Wyniki wyszukiwania dla: voltage source inverters - MOST Wiedzy

Wyszukiwarka

Wyniki wyszukiwania dla: voltage source inverters

Wyniki wyszukiwania dla: voltage source inverters

  • Dual drive control under SVPWM, experimental results

    Dane Badawcze

    The dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The analysis includes the behaviour of the drive system, examining the dynamic system response to speed and angle changes, and encompassing data...

  • Induction Generator with Direct Control and a Limited Number of Measurements on the Side of the Converter Connected to the Power Grid

    Publikacja

    - ENERGIES - Rok 2022

    The article presents an induction generator connected to the power grid using the AC/DC/AC converter and LCL coupling filter. Three-level inverters were used in the converter, both from the generator side and the power grid side. The algorithm realizing Pulse Width Modulation (PWM) in inverters has been simplified to the maximum. Control of the induction generator was based on the Direct Field-Oriented Control (DFOC) method. At...

    Pełny tekst do pobrania w portalu

  • Optimized Space-Vector Modulation Schemes for Five-Phase Precision Low-Speed Drives with Minimizing the Stator Current Ripple

    Publikacja

    - Rok 2020

    One of the main ways to improve the quality of a precision electric drive is minimization of the stator current pulsations generated by the voltage inverter. The solution of this problem can be achieved by using of multiphase inverters, as well as improving control algorithms. This paper considers the influence of the space-vector modulation algorithm with different switching sequences of basic vectors on the stator current pulsations...

    Pełny tekst do pobrania w portalu

  • EMC disturbances in connection of driving system

    Publikacja

    - Rok 2003

    It is known the steep voltage changes caused by IGBT frequency inverters may cause some electromagnetic problems in driving system. Special dU/dt type as well as sinusoidal filters are used in order to limit the level of the disturbances. The paper presents investigation results of EMC disturbances in inverter supplied induction motor. Experiments have proved that disturbances in current connection differ essentially. Important...

  • Single-Phase 15-Level Switched-Capacitor Boost Multilevel Inverter Topology for Renewable Energy Applications

    Publikacja

    - IEEE Access - Rok 2024

    Galvanic isolation is a vital part of a grid-connected solar PV system. With the growth of multilevel inverters for grid-connected applications, the multilevel inverters having isolation are not sufficiently discussed in the literature. In this paper, a 15-level isolated multilevel inverter topology requiring only thirteen switches is proposed. The envisaged configuration includes two cells, designated as upper and lower cells....

    Pełny tekst do pobrania w portalu

  • Dielectric Barrier Discharge Systems with HV Generators and Discharge Chambers for Surface Treatment and Decontamination of Organic Products

    Publikacja

    - ENERGIES - Rok 2020

    The article presents applications of systems with power electronic converters, high voltage transformers, and discharge chambers used for nonthermal, dielectric barrier discharge plasma treatment of a plastic surface and decontamination of organic loose products. In these installations, the inductance of the high voltage transformers and the capacitances of the electrode sets form resonant circuits that are excited by inverters....

    Pełny tekst do pobrania w portalu

  • Comprehensive distortion compensation of grid-connected inverter currents

    The paper presents a comprehensive approach to the compensation of phase current distortion of grid-connected power inverters. Four different sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, voltage fluctuations in the dc link, time delays in the estimation of grid voltages, and the distortion of inverter output voltages due to dead-time effects and related...

  • THREE-LEVEL F-TYPE INVERTER

    Given the recent available IGBT switch modules up to 6.5 kV, 1200 A rating, the prospect of the diode-free variant topology of the three-level neutral-point-clamped (3-level, T-type) inverter in certain medium voltage applications is bright; due to its small part count and low conduction losses compared to the diode-clamped NPC inverter. However, within this voltage range, the input dc voltage rating of 50% of the switches per...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • NARAŻENIA NAPIĘCIOWE SILNIKÓW INDUKCYJNYCH ZASILANYCH Z FALOWNIKÓW NAPIĘCIA

    Publikacja

    W artykule przedstawiono zagadnienia związane z narażeniami izolacji silników pracujących w układach napędowych z falownikami napięcia. Znaczne stromości napięć oraz zjawiska falowe w przewodach zasilających powodują przyspieszoną degradacje izolacji maszyn. Rozwiązaniem jest stosowanie filtrów biernych na wyjściu falownika.

