Filtry
wszystkich: 8431
-
Katalog
- Publikacje 6527 wyników po odfiltrowaniu
- Czasopisma 48 wyników po odfiltrowaniu
- Konferencje 5 wyników po odfiltrowaniu
- Wydawnictwa 1 wyników po odfiltrowaniu
- Osoby 150 wyników po odfiltrowaniu
- Wynalazki 3 wyników po odfiltrowaniu
- Projekty 6 wyników po odfiltrowaniu
- Laboratoria 3 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Kursy Online 487 wyników po odfiltrowaniu
- Wydarzenia 12 wyników po odfiltrowaniu
- Dane Badawcze 1188 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: OUT-OF-POCKET SPENDING
-
Two-dimensional simulations of concrete fracture at aggregate level with cohesive elements based on X-ray lCT images
PublikacjaThe paper presents results of two-dimensional meso-scale simulations of fracture in notched concrete beams subjected to three-point bending test. Concrete was assumed as a 4-phase material composed of aggregate grains placed in the cement matrix, interfacial transitional zones (ITZs) and macro-voids. The particle distribution was taken from real concrete beams on the basis of X-ray lCT images. Comprehensive numerical analyses were carried...
-
Dielectric properties of barium-vanadate glasses
Dane BadawczeThe linear impedance of barium-vanadate glasses was measured. Samples of the composition of xBaO-(100-x)V2O5 where x= 30, 40 and 45 (in %mol) were prepared by the conventional melt quenching technique. Appropriate amounts of reagents: BaO (≥99.9%, P.P.H STANLAB Sp.J.) and V2O5 (≥99.9%, POCH) were thoroughly mixed in an agate mortar. The melting was...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on one side- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl behind the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at buttocks, strengthening 2x smaller, drl at buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drl at the feet - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - one side of the bathtub is grounded, drl outside the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees, signal amplification x2 - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drills at the feet, grounding the bathtub - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on the measuring electrodes, drl outside the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on both sides, measuring electrodes on the front and back of the bathtub- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the water, measuring electrodes on the sides of the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath mass on the other - the person is moving- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl outside the bathtub on both sides- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in water, front and back measuring electrodes - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on measuring electrodes, drl in water - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath, the mass of the system on the other- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - conversation during measurement, electrodes on the sides of the bathtub, drl in water - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the bathtub, electrodes on the sides of the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, bath simulation - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - buttocks electrodes, reinforcement 2x smaller, drl on knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
A note on the affective computing systems and machines: a classification and appraisal
PublikacjaAffective computing (AfC) is a continuously growing multidisciplinary field, spanning areas from artificial intelligence, throughout engineering, psychology, education, cognitive science, to sociology. Therefore, many studies have been devoted to the aim of addressing numerous issues, regarding different facets of AfC solutions. However, there is a lack of classification of the AfC systems. This study aims to fill this gap by reviewing...
-
Robert Bogdanowicz dr hab. inż.
OsobyRobert Bogdanowicz received his Ph.D. degree with honours in Electronics from the Gdansk University of Technology. He worked as a post-doc researcher in Ernst-Moritz-Arndt-Universität Greifswald Institut für Physik. He has initiated optical emission imaging of muti-magnetron pulsed plasma and contributed to the development of antibacterial implant coatings deposited by high-power impulse magnetron sputtering. He moved back to...
-
Shielded HMSIW-based frequency-tunable self-quadruplexing antenna using different solid/liquid dielectrics
PublikacjaThis article proposes a frequency-tunable self-quadruplexing antenna based on a shielded half-mode substrate integrated waveguide (S-HMSIW). In order to reduce the size of the HMSIW cavity resonator and to obtain quad-band characteristics, a modied E-shaped slot is engraved on the top of the metal. The experimental validation is carried out after analyzing the data using a circuit model. Flexibility of each resonant frequency is...
-
The radiated immunity test of an astable multivibrator for various supply voltages
Dane BadawczeThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator supplied from a power supply with an output voltage of 6V and 7.5 V. Tests of immunity of electronic systems to radiated radio frequency (RF)...
-
Simulation model for evaluation of QOS dynamic routing
PublikacjaCurrent informational networks use a large variety of technologies to support data exchange. Most of them are focused on IP protocol and include mechanisms which by definition should supply demanded QoS. One of those mechanisms is efficient path calculation - routing. Traffic offered to the network can change very rapidly in short term. Routing should support such traffic changes and all the time calculate valid paths in terms...
-
Rozkład naprężeń mechanicznych w łyżce o szerokości 500 mm, przeznaczonej do koparki podsiębiernej
PublikacjaW artykule zaprezentowano optymalizację kształtu łyżki koparki przedsiębiernej z wykorzystaniem analizy wytrzymałościowej. Analizę oparto na trójwymiarowym modelu konstrukcji łyżki z zastosowaniem metody elementów skończonych (MES). Opracowanie wspomnianej metody pozwoliło na modyfikację konstrukcji łyżki, która dała w efekcie obniżenie naprężeń złożonych w newralgicznych obszarach konstrukcji łyżki. Przedstawiona analiza okazała...
-
La composition sur des lignes de fuite ou un équilibre manqué : le parti pris de l’espace dans les œuvres narratives d’Anna Langfus
Publikacja -
A New Rehabilitation Device for Balance Impaired Individuals
PublikacjaIn the paper authors present a device designed to improve the rehabilitation process of people with balance impairment. The discussed device (JStep) utilizes a commercially available static standing frame (stander) modified in order to fit force sensing units under the feet and in the pillows around the hips of a patient. While executing rehabilitation tasks, the patient may compensate his balance deficiency by leaning on the pillows...
