and rotor.Remarks about digital...
-
Reduction of the Velocity Impact on the Magnetic Flux Leakage Signal
PublikacjaThe velocity effect on the magnetic flux leakage (MFL) signal was investigated in this paper. Experiments were performed for velocity of the MFL tool within the range of 0–2 m/s. The velocity was not constant during each measurement to imitate real operational conditions of the MFL tool. Two components of the leakage were measured, i.e. the tangential to the motion direction (x) and the normal to the investigated surface (z). In...
-
Calculations of Short-Circuit Current Flows in Earth Wires of HV Lines
PublikacjaThis paper presents a method which enables calculating flows of short-circuit currents in earth wires of high voltage transmission lines, and its implementation in the form of a computer programme. The algorithm enables performing calculations for a double-fed line and starconnected lines (three terminal lines). The developed programme enables verifying dimensioning of earth wires in the context of their short-circuit thermal withstand...
-
Residual current devices in installations with PV energy sources
PublikacjaThe paper presents the principles of residual current devices (RCDs) application in photovoltaic (PV) installations. Provisions of standards in this regard are commented on, in particular, attention is drawn to the lack of obligation to use of RCDs in PV installations. The issue of the shape of the earth fault current and the level of leakage currents in such installations are discussed. These factors influence the selection of...
-
AC motor feeding cable consequences on EMC performance of ASD
PublikacjaHigh level of conducted EMI emissions of adjustable speed drives (ASD) is one of the most difficult problems in contemporary applications. Many investigations are carried out in order to find more effective methods allowing to predict this emission at early stage of design, and therefore to predict adequate countermeasures. This paper deals with the method which allows to estimate by simulation the influence of motor feeding cable...
-
Selection of C-Type Filters for Reactive Power Compensation and Filtration of Higher Harmonics Injected into the Transmission System by Arc Furnaces
PublikacjaThis article presents a method for selecting the elements of a C-type filter working with a conventional LC-type filter for compensating reactive power and filtering out higher harmonics generated by arc furnaces and ladle furnaces. The study was conducted in a steel mill supplied by a 110 kV transmission system, where higher harmonic currents and nonlinear loads were measured. A series of computer simulations were performed under...
-
Arctic as a reservoir for polycyclic aromatic hydrocarbons and polychlorinated biphenyls- water samples from Foxfonna glacier
PublikacjaPolycyclic aromatic hydrocarbons and polychlorinated biphenyls are groups of stable compounds, hard to biodegrade, potentially toxic. Their presence in Arctic environment may have a big impact on natural balance, fauna and flora. Although Arctic areas should be unpolluted, some amounts of pollutants are transferred from lower latitudes with sea currents and air masses. This paper presents the amounts of selected persistent organic...
-
ANALIZA WPŁYWU NIEJEDNOCZESNOŚCI ZAMYKANIA BIEGUNÓW ŁĄCZNIKA NA PRĄDY ZAŁĄCZENIOWE TRANSFORMATORA W STANIE JAŁOWYM
PublikacjaW artykule przedstawiono wyniki obliczeń symulacyjnych prądów załączeniowych transformatora dla różnych sekwencji zamykania biegunów łącznika. Sekwencje różniły się kolejnością łączenia faz oraz czasami opóźnienia w zamykaniu biegunów. Rozważono także kilka wariantów stanu namagnesowania szczątkowego rdzenia. Na podstawie analizy wyników stwierdzono, że przy jednoczesnym zamykaniu biegunów łącznika, właściwy dobór chwili załączenia...
-
Analysis of degaussing process of ferromagnetic objects
PublikacjaResults of the analytical and numerical analysis of the degaussing process phenomena of ferromagnetic objects were presented in this paper. The screening effectiveness of the electromagnetic field of magnetic screens in most cases depends on thickness, conductivity, magnetic permeability of the screen and angular frequency of degaussing currents. The magnetic field inside thin-layer ferromagnetic object was presented in this paper....
