wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: preventive measures
-
Personalized prediction of the secondary oocytes number after ovarian stimulation: A machine learning model based on clinical and genetic data
PublikacjaControlled ovarian stimulation is tailored to the patient based on clinical parameters but estimating the number of retrieved metaphase II (MII) oocytes is a challenge. Here, we have developed a model that takes advantage of the patient’s genetic and clinical characteristics simultaneously for predicting the stimulation outcome. Sequence variants in reproduction-related genes identified by next-generation sequencing were matched...
-
The hydration of the protein stabilizing agents: trimethylamine-N-oxide, glycine and its N-methylderivatives - the volumetric and compressibility studies
PublikacjaThe densities at T = (288.15, 293.15, 298.15, 303.15, and 308.15) K and sound velocities at T = 298.15 K have been measured for aqueous solutions of trimethylamine-N-oxide, glycine, N-methylglycine (sarcosine), N,N-dimethylglycine, N,N,N-trimethylglycine (betaine). From these data the apparent molar volumes, VΦ, the apparent molar isentropic compressions, KS,Φ, and the solvation numbers of solutes have been determined. The concentration...
-
Is Digitalization Improving Governance Quality? Correlating Analog and Digital Benchmarks
PublikacjaThe digitalization of public governance and the resulting concept of electronic governance is a characteristic feature of contemporary information society. Both can be defined as the process and outcome of digital transformation: transformation of the “analog” version of governance into “digital” governance. Measuring both versions of governance against typical performance measures of efficiency, effectiveness, equity, openness...
-
Non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) - Female, 67 - Tissue image [11010630088562471]
Dane BadawczeThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) - Female, 67 - Tissue image [11010630088562991]
Dane BadawczeThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) - Female, 67 - Tissue image [11010630088563951]
Dane BadawczeThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) - Female, 67 - Tissue image [11010630088569751]
Dane BadawczeThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) - Female, 67 - Tissue image [11010630088567711]
Dane BadawczeThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) - Female, 67 - Tissue image [11010630088565141]
Dane BadawczeThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) - Female, 67 - Tissue image [11010630088569271]
Dane BadawczeThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Non-invasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) - Female, 67 - Tissue image [3300730069456521]
Dane BadawczeThis is the histopathological image of THYROID GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 49 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 49 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 29 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 27 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 27 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 29 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 24 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 24 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 53 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Man 53 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Woman 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
ECG measurement from the hand with first elbow rests on the armrest, second elbow in the air - Woman 30 age
Dane BadawczeThe data set shows the measurements of the ECG signal from the hand made with the use of the proprietary measuring system, based on the AD8232 and STM32 chips. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the hand. The results show the ECG signal for a specific hand and forearm position relative...
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 800 °C and 15% oxygen partial pressure
Dane BadawczeThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 800 °C and 15% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included....
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 700 °C and 100% oxygen partial pressure
Dane BadawczeThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 700 °C and 100% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included....
-
Linear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass heat-treated for 3 hours at 693 K, measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of partially crystallized 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 700 °C and 20% oxygen partial pressure
Dane BadawczeThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 700 °C and 20% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included....
-
Nonlinear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass heat-treated for 3 hours at 693 K, measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe nonlinear electrcial properties of partially crystallized 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass heat-treated for 10 hours at 693 K, measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of partially crystallized 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of Bi2VO5.5 ceramic of thickness 2.52 mm (after second heat-treatment at 913 K) was measured at high temperature range with impedance spectroscopy method
Dane BadawczeThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 2.52 mm (after second heat-treatment at 913 K) was measured by impedance spectroscopy method.
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 700 °C and 5% oxygen partial pressure
Dane BadawczeThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 700 °C and 5% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included. Results...
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 600 °C and 15% oxygen partial pressure
Dane BadawczeThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 600 °C and 15% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included. Results converted...
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 700 °C and 15% oxygen partial pressure
Dane BadawczeThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 700 °C and 15% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included....
-
Linear impedance as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K measured with impedance spectroscopy method at 273 K
Dane BadawczeThe linear electrcial properties as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K was measured by impedance spectroscopy method.
-
Nonlinear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass heat-treated for 10 hours at 693 K, measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe nonlinear electrcial properties of partially crystallized 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Paweł Tysiąc dr inż.
Osobydr inż. Paweł Tysiąc Urodził się 25 marca 1992 w Gdańsku. Po ukończeniu Gimnazjum nr 32 uczęszczał do VIII Liceum Ogólnokształcącego im. Komisji Edukacji Narodowej w Gdańsku, klasy o profilu matematyczno-geograficznym, uzyskując w 2011 roku świadectwo dojrzałości. Następnie w latach 2011-2016 kontynuował naukę na Wydziale Inżynierii Lądowej i Środowiska Politechniki Gdańskiej. Ukończył studia I stopnia w specjalności Geodezja...