    Pełny tekst do pobrania w portalu

  • Kompleksowa analiza symulacyjna układu napędowego zespołu trakcyjnego

    Publikacja

    - Czasopismo Techniczne - Rok 2011

    The paper describes an approach to comprehensive analysis of traction electric drive. The drivetrain of ED-74 electric unit equipped with four inverter-fed induction motors was modeled in Matlab/Simulink. The model consists of functional blocks as: motors, inverters, drive controllers, filters. Structure and operation of the model was described. Chosen simulation results were presented and discussed. Two methods of modeling the...

    Pełny tekst do pobrania w portalu

  • Application of Barycentric Coordinates in Space Vector PWM Computations

    Publikacja

    This paper proposes the use of barycentric coordinates in the development and implementationof space-vector pulse-width modulation (SVPWM) methods, especially for inverters with deformed space-vector diagrams. The proposed approach is capable of explicit calculation of vector duty cycles, independentof whether they assume ideal positions or are displaced due to the DC-link voltage imbalance. The use ofbarycentric coordinates also...

    Pełny tekst do pobrania w portalu

  • Prądy łożyskowe w układach napędowych z silnikami indukcyjnymi

    W pracy przedstawiono problemy występujące w układach napędowych z silnikami indukcyjnymi zasilanymi z falownika napięcia. Zwrócono uwagę na rosnącą liczbę uszkodzeń silników w napędach przekształtnikowych. Wskazano przyczyny wynikające z charakteru zasilania przekształtnikowego silnika. Główną uwagę poświęcono prądowi łożyskowemu, który odpowiada za większość awarii maszyn. Przedstawiono rodzaje prądów łożyskowych, wyjaśniając...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Selective Harmonic Elimination PWM For a Cascaded Multi-level Inverter

    Publikacja

    - Rok 2020

    This paper deals with the selective harmonic elimination pulse width modulation (SHE-PWM) technique. This technique is used for the elimination of selected dominant low order harmonics in the multi-level inverter output voltage. The presence of these harmonics is the essential drawback of such kind of inverters; especially when it is used for the control of different AC drivers. The SHE-PWM is based...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Five-phase induction motor drive with sine-wave filter

    Publikacja

    - Rok 2014

    The paper presents closed loop ac drive with 5 phase induction motor operating with voltage source inverter and sine wave filter. The motor supply voltages and currents have sinusoidal shape. For well known adjustable electric drives the field oriented control method with flux and speed co ntrol can be applied. In the presence of output filter both control and estimation algorithms should be modified due to sine wave filter installation....

    Pełny tekst do pobrania w serwisie zewnętrznym

  • BADANIA SYMULACYJNE PROWADZONE W ŚRODOWISKU SYSTEMU EKSPERTOWEGO STOSOWANE DO WSPOMAGANIA PROJEKTOWANIA UKŁADÓW AUTOMATYKI STATKU

    W referacie przedstawiono wykorzystanie badań symulacyjnych jako źródła wiedzy dla systemu ekspertowego. Omawiany system służy wspomaganiu doboru elementów steru strumieniowego. Elementami tego systemu są: biblioteka struktur, biblioteka modeli, baza elementów oraz baza wiedzy. Jako przykład przedstawiono badania symulacyjne struktury steru strumieniowego zawierającej silnik indukcyjny, wał śrubowy, śrubę o skoku nastawnym oraz...

    Pełny tekst do pobrania w portalu

  • Suppression of Supply Current Harmonics of 18-Pulse Diode Rectifier by Series Active Power Filter with LC Coupling

    Publikacja

    - ENERGIES - Rok 2020

    The reported research aims at improving the quality of three-phase rectifier supply currents. An effective method consists of adding properly formed booster voltages to the fundamental supply voltages using a series active filter. In the proposed solution, the booster voltages are generated by three single-phase systems consisting of inverters, LC filters, and single-phase transformers. The application of LC couplings ensures low...

    Pełny tekst do pobrania w portalu

  • Quasi-resonant DC-link voltage inverter with enhanced zero-voltage switching control

    A new topology modification of the parallel quasi-resonant circuit for a dc-link voltage inverter enables regulation of the zero voltage dc-link subperiods and the dc-link voltage gradient settings. The proposed circuit is based on four MOSFET switches with free-wheeling diodes for controlled quasi-resonant recharging between L-C tank in order to assure inverter zero voltage switching (ZVS) conditions. Design optimization of the...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Jednofazowy falownik napięcia z aktywnym obwodem odsprzęgającym

    Znanym zagadnieniem w jednofazowych falownikach napięcia jest pobieranie ze źródła napięcia stałego składowej przemiennej o częstotliwości dwukrotnie większej od częstotliwości generowanej przez falownik. Jednym z rozwiązań problemu jest stosowanie dużej baterii kondensatorów elektrolitycznych, lecz lepszym sposobem z punktu widzenia niezawodności i gęstości mocy przekształtnika jest stosowanie aktywnych układów odsprzęgania mocy....