-
Impulse Impedance Measurements of Lightning Protection Earthings
PublikacjaLightning protection earthing systems should be tested at currents with time parameters similar to those of lightnings. A method and definition of a measured value of impulse impedance are introduced. The impulse impedance was determined by a quotient of voltage drop on the tested earthing to a value of current in measure circuit. The usefulness of the impulse method for lightning protection evaluation is tested on radio base stations...
-
Diagnostics of zno varistors by means of nondestructive testing
PublikacjaStandard industrial testing of high-voltage varistors for surge arresters demands application of high voltages and intensive currents. Nondestructive methods for varistor quality and endurance evaluation have been proposed and described. They rely on the application of resonant ultrasound spectroscopy, electro-ultrasonic spectroscopy, noise measurement and nonlinearity testing at voltages lower than continuous operating range....
-
Compensation of Dead Time Effects for Shunt Active Power Filters
PublikacjaThe paper presents a comprehensive approach to the compensation of the grid current distortion for shunt active power filter systems. Four different sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the estimation of compensating currents and grid voltages, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Early Oceanographical Data Collected by the Institute of Oceanography, University of Gdańsk
PublikacjaThree data sets entitled Water currents in Głębinka Passage in late spring of 1975, Hydrometeorological and hydrochemical conditions in the Gulf of Gdańsk in the vicinity of Vistula river mouth in July of 1977, and Gulf of Gdańsk monitoring conducted by the Institute of Oceanography, University of Gdańsk, in 1981–1994 contain archival field measurement results from the Gulf of Gdańsk (the southern Baltic). The data can be used...
-
Compensation of supply current harmonics, reactive power, and unbalanced load current balance in the closed-loop control of a shunt active power filter
PublikacjaThis paper presents the compensation tasks performed by a shunt active power filter, including compensation of harmonic currents, reactive power, and an unbalanced load current. The paper demonstrates novel control of the shunt active power filter in a closed-loop system. The control algorithm was verified by performing simulations and compared the simulated results with those obtained in an open-loop control system. All simulations...
-
Trends in Locally Balanced Energy Systems without the Use of Fossil Fuels: A Review
PublikacjaIn recent years, the idea of the operation of energy systems (power systems, heating systems) has changed significantly. This paper is an overview of locally balanced energy systems without the use of fossil fuels. The paper justifies the concept of local energy balancing in a new energy system that does not use fossil fuels (coal, natural gas, and crude oil), based on European Union guidelines and formal documents as well as the...
-
A predictive estimation based control strategy for a quasi-resonant dc-link inverter
PublikacjaIn this paper the predictive estimation based control strategy for a quasi-resonant dc link inverter (PQRDCLI) is developed. Instead of direct measurement of dc link input inverter current – its estimation with one step prediction is applied. The PQRDCLI fed induction motor, controlled with a predictive current estimation stabilized inverter output voltage slopes independently of load. Moreover, reduction of overvoltage spikes...
-
Detection and time/frequency analysis of electric fields in the ground
PublikacjaThis paper sets out to detect and characterize electric fields in the ground (such as stray current fields) using a tandem time/frequency method of signal analysis. Results were obtained from investigations performed in the presence of a generated electric field with controlled variable characteristics, and in the presence of an electric field generated by a tramline. The analysis of measurement registers was performed using Short‐Time...
-
Suppression of Supply Current Harmonics of 18-Pulse Diode Rectifier by Series Active Power Filter with LC Coupling
PublikacjaThe reported research aims at improving the quality of three-phase rectifier supply currents. An effective method consists of adding properly formed booster voltages to the fundamental supply voltages using a series active filter. In the proposed solution, the booster voltages are generated by three single-phase systems consisting of inverters, LC filters, and single-phase transformers. The application of LC couplings ensures low...