-
TRANSPORT POSSIBILITY FOR MPEG-4/AVC- AND MPEG-2-ENCODED VIDEO DATA IN IPTV: A COMPARISON STUDY
PublikacjaIPTV (Television over IP) is a modern service with a great potential to expand. It uses the IP transport platform, that is already in worldwide operation. At the time of writing, two techniques are used to transport the video and audio data of IPTV: MPEG-2 TS and Native RTP. The two techniques quite definitely have an influence on both quality of service (QoS) and quality of experience (QoE). This paper sets out to demonstrate...
-
Path-based methods on categorical structures for conceptual representation of wikipedia articles
PublikacjaMachine learning algorithms applied to text categorization mostly employ the Bag of Words (BoW) representation to describe the content of the documents. This method has been successfully used in many applications, but it is known to have several limitations. One way of improving text representation is usage of Wikipedia as the lexical knowledge base – an approach that has already shown promising results in many research studies....
-
Dynamics of algae growth and nutrients in experimental enclosures culturing bighead carp and common carp: Phosphorus dynamics
PublikacjaThis is the third paper of the series about “Dynamics of algae growth and nutrients in experimental enclosures culturing bighead carp and common carp”. In this paper, phosphorus dynamics were investigated under the condition of culturing bighead carp and common carp with added fish food (nitrogen dynamics is discussed in the second paper because their behaviors are so different from each other). Nearly fifty days’ observation results...
-
Bioaccumulation of Metals in Tissues of Marine Animals, Part I: the Role and Impact of Heavy Metals on Organisms
PublikacjaHeavy metals contribute to the anthropogenic contamination of marine ecosystems. Some of them are essential to the life processes of organisms; others are toxic, even at low concentrations. They penetrate organisms via food, respiratory pathways or the skin. The extent to which metals penetrate organisms is measured by the bioconcentration and bioaccumulation factors and also by their transport between organisms at different trophic...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublikacjaLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Modified nanodiamond particle size studies by means of dynamic light scattering technique
PublikacjaThe Methods Utilizing the Phenomena of Light Scattering to Measure Particle Size distribution in different solvent, such as deionise water and alcohol and also to study the various structural formation when nanodiamond solution is placed on silicon surface. The purpose of this research project is divided into two parts to configure the measurement units for examining modified nanodiamond particles, examination...
-
Modified nanodiamond particle size studies by means of dynamic light scattering technique
PublikacjaThe Methods Utilizing the Phenomena of Light Scattering to Measure Particle Size distribution in different solvent, such as deionise water and alcohol and also to study the various structural formation when nanodiamond solution is placed on silicon surface. The purpose of this research project is divided into two parts to configure the measurement units for examining modified nanodiamond particles, examination...
-
Bacteriophages as potential tools for use in antimicrobial therapy and vaccine development
PublikacjaThe constantly growing number of people suffering from bacterial, viral, or fungal infections, parasitic diseases, and cancers prompts the search for innovative methods of disease prevention and treatment, especially based on vaccines and targeted therapy. An additional problem is the global threat to humanity resulting from the increasing resistance of bacteria to commonly used antibiotics. Conventional vaccines based on bacteria...
-
IDENTIFICATION OF DAMAGES OF TRIBOLOGICAL ASSOCIATIONS IN CRANKSHAFT AND PISTON SYSTEMS OF TWO-STROKE INTERNAL COMBUSTION ENGINES USED AS MAIN PROPULSION IN SEA-GOING VESSELS AND PROPOSAL OF PROBABILISTIC DESCRIPTION OF LOADS AS CAUSES OF THESE DAMAGES
PublikacjaThe article discusses damages of essential tribological associations in crankshaft and piston systems of large power two-stroke engines used as main engines, which take place during transport tasks performed by those ships. Difficulties are named which make preventing those damages impossible, despite the fact that the technical state of engines of this type is identified with the aid of complex diagnostic systems making use of...
-
DESIGN OF THE DUAL CONSTELLATION GPS/GALILEO MOBILE DEVICE FOR IMPROVING NAVIGATION OF THE VISUALLY IMPAIRED IN AN URBAN AREA, POLISH MARITIME RESEARCH
PublikacjaThe article discusses damages of essential tribological associations in crankshaft and piston systems of large power two-stroke engines used as main engines, which take place during transport tasks performed by those ships. Difficulties are named which make preventing those damages impossible, despite the fact that the technical state of engines of this type is identified with the aid of complex diagnostic systems making use of...
-
Collective action against same-sex marriages_online research in Poland
Dane BadawczeThe study was conducted in the context of people opposing the equality of sexual minorities. At the beginning of the survey, each respondent was asked to mark their support for the equality of rights of heterosexual and homosexual persons, on a scale from -3 (definitely not) to 3 (definitely yes). The subsequent questions of the survey were formulated...
-
Conjectured strong complementary-correlations tradeoff
PublikacjaWe conjecture uncertainty relations that restrict correlations between the results of measurements performed by two separate parties on a shared quantum state. The first uncertainty relation bounds the sum of two mutual informations when one party measures a single observable and the other party measures one of two observables. The uncertainty relation does not follow from the Maassen-Uffink uncertainty relation and is much stronger...