Filtry
wszystkich: 616
-
Katalog
Wyniki wyszukiwania dla: KNEE JOINT TRANSLATION
-
The influence of a change in the meniscus cross-sectional shape on the medio-lateral translation of the knee joint and meniscal extrusion
PublikacjaObjective The purpose of this study was to evaluate the influence of a change in the meniscus cross sectional shape on its position and on the biomechanics of a knee joint. Methods One main finite element model of a left knee joint was created on the basis of MRI images. The model consisted of bones, articular cartilages, menisci and ligaments. Eight variants of this model with an increased or decreased meniscus height were then...
-
Biomechanics of the medial meniscus in the osteoarthritic knee joint
PublikacjaBackground. Increased mechanical loading and pathological response of joint tissue to the abnormal mechanical stress can cause degradation of cartilage characteristic of knee osteoarthritis (OA). Despite osteoarthritis is risk factor for the development of meniscal lesions the mechanism of degenerative meniscal lesions is still unclear. Therefore, the aim of the study is to investigate the influence of medial compartment knee OA...
-
Modeling knee joint endoprosthesis mode of deformation
Publikacja -
Assessment of the Relationship between the Shape of the Lateral Meniscus and the Risk of Extrusion Based on MRI Examination of the Knee Joint
PublikacjaBackground Meniscus extrusion is a serious and relatively frequent clinical problem. For this reason the role of different risk factors for this pathology is still the subject of debate. The goal of this study was to verify the results of previous theoretical work, based on the mathematical models, regarding a relationship between the cross-section shape of the meniscus and the risk of its extrusion. Materials and Methods Knee...
-
3D intact knee model used in analysis of the medial meniscus biomechanics in the osteoarthritic knee joint - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model with original geometry and material parametetrs was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. The file was created in Abaqus 6.14-2, but can be read in a text editor.
-
3D model of osteoarthritic (OA) knee joint for analysis of the medial meniscus biomechanics - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. In the OA model thickness of articular cartilage and material parameters of the cartilage and menisci were reduced to simulate degenerative changes in the...
-
Influence of meniscus shape in the cross sectional plane on the knee contact mechanics
PublikacjaWe present a three dimensional finite element analysis of stress distribution and menisci deformation in the human knee joint. The study is based on the Open Knee model with the geometry of the lateral meniscus which shows some degenerative disorders. The nonlinear analysis of the knee joint under compressive axial load is performed. We present results for intact knee, knee with partial and complete radial posterior meniscus root...
-
3D knee model G with reduced thickness of articular cartilage - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. In the model G articular cartilage thickness was reduced in specific areas to simulate degenerative changes in the medial knee osteoarthritis. The file was...
-
3D knee model M with decreased material parameters of the cartilage and menisci - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. In the model M the material parameters of cartilage and menisci were reduced to simulate degenerative changes in the medial knee osteoarthritis. The file...
-
The Influence of Articular Cartilage Thickness Reduction on Meniscus Biomechanics
PublikacjaObjective Evaluation of the biomechanical interaction between meniscus and cartilage in medial compartment knee osteoarthritis. Methods The finite element method was used to simulate knee joint contact mechanics. Three knee models were created on the basis of knee geometry from the Open Knee project. We reduced the thickness of medial cartilages in the intact knee model by approximately 50% to obtain a medial knee osteoarthritis...
-
Biocompatibility and bioactivity of bearing loaded metallic implants
PublikacjaPresentation of developed titanium alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behavior for bearing loaded implants, e.g. hip joint and knee joint endoproshtesis.
-
Proximal fibular osteotomy as a treatment for degenerative meniscal extrusion
PublikacjaMeniscal extrusion treatment is a key focus area for research and clinical study of degenerative knee pathology. The contact forces between the meniscus and the bones cause external displacements of the meniscus that are resisted by the circumferential fibres. The main risk factors for the excessive deformation of the meniscus are meniscal root tears, disruption of the circumferential fibres, knee malalignment and high body mass...
-
Biocompatibility and Bioactivity of Load-Bearing Metallic Implants
PublikacjaThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
Wpływ wysokiej osteotomii piszczelowej na mechanikę stawu kolanowego
PublikacjaW rozprawie podjęto próbę weryfikacji wpływu zabiegu chirurgicznego wysokiej osteotomii piszczelowej na mechanikę stawu kolanowego. Po wykonanym przeglądzie literatury, postawiono trzy hipotezy, które poddano weryfikacji na drodze badań numerycznych. Otrzymane wyniki zwalidowano poprzez badania nacisków powierzchniowych występujących w stawach kolanowych świni domowej, prowadzonych na maszynie do jednoosiowego ściskania. Praca...
-
Receiver-side fingerprinting method based on quaternion sandwich product
PublikacjaIn this paper a new receiver-side fingerprinting method for color images is proposed. The proposed method belongs to the group of Joint Fingerprinting and Decryption (JFD) methods. Each component of the color image is represented as a point in 3D space, which is formed by 3 color channels. Encryption and fingerprinting can be interpreted as rotation, scaling and translation of these points. Calculations are performed using quaternion...