-
Niekorzystny wpływ przekształtnikowego zasilania PWM na silniki asynchroniczne trakcyjne
PublikacjaThe electric traction drives with an AC motor fed by a frequency converter are used more and more often nowadays. The most significant side effects, of a converter's output voltage forming PWM method for AC motor windings, are steep voltage changes, which can initiate several destructive phenomena. The paper presents the adverse influence of a converter common mode voltage on the motor windings' increased voltage exposure and the...
-
Destructive impact of PWM inverters on traction AC motors
PublikacjaThe electric traction drives with an AC motor fed by a frequency converter are used more and more often nowadays. The most significant side effects, of a converter's output voltage forming PWM method for AC motor windings, are steep voltage changes, which can initiate several destructive phenomena. The paper presents the adverse influence of a converter common mode voltage on the motor windings's increased voltage exposure and...
-
Destructive Consequences of PWM Inverter Feeding for Traction AC Motors
PublikacjaThe electric traction drives with an AC motor fed by a frequency converter are used more and more often nowadays. The most significant side effects, of a converter's output voltage forming PWM method for AC motor windings, are steep voltage changes, which can initiate several destructive phenomena. The paper presents the adverse influence of a converter common mode voltage on the motor windings' increased voltage exposure and the...
-
Estimation of interior-permanent-magnet-synchronous-motor rotor position by analysis of phase-current derivatives
PublikacjaThis paper describes an algorithm for estimation of IPMSM rotor angular position. The algorithm uses derivatives of motor phase currents resulting from PWM modulation to obtain the rotor position. The presented method is designed for medium- and high-speed range, since it is based on determination of the EMF vector. Calculation of the motor position is performed in every PWM cycle. The standard SV-PWM method is used to determine...
-
Quality assessment of high voltage varistors by third harmonic index
PublikacjaHigh voltage varistors that consist of grained ZnO have to be tested before assembling into a surge arrester. The existing methods demand a usage of high voltages and intensive currents that is inconvenient, destructive and needs extensive power consumption. Additionally, these methods require metallization of the prepared varistor structures that increases costs. We propose another method of varistors quality assessments by a...
-
Application of Illuminating Modes concept in modal expansion of elliptical resonator
PublikacjaIn the paper an IlluminatingModes (IM) approach as an extension of Spectral Domain Approach (SDA) is presented. IM concept is applied to the case of open microstrip planar elliptical resonator. A modal expansion of currents induced in the structures during illuminating them by a single plane wave is the novelty of the method. As an example of application of the method, we present the results obtained by an examination of two resonators...
-
Sensorless algorithm for sustaining controllability of IPMSM drive in electric vehicle after resolver fault
PublikacjaThis paper presents a sensorless algorithm designated for the emergency control of an interior permanent magnet synchronous motor (IPMSM) drive in electric or hybrid vehicle. The algorithm is based on analysing the derivatives of motor phase currents measured over the duration of particular inverter states. The method is computationally simple and does not require additional hardware since the derivatives are measured indirectly....
-
IPMSM rotor position estimator based on analysis of phase current derivatives
PublikacjaThis paper describes an algorithm for estimation of IPMSM angular rotor position. The algorithm uses derivatives of motor phase currents resulting from PWM modulation to obtain the rotor position. The presented method is designed for medium- and high-speed range, since it is based on determination of the EMF vector. Algorithm is characterised by a very simple formulae. The calculation of rotor position is performed in every PWM...
-
Disturbances of magnetic field in surrounding of mobile, metalic plate
PublikacjaThe uniform magnetic field of the Earth in the surrounding of a mobile, metalic object undergoes deformation by eddy currents. The influence of the moving conducting object on total magnetic field of the Earth depends on the object's shape, position and speed of the changes relative to the magnetic field's vector of the Earth as well as the electric conductivity and the relative magnetic permeability of the material. The disturbances...
