Wyniki wyszukiwania dla: LOW-VOLTAGE NETWORK - MOST Wiedzy

Wyszukiwarka

Wyniki wyszukiwania dla: LOW-VOLTAGE NETWORK

Wyniki wyszukiwania dla: LOW-VOLTAGE NETWORK

  • Quasi-resonant DC-link voltage inverter with enhanced zero-voltage switching control

    A new topology modification of the parallel quasi-resonant circuit for a dc-link voltage inverter enables regulation of the zero voltage dc-link subperiods and the dc-link voltage gradient settings. The proposed circuit is based on four MOSFET switches with free-wheeling diodes for controlled quasi-resonant recharging between L-C tank in order to assure inverter zero voltage switching (ZVS) conditions. Design optimization of the...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Intelligent turbogenerator controller based on artifical neural network

    The paper presents a desing of an intelligent controller based on neural network (ICNN). The ICNN ensures at the same time two fundamental functions : the maintaining of generator voltage at the desired value and the damping of the electromechanical oscillations. Its performance is evaluted on a single machine infinite bus power system through computer simulations. The dynamic and transient operation of the proposed controller...

    Pełny tekst do pobrania w portalu

  • Modified Inductive Multi-Coil Wireless Power Transfer Approach Based On Z-Source Network

    Publikacja

    - IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS - Rok 2021

    This article presents a non-conventional approach to a multi-coil wireless power transfer system based on a Z-source network. The novelty of the approach lies in the use of a Z-source as a voltage source for energy transmission through the wireless power transfer coils. The main advantage is in a reduced number of semiconductors. This paper provides the design approach, simulation and experimental study. Feasibility and possible...

    Pełny tekst do pobrania w portalu

  • Selection of optimal location and rated power of capacitor banks in distribution network using genetic algorithm

    Publikacja

    In this paper, the problem of placement and rated power of capacitor banks in the Distribution Network (DN) is considered. We try to suggest the best places for installing capacitor banks and define their reactive power. The considered formulation requires the optimization of the cost of two different objectives. Therefore the use of properly multiobjective heuristic optimization methods is desirable. To solve this problem we use...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Problems with microprocessor voltage-to-frequency and frequency-to-voltage converters implementation

    The article presents the problems of digital voltage-to-frequency and frequency-to-voltage processing. Transducer systems implemented in microprocessor technology are presented, the timing of signals and functioning algorithms are discussed. An analysis of processing errors has been performed and the results of experimental studies of realized systems are presented.

    Pełny tekst do pobrania w portalu

  • Niskonapięciowy filtr analogowy CMOS wykorzystujący konwerter ujemnoimpedancyjny

    A low-voltage 3-order low-pass CMOS filter based on the novel current inversion type negative impedance converter (CNIC) is presented. It shows a badwidth of 10 MHz at 400 uW power consumption and 2 V supply voltage when realized in a 0.35 um CMOS process.

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Niskonapięciowy filtr analogowy CMOS oparty o konwerter ujemno-impedancyjny

    Publikacja

    - Rok 2008

    A low-voltage 3-order low-pass CMOS filter based on the novel current inversion type negative impedance converter (CNIC) is presented. It shows a badwidth of 10 MHz at 400 uW power consumption and 2 V supply voltage when realized in a 0.35 um CMOS process.

  • Photovoltaic effect in the single-junction DBP/PTCBI organic system under low intensity of monochromatic light

    Photoelectric properties of the planar ITO/MoO3/DBP/PTCBI/BCP/Ag system were characterized on the basis of short-circuit current, open-circuit voltage and absorption spectra, and current-voltage measurements in the dark and under monochromatic illumination of low intensity. Photovoltaic performance of the system was compared with the performance of ideal semiconductor and excitonic cells of chosen bandgaps. Such analysis shows,...

    Pełny tekst do pobrania w portalu

  • Static Series and Shunt-series PE Voltage-quality Controllers

    Publikacja

    - Rok 2007

    As presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Estimation of the uncertainty of the AC/AC transducer output voltage

    The paper presents a methodology for estimating uncertainty of voltage transducers processing function, on the example of CYVS411D07 voltage transducers. The analysis was conducted using the method based on the GUM Guide propagation of uncertainty law and the determination of the coverage factor based on the effective number of degrees of freedom (t-Student distribution). The paper also presents example evaluation results of measured...

