Filtry
wszystkich: 10110
-
Katalog
- Publikacje 7899 wyników po odfiltrowaniu
- Czasopisma 29 wyników po odfiltrowaniu
- Osoby 66 wyników po odfiltrowaniu
- Projekty 1 wyników po odfiltrowaniu
- Aparatura Badawcza 1 wyników po odfiltrowaniu
- Kursy Online 28 wyników po odfiltrowaniu
- Wydarzenia 5 wyników po odfiltrowaniu
- Dane Badawcze 2081 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: LOW-TEMPERATURE PROPERTIES
-
Assessment of Supercapacitor’s Quality by Means of Low Frequency Noise
PublikacjaLow frequency noise is a well-known tool for quality and reliability assessment of electronic devices. This phenomenon is observed in different electrochemical devices as well (e.g., smart windows, electrochemical corrosion processes). Thus, we can assume that the same tool can be used to asses quality of supercapacitors. Their quality is usually determined only by capacitance and/or equivalent series resistance (ESR), or impedance....
-
Corrosion of evaporator tubes in low emission steam boilers
PublikacjaPurpose of this paper is to reveal the mechanisms of corrosion processes of outer surfaces of low-emission steam boiler evaporator tubes. Examinations were performed to find the reasons of different corrosion susceptibility of tubes situated at combustion chamber on various levels. Examinations were conducted on several segments of 57 x 5.0 mm evaporator tubes made of 16M (16Mo3) steel grade. Segments were taken from level of...
-
PHYSICA E-LOW-DIMENSIONAL SYSTEMS & NANOSTRUCTURES
Czasopisma -
Dedicated power supply subsystem for ultra-low noise preamplifiers
PublikacjaIn field of electronics there is need for low-noise amplifiers. Noise have the most important influence on analog circuits. Therefore exist necessity to develop new ultra-low noise power supplies, which can cooperate with specified amplifiers and preamplifiers. It is very common that professional power supplies are very expensive and still have disadvantages. This paper proposes simple and inexpensive solution, which fulfill specific...
-
Combined analysis of whole human blood parameters by Raman spectroscopy and spectral-domain low-coherence interferometry
PublikacjaIn this article the simultaneous investigation of blood parameters by complementary optical methods, Raman spectroscopy and spectral-domain low-coherence interferometry, is presented. Thus, the mutual relationship between chemical and physical properties may be investigated, because low-coherence interferometry measures optical properties of the investigated object, while Raman spectroscopy gives information about its molecular...
-
Low Power Baseband Processor for M2M Reconfigurable Radio Test Platform
PublikacjaSoftware Defined Radio (SDR) is becoming more andmore frequently used technique for wireless communication. Itfacilitates as fast prototyping and is a versatile method fordeveloping new communication systems. SDR can be realizedbased on high computational capacity platform, where powerconsumption is no a primary concern like i.e. DVB or BTStransmitters. Another trend are low power systems, whereavailable power in reduced and more...
-
Sewage sludge pretreatment by low thermal disintegration for better efficacy of sludge digestion process
PublikacjaThe wastewater water treatment plant (WWTP) sector and it is developing technologies strive to be implement circular economy. The methane production from the sludge digestion process constitute promising source of the renewable energy for WWTP and approaching circular economy assumptions. For this reason, the objective of the study was to examine the modification of sludge characteristics due to the low temperature pretreatment....
-
ASSESSMENT OF VOLATILE ORGANIC COMPOUNDS EMISSIONS FROM RECYCLED LOW-DENSITY POLYETHYLENE STREAMS
PublikacjaThe recycling of plastics is currently one of the most significant industrial challenges. Due to the enormous amounts of plastic wastes generated by various industry branches, it is essential to look for the potential methods of their utilization. Nevertheless, it should not be forgotten that recycled plastics are not pure materials, and they still may show an unfavorable environmental impact. They may contain different contaminants...