    Pełny tekst do pobrania w portalu

  • Jarosław Guziński prof. dr hab. inż.

    STOPNIE NAUKOWE 2021 Tytuł profesora nauk inżynieryjno-technicznych. 2012  Stopień doktora habilitowanego nauk technicznych – Wydział Elektrotechniki i Automatyki PG. Rozprawa habilitacyjna „Układy napędowe z silnikami indukcyjnymi i filtrami wyjściowymi falowników. Zagadnienia wybrane”. Kolokwium i nadanie stopnia doktora habilitowanego 29 maja 2012 r. Monografia uzyskała nagrodę naukową Wydziału IV Nauk Technicznych Polskiej...

  • PROJEKT ZESPOŁOWY [DK][2023/24]

    Kursy Online
    • D. Karkosiński

    CCCLECTURE and Classes: Power supply systems for industrial facilities. Devices and main circuits of MV power stations. Short-circuit calculation. Power protection automation. Security classification according to American ANSI standards used in the EU. Microprocessor protection relays. Drive systems for medium power and medium voltage pumps. Roving inverters. PROJECT: Design of a MV switching station for a medium-power pumping...

  • PROJEKT ZESPOŁOWY [ET][DK][2024/25]

    Kursy Online
    • D. Karkosiński

    CCCLECTURE and Classes: Power supply systems for industrial facilities. Devices and main circuits of MV power stations. Short-circuit calculation. Power protection automation. Security classification according to American ANSI standards used in the EU. Microprocessor protection relays. Drive systems for medium power and medium voltage pumps. Roving inverters. PROJECT: Design of a MV switching station for a medium-power pumping...

  • Source

    Czasopisma

    ISSN: 1712-9125

  • development of an open source software to transform acoustic data for classification of benthic habitat

    Publikacja

    - HYDROACOUSTICS - Rok 2007

    .

    Pełny tekst do pobrania w portalu

  • Destructive impact of PWM inverters on traction AC motors

    Publikacja

    - ELECTROMOTION - Rok 2010

    The electric traction drives with an AC motor fed by a frequency converter are used more and more often nowadays. The most significant side effects, of a converter's output voltage forming PWM method for AC motor windings, are steep voltage changes, which can initiate several destructive phenomena. The paper presents the adverse influence of a converter common mode voltage on the motor windings's increased voltage exposure and...

  • Voltage Conditions in Low Voltage Grid with Connected Mictogeneration

    Publikacja

    The introduction of distributed generation into a low voltage grid may cause voltage problems in it. The paper discusses the effect of microgeneration on voltage levels in a low voltage grid. A real low voltage grid of considerable length was selected for the analysis. The grid primarily supplies residential buildings in a rural area. Results of tests that consider potential measures which could be applied in this grid to improve...

    Pełny tekst do pobrania w portalu

  • A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor

    Publikacja

    - Elektronika Ir Elektrotechnika - Rok 2020

    This article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....

    Pełny tekst do pobrania w portalu

  • Voltage Transients Transfer over Medium Voltage Instrument Transformers

    Publikacja

    - Rok 2011

    This paper presents voltage harmonic transfer accuracy problems through voltage transformers which are used in power quality monitoring systems in medium and high voltage grids. A simplified lumped parameters circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number voltage transformers typically used in medium voltage grid has been tested in the conducted disturbances...

  • Voltage Harmonics Transfer through Medium Voltage Instrument Transformers

    Publikacja

    Voltage transformers are widely used in power quality monitoring systems in medium and high voltage grids. This paper presents accuracy problems related to voltage harmonics transfer through instrument transformers. A simplified lumped-parameters wideband circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number of voltage transformers have been tested in the frequency...

