Wyniki wyszukiwania dla: MICROCOMPUTED TOMOGRAPHY
-
Problems of surface topography with oil pockets analysis
Publikacja -
Historická demografie (Historical Demography)
Czasopisma -
JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY
Czasopisma -
POPULATION STUDIES-A JOURNAL OF DEMOGRAPHY
Czasopisma -
The Optical Coherence Tomography and Raman Spectroscopy for Sensing of the Bone Demineralization Process
PublikacjaThe presented research was intended to seek new optical methods to investigate the demineralization process of bones. Optical examination of the bone condition could facilitate clinical trials and improve the safety of patients. The authors used a set of complementary methods: polarization-sensitive optical coherence tomography (PS-OCT) and Raman spectroscopy. Chicken bone samples were used in this research. To stimulate in laboratory...
-
Application of Electrical Capacitance Tomography for bulk solids flow analysis in silos
PublikacjaW artykule przedstawiono wyniki aplikacji metody ECT w analizie przepływów materiałów sypkich, zarówno bezkohezyjnych, jak również kohezyjnych. Omówiono podstawy techniczne metody ECT, przeprowadzono dyskusje parametrów zmiennych (zagęszczenie początkowe, szorstkość ścian).
-
Multilayered structures examination using polarization sensitive optical coherence tomography
PublikacjaW artykule przedstawiono wstępne wyniki badań struktur warstwowych z użyciem systemu optycznej tomografii koherentnej z analizą stanu poaryzacji (PS-OCT). Omówiono budowę systemu oraz zakres stosowalności metody do badania złożonych struktur warstwowych.
-
Analysis of the posibbility of detect determination using cold excitation in thermal tomography
Publikacja -
Novel method of lung area extraction in chest perfusion computed tomography
PublikacjaChest perfusion computed tomography (pCT) is a useful technique in the medical diagnosis of how organs function. Perfusion CT scans are used to calculate perfusion parameters. In the case of automated methods of lung perfusion parameters calculation, the prior extraction of the lung area is desired to avoid unnecessary calculation in an area outside the lung cross-section and to avoid wasting time on processing signals of no diagnostic...
-
Usefulness of chest perfusion computed tomography in the diagnosis of diabetic pulmonary microangiopathy
PublikacjaThis paper presents the usefulness of perfusion computed tomography (pCT) in the diagnosis of diabetic pulmonary microangiopathy. Our previous works have shown that perfusion parameters are useful in the diagnosis of diabetic pulmonary microangiopathy. We are looking for such measurements and perfusion parameters that provide the most accurate diagnosis. Two types of comparison were made based on the results of clinical trials:...
-
Comment on "Quantitative comparison of analysis methods for spectroscopic optical coherence tomography"
PublikacjaIn a recent paper by Bosschaart et al. [Biomed. Opt. Express 4, 2570 (2013)] various algorithms of time-frequency signal analysis have been tested for their performance in blood analysis with spectroscopic optical coherence tomography sOCT). The measurement of hemoglobin concentration and oxygen saturation based on blood absorption spectra have been considered. Short time Fourier transform (STFT) was found as the best method for...
-
Time-frequency analysis in optical coherence tomography for technical objects examination
PublikacjaOptical coherence tomography (OCT) is one of the most advanced optical measurement techniques for complex structure visualization. The advantages of OCT have been used for surface and subsurface defect detection in composite materials, polymers, ceramics, non-metallic protective coatings, and many more. Our research activity has been focused on timefrequency spectroscopic analysis in OCT. It is based on time resolved spectral analysis...
-
Ultrahigh-resolution detection techniques for biomedical applications of optical coherent tomography.
PublikacjaOptyczne metody pomiarowe odgrywają w ostatnich latach coraz większą rolę w badaniach i diagnostyce medycznej. Mają one szereg zalet, do których zaliczyć można odporność na promieniowanie elektromagnetyczne, bezinwazyjność, bezpieczeństwo pomiaru oraz wysoką rozdzielczość. Jedną z najważniejszych technik stosowanych w diagnostyce medycznej jest koherentna tomografia optyczna (OCT). Jest to wysokorozdzielcza metoda obrazowania wewnętrznych...
-
The Influence of Laser Alloying of Ti13Nb13Zr on Surface Topography and Properties
PublikacjaThe laser alloying is a continually developing surface treatment because of its significant and specific structuration of a surface. In particular, it is applied for Ti alloys, being now the most essential biomaterials` group for load-bearing implants. The present research was performed on the Ti13Nb13Zr alloy subject to laser modification in order to determine the treatment effects on surface topography and its some mechanical...
-
Modular impedance tomograph for shallow soil subsurface investigation.
PublikacjaW pracy przedstawiono konstrukcję i procedury pomiarowe konfigurowalnego systemu pomiarowego. Konstrukcja systemu oparta jest idei tzw. elektrody aktywnej, która zbudowana jest z wykorzystaniem mikrokontrolera ADuC 812.
-
Assessment of Wooden Beams from Historical Buildings Using Ultrasonic Transmission Tomography
PublikacjaThe main goal of this study was non-destructive evaluation of wooden elements using ultrasonic waves. The inspection was carried out on wooden beams from a historical object. Elastic wave signals were processed by ultrasonic transmission tomography to obtain imaging of the internal structure of tested elements without disturbing their state and integrity. The focus was on the influence of wood anisotropy on the propagation of ultrasonic...