-
Properties of LiMnBO3 glasses and nanostructured glass-ceramics
PublikacjaPolycrystalline LiMnBO3 is a promising cathode material for Li-ion batteries. In this work, we investigated the thermal, structural and electrical properties of glassy and nanocrystallized materials having the same chemical composition. The original glass was obtained via a standard melt-quenching method. SEM and 7Li solid-state NMR indicate that it contains a mixture of two distinct glassy phases. The results suggest that the...
-
On the use of a charge balancing method for low energy measurements
PublikacjaThe paper presents the method for the estimation of the energy consumption of the low-power microcontroller-based devices. Due to high dynamics of the changes of the supply current of the tested devices during the operational cycle, the consumed energy estimation is not easy. In order to avoid disadvantages of known methods, the charge balancing method was employed similarly like in some types of A/D converters.
-
SIMPLY AND LOW COAST ELECTROMYOGRAPHY SIGNAL AMPLIFIER
PublikacjaRecently, there has been a noticeable increase in interest in solu tions utilizing electrical signals accompanying muscle activity. Electromyography (EMG) is a technique for recording, analysis and evaluating the electrical activity produced by striated muscle. Its great popularity is due, among other, to the ability to measure with non-invasive electrodes (calle d as sEMG surface electromyography)....
-
Low Frequency Conducted Emissions of Grid Connected Static Converters
PublikacjaPulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....
-
Simple and low-cost wireless voting system
PublikacjaThis paper presents the concept of a simple and low-cost wireless voting system working on the 868 MHz frequency band. Described system is dedicated to general shareholders assemblies but it can be easily adapted for other applications. The main advantage is its simplicity and mobility as it consists solely of three components - voting modules, base station and a PC application from which the whole system is managed. This architecture...
-
Simple and low-cost wireless voting system
PublikacjaThis paper presents the concept of a simple and low-cost wireless voting system working in the 868 MHz frequency band. The described system is dedicated to general shareholders assemblies but it can be easily adapted for other applications. The main advantage is its simplicity and mobility as it consists solely of three components - voting modules, a base station and a PC application from which the whole system is mamaged. This...
-
Low-coherence sensors with nanolayers for biomedical sensing
PublikacjaIn this paper, we describe the fiber optic low-coherence sensors using thin film. We investigated their metrological parameters. Presented sensors were made with the use of standard telecommunication single mode optical fiber (SMF28). Different materials were applied to obtain thick layers, such as boron doped diamond, silver and gold. The thickness of layers used in the experiments ranged from 100 nm to 300 nm. Measurements were...
-
Properties of Nasicon-based CO2 sensors with Bi8Nb2O17 reference electrode
PublikacjaPotentiometric CO2 sensors based on Nasicon (Na+ conductor, Na3Zr2Si2PO12) electrolyte, Bi8Nb2O17/Pt reference electrode and different sensing electrodes have been prepared. Besides the sensing electrode material, sensors differ from each other in the reference electrode preparation technique. The main aim of this study is to investigate sensor construction and electrode fabrication process influence on sensor properties. The optimal...
-
Nitrogen dioxide sensing properties of PEDOT polymer films
PublikacjaThis work presents a simple and fully electrochemical route for the polymerization of poly(3,4-ethylenedioxytiophene) (PEDOT) films for fabricating a NO2 gas sensor prepared by electropolymerization of 3,4-Ethylenedioxythiophene (EDOT) monomer in lithium perchlorate/acetonitrile solution. The main aim of this study is to determine the sensing properties of conductive polymer at elevated temperatures. The effects of the humidity,...
-
High temperature linear impedance of 35P2O5-30Fe2O3-35Nb2O5
Dane BadawczeThe high temperature electrical properties of phosphate-iron glasses containing niobium were investigated. Glass samples of the composition of 35P2O5-30Fe2O3-35Nb2O5 (in %mol) were prepared by the conventional melt quenching technique. Appropriate amounts of reagents ((NH4)2HPO4 (≥99.9%, POCH), Fe2O3 (≥99.9%, POCH), Nb2O5 (≥99.9%, PLUKA AG) and TiO2...