    Pełny tekst do pobrania w portalu

  • Analysis of energy efficiency of suburban railway transport network

    Publikacja

    Rising numbers of agglomeration residents cause increased need for people movement on daily basis. Because of congestion of local roads, air pollution and limited parking space, providing mass transit based on electric traction is reasonable. While the electric rail vehicles are considered highly efficient in themselves, they need to be analyzed as a part of a transport network, because energy consumption depends on operating conditions...

    Pełny tekst do pobrania w portalu

  • Activity coordination of capacitor banks and power transformer controllers in order to reduce power losses in the MV grid

    Publikacja

    One of the main issues related to the optimization of the MV (middle voltage) network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility...

  • Low cost set-up for supercapacitors parameters evaluation

    Supercapacitors are capable to store relatively high amount of energy comparing to its mass. Growing number of these devices applications requires development of new testing methods. Standard methods of evaluation of supercapacitor parameters, as cycling voltammetry, CV, galvanostatic cycling with potential limitation, GCPL, impedance measurements, require equipment of high cost...

    Pełny tekst do pobrania w portalu

  • Multi-pulse VSC arrangements with coupled reactors

    Publikacja

    - Rok 2016

    This paper presents a novel approach to the multipulse VSC (Voltage Source Converter) arrangements based on several conventional inverter modules connected in parallel by using coupled reactors. This solution reduces the THD of the output voltage, despite the low switching frequency of transistors. The advantage of the proposed solution is also a relatively small rated power of the reactors. Proposed new arrangements for different...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Low speed permanent magnet synchronous generator for vertical axis wind turbine

    Publikacja

    The paper presents design process and tests of a prototype low speed permanent magnet synchronous generator (PMSG) dedicated for the innovative vertical-axis wind turbine. The rated data of the designed generator are following: power - 15 kVA, voltage - 400 V (Y), rotation speed - 93.75 rpm. The design assumptions, chosen results of the design process and experimental tests of the prototype PMSG are presented. The considered PMSG...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Harmonics produced by traction substations – computer modelling and experimental verification

    Voltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion include traction rectifiers. This paper presents results of the computer investigation of...

    Pełny tekst do pobrania w portalu

  • Analysis of electromagnetic disturbances in DC network of grid connected building-integrated photovoltaic system

    Publikacja

    - Rok 2015

    This paper focuses on conducted electromagnetic interference (EMI) emissions and propagation in the DC network of grid connected building integrated photovoltaic (PV) system. The investigated PV system, consists of ten solar panels, cabling and the grid-connected one phase inverter. The EMI simulation model of the real PV system has been developed with the aid of impedance analyzer measurements of solar panels and the DC network...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Voltage Harmonic Distortion Measurement Issue in Smart-Grid Distribution System

    Publikacja

    - Rok 2012

    This paper presents the investigation results ofvoltage harmonic transfer accuracy problems through voltagetransformers which are widely used in power quality monitoringsystems in medium and high voltage grids. A simplified lumpedparameters circuit model of the voltage transformer is presentedand verified by simulation and experimental investigations. Anumber voltage transformers typically used in medium voltagegrid has been tested...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Ladder-Based Synthesis and Design of Low-Frequency Buffer-Based CMOS Filters

    Buffer-based CMOS filters are maximally simplified circuits containing as few transistors as possible. Their applications, among others, include nano to micro watt biomedical sensors that process physiological signals of frequencies from 0.01 Hz to about 3 kHz. The order of a buffer-based filter is not greater than two. Hence, to obtain higher-order filters, a cascade of second-order filters is constructed. In this paper, a more...

    Pełny tekst do pobrania w portalu

  • Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current

    Publikacja

    A novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Distribution Transformer with Multi-Zone Voltage Regulation for Smart Grid System Application

    Publikacja

    - Rok 2019

    The article presents four concepts of the multi-zone voltage regulation (MZVR) system. It is a combination of a distribution transformer with an on-load tap-changer, for step voltage regulation, and a power electronic converter, dimensioned for a fraction of MZVR power, realizing continuous voltage regulation, supplemented by a special switch, the so-called bypass. This allows voltage regulation at high resolution, wide range and...

    Pełny tekst do pobrania w portalu

  • Response of high voltage disconnector under seismic excitation - experimental and numerical study

    Publikacja

    The efficiency of the energetic infrastructure system is a very import safety issue in the region experienced by the ground motion. The aim of the present paper is to show the results of the experimental and numerical study focused on the earthquake-induced response of the high voltage disconnector, which is an important element of energetic network. First, the impact tests as well as the sweep-sine shaking table tests were conducted....