    Pełny tekst do pobrania w portalu

  • Synteza bezczujnikowego sterowania maszyną indukcyjną klatkową zasilaną z falownika prądu

    Publikacja

    - Rok 2016

    Synteza bezczujnikowego sterowania maszyną indukcyjną klatkową zasilaną z falownika prądu stanowi cel niniejszej monografii. Praca zawiera podstawowe informacje na temat modelowania układu napędowego z maszyną indukcyjną klatkową zasilaną z falownika prądu. Przedstawiono informacje na temat linearyzacji nieliniowych obiektów. Na pod-stawie metody syntezy strukturalnej opracowano nowe transformacje do postaci zmien-nych multiskalarnych,...

  • Problems with microprocessor voltage-to-frequency and frequency-to-voltage converters implementation

    The article presents the problems of digital voltage-to-frequency and frequency-to-voltage processing. Transducer systems implemented in microprocessor technology are presented, the timing of signals and functioning algorithms are discussed. An analysis of processing errors has been performed and the results of experimental studies of realized systems are presented.

    Pełny tekst do pobrania w portalu

  • Improving voltage levels in low-voltage networks with distributed generation – case study

    Publikacja

    - Rok 2018

    The use of distributed generation in low-voltage networks may cause the voltage variation in them, within the wide range. In unfavourable circumstances, the voltage may reach unacceptable values. The paper presents the effect of distributed generation on voltage levels in a selected low-voltage rural distribution network in Poland. An analysis of possible methods for improving voltage levels in this network is conducted. The most...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Long-term measurements from a photovoltaic power plant and meteorological stations at the Laboratory LINTE^2 of Gdańsk University of Technology

    Dane Badawcze

    1)    The Laboratory LINTE^2 is a large research infrastructure operated by the Faculty of Electrical and Control Engineering at Gdańsk University of Technology, to be found in Gdańsk, Poland (54.3690 N, 18.6130 E). 2)    The measurements have been collected from a photovoltaic power plant located on the roof of the laboratory, having total capacity...

  • Source (www.source.ie)

    Czasopisma

    ISSN: 1369-2224

  • Static Series and Shunt-series PE Voltage-quality Controllers

    Publikacja

    - Rok 2007

    As presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Experimental test results of an automatic voltage regulator with independent phase voltage controllers

    The growing number of distributed renewable energy sources and dynamic constant-power loads (e.g. electric vehicle charging stations) pose new challenges for network operators. These changes result in alterations to network load profiles and load flows, leading to greater voltage volatility. One effective solution to these problems can be the use of automatic voltage regulators (AVRs), which stabilize and symmetrize voltage output,...

    Pełny tekst do pobrania w portalu

  • Voltage variations and their reduction in a rural low-voltage network with PV sources of energy

    Publikacja

    - Electronics - Rok 2021

    Renewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...

    Pełny tekst do pobrania w portalu

  • The Impact of Micro-Sources on Voltage Distortions in a Power Grid

    Publikacja

    The increase in the number of photovoltaic (PV) systems integrated with low voltage (LV) grids has led to a great need to analyse the impact of these systems on the quality of electricity and the reliability of its supply. This paper presents and compares the energy quality requirements imposed by various countries on photovoltaic plants. Then, based on real object tests and simulation in DIgSILENT PowerFactory, the impact has...

    Pełny tekst do pobrania w portalu

  • Voltage Dependence of Supercapacitor Capacitance

    Publikacja
    • A. Szewczyk
    • J. Sikula
    • V. Sedlakova
    • J. Majzner
    • P. Sedlak
    • T. Kuparowitz

    - Metrology and Measurement Systems - Rok 2016

    Electronic Double-Layer Capacitors (EDLC), called Supercapacitors (SC), are electronic devices that are capable to store a relatively high amount of energy in a small volume comparing to other types of capacitors. They are composed of an activated carbon layer and electrolyte solution. The charge is stored on electrodes, forming the Helmholtz layer, and in electrolyte. The capacitance of supercapacitor is voltage- dependent. We...

    Pełny tekst do pobrania w portalu

  • Voltage control in a power system with renewable sources of energy

    Publikacja

    - Rok 2019

    Intensive development of distributed generation in power systems, caused by the European Union energy policy, gives possibility for improving safety in power delivery as well as optimizing the costs of the systems functioning. In this context, distributed generation can be used for voltage control in power systems – it can be performed by the control of reactive power of each source of energy or a group of energy sources. This...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Voltage profiles improvement in a power network with PV energy sources – results of a voltage regulator implementation

    Publikacja
    • A. Szultka
    • S. Szultka
    • S. Czapp
    • R. Karolak
    • M. Andrzejewski
    • J. Kapitaniak
    • M. Kulling
    • J. Bonk

    - ENERGIES - Rok 2022

    The constant increase in the number of photovoltaic (PV) energy sources in distribution networks is the cause of serious voltage problems. The networks built at least a dozen years ago are not provided for the installation of a large number of micro-sources. It happens that the previously properly functioning power networks are not able to provide to consumers power with the required parameters, after installing many PV sources....