-
Low cost microwave X-band generator
PublikacjaA low cost microwave X-band generator for educational purposes was designed and built. Its simple construction and user's interface makes it suitable for a student laboratory.The generator is based on a single frequency conversion concept. It uses a digitally tunable PLL chip for intermediate frequency generation and an active frequency multiplier for frequency conversion. The generator covers 9,7 - 11 GHz part of the X frequency...
-
ANN for human pose estimation in low resolution depth images
PublikacjaThe paper presents an approach to localize human body joints in 3D coordinates based on a single low resolution depth image. First a framework to generate a database of 80k realistic depth images from a 3D body model is described. Then data preprocessing and normalization procedure, and DNN and MLP artificial neural networks architectures and training are presented. The robustness against camera distance and image noise is analysed....
-
On the low-cost design of abbreviated multisection planar matching transformer
PublikacjaA numerically demanding wideband matching transformer composed of three nonuniform transmission lines (NUTLs) has been designed and optimized at a low computational cost. The computational feasibility of the design has been acquired through the exploitation of low-fidelity NUTL models in most steps of the design procedure and an implicit space mapping optimization engine, providing high accuracy results with only a handful of EM...
-
Enhanced method of DS-CDMA low level singnals detection
PublikacjaThe following article comprises three main parts. The first one generally describes two methods of low level signals detection which are in the interest of this study. The signal spectrum averaging technique is shown as well as the method exploiting averaged spectrum of the signal raised to the power of 2n (nN). Additionally, this section briefly presents proposed enhancements and modifications of these two solutions, which allow...
-
A low-voltage CMOS negative impedance converter for analogue filtering applications
PublikacjaLow-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....
-
Environmental consequences of emulsifying properties of biosurfactant produced by Pseudomonas sp.
PublikacjaBiosurfactants are natural surfactants produced by variety of microorganisms. They are very prospective product due to good biodegradability, low toxicity, good physicochemical properties and high efficiency in many applications. Moreover, they are efficient in wide range of pH, temperatures and salinity. Thus, they have potential to be used in many applications. However, their later presence in municipal and industrial wastewater...
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031832401]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [612073003183971]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031834931]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031835811]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [612073003183841]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031834521]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031835891]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031832721]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031839801]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031835991]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Endometrial stromal sarcoma, low grade - Female, 52 - Tissue image [6120730031837111]
Dane BadawczeThis is the histopathological image of CORPUS UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Low-power device simulator for micro-energy measurement methods testing
PublikacjaThe paper presents low-power device simulator designed for testing of micro-energy measurement methods. Such kind methods can be used for evaluation of power systems based on Energy Harvesting. The device allows to set the current consumption characteristic over the time, thus making possible playing the role of different types of low-power devices e.g. simulating sensor network node.
-
Use of AMI Meters in the Process of Low Voltage Grid Optimization
PublikacjaThis is a report of a project involving, inter alia, low voltage grid performance optimization with data from AMI meters . The study was supported with a European UPGRID grant, and executed by a consortium of companies from seven European countries, including Poland .
-
Low-Reflection Subgridding
PublikacjaArtykuł przedstawia technikę umieszczania makromodeli w trójwymiarowej siatce dyskretyzacji metody różnic skończonych. Umożliwia ona łączenie obszarów siatki o różnym kroku dyskretyzacji. Zastosowana prosta interpolacja liniowa wraz z kolokacją pól sąsiadujących ze sobą podobszarów prowadzi do uzyskania małego współczynnika odbicia od obszaru z gęstą siatką.
-
Low grade serous carcinoma - Female, 45 - Tissue image [4100730020135251]
Dane BadawczeThis is the histopathological image of OVARY tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Low grade serous carcinoma - Female, 45 - Tissue image [4100730020137471]
Dane BadawczeThis is the histopathological image of OVARY tissue sample obtained in University of Warmia and Mazury in Olsztyn and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 1000 slide scanner (20x magnification) and saved to DICOM format.
