Filtry
wszystkich: 748
-
Katalog
- Publikacje 531 wyników po odfiltrowaniu
- Czasopisma 7 wyników po odfiltrowaniu
- Osoby 23 wyników po odfiltrowaniu
- Wynalazki 1 wyników po odfiltrowaniu
- Projekty 1 wyników po odfiltrowaniu
- Aparatura Badawcza 9 wyników po odfiltrowaniu
- Kursy Online 24 wyników po odfiltrowaniu
- Wydarzenia 1 wyników po odfiltrowaniu
- Dane Badawcze 151 wyników po odfiltrowaniu
Wyniki wyszukiwania dla: AC/AC CONVERTERS, PWM AC ENERGY CONVERSION, LINE CONDITIONERS
-
Reactions of cobalt(ii) chloride and cobalt(ii) acetate with hemisalen-type ligands: ligand transformation, oxidation of cobalt and complex formation. Preliminary study on the cytotoxicity of Co(ii) and Co(iii) hemisalen complexes
PublikacjaSeveral molecular cobalt(II) complexes, one Co(II) coordination polymer, and one ionic cobalt(III) complex with imine hemisalen ligands were synthesized. The hemisalen ligands were synthesized from o-vanillin (oVP) and diverse aminopyridines (compounds HL1–HL4) or aminophenol (compound HL5). It was observed that cobalt(II) chloride in dry acetonitrile catalyzes a transformation of HL1 and HL3 instead of complex formation. The conversion...
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublikacjaIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
STANY NIEUSTALONE TOWARZYSZĄCE POMIAROWI IMPEDANCJI PĘTLI ZWARCIA W OBWODACH WYJŚCIOWYCH ZASILACZY BEZPRZERWOWYCH UPS
PublikacjaW pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem...
-
Selective Harmonic Elimination PWM For a Cascaded Multi-level Inverter
PublikacjaThis paper deals with the selective harmonic elimination pulse width modulation (SHE-PWM) technique. This technique is used for the elimination of selected dominant low order harmonics in the multi-level inverter output voltage. The presence of these harmonics is the essential drawback of such kind of inverters; especially when it is used for the control of different AC drivers. The SHE-PWM is based...
-
Badanie wybranych właściwości wyłączników różnicowoprądowych typu F
PublikacjaW instalacjach elektrycznych niskiego napięcia instaluje się coraz więcej przekształtników energoelektronicznych (systemy fotowoltaiczne, instalacje ładowania pojazdów elektrycznych, układy napędowe o regulowanej prędkości obrotowej silnika), a mają one wpływ na dobór typu wyzwalania wyłączników różnicowoprądowych (AC, A, F lub B). W obwodach, w których pojawia się prąd różnicowy zawierający składowe o częstotliwości innej niż...
-
The new SDMT-family of servo-drives for CNC systems with AC permanent magnet synchronous motors
PublikacjaW artykule przedstawiono strategię sterowania podstawowe parametry oraz wyniki badań nowej rodziny serwonapędów typu SDMT. Układ sterowania serwonapędu zbudowano na procesorze sygnałowym TMS320F2812 firmy Texas Instruments. W serwonapędzie zastosowano metodę sterowania tupu FOC (ang. Field Oriented Control). Regulatory położenia, prędkości i momentu zreali-zowano na bazie klasycznego regulatora PID z układem ograniczenie sygnału...
-
SiC-based T-type modules for multi-pulse inverter with coupled inductors
PublikacjaThe paper presents SiC-based three-level T-type modules designed for a high-performance 30kVA DC/AC inverter operating at high frequency 85 kHz with low THD of the output voltage. This inverter system consists of two integrated parts. The first part is active and contains three parallelconnected three-phase T-type modules built with fast-switching SiC power transistors. The second, passive part of the system is a set of inductors...
-
PUBLICZNE ŚRODKI TRANSPORTOWE A SAMOCHÓD ELEKTRYCZNY W OBSŁUDZE PODRÓŻY MIEJSKICH W METROPOLII TRÓJMIEJSKIEJ
PublikacjaMetropolia trójmiejska ma wyjątkowo negatywne uwarunkowania terenowe dla funkcjonowania i rozwoju sieci komunikacji publicWyznej. Dzielnice położone w tzw. dolnym tarasie są dobrze skomunikowane za pomocą linii SKM i tramwajowych. Jedynie te środki komunikacji szynowej, przy częstotliwości połączeń nie większej niż co 10 minut, są konkurencyjne dla indywidualnych dojazdów samochodami osobowymi. Natomiast autobusy i trolejbusy utykające...
-
AC loss measurements in superconducting magnet
PublikacjaThis report contains ordered theoretical informations about AC loss in superconducting magnets and cables. A software program to evaluate data from AC loss measurements with V-I method was made and it is also described. Examples of measurement data and result data are shown here.
