Testing an evaporator operation with a concave manifold, condenser temperature 30, evaporator temperature 70 and preheater temperature 60
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a concave manifold, condenser temperature 30, evaporator temperature 70 and preheater temperature 40
Dane BadawczeThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on "unknown" object using 2-wire probe
Dane BadawczeThe dataset presents impedance spectrum of "black-box" object with interesting phase characteristics. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Reliability of acicular grindable thermocouples for transient temperature measurements at sliding contacts
PublikacjaAcicular grindable thermocouples represent an interesting and prospective technique of temperature measurements at sliding contacts. This study aimed at the investigation of their reliability and accuracy as applied to the friction materials of various classes in contact with steel. The tests were conducted on a pin-on-disc tribometer under stationary and transient regimes. The experimental results were validated by comparing the...
-
Jakub Konkol dr inż.
Osoby -
Kurs mobilny
Kursy OnlineSample course for iOS features testing.
-
Andrzej Chybicki dr inż.
OsobyZ wykształcenia informatyk, absolwent Wydziału Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej, doktor nauk technicznych w dziedzinie informatyka specjalizujący się w przetwarzaniau danych przestrzennych w rozproszonych systemach informatycznych. Ukierunkowany na wykorzystywanie osiągnięć i wiedzy zakresu prowadzonych badań w przemyśle. Współpracował z szeregiem podmiotów przemysłu informatycznego, geodezyjnego...
-
Planowanie badań doświadczalnych,Wykład,IMM II st,letni 2023-2024 (PG_00057484)
Kursy OnlineCelem przedmiotu jest zaprezentowanie metod stosowanych do planowania badań doświadczalnych oraz opracowania wyników tych badań The aim of the subject is to present methods used to plan experimental testing and elaborate the results of the testing
-
Performance of acicular grindable thermocouples for temperature measurements at sliding contacts
PublikacjaThe present study investigates the performance of acicular grindable thermocouples based on a constantan wire / steel hollow cylinder construction. The experiments showed that the measuring junction electrical resistance, temperature–voltage characteristic, measuring junction rise time and signal noise standard deviation of the acicular thermocouples are comparable to those of conventional J-type thermocouples with bare wire diameter...
-
Energy, water detailed usage. Living lab testing for sustainable urban food-water-energy cycle. Jan. 2022
Dane BadawczeData set contains detailed, continuous measurements of the usage of water and electrical energy (AC power) in an experimental facility set up in a scientific laboratory (Laboratorium im. B.Niemkiewicza) at the Faculty of Mechanical Engineering and Ocean Technology of the Gdansk University of Technology. The test bed was established in co-operation...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 2 wire probe
Dane BadawczeThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 3 wire probe
Dane BadawczeThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Energy, water detailed usage. Living lab testing for sustainable urban food-water-energy cycle. Dec. 2021
Dane BadawczeData set contains detailed, continuous measurements of the usage of water and electrical energy (AC power) in an experimental facility set up in a scientific laboratory (Laboratorium im. B.Niemkiewicza) at the Faculty of Mechanical Engineering and Ocean Technology of the Gdansk University of Technology. The test bed was established in co-operation...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 24h exposition
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on protective foil using 2-wire probe 48h exposition
Dane BadawczeThe dataset presents impedance spectrum of anticorrosion foil (coating) protecting aluminium frame . This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole...
-
IR-THERMAL IMAGING IN CARDIOSURGERY
PublikacjaA method for monitoring the state of the myocardium during cardiosurgical interventions based on thermal IR imaging is presented. These methods called Static Thermography and Active Dynamic Thermography (ADT) uses information about distribution of temperature on the surface and an external excitation source to induce thermal transient processes in a tested object. Recording time series of thermograms allows to calculate parametric...
-
A new diagnostic IR-thermal imaging method for evaluation of cardiosurgery procedures
PublikacjaTwo methods for monitoring the state of the myocardium during cardiosurgical interventions based on thermal IR imaging are presented below. These methods, called static thermography and active dynamic thermography (ADT), use information about the distribution of temperature on the surface, and an external excitation source to induce thermal transient processes in a tested object. Recording the time series of thermograms allows...