-
Study of Nanohydroxyapatite Coatings Prepared by the Electrophoretic Deposition Method at Various Voltage and Time Parameters
PublikacjaThe aim of the work is to compare the properties of nanohydroxyapatite coatings obtained using the electrophoretic deposition method (EDP) at 10 V, 20 V, and 30 V, and with deposit times of 2 and 5 min. The primary sedimentation was used to minimize the risk of the formation of particle agglomerates on the sample surface. Evaluation of the coating was performed by using a Scanning Electron Microscope (SEM), Energy-Dispersive Spectroscopy...
-
Approach for Determination of Functioning of Lower Limb Muscles
PublikacjaThe purpose of the study is elaboration of approach for determination of functioning of chosen muscles that are essential for gait performance (Tibialis Anterior, Rectus Femoris, Gastrocnemius Medialis, Biceps Femoris). The scope of the study involves the analysis of the symmetric planar motion performing in the sagittal plane of the body by applying planar multibody model and electromyography signals (EMG) registered over normal...
-
pH-dependent composite coatings for controlled drug delivery system - Review
PublikacjaNowadays in case of long-term implants, the most common postoperative complications are bacterial infections, which in consequence may provoke loos- ening of the implants in the primary phase of stabilization. Bacterial infections are currently the most frequent cause of revision surgery of the implants such as hip joint endoprosthesis, knee joint endoprosthesis and dental implants. In order to provide the local and long-term antibacterial...
-
Ocena odporności na zużycie ścierne stopów Ti na elementy pary trącej endoprotez stawu kolanowego
PublikacjaNajczęściej stosowanym biomateriałem tytanowym na elementy endoprotez stawu kolanowego jest stop Ti6Al4V. Z uwagi na zawartość wanadu, zaliczanego do pierwiastków o dużej toksyczności podejmowane są działania w kierunku zastąpienia wskazanego stopu - stopami bezwanadowymi. Jednym z najbardziej obiecujących jest stop Ti13Nb13Zr zawierający w swoim składzie jedynie pierwiastki witalne, niewywołujące stanów zapalnych i odczynów...
-
Biocompatibility and bioactivity of load-bearing metallic implants
PublikacjaThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
KNEE
Czasopisma -
Phraseological Units in Audiovisual Translation. A Case Study of Polish Dubbing of Disney’s 'The Little Mermaid'
PublikacjaThe paper aims to discuss phraseological units as the object of audiovisual translation in the Polish dubbing of Disney’s 'The Little Mermaid', to discuss the role of phraseological translation techniques, and to present possible translation inconsistencies. A theoretical introduction presents definitions for crucial terms. It is followed by the analysis of the corpus of phraseological units in Disney’s The Little Mermaid and...
-
Evaluation of Wear Resistance of Ti alloys used for elements friction of knee endoprosthesis
PublikacjaThe paper presents research results of resistance to abrasive wear of titanium alloys: Ti6Al4V (commonly used) and Til3Nb13Zr (alloy of new generation) in association with polyethylene (UHMW-PE) predisposed for elements on pair of the knee endoprosthesis. The results were analysed from the point of possibility of an use of new generation titanium alloys as components of such implants. The tests of resistance to abrasive wear of...
-
Early vascular ageing in translation
Publikacja -
Seismic Response Analysis of Knee-Braced Steel Frames Using Ni-Ti Shape Memory Alloys (SMAs)
PublikacjaShape Memory Alloys (SMAs) are known as active materials that can be widely used for structural purposes due to their flag-shape behavior under loading and reloading. Their unique characteristics provided a potential solution for civil engi-neers especially to model buildings with the capability of dissipating seismic en-ergy. In this study, the main purpose is to explore the seismic behavior of Knee-Braced Frames (KBFs) and...
-
Analysis of wave propagation in a bolted steel joint
PublikacjaThe paper presents results of numerical and experimental investigations of elastic wave propagation in a bolted single-lap joint. The research was carried out for both symmetric and antisymmetric Lamb wave modes. In experimental studies the PZT transducers were used to excite and register wave propagation signals. The controlled value of the torque during measurements was ensured by the use of high precision torque wrenches. Numerical...
-
Translation
Czasopisma -
3D Computer Model of the Hip Joint Cartilage
PublikacjaThis paper presents 3D computer model of the hip joint cartilage in the ANSYS program. Model is made on the basis of anatomy and collected data on the material constants of bone and cartilage components. Analysis and comparison of biochemical model, viscoelastic and molecular mixed - aggregation serves to facilitate the creation of the next model of reality, which could be used in the design of joint prostheses. The correctness...
-
Medially positioned plate in first metatarsophalangeal joint arthrodesis
PublikacjaObjective The purpose of this study was to biomechanically compare the stability of first metatarsophalangeal (MTP1) joint arthrodesis with dorsally and medially positioned plates. Methods A physical model of the MTP1 joint consists of printed synthetic bones, a titanium locking plate and screws. In the experiments, samples with dorsally and medially positioned plates were subjected to loading of ground load character in a universal...