-
Hybrid stepless distribution transformer with four-quadrant AC/DC/AC converter at low voltage side - simulation tests
PublikacjaThe article presents the work of the stepless hybrid distribution transformer (HT), as an alternative to the so far applied Automatic Voltage Regulator (AVR) solutions, used to control the voltage in the power system in terms of the fundamental harmonic. The HT is a combination of a conventional distribution transformer and an AC/DC/AC converter connected in series with the transformers secondary winding. In the work the basic...
-
Time-domain measurement methods for R, L and C sensors based on aversatile direct sensor-to-microcontroller interface circuit
PublikacjatIn the paper new time-domain measurement methods for determining values of resistive (R), inductive(L) and capacitive (C) sensors based on a versatile direct sensor-to-microcontroller interface for microcon-trollers with internal analog-to-digital converters (ADCs) and analog comparators (ACs) are presented.The interface circuit consists of a reference resistor Rrworking as a voltage divider, a given R, L or C sensorand a microcontroller...
-
Lingua ac Communitas
Czasopisma -
Estimation of the uncertainty of the AC/AC transducer output voltage
PublikacjaThe paper presents a methodology for estimating uncertainty of voltage transducers processing function, on the example of CYVS411D07 voltage transducers. The analysis was conducted using the method based on the GUM Guide propagation of uncertainty law and the determination of the coverage factor based on the effective number of degrees of freedom (t-Student distribution). The paper also presents example evaluation results of measured...
-
Przegląd systemów ładowania elektrycznych osobowych pojazdów i koncepcja dwukierunkowej ładowarki pokładowej
PublikacjaAktualnie trwa intensywny rozwój pojazdów elektrycznych (EV) i hybrydowych typu plug-in (PHEV) z pokładowymi bateriami akumulatorów. Badania w tej dziedzinie skupiają się na maksymalizowaniu sprawności oraz minimalizowaniu masy i objętości systemów ładowania baterii. W artykule przedstawiono podział systemów ładowania osobowych pojazdów typu EV/PHEV. Opisano systemy ładowania przewodowego z podziałem na ładowarki pokładowe i zewnętrzne, systemy...
-
Multiscalar Model Based Control Systems for AC Machines
PublikacjaContents of the Chapter: Nonlinear transformations and feedback linearization. Models of the squirrel cage induction machine: Vector model of the squirrel cage induction machine. Multiscalar models of the squirrel cage induction machine.Feedback linearization of multiscalar models of the induction motor.Models of the double fed induction machine: Vector model of the double fed induction machine. Multiscalar model of the...
-
Variable Speed AC Drives with Inverter Output Filters
PublikacjaThe advance of variable speed drives systems (VSDs) engineering highlights the need of specific technical guidance provision by electrical machines and drives manufacturers, so that such applications can be properly designed to present advantages in terms of both energy efficiency and expenditure. This book presents problems and solutions related to inverter-fed electrical motors. Practically orientated, the book describes the...
-
Przetwornica rezonansowa LLC AC-DC w układzie półmostka
PublikacjaW artykule przedstawiono rezultaty prac nad rezonansową przetwornicą AC/DC typu LLC w układzie półmostka o mocy 100W. Układ sterowania przetwornicy został opracowany w oparciu o dedykowany sterownik UCC25600 (Texas Instrumens). W pracy przedstawiono koncepcję przetwornicy oraz porównano właściwości opracowanej przetwornicy z komercyjnie dostępnym układem typu Flyback.
-
Superconductivity and itinerant ferromagnetism of Y9Co7 probed by ac susceptibility
PublikacjaThe ac magnetic susceptibility of a single crystal sample of the compound Y9Co7 has been measured in applied dc fields ranging from 0–6.7 kOe by utilizing a tunnel diode resonator circuit. In agreement with previous measurements on this material, a superconducting transition has been observed to occur at TSC ≈ 2.5 K. A broad maximum has been observed in the zero field susceptibility measurements from 2.5 K < T < 8 K and its behavior...
-
Ac and dc conductivities in v2o5-p2o5 glasses containing alkaline ions
PublikacjaWe investigated the ac and dc conductivity in 50V2O5-(50 − x)P2O5-xA2O (A = Li, Na, K) glasses as a function of temperature. The measurements were carried out in the frequency range from 10−4 to 107 Hz. For all compositions, the dc conductivity decreased with the increasing alkali ion content. The decrease in conductivity was more pronounced for larger alkali ions. The ac conductivity exhibited a universal dynamic response: σac...
-
Jednofazowy falownik napięcia z aktywnym obwodem odsprzęgającym
PublikacjaZnanym zagadnieniem w jednofazowych falownikach napięcia jest pobieranie ze źródła napięcia stałego składowej przemiennej o częstotliwości dwukrotnie większej od częstotliwości generowanej przez falownik. Jednym z rozwiązań problemu jest stosowanie dużej baterii kondensatorów elektrolitycznych, lecz lepszym sposobem z punktu widzenia niezawodności i gęstości mocy przekształtnika jest stosowanie aktywnych układów odsprzęgania mocy....