-
Diagnostics of thermal processes in antenna systems of broadcast stations
PublikacjaDiagnostics is an important element associated with the operation of a radio antenna systems, allowing earlier detection of potential damage. Thermography is one of the diagnostic tools, which allows for non-invasive assessment of technical condition. It brings together both financial savings associated with the removal of the damage and the potential effects caused by it. The article presents an example of using a thermal imaging...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Use of pyrolysis and gas chromatography for the determination of acrylic acid concentration in acrylic copolymers containing carboxylic groups
Publikacja -
Tuning of microstructure in engineered poly (trimethylene terephthalate) based blends with nano inclusion as multifunctional additive
PublikacjaImmiscible blends and their composites are heterogeneous and have variable morphology due to variation in mesophase regions. Tuning, i.e. controlling the phase dimension is important, thereof we report a “super-combo” effect of multiwalled carbon nanotubes (MWCNTs) in poly (trimethylene terephthalate)/polypropylene (PTT/ PP) blend system. MWCNTs act as a good reinforcing agent and compatibilizer in the otherwise immiscible PTT/...
-
Nanostructured polyethersulfone nanocomposite membranes for dual protein and dye separation: Lower antifouling with lanthanum (III) vanadate nanosheets as a novel nanofiller
Publikacja -
Nanostructured polyethersulfone membranes for dye and protein separation: Exploring antifouling role of holmium (III) molybdate nanosheets
Publikacja -
In situ optical studies of thermal stability of iodine-doped polyazomethine thin films
Publikacja -
Phase diagram of P3HT:PC70BM thin films based on variable-temperature spectroscopic ellipsometry
Publikacja -
In situ thermo-optical studies of polymer:fullerene blend films
Publikacja -
New devices to capture the temperature effect under dynamic compression and impact perforation of polymers, application to PMMA
Publikacja -
Interfacially modified LDPE/GTR composites with non-polar elastomers: From microstructure to macro-behavior
PublikacjaThis paper provides some new insights into the mechanism of interaction and modifications in thermoplastic composites based on low density polyethylene (LDPE), ground tire rubber (GTR) and non-polar elastomer. The composites were prepared using a co-rotating twin-screw extruder at variable LDPE/GTR ratio and constant elastomer content. Two types of commercial elastomer were applied: styrene-butadiene-styrene (SBS) block copolymers (Kraton®)...
-
FTIR spectroscopic and thermogravimetric characterization of ground tyre rubber devulcanized by microwave treatment
PublikacjaIn this work, the phenomena involved in the microwave devulcanization of ground tyre rubber (GTR) were investigated. Three types of GTR with different content of organic compounds (elastomers, plasticizers, etc.), carbon black and ash have been studied. The chemical structure of GTR before and after a microwave devulcanization process was analyzed by Fourier transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA)...
-
Preparation and characterization of 3D collagen materials with magnetic properties
Publikacja -
Rotational molding of polylactide (PLA) composites filled with copper slag as a waste filler from metallurgical industry
PublikacjaThe research work carried out so far indicates the ever wider possibilities and demand for shaping composite products in the rotational molding technology. This trend was the main reason to use waste-based filler from the metallurgical process as a filler for manufacturing polylactide (PLA)-based remolded composites. Copper slag (CS) was introduced in the single-step processing method to PLA matrix at 5, 10, 20, and 35 wt%. The...
-
Evaluation and rationale of the performance of several elastomeric composites incorporating devulcanized EPDM
Publikacjathylene Propylene Diene rubber (EPDM), is present in many applications. However, its crosslinked structure makes difficult its recycling. The use of devulcanized EPDM, (dEPDM) as a component of elastomeric composites, is a real possibility to reuse EPDM scraps. In this study, three matrices (natural rubber (NR), styrene butadiene rubber (SBR) and EPDM rubber) have been tested including devulcanized EPDM as a recycled component....
-
Fabrication of exfoliated graphite reinforced silicone rubber composites - Mechanical, tribological and dielectric properties
PublikacjaThe effect of exfoliated graphite (EG) on the mechanical, tribological and dielectric properties of the silicone rubber (QM) composites has been systematically investigated and analysed. Morphological analysis of the composites helps to understand the interfacial interaction between the filler and the rubber matrix as well as wear mechanism respectively. An enhancement in the mechanical, tribological and dielectric properties was...
-
Fabrication of exfoliated graphite reinforced silicone rubber composites - Mechanical, tribological and dielectric properties
PublikacjaThe effect of exfoliated graphite (EG) on the mechanical, tribological and dielectric properties of the silicone rubber (QM) composites has been systematically investigated and analysed. Morphological analysis of the composites helps to understand the interfacial interaction between the filler and the rubber matrix as well as wear mechanism respectively. An enhancement in the mechanical, tribological and dielectric properties was...