-
Journal of Knee Surgery
Czasopisma -
Lamb wave propagation in a single lap adhesive joint
PublikacjaThe aim of the paper is the analysis of Lamb wave propagation in adhesive joints. The research was performed on a single lap adhesive joint of two steel plates. Two types of joints, namely an intact and with defect were considered. In experimental investigations the condition assessment of the joint was performed with the use of antisymmetric Lamb waves excited by a plate piezo actuators and measured by a laser vibrometer. Numeri-cal...
-
A cryptic ribosome binding site, false signals in reporter systems and avoidance of protein translation chaos
PublikacjaThe expression of reporter gene may be induced by activation of cryptic signalling sequences, as we found while constructing the mutS-lacZ fusion gene. We cloned the Escherichia coli lacZ gene encoding beta-galactosidase into a plasmid vector carrying the Thermus thermophilus mutS gene. The clones expected to produce beta-galactosidase as the C-terminal fusion were selected for the complementation of beta-galactosidase activity...
-
Annals of Joint
Czasopisma -
Diagnostics of bolted lap joint using guided wave propagation
PublikacjaThe paper presents numerical and experimental analyses of elastic waves propagation in a bolted lap joint. In experimental investigations condition assessment of the joint was performed with the use of symmetric waves excited by a piezoactuator. Numerical calculations were conducted in commercial finite element method software Abaqus. The influence of number of bolts and the value of the initial stress on recorded signals was examined....
-
THE INFLUENCE OF MANUFACTURING OVERSIZING ON POSTWELDING DISTORTIONS OF THE FILLET WELDED JOINT
PublikacjaWelding proces is basic joining technique in shipbuilding. Such method generated welding distortions which cause a lot of problems during the manufacturing process. In the literature it is proposed wide spectrum of suggestions for a correct estimation of welding deformation in particular angular deformation in the fillet welded T joint. In the work influence of oversizing of weld on angular distortions of joint is presented basing...
-
The validation process of truss model with joint eccentricities
PublikacjaNowadays, due to the technological reasons in modern lightweight steel trusses, fabricated from cold-formed sections, positive eccentricities appear in the truss nodes, to induce additional forces truss chords. In order to account for the real load-carrying capacity of truss node area the steel structure research was conducted in scale 1:1. As a result of experimental research, the forms of deformation and strains of the walls...
-
Osteotomies and Total Knee Arthroplasty: Systematic Review and Meta-Analysis
Publikacja -
Dynamics of Systems with a Discontinuous Hysteresis Operator and Interval Translation Maps
Publikacja -
Possibilities for assesment of the angular distortion in Welded T-joint
PublikacjaSpawanie jest podstawową techniką łączenia elementów konstrukcji kadłuba statku. Procesowi temu towarzyszą odkształcenia spawalnicze, co przysparza dużo problemów wykonawczych. W pracy przedstawiono wpływ przewymiarowania spoiny pachwinowej na wielkość kątowych odkształceń złącza. Dokonano porównania wartości określonych na podstawie inżynierskich hipotez z wynikami otrzymanymi podczas prób laboratoryjnych.
-
Communication tools framework for a joint venture company - internal communication
PublikacjaThe article presents a set of communication tools that can be used by a joint venture company. The publication begins by presenting a historical outline of communication, then divided communication tools into internal with their brief characteristics, indicated the purpose of their use and what impact the use of communication tools has in the communication department in a joint venture company. For...
-
Communication tools framework for a joint venture company - external communication
PublikacjaThe article presents a set of communication tools that can be used by a joint venture company. The publication begins by presenting a historical outline of communication, then divided communication tools into external with their brief characteristics, indicated the purpose of their use and what impact the use of communication tools has in the communication department in a joint venture company. For...
-
Damage detection in a bolted lap joint using guided waves
PublikacjaThe paper presents the experimental investigation of guided waves application to the condition assessment of prestressed bolted connections and a concept of new quantitative indicator. The main goal of the research was the analysis of the influence of the contact conditions changes to the characteristics of a propagating disturbance. The experimental tests were carried out for a single bolted lap joint. The excitation and acquisition...
-
Jaw biomechanics: Estimation of activity of muscles acting at the temporomandibular joint
PublikacjaThe aim of this study was to elaborate a method of estimation of activity of surface muscles acting at the temporomandibular joint of the healthy subjects by using a surface electromyography (EMG). The scope of this study involved testing chosen jaw motions (open, close, lateral deviation) and process of mastication occurring during eating food with different toughness (chewing gum, cereal and carrot) by using mixed sides, right...
-
Load carrying capacity of the eccentric joint in the truss made of open cross-sections
PublikacjaThe influence of eccentricity at intersections of truss members on the load carrying capacity of the truss joint is presented in the paper. The research truss elements were designed as cold-formed open cross section. Analytical calculations, numerical analysis and experimental research were conducted to reveal how the eccentricity affects the effort of material in the joint area. The results of analysis and investigations are compared...
-
Knee Surgery and Related Research
Czasopisma -
Journal of Translation
Czasopisma -
Translation and Literature
Czasopisma -
Interculturality and Translation
Czasopisma -
Translation Review
Czasopisma -
Machine Translation
Czasopisma