  • Research on the Flicker Effect in Modern Light Sources Powered by an Electrical Network

    Publikacja

    - ENERGIES - Rok 2024

    Disruptions in power quality have a negative impact on many energy consumers. These include lighting, where interference manifests itself, among others, in the form of light flickering. The article presents phenomena accompanying the operation of modern light sources against the background of exemplary results of studies on the flicker of conventional light sources, such as incandescent or fluorescent lamps. The flickering effect...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Dynamic variables limitation for backstepping control of induction machine and voltage source converter

    Dynamic variables limitation for backstepping control of induction machine and voltage source converter The paper presents the method of control of an induction squirrel-cage machine supplied by a voltage source converter. The presented idea is based on an innovative method of the voltage source converter control, consisting in direct joining of the motor control system with the voltage source rectifier control system. The combined...

    Pełny tekst do pobrania w portalu

  • Multilevel inverter neutral-point voltage sensor diagnostic based on the Extended Kalman Filter

    Publikacja

    A new algorithm for neutral point voltage imbalance estimation in DC link of the three-level (3L) neutral point clamped (NPC) voltage source inverter (VSI) is proposed. Application of the proposed algorithm does not require any additional sensors. The unbalanced voltage calculation is based on the information derived from the inverter output measured currents and from the knowledge of the load model parameters. In order to estimate...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Assessment of Fuel Cells’ State of Health by Low-Frequency Noise Measurements

    We proposed applying low-frequency (flicker) noise in proton-exchange membrane fuel cells under selected loads to assess their state of health. The measurement set-up comprised a precise data acquisition board and was able to record the DC voltage and its random component at the output. The set-up estimated the voltage noise power spectral density at frequencies up to a few hundred mHz. We observed the evolution of the electrical...

    Pełny tekst do pobrania w portalu

  • A 1-nS 1-V Sub-1-µW Linear CMOS OTA with Rail-to-Rail Input for Hz-Band Sensory Interfaces

    The paper presents an operational transconductance amplifier (OTA) with low transconductance (0.62–6.28 nS) and low power consumption (28–270 nW) for the low-frequency analog front-ends in biomedical sensor interfaces. The proposed OTA implements an innovative, highly linear voltage-to-current converter based on the channel-length-modulation effect, which can be rail-to-rail driven. At 1-V supply and 1-Vpp asymmetrical input driving,...

    Pełny tekst do pobrania w portalu

  • Medium voltage drives - challenges and requirements

    Publikacja

    - Rok 2010

    The design and application of medium voltage (MV) drives are associated with different requirements related to the line side and motor side of the drive. This paper presents a brief review of the existing challenges and requirements for employing medium voltage drives in various industries. Line side, motor side, and converterproblems and requirements are described. The aim of the paper is to review the existing problems to allow...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • DC-link voltage balancing in cascaded H-Bridge converters

    In the paper a DC-link voltage balancing strategy for multilevel Cascaded H-Bridge (CHB) converter is proposed. Presented solution bases on optimal choice of active vector durations in Space-Vector Pulse Width Modulation (SV-PWM). It makes it possible to DC-link voltages control and to properly generate the output voltage vector in the case of DC-link voltage unbalance. Results of simulation and experimental researches...

    Pełny tekst do pobrania w portalu

  • Optimized Space Vector Modulation strategy for five phase voltage source inverter with third harmonic injection

    This paper presents a simple and an effective SVM algorithm for five-phase Voltage-Source Inverters with the possibility to control independently the voltage vectors for fundamental and auxiliary orthogonal subspaces. The essential benefit is that output voltage is generated using only four active voltage vectors with limited numbers of switching. In the proposed solution, four active vectors are arbitrary chosen, independent of...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Light-Powered Starter for Micro-Power Boost DC–DC Converter for CMOS Image Sensors

    The design of a starter for a low-voltage, micro-power boost DC–DC converter intended for powering CMOS image sensors is presented. A unique feature of the starter is extremely low current, below 1 nA, supplying its control circuit. Therefore, a high-voltage (1.3 V) configuration of series-connected photovoltaic diodes available in a standard CMOS process or a small external LED working in photovoltaic mode can be used as an auxiliary...

