Filtry
wszystkich: 295
wybranych: 240
Wyniki wyszukiwania dla: CORROSION, MONITORING, CRUDE OIL, REFINERY, SENSORS
-
Complex Corrosion Monitoring System for Crude Distillation Unit in Form of Neutral Network
PublikacjaComplex and successful corrosion monitoring of refinery processes can significantly reduce material losses and failure risk. The developed corrosion monitoring system is based on online ultrasonic sensors, ER (electrical resistance) probes, gravimetric method and multipoint analytical analysis of chemical composition of the fluids. Additional online LPR (linear polarization resistance) sensors controlling corrosiveness of sour...
-
Corrosion mechanisms in columns for atmospheric distillation of crude oil
PublikacjaThe paper presents the most common corrosion processes occurring in the columns for atmospheric distillation of crude oil. It describes the mechanisms leading to formation of the chemical compounds, which contribute to corrosion phenomena. The main technological factors influencing corrosion processes have been indicated. The paper also presents the interactions between particular corrosion mechanisms resulting in acceleration...
-
Oil refinery dusts: morphological and size analysis by TEM
PublikacjaThe objectives of this work were to develop a means of sampling atmospheric dusts on the premises of an oil refinery for electron microscopic study to carry out preliminary morphological analyses and to compare these dusts with those collected at sites beyond the refinery limits. Carbon and collodion membranes were used as asupport for collection of dust particles straight on transmission electron microscopy (TEM) grids. Micrographs...
-
A new technology of crude vegetable oil degumming with rhamnolipid solutions
PublikacjaA new technology of crude vegetable oil degumming is described. It is based on rhamnolipid biocomplex solution application for phosphatides removal. The rhamnolipid biocomplex produced by Pseudomonas sp. PS-17 was used as biosurfactant. Rapeseed oil was used in all experiments. First, it was degummed with H2SO4 in order to remove all phosphatides and then 1% (w/w) of granular soybean lecithin was added. Model oil was treated with...
-
Compatibility of Crude Oil Blends─Processing Issues Related to Asphaltene Precipitation, Methods of Instability Prediction─A Review
PublikacjaProcessing crude oil of variable composition, especially due to the need to process crude oil blends obtained from various sources, presents a tremendous process challenge. This is mainly due to the destabilization of the colloidal system manifested mostly by the precipitation of the asphaltene fraction. The precipitation of asphaltenes from crude oil is a serious problem during extraction, transport, and processing. In the latter...
-
ASSESSMENT OF GOLD AND/OR CRUDE OIL AS INVESTMENTS FOR PORTFOLIO DIVERSIFICATION. A WARSAW STOCK EXCHANGE CASE STUDY
PublikacjaThe purpose of the study is to assess whether the inclusion of investments in gold and/or crude oil improves an investment portfolio consisting of shares of enterprises included in the WIG20 index (traditional invest-ments). All possible combinations of investment portfolios with minimal risk and maximum efficiency were tested. The portfolios were determined based on Markowitz’s portfolio theory. All results were compared...
-
Corrosion-erosion damage of heat exchanger tubes by desalted crude oil flowing at shell side
Publikacja -
Corrosion-erosion damage of heat exchanger tubes by desalted crude oil flowing at shell side.
PublikacjaRurki wymiennika zostały uszkodzone lokalnie przez odsoloną ropę naftową przepływającą pod ciśnieniem 2,6 MPa i w temperaturze 385-395K. Większość powierzchni rurek nie była uszkodzona i była pokryta osadem związków organicznych i nieorganicznych, zabezpieczającym przed uszkodzeniami. Badania wykluczyły możliwość występowania intensywnej korozji elektrochemicznej na powierzchniach rurek pozbawionych osadu. Przyczyną perforacji...
-
Corrosion monitoring by harmonic analysis in aqueous environments
PublikacjaThis paper presents tests concerning the rate of corrosion in non-alloy steel (type S235JR) in an aqueous environment, with an additive of sodium chloride by means of polarization resistance measurements and harmonic analysis. The tests have been carried out for steel samples exposed to the testing environment for six weeks, in order to obtain a constant rate of corrosion in the function of time. The measurements have aimed at...
-
Magnetic superhydrophobic melamine sponges for crude oil removal from water
PublikacjaThis paper proposes the preparation of a new sorbent material based on melamine sponges (MS) with superhydrophobic, superoleophilic, and magnetic properties. This study involved impregnating the surface of commercially available MS with eco-friendly deep eutectic solvents (DES) and Fe3O4 nanoparticles. The DES selection was based on the screening of 105 eutectic mixtures using COSMO-RS modeling. Other parameters affecting the efficiency...