-
Low-temperature air plasma modification of chitosan-coated PEEK biomaterials
Publikacja -
Structural, mechanical and thermal behavior assessments of PCL/PHB blends reactively compatibilized with organic peroxides
PublikacjaThe efficiency of two commercially available organic peroxides, dicumyl peroxide (DCP) and di-(2-tert-butyl-peroxyisopropyl)-benzene (BIB), during reactive processing of poly (ε-caprolactone)/poly (3-hydroxybutyrate) (PCL/PHB) blends was investigated. The changes in chemical structure of PCL/PHB blends, as a function of organic peroxide type (DCP/BIB) and content (in range: 0–1.0 parts by weight - pbw), were characterized by Fourier...
-
Structure-rheology relationship of fully bio-based linear polyester polyols for polyurethanes - Synthesis and investigation
PublikacjaThe synthesis of polyols from renewable substances as an alternative for petrochemical-based polyols play important matter in the polyurethane industry. In this work, the fully bio-based linear polyester polyols with different catalyst amounts were synthesized via two-step polycondensation method. The effect of various catalyst content on the structure and rheological behavior were established. Fourier Transform Infrared Spectroscopy,...
-
Novel cast polyetherurethanes based on dispersed polymeric polyols
PublikacjaOur study was focused on obtaining polyetherurethanes synthesized with using polymeric polyether based polyols differing in dispersed copolymer content (10, 20 and 40 wt%). The polyetherurethane materials were synthesized via two step method. The influence of different polymeric polyether based polyols on the chemical structure, morphology, mechanical and thermal properties of the obtained polyetherurethanes was investigated. The...
-
Towards understanding the role of peroxide initiators on compatibilization efficiency of thermoplastic elastomers highly filled with reclaimed GTR
PublikacjaThermoplastic elastomers based on recycled high density polyethylene (rHDPE) and styrene-butadiene-styrene (SBS) block copolymer were highly filled with reclaimed ground tire rubber (RR). The impact of various organic peroxides (dicumyl peroxide (DCP), benzoyl peroxide (BP) and di-tert-butyl peroxide (DB)), applied as free-radical initiators, on the processing, structure and performance properties of rHDPE/SBS/RR blends was investigated....
-
Assessment of the impact of bacteria Pseudomonas denitrificans, Pseudomonas fluorescens, Bacillus subtilis and yeast Yarrowia lipolytica on commercial poly(ether urethanes)
PublikacjaThe assessment of the impact of the bacteria Pseudomonas denitrificans, Pseudomonas fluorescens, Bacillus subtilis and yeast Yarrowia lipolytica on commercial poly(ether urethanes) Tecoflex® and Tecothane® is presented. The polyurethane samples were incubated with pure cultures of the microorganisms at 30 °C for five months. The changes in the chemical structure of the polymers were evaluated using loss of weight and contact angle...
-
Influence of chemical structure on physicochemical properties and thermal decomposition of the fully bio-based poly(propylene succinate-co-butylene succinate)s
PublikacjaIn this work, two polyesters and four copolyesters were studied. All materials were synthesized to obtain the monomers dedicated for thermoplastic polyurethane elastomers. For this type of PUR, the monomers should characterize by appropriate selected physicochemical properties and macromolecular structure distribution, which depends on synthesis conditions. The study of chemical structure with extensive and knowledgeable analysis...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 3
Dane BadawczeThe dataset presents impedance spectrum of epoxy based coating (code-name EPCS1) sample 3. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Stanisław Galla dr inż.
OsobyUrodził się w 1970 w Gdańsku. Jest absolwentem Technikum Mechaniczno Elektrycznego w Gdańsku (1990). Studiował na Wydziale Elektrotechniki Politechniki Gdańskiej (studia ukończył w 1996). Rozprawę doktorską pt. „Metodyka zwiększania dokładności pomiarów małoczęstotliwościowych wskaźników zaburzeń okresowych występujących w sieciach niskiego napięcia” obronił w 2009 r na Wydziale Elektrotechniki i Automatyki Politechniki Gdańskiej....
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 2
Dane BadawczeThe dataset presents impedance spectrum of nano-nickel based coating sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 1
Dane BadawczeThe dataset presents impedance spectrum of nano-nickel based coating sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Marcin Kulawiak dr hab. inż.
Osoby -
Arkadiusz Szewczyk dr inż.
OsobyArkadiusz Szewczyk uzyskał tytuł magistra inżyniera w roku 1996 na Wydziale Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej w zakresie aparatury elektronicznej. Stopień doktora nauk technicznych uzyskał w roku 2002 w ramach współpracy pomiędzy Politechniką Gdańską a Institut National Polytechnique de Grenoble we Francji. Obecnie zatrudniony jest w Katedrze Metrologii i Optoelektroniki na stanowisku adiunkta. W...