-
Investigations of the Working Process in a Dual-Fuel Low-Emission Combustion Chamber for an FPSO Gas Turbine Engine
PublikacjaThis investigation is devoted to an analysis of the working process in a dual-fuel low-emission combustion chamber for a floating vessel’s gas turbine. The low-emission gas turbine combustion chamber with partial pre-mixing of fuel and air inside the outer and inner radial-axial swirlers was chosen as the object of research. When modelling processes in a dual-flow low-emission gas turbine combustion chamber, a generalized method...
-
Experimental test of nonclassicality with arbitrarily low detection efficiency
PublikacjaWe theoretically introduce and experimentally demonstrate the realization of a nonclassicality test that allows for arbitrarily low detection efficiency without invoking an extra assumption of independence of the devices. Our test and its implementation is set in a prepare-and-measure scenario with an upper limit on the classical communication capacity of the channel through which the systems are communicated. The essence for our...
-
Corrosion and Cavitation Resistances of Low Alloy Steel After Frictional-Mechanical Treatment
PublikacjaPaper presents the results of the studies of wear, corrosion and cavitation resistances of the S355J2 low alloy medium carbon steel subjected to surface modification by friction-mechanical treatment, as tested in sea water simulated solution. To evaluate the effect of the surface treatment, the comparative studies of the corrosive properties of the steel before and after treatment have been considered. The treatment due to a severe...
-
Low-Cost Automated Design of Compact Branch-Line Couplers
PublikacjaBranch-line couplers (BLCs) are important components of wireless communication systems. Conventional BLCs are often characterized by large footprints which make miniaturization an important prerequisite for their application in modern devices. State-of-the-art approaches to design of compact BLCs are largely based on the use of high-permittivity substrates and multi-layer topologies. Alternative methods involve replacement of transmission-line...
-
Flow Maps and Flow Patterns of R1233zd(E) in a Circular Minichannel at Low, Medium and High Values of Saturation Pressure
PublikacjaThere is a gap in knowledge regarding the flow pattern of low-boiling working fluids in the range of high saturation temperatures (above 120°C) and medium and high reduced pressures (0.5-0.9). Data are present in the literature for similar values of reduced pressures, but for lower values of saturation temperature. This is due to the existing refrigeration applications of these working fluids. At high values of reduced pressure,...
-
Low noise poroelastic road pavements based on modified asphalt binder
PublikacjaTire/road noise is one of the most important environmental problems related to road traffic. As the most effective way to fight noise is reduction of sound emission from the source, a lot of work is being done to improve tire and road surfaces construction. This paper describes the first “road” results obtained within the SEPOR project, which is focused on developing a low noise poroelastic road surface based on bituminous binder....
-
Magneto-thermal convection of low concentration nanofluids
PublikacjaThe main aim of this paper was to analyze possible utilization of the low concentration nanofluids and the magnetic field to enhance heat transfer. The studied fluids were based on water with an addition of copper particles (40-60 nm diameter). They belonged to the diamagnetic group of materials. As a first attempt to stated target the analysis of enclosure placed in the maximal value of square magnetic induction gradient was carried...
-
Reclaiming ground tire rubber at low temperatures: benefits and limitations
PublikacjaLower extrusion temperatures during rubber reclamation lead to a reduction in toxic degradation products and improve the mechanical properties of vulcanizates, at the expense of reduced processability.
-
Novel microstrip low-pass filters with fractal defected ground structures
PublikacjaIn this study, three microstrip low-pass filters (LPFs) containing fractal-shaped defected ground structures have been designed and manufactured. To improve the performance of microstrip LPF, cascades of inductively coupled fractal resonators have been applied. Simultaneously, to achieve relatively constant microstrip impedance resulting in essentially low reflection losses, a modification of the strip geometry has been introduced....
-
Polarisation effects in low-energy positron–molecule scattering
PublikacjaThe UK molecular R-matrix method has been adapted to treat positron collisions from polyatomic targets. A simple empirical enhancement factor which corrects for the underestimation of electron–positron polarisation and correlation effects in the calculations performed with the static-plus-polarization model at low scattering energies is presented. Application of this model to positron scattering from carbon dioxide at energies...