    Pełny tekst do pobrania w portalu

  • THE PHASE SHIFTERS INFLUENCE ON THE POWER SYSTEM STABILITY

    Publikacja

    The paper presents the effect of phase shifters as FACTS devices on the possibility of improving the angle stability. Presented results obtained by the dynamic simulation performed on the mathematical model of the three machine system cooperating with the 400 kV network. The generative blocks models include turbine models with their controllers and models of synchronous generators with their excitation systems and voltage regulation....

  • Higher harmonics produced by traction substations – computer modelling and experimental verification

    Voltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers, although the rms value of load current does not exceed their current-carrying capacity. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Voltage Source Power Line Conditioner for Applications in Local Supply Systems

    Publikacja

    - Rok 2019

    The paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...

    Pełny tekst do pobrania w portalu

  • CM Voltage Compensators for Power Electronic Interfaces

    Publikacja
    • R. Smoleński
    • J. Bojarski
    • P. Leżyński
    • A. Kempski
    • J. Łuszcz

    - IEEE Electromagnetic Compatibility Magazine - Rok 2015

    The experimental results presented in the paper have shown that the application of the PEIs might cause EMC related problems, especially in the case of the application of a group of connected converters. The most convenient way to reduce EMI currents and prevent aggregation of EMI currents introduced by a group of converters is through passive compensation of voltage interference sources inside of the single converters. In the...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • A method of self-testing of analog circuits based on fully differential op-amps with theTCBF classifier

    Publikacja

    - Rok 2015

    A new approach of self-testing of analog circuits based on fully differential op-amps of mixed-signal systems controlled by microcontrollers is presented. It consists of a measurement procedure and a fault diagnosis procedure. We measure voltage samples of a time response of a tested circuit on a stimulation of a unit step function given at the common-mode reference voltage input of the op-amp. The fault detection and fault localization...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • THREE-LEVEL F-TYPE INVERTER

    Given the recent available IGBT switch modules up to 6.5 kV, 1200 A rating, the prospect of the diode-free variant topology of the three-level neutral-point-clamped (3-level, T-type) inverter in certain medium voltage applications is bright; due to its small part count and low conduction losses compared to the diode-clamped NPC inverter. However, within this voltage range, the input dc voltage rating of 50% of the switches per...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Reducing common mode voltage and bearing currents in quasi - resonant DC - link inverter

    In the paper, a concept of separation of an inverter-fed induction motor drive from its mains supply by two transistor switches inserted in the dc-link circuit is reexamined based on the proposed parallel quasi-resonant dc-link inverter (PQRDCLI). The objective of the paper is to show an advantage of the proposed topology in limiting high frequency common mode voltage and bearing currents. In the laboratory setup, an induction...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Fully Tunable Analog Biquadratic Filter for Low-Power Auditory Signal Processing in CMOS Technologies

    Publikacja

    A novel Gm-C structure of a second-order continuous-time filter is proposed that allows for the independent control of the filter’s natural frequency (ω0) and quality factor (Q). The structure consists of two capacitors and four transconductors. Two transconductors together with the capacitors form a lossless second-order circuit with tunable ω0. The other two transconductors form a variable gain amplifier (VGA) which realizes...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Voltage control in a power system with renewable sources of energy

    Publikacja

    - Rok 2019

    Intensive development of distributed generation in power systems, caused by the European Union energy policy, gives possibility for improving safety in power delivery as well as optimizing the costs of the systems functioning. In this context, distributed generation can be used for voltage control in power systems – it can be performed by the control of reactive power of each source of energy or a group of energy sources. This...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Study of Nanohydroxyapatite Coatings Prepared by the Electrophoretic Deposition Method at Various Voltage and Time Parameters

    Publikacja

    The aim of the work is to compare the properties of nanohydroxyapatite coatings obtained using the electrophoretic deposition method (EDP) at 10 V, 20 V, and 30 V, and with deposit times of 2 and 5 min. The primary sedimentation was used to minimize the risk of the formation of particle agglomerates on the sample surface. Evaluation of the coating was performed by using a Scanning Electron Microscope (SEM), Energy-Dispersive Spectroscopy...

    Pełny tekst do pobrania w portalu

  • A Review of Reduction Methods of Impact of Common-Mode Voltage on Electric Drives.