    Pełny tekst do pobrania w portalu

  • Optimal Multivariable Control for Modified Z-source Based IPT

    Publikacja

    - Rok 2018

    This paper describes Z-source based inductive power transfer topologies control approaches. The goal of this work is a multi-variable control approach which involves a constant voltage/constant current control along with an optimal frequency control to obtain maximum efficiency. This control is applied to the wireless power transfer system based on a modified Z-source topology. The description of the control method along with simulation...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Medium voltage drives - challenges and requirements

    Publikacja

    - Rok 2010

    The design and application of medium voltage (MV) drives are associated with different requirements related to the line side and motor side of the drive. This paper presents a brief review of the existing challenges and requirements for employing medium voltage drives in various industries. Line side, motor side, and converterproblems and requirements are described. The aim of the paper is to review the existing problems to allow...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Multilevel inverter neutral-point voltage sensor diagnostic based on the Extended Kalman Filter

    Publikacja

    A new algorithm for neutral point voltage imbalance estimation in DC link of the three-level (3L) neutral point clamped (NPC) voltage source inverter (VSI) is proposed. Application of the proposed algorithm does not require any additional sensors. The unbalanced voltage calculation is based on the information derived from the inverter output measured currents and from the knowledge of the load model parameters. In order to estimate...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Three-Level Z-Source Neutral-Point-Clamped Inverter

    Publikacja

    - Rok 2006

    The paper describes construction and the principles of activity, attributes and potential of 3-phase Z-type inverters. The paper focuses on the basic system and suggested 3-level system of a NPC type Z-inverter, which was elaborated by authors. Simplified theoretical analysis of both systems has been verified by detailed simulation research. In the last section of the article, the possibility to build multilevel Z- inverters based...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • A Single-Carrier-Based Pulse-Width Modulation Template for Cascaded H-Bridge Multilevel Inverters

    Publikacja

    - IEEE Access - Rok 2021

    Multiplicity of the triangular carrier signals is a criterion for the extension of sinusoidal pulsewidth modulation, SPWM, to a number of output voltage levels per phase-leg in cascaded H-bridge (CHB) multilevel inverter (MLI). Considering medium and high voltage applications where appreciable number of output voltage levels from CHB MLI is needed, commensurate high number of carrier signals in either classical level- or phase-shifted...

    Pełny tekst do pobrania w portalu

  • Static Shunt PE Voltage-Quality Controllers

    Publikacja

    - Rok 2007

    This chapter focuses on power electronics (PE)-based solutions used in distribution networks for reduction of supply-voltage-quality deterioration, from long interruptions to the harmonics. Various PE devices and their combinations are addressed for particular or a range of voltage disturbances. A particular solution is applied taking into account demands for voltage quality and network configuration. In general, there are three...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Supercapacitors - charge redistribution and restoring voltage

    Publikacja

    - Rok 2014

    The charge in supercapacitor is stored on electrodes and in electrolyte. The charges on electrodes create the Helmholtz double layer which is formed immediately with time constant of the order of seconds, while the charge storage in electrolyte is going on with time constant of the order of hundreds seconds. When the charged supercapacitor is shorted for few seconds, the charge from electrodes is discharged while the charge in...

  • Joint Commission: The Source

    Czasopisma

    ISSN: 1542-8672

  • Sensorless Control of Induction Machine Supplied by Current Source Inverter

    Publikacja

    The paper describes the voltage control technique of induction machines supplied by a current source inverter. The control system is based on proposed new multi-scalar variables, which are named “r.” The control system contains the output filter capacitor's model. In the sensorless control system the Z type backstepping speed observer was applied. The mathematical dependences are confirmed by simulation and experimental research.

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Voltage and frequency regulation of a standalone induction generator by reduced-rating power electronic compensators - comparative evaluation

    Publikacja

    - Rok 2015

    In this paper are considered two fundamental topologies of power electronic compensators for voltage and frequency control of a standalone self-excited induction generator (IG) system. These are voltage and current source inverter based shunt compensators with energy storage. The aim of this study is to assess main features of both topologies in dynamic and steady-state IG operation. The whole system is modelled with the aid of...