-
The influence of crude glycerol and castor oil-based polyol on the structure and performance of rigid polyurethane-polyisocyanurate foams
PublikacjaIn this work, biopolyol obtained from two types of industrial crops’ processing products: crude glycerol and castor oil was used for preparation or rigid polyurethane-polyisocyanurate foams. Bio-based polyol was obtained via crude glycerol polymerization and further condensation of resulting polyglycerol with castor oil. Rigid polyurethane-polyisocyanurate foams were prepared at partial substitution (0–70 wt.%) of petrochemical...
-
Multi-sensor monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in utility water installations
PublikacjaThis paper presents an implementation of the monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in a utility water installation using an automated corrosion monitoring system. Due to the fact that the corrosion inhibitor was added to water intended for human consumption, it was necessary to build a multi-sensor monitoring system. In order to implement corrosion monitoring using a linear...
-
Analysis of causes of crude oil tankers' disasters
PublikacjaW referacie przedstawiono dane statystyczne dotyczące rozlewów ropy surowej oraz opis katastrof tankowców w latach 1999-2003. Zlekceważenie problemów poprawnej eksploatacji wielokrotnie kończy się tragicznie. Z tych powodów wypełniony ropą grecki tankowiec ''Amaragos'' czy też maltańska ''Erika'' złamały się na pół i poszły na dno. Przykładów takich jest więcej. W referacie przedstawiono analizę przyczyn rozlewów olejowych według...
-
Monitoring of underdeck corrosion by using acoustic emission method
PublikacjaThis paper presents first short characteristics of underdeck corrosion process as well as a problem of its monitoring. Next is described an acoustic emission (AE) method elaborated by Department of Ship Technology , Quality Systems and Material Engineering, Gdańsk University of Technology in cooperation with partners of CORFAT project realized within 7th EU Frame Program . Further are presented short characteristics of the emission...
-
Corrosion monitoring as a factor increasing the safety of hydrotechnical infrastructure
PublikacjaWater distribution systems at KGHM S.A. are of great importance for the efficient production of copper and environmental protection. For failures leading to perforation and leakage, the corrosion processes are responsible. This paper aims to assess corrosion on the basis of the analysis of the exposure of the Hydrotechnical Plant pipelines. To this end, the system of transfer and deposition of post-flotation waste as well as the...
-
DETERMINATION OF THE EFFECT OF ENVIRONMENTAL FACTORS ON THE CORROSION OF WATER DISTRIBUTION SYSTEM BASED ON ANALYSIS OF ON-LINE CORROSION MONITORING RESULTS
PublikacjaCorrosion of water distribution system is a significant issue causing problems with quality, safety and continuity of distribution. The changes of corrosion rates of the water distribution systems in Cracow made of carbon steel were investigated by analysis of online corrosion monitoring system results. Corrosion rates were determined using the linear polarization method. The impact of rain, temperatures, conductivity, dissolved...
-
Evaluation of the Commercial Electrochemical Gas Sensors for the Monitoring of CO in Ambient Air
PublikacjaAir pollution is a growing concern of civilized world, which has a significant impact on human health and the environment. Recent studies highlight that the exposure to polluted air can increase the incidence of diseases and deteriorate the quality of life. Hence, it is necessary to develop tools for real-time air quality monitoring. For air pollution monitoring a wide range of stationary gas and particulate analysers can be used....
-
Corrosion process monitoring by AFM higher harmonic imaging
PublikacjaThe atomic force microscope (AFM) was invented in 1986 as an alternative to the scanning tunnelling microscope, which cannot be used in studies of non-conductive materials. Today the AFM is a powerful, versatile and fundamental tool for visualizing and studying the morphology of material surfaces. Moreover, additional information for some materials can be recovered by analysing the AFM's higher cantilever modes when the cantilever...
-
Biodegradability of simulant fluids and crude oil in aquatic environment
PublikacjaBiodegradowalność symulantów płynów była oceniana poprzez pomiar CO2 (EPA 560/6-82-003). Badaniu poddawane były emulsyjne i nieemulsyjne symulanty ropy oraz lekka ropa naftowa typu A z Północnej Ameryki. Uzyskane wyniki wskazują na łatwą biodegradowalność obu symulantów w porównaniu do badanej ropy naftowej.
-
The applicability of low-cost PM10 sensors for atmospheric air quality monitoring
PublikacjaDescribed in this work are the results of field tests carried out in the Tricity Agglomeration between 01 April 2018 and 30 June 2018 in order to evaluate the usefulness of low-cost PM10 sensors in atmospheric air quality monitoring. The results were juxtaposed with the results obtained using reference methods. The results were validated based on the measurement uncertainty as described in...