    Publikacja

    In this survey paper, typical solutions that focus on the reduction in negative effects resulting from the common-mode voltage influence in AC motor drive applications are re-examined. The critical effectiveness evaluation of the considered methods is based on experimental results of tests performed in a laboratory setup with an induction machine fed by an inverter. The capacity of a common-mode voltage level reduction and voltage...

    Pełny tekst do pobrania w portalu

  • Four level inverter's DC bus voltage balancing with 3-terminal DAB converter

    Publikacja

    - Rok 2016

    —Multilevel inverters become more and more popular, especially in the medium or high voltage and high power applications. Unfortunately, some of inverter topologies require additional DC bus voltage balancing systems. This paper presents a novel approach to such systems, which is based on a multiple terminal DAB converter. Along with the voltage balancing function the proposed solution enables the connection of energy storage devices...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • AC Motor Voltage and Audible Noise Dataset

    Publikacja

    - Rok 2022

    The dataset titled AC motor voltage and audible noise waveforms in ship’s electrical drive systems with frequency converters contains the voltage and sound measurement results recorded in a marine frequency controlled AC drive system. The dataset is part of research focussing on the impact of the ship’s electrical drive systems with frequency converters on vibrations and the level of audible noise on ships. The dataset allows the...

    Pełny tekst do pobrania w portalu

  • Control strategies and comparison of the Dynamic Voltage Restorer

    Publikacja

    - Rok 2008

    This paper focuses on a selection problems of mitigation of the voltage disturbance by of the Dynamic Voltage Restorers (DVR’s). In short form presented and discussed are the basis of different control strategies of the DVR. The main emphasis is placed on application of modern power electronic devices. Authors of this paper in particular occupy oneself with analysis of the power rating of the typically DVR topologies. These problems...

    Pełny tekst do pobrania w serwisie zewnętrznym

  • Fractional-order Systems and Synchronous Generator Voltage Regulator

    Publikacja

    - Acta Energetica - Rok 2015

    Modern regulators of synchronous generators, including voltage regulators, are digital systems, in their vast majority with standard structures contained in the IEEE standard. These are systems described with stationary differential equations of integral order. Differential equations of fractional order are not employed in regulators for synchronous generator control. This paper presents an analysis of the possibilities of using...

    Pełny tekst do pobrania w portalu

  • Unidirectional DC/DC Converter with Voltage Inverter for Fast Charging of Electric Vehicle Batteries

    Publikacja

    - ENERGIES - Rok 2020

    The paper proposes the adaptation of the industrial plant’s power network to supply electric vehicle (EV) fast-charging converters (above 300 kW) using renewable energy sources (RESs). A 600 V DC microgrid was used to supply energy from RESs for the needs of variable speed motor drives and charging of EV batteries. It has been shown that it is possible to support the supply of drive voltage frequency converters (VFCs) and charging...

    Pełny tekst do pobrania w portalu

  • THE INFLUENCE OF PHASE SHIFTERS ON THE VOLTAGE STABILITY OF CONNECTED POWER SYSTEMS

    Publikacja

    The paper presents the results of simulation tests of connected power systems in which phase shifters were installed on cross-border links. The analysis was carried out in terms of assessing the impact of shifters on node voltage stability. Individual systems were characterized by different balance of active power: deficit or excess. The evaluation of voltage stability was based on the dU/dQ and dU/dP criteria.

  • Analysis of Ferroresonance Mitigation Effectiveness in Auxiliary Power Systems of High-Voltage Substations

    Publikacja
    • R. Tarko
    • W. Nowak
    • J. Gajdzica
    • S. Czapp

    - ENERGIES - Rok 2024

    Ferroresonance in power networks is a dangerous phenomenon, which may result in overcurrents and overvoltages, causing damage to power equipment and the faulty operation of protection systems. For this reason, the possibility of the occurrence of ferroresonance has to be identified, and adequate methods need to be incorporated to eliminate or reduce its effects. The aim of this paper is to evaluate the effectiveness of ferroresonance...

    Pełny tekst do pobrania w portalu

  • Supercapacitors - charge redistribution and restoring voltage

    Publikacja

    - Rok 2014

    The charge in supercapacitor is stored on electrodes and in electrolyte. The charges on electrodes create the Helmholtz double layer which is formed immediately with time constant of the order of seconds, while the charge storage in electrolyte is going on with time constant of the order of hundreds seconds. When the charged supercapacitor is shorted for few seconds, the charge from electrodes is discharged while the charge in...