-
Guanosine Dianions Hydrated by One to Four Water Molecules
PublikacjaIntermolecular interactions such as those present in molecule···water complexes may profoundly influence the physicochemical properties of molecules. Here, we carried out an experimental–computational study on doubly deprotonated guanosine monophosphate···water clusters, [dGMP – 2H]2–·nH2O (n = 1–4), using a combination of negative anion photoelectron spectroscopy (NIPES) with molecular dynamics (MD) and quantum chemical (QM) calculations....
-
Analytical Methods for Causality Evaluation of Photonic Materials
PublikacjaWe comprehensively review several general methods and analytical tools used for causality evaluation of photonic materials. Our objective is to call to mind and then formulate, on a mathematically rigorous basis, a set of theorems which can answer the question whether a considered material model is causal or not. For this purpose, a set of various distributional theorems presented in literature is collected as the distributional...
-
The radiated immunity test of an astable multivibrator in the frequency range from 100 MHz to 300 MHz
Dane BadawczeThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 100 MHz to 300 MHz were...
-
Results after grinding C45 steel
Dane BadawczeThe database contains results from nanoindenter, scanning microscope and also X-ray diffractometer. To determine the residual stresses and the size of the crystallites in the ferrite grains in the grinded surface layer, the Williamson Hall analysis of the X-ray diffraction patterns was performed. XRD diffraction patterns were also used to perform a...
-
Research on assessment of bolted joint state using elastic wave propagation
PublikacjaThe work contains results of experimental investigation of elastic wave propagation in a bolted single-lap joint. Tests were carried out for the excitation perpendicular to the connection plane. In experimental studies, PZT transducers were used for both excitation and registration of ultrasonic waves. The analyses took into account varying contact conditions between the elements of the connection depending on the value of the...
-
Green Chromatography: State-of-the-art, Opportunities and Future Perspectives
PublikacjaIt is well known that chromatographic procedures could have a significant impact on the environment if laboratory practice is not in line with the principles of green analytical chemistry (GAC). However, chromatographic techniques have the potential to be greener in all steps of the analysis. The approaches used to make chromatographic separations greener differ depending on the type of chromatographic method. This chapter considers...
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during maneuvering
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during maneuvering.
-
Satellite remote sensing - EMSS - 2022
Kursy OnlineThis course is designed for M.Sc. students of Space and Satellite Technologies, including HSB specialries Computer Science and Aerospace Technologies, within the specialty Engineering and Management of Space Systems (EMSS).
-
Satellite remote sensing - EMSS - 2023
Kursy OnlineThis course is designed for M.Sc. students of Space and Satellite Technologies, including HSB specialries Computer Science and Aerospace Technologies, within the specialty Engineering and Management of Space Systems (EMSS).
-
FE investigations of the effect of fluctuating local tensile strength on coupled energetic-statistical size effect in concrete beams
PublikacjaThe effect of fluctuating local tensile strength on a coupled energetic-statistical size effect in plain concrete beams under bending was numerically investigated. First, the influence of varying autocorrelation length of the random field describing a spatial variation of local tensile strength was studied. Next, the influence of the coefficient of variation of local tensile strength was analyzed. The numerical FE investigations...
-
Ocena możliwości emulacji protokołu RPR na sprzęcie klasy SOHO i systemie Linux
PublikacjaW pracy dokonano oceny możliwości realizacji protokołu RPR (Resilient Packet Ring - IEEE 802.17) na sprzęcie klasy SOHO i systemie Linux. Przedstawiono wytworzony na Politechnice Gdańskiej naukowo-dydaktyczny emulator stacji RPR zgodny z wersją 3.0 standardu. Funkcjonalność emulatora skupiono na algorytmach sprawiedliwości podziału pasma. Opisano sposób rozwiązania najważniejszych problemów związanych z implementacją, a w szczególności...
-
COMPARISON OF SOFTWARE AND HARDWARE REALIZATION OF AES CRYPTOGRAPHIC ALGORITHM
PublikacjaIn this paper hardware and software realization of direct and inverse AES cryptographic algorithm is presented. Both implementations were made using the Virtex-II FPGA and were practically tested. As the criteria of comparison, the resource utilization, achieved performance and power dissipation were chosen. Hardware realization increases throughput of conversion about 190 times over software implementation and decreases the energy...
-
Elderly persons professional activity - substantive issues and methodical challenges
PublikacjaPopulation ageing and mass withdrawal of persons around retirement age from the labour market constitutes a serious threat for European Union economy, especially in the so-called new member states. The coming years are expected to bring a considerable increase in public spending on pensions and health care, as well as changes in the structure and size of consumer demand and an increase in the number of socially excluded individuals....
-
Błażej Prusak dr hab.
OsobyBłażej Prusak jest kierownikiem Katedry Finansów na Wydziale Zarządzania i Ekonomii Politechniki Gdańskiej oraz redaktorem naczelnym czasopisma Research on Enterprise in Modern Economy - theory and practice (REME)/Przedsiębiorstwo we współczesnej gospodarce - teoria i praktyka, a także członkiem komitetów redakcyjnych takich czasopism jak: Intellectual Economics; Przestrzeń. Ekonomia. Społeczeństwo; Akademia Zarządzania. Jest autorem...