-
Third harmonic index as a diagnostic tool of high-voltage varistors
PublikacjaThe recommended methods for standard testing of high-voltage varistors demand application of high voltages and intensive currents that is inconvenient and needs extensive power consumption. These methods require metallization of the prepared ZnO structures that increases costs of testing. Another method of varistor quality and endurance evaluation by the third harmonic index measurement at relatively low voltage range has been...
-
Formowanie napięć wyjściowych trójfazowego przekształtnika sieciowego
PublikacjaW artykule przedstawiono kompensację dwu zasadniczych zjawisk powodujących zniekształcenia prądów fazowych przekształtnika sieciowego. Pierwszym z nich są zniekształcenia napięcia sieci. W celu ich eliminacji zaproponowano uśrednianie za okres podstawowej harmonicznej uchybu regulatora napięcia obwodu pośredniczącego oraz predykcję napięcia sieci. Drugim natomiast są zniekształcenia napięć wyjściowych przekształtnika sieciowego....
-
Non-linear circuit model of a single doubly-fed induction machine formulated in natural axes for drive systems simulation purposes
PublikacjaMathematical modelling and a circuit model formulated in natural axes of a single doubly-fed induction machine, with the account of magnetic circuit nonlinearity are presented in the paper. Derivation of the model differential equations was based on Lagrange's energy method. State functions of magnetic elements in the model are non-linear and depend on all currents flowing in the machine windings and on the angle of rotor position....
-
Polyarmonic model of synchronous generator for analysis of autonomous power generation systems
PublikacjaAbstract: This paper presents the polyharmonic modelling of synchronous generator (SG) in machine variables. The simple geometry and windings physical layout has been used for inductance calculations of a salient-pole SG. The main advantage of this model is the ease of describing an autonomous power generation system (APGS) in terms of its topology and thus providing effective analysis at the static and dynamic states, both for...
-
Power Electronic Transformer For Smart Grid Application
PublikacjaIn this paper the control system of Power Electronic Transformer (PET) for the Smart Grid application is proposed. The structure of PET is based on two Cascaded H-bridge (CHB) converters. The electrical energy is transferred between converters using Dual-Active-Bridges (DAB) and high-frequency transformers. This type of coupling has been used to connect the DC-links of all H-bridges. The proposed control system for PET makes it...
-
Energy losses reduction in the medium voltage cable line – case study
PublikacjaThe paper presents an analysis of energy losses in a power cable system, which is composed of two 30 kV cable lines. This cable system is located at the seaside holiday area, so the load profile during a year is specific. Energy losses related to reactive power transmission, as well as to currents induced in the sheaths of the cables, are subject to analysis. Measurements were made in the system in order to prepare a computer model...
-
Analysis of magnetic disturbances of air platform caused by induced magnetisation
PublikacjaMagnetometric systems installed on air platforms like airplanes or helicopters are equipped in compensators of magnetic disturbances. Time changes of the platform's position caused generation of magnetic disturbances. The permanent and induced magnetization of ferromagnetic elements and eddy currents induced in conducting parts of the platform are sources of these disturbances. The linear model of magnetic disturbances of platforms...
-
Representation of magnetic hysteresis in single-phase transformer for circuit simulations
PublikacjaThe paper presents a mathematical model for the hysteresis phenomenon in a multi-winding single-phase core type transformer. In the circuit transformer model, it is assumed that there is a flux common Φ to all windings as nonlinear and hysteretic function of the total currents Θ (Ampere turns) of all windings. To simulate magnetic behaviour of the iron core the feedback scalar Preisach model of hysteresis is developed. The Preisach...
-
Sensorless induction motor drive with voltage inverter and sine-wave filter
PublikacjaThis paper presents a speed sensorless control system of an induction motor with an output LC filter. It is known that the parameters design of the filter gives sine wave motor supply voltage but complicates control and estimation process. The reason is that the voltage drop and phase shift between filter input and output signals are imposed, and hence the motor voltages and currents differ from the inverter output waveforms. To...