Wyniki wyszukiwania dla: doping, ibuprofen, horse, urine, gc-ms
-
Simultaneous determination of ibuprofen and its metabolites in complex equine urine matrices by GC-EI-MS in excretion study in view of doping control
PublikacjaA novel assay for the simultaneous determination of ibuprofen (IBU) and its four probable metabolites, 1-hydroxyibuprofen (1-OH IBU), 2-hydroxyibuprofen (2-OH IBU), 3-hydroxyibuprofen (3-OH IBU) and carboxyibuprofen (CBX IBU) in equine urine samples with the application of Gas Chromatography-Electron Ionization-Mass Spectrometry (GC-EI-MS) has been developed and elaborated. The new approach for sample preparation including minimizing...
-
Quantification of unconjugated and total ibuprofen and its metabolites in equine urine samples by gas chromatography–tandem mass spectrometry: Application to the excretion study
PublikacjaIbuprofen (IBU) is a widely used nonsteroidal anti-inflammatory drug (NSAID) in human and also veterinary medicine. NSAIDs are usually highly metabolized compounds in horses; they are often present in equine urine, mostly in their conjugated forms (glucuronides). Thus, hydrolysis to cleave the glucuronide linkage prior to anti-doping analysis is often necessary for improving detection. In this study, unconjugated and total IBU...
-
Elimination of excretion of ibuprofen and its metabolites in horses
PublikacjaAnalytical procedure based on application of gas chromatography-mass spectrometry (GC-MS) at the step of detection, identification and quantitation of ibuprofen (IBU) and detection of its metabolites – 1-hydroxyibuprofen (1-OH IBU) and carboxyibuprofen (CBX IBU) in horse urine by selected ion monitoring mode after sample preparation covering extraction at pH 3-4 and methylation has been used. The ions at m/z 161, 220 (methylated...
-
Recent Applications of 1D GC-MS and 2D GC-MS in Foodomics Studies
PublikacjaGas chromatography coupled with mass spectrometry and food chemistry have been tightly linked since the 1960s. This setup is also an integral part of the omics studies when it comes to low mass metabolites. Therefore, the marriage of GC-MS and foodomics is obvious. Two-dimensional gas chromatography coupled with mass spectrometry fits perfectly within the latest trends in foodomics, since it is tailored for holistic food analysis....
-
PTR-MS and GC-MS as complementary techniques for analysis of volatiles: A tutorial review
PublikacjaThis tutorial review is a critical commentary on the combined use of two instrumental analytical techniques, namely GC-MS and PTR-MS. The first mention of such an analytical approach likely appeared after the year 2000 and despite many advantages, it has not been applied very often. Therefore, the aim of this article is to elaborate on the concept of their combined use and to provide a curse tutorial for those considering taking...
-
CE-MS and GC-MS as “Green” and Complementary Methods for the Analysis of Biogenic Amines in Wine
PublikacjaTwo novel complementary analytical methods, namely an extraction-free capillary electrophoresis coupled to mass spectrometry (CE-MS) and direct immersion-solid-phase microextraction combined with gas chromatography-mass spectrometry (DI-SPME-GC-MS), have been developed and successfully applied for the determination of biogenic amines (BAs) in wine and fruit wine. They have been rigorously compared to each other in terms of various...
-
A rapid and sensitive method for the quantitative analysis of ibuprofen and its metabolites in equine urine samples by gas chromatography-tandem mass spectrometry
PublikacjaIbuprofen is widely used in human and veterinary medicine for the treatment of chronic pain as well as rheumatic and musculoskeletal disorders. However, t he anal- gesic and anti-inflammatory properties of Ibuprofen have contributed to frequent drug abuse in equestr ian s ports. A sensitive and rapid gas chromatography with tandem mass spectrometry based method with a simple liquid-liquid extraction and deriva- tization requiring...
-
Determination of odour concentration by TD-GC×GC–TOF-MS and field olfactometry techniques
PublikacjaField olfactometry is one of the sensory techniques used to determine odour concentration, in atmospheric air, directly in emission sources. A two-dimensional gas chromatography with time of flight mass spectrometer (GC×GC–TOF-MS) allows performing the chemical characterization of various groups of chemical compounds, even in complex mixtures. Application of these techniques enabled determination of odour concentration level in...
-
Urine metabolic fingerprinting using LC–MS and GC–MS reveals metabolite changes in prostate cancer: A pilot study
Publikacja -
Application of GC-MS/MS technique for the determination of benzodiazepines in blood samples
PublikacjaAbstract Benzodiazepines (BZD) are widely used as pharmaceuticals in medicine. However, due to psychostimulatory effect of BZD, in the last decade, they are more and more often used as drugs of abuse. These compounds produce similar effects to classical illicit drugs and are sold as “legal” alternatives to them as new psychoactive substances (NPS). Currently new BZD, named designer benzodiazepines (DBZD), are synthesized each year...
-
Comparison of GC–MS and MEKC methods for caffeine determination in preworkout supplements
PublikacjaIn this study, GC–MS- and MEKC-based methods for determination of caffeine (CAF) in preworkout supplements were developed and validated. The proposed protocols utilized minimal sample preparation (simple dilution and syringe filtration). The developed methods achieved satisfactory validation parameters, i.e. good linearity (R2 0.9988 and R2 0.9985 for GC–MS- and MEKC-based method, respectively), satisfactory intraand interaccuracy...
-
GC-MS-based untargeted metabolomics of plasma and urine to evaluate metabolic changes in prostate cancer
Publikacja -
Problems of PAH quantification by GC-MS method using isotope-labelled standards.
PublikacjaChromatografia gazowa w połączeniu ze spektromerią mas (GC-MS) jest obecnie rutynowo stosowaną metodą w analityce środowiskowej do oznaczania śladowych ilości zanieczyszczeń organicznych. Stosowanie detektora mas sprawia, że wygodnym wzorcem wewnętrznym są stabilne izotopowo analogi oznaczanych związków. Związki te są wykorzystywane do śledzenia i kompensacji strat analitów podczas wykonywania określonych operacji związanych z...
-
Development and validation of a GC–MS/MS method for the determination of 11 amphetamines and 34 synthetic cathinones in whole blood
PublikacjaPurpose Psychoactive compounds that contain a phenylethylamine structure (such as amphetamine-type stimulants and synthetic cathinones) are one of the major classes of stimulants on the recreational drug market. Approximately 670 new psychoactive substances (NPS) are monitored only in Europe; however, new psychoactive compounds are being developed for illicit trade each year. In this context, the development of new analytical procedures...
-
Determination of benzodiazepines and Z-hypnotic drugs in whole blood samples by GC–MS/MS: Method development, validation and application
PublikacjaBenzodiazepines (BZDs) and Z-drugs are widely used as anxiolytics, sedative hypnotics, anticonvulsants and muscle relaxants. “Designer benzodiazepines” (DBZDs) are a new psychoactive substance class consisting of benzodiazepine derivatives that are not allowed for medical use and are known for being used recreationally. From a toxicologist standpoint, the huge number of such substances implicate a necessity for developing fast...
-
A novel methodology for the enantiomeric resolution of methamphetamine, its precursors and intermediates by GC-MS
PublikacjaImpurity profiling and classification of abused drugs using chiral analytical techniques is of particular interest and importance because of the additional information obtained from this approach. When these methods are applied to the synthesis of illicitly used substances, they can supply valuable information about the conditions/chemicals used in the synthesis. In this study, simultaneous chiral separation of methylamphetamine,...
-
Direct-Ultrasonic Assisted Microextraction Coupled with RTL-GC-FID/GC-MS as a Future Standard Procedure for Monitoring 26 potentially Allergenic Fragrances in Water Samples
PublikacjaThis research topic grew up as a result of awareness of constant anthropogenic and natural input to the environment constituents of personal care products (PCPs) residues. This group of emerging pollutants encompasses a wide range of chemicals, including potentially allergenic fragrance compounds. The aim of the present study was to investigate presence of 26 fragrance allergens in water samples. Simple and rapid methodology based...
-
Monitoring of occupational exposure to volatile organohalogen solvents (VOXs) in human urine samples of dry-cleaner workers by TLHS-DAI-GC-ECD procedure
PublikacjaChlorinated hydrocarbon solvents are often used for dry-cleaning clothes in the laundry industry. The object of this study was to monitor the occupational exposure of dry-clean employees coming into contact with VOXs. 25 workers collected their urine samples before the work shift, after 4 hours of work and after the work shift. The analyses of urine samples and solvents used in dry-cleaning were performed using TLHS-DAI-GC-ECD....
-
3-Monochloropropane-1,2-diol in Infant Foods and Human Breast Milk: Determination by GC-MS
Publikacja3-Monochloropropane-1,2-diol is one of the food borne contaminants called chloropropanols. Over the last decade plenty of analytical methods was developed in order to determine 3-monochloropropane-1,2-diol in its free and bound form in various foodstuffs with the use of GC-FID, GC-ECD, LC-TOFMS and finally GC-MS, which is now widely used in laboratories. The aim of this research was the determination of 3-monochloropropane--1,2-diol...
-
Elucidation of transformation pathway of ketoprofen, ibuprofen, and furosemide in surface water and their occurrence in the aqueous environment using UHPLC-QTOF-MS
PublikacjaThe identification and determination of transformation products (TPs) of pharmaceuticals is essential nowadays, in order to track their fate in the aqueous environment and, thus, to estimate the actual pollution. However, this is a challenging task due to the necessity to apply high-resolution instruments enable to detect known and unknown compounds. This work presents the use of liquid chromatography quadrupole time-of-flight...