-
Internal imaging of concrete fracture based on elastic waves and ultrasound computed tomography
PublikacjaThe condition assessment of concrete structures belongs to the greatest challenges of non-destructive testing. Monitoring the fracture process of concrete and detecting cracks at the earliest possible stage is a vital aspect to ensure the safety of civil engineering objects. The use of ultrasound tomography enables imaging the internal structure of a tested element. This study aims at the visualization of fracture damage in concrete...
-
Application of the X-ray micro computed tomography to the analysis of the structure of polymeric materials
PublikacjaIn this paper the application of X-ray micro-computed tomography (micro-CT) as a non-destructive testing method of polymeric materials is presented. Increasing applicability of polymers in variedend-use industries such as automotive, building and construction, consumer goods, and packaging is propelling the growth of the global polymer processing market. However, controlling of the polymer structure is one of the most important...
-
Use of X-Ray Computed Tomography for Ice Detection Applied to Organ Cryopreservation
Publikacja -
Ovarian tissue cryopreservation by stepped vitrification and monitored by X-ray computed tomography
Publikacja -
Quantitative active dynamic thermal ir-imaging and thermal tomography in medical diagnostics
PublikacjaPraca dotyczy nowych technik obrazowania w diagnostyce medycznej, wykorzystując przetwarzanie obrazów termicznych rejestrowanych w podczerwieni. Opisano właściwości termiczne tkanek biologicznych, omówiono medele termiczne i zdefiniowano zastępcze parametry syntetyczne, metody pomiarów i stosowane urządzenia. Omówiono procedury akwizycji danych i ich przetwarzania. Wprowadzono pojęcie tomografii termicznej. Opisano przeprowadzone...
-
Quantitative active dynamic thermal Ir-Imaging and thermal tomography in medical diagnostics
Publikacja -
A New Classification of the Morphology of Complete Ponticulus Posticus on Cone Beam Computed Tomography
Publikacja -
Role of quantitative chest perfusion computed tomography in detecting diabetic pulmonary microangiopathy
PublikacjaAims: Aimof the study was to determine the role of perfusion chest computed tomography(pCT) in evaluation of pulmonary diabetic angiopathy.Methods: 18 never-smoking patients (10 diabetic patients and 8 healthy controls) underwentchest high resolution CT (HRCT) and then pCT scanning. In both groups, blood tests,biochemical analysis, fibrinogen, HbA1c, spirometry, diffusion capacity for carbonmonoxide(DLCO) and body pletysmography...
-
Advanced Monte Carlo simulator of the polarization-sensitive optical coherence tomography systems
PublikacjaSimulations of the optical coherence tomography (OCT) systems using the Monte Carlo method is a widely explored research area. However, there are several difficulties that need to be overcome in order to properly model the OCT imaging with the Monte Carlo algorithm. First of all, the temporal and the spatial coherence of the scattered light need to be considered, since OCT is based on the interference phenomenon. For the same reason,...
-
Quantitative Active Dynamic Thermal IR-Imaging and Thermal Tomography in Medical Diagnostics
Publikacja.
-
Integration and verification of meteorological observations and NWP model data for the local GNSS tomography
PublikacjaGNSS meteorology applies the Global Navigation Satellite Systems (GNSS) to derive information about the state of the atmosphere (particularly troposphere). The tomography is one of the methods used in GNSS meteorology. The input data of GNSS tomography are the signal troposphere delays, results of GNSS data processing and additionally meteorological observations and Numerical Weather Prediction (NWP) models data. Different types...
-
Quantitative Active Dynamic Thermal IR-Imaging and Thermal Tomography in Medical Diagnostic
PublikacjaPrinciples of Active dynamic thermal (ADT) IR-imaging and Thermal Tomography are described in details. Basic medical applications of this new modality are also discussed.
-
The Effect of Valley Location in Two-Process Surface Topography Analysis
Publikacja -
<title>Synthesized light source for optical coherence tomograph</title>
Publikacja -
Imaging of Increasing Damage in Steel Plates Using Lamb Waves and Ultrasound Computed Tomography
PublikacjaThis paper concerns inspection of steel plates, with particular emphasis on the assessment of in-creasing damage. Non-destructive tests were performed on four plates, one of which was un-damaged, while the remaining three had a defects in the form of circular holes with a diameter of 2, 5, and 10 cm. Guided Lamb waves were used in the research, and the image reconstruction was performed using ultrasound computed tomography. The...
-
Using the ultrasonic tomography method to study the condition of wooden beams from historical buildngs
PublikacjaThe need to evaluate the integrity of wooden structural elements is constantly increasing. Non-destructive methods are becoming more popular in this field of research. One type of non-destructive testing is the ultrasonic imaging method, which allows the analysis of internal wood structures without disturbing their state and integrity. In this study, we are interested in assessing the effect of wood condition on the ultrasound...
-
Non-destructive inspection of anti-corrosion protective coatings using optical coherent tomography
PublikacjaW artykule przedstawiono zastosowanie optycznej tomografii koherentnej (OCT) do badania antykorozyjnych powłok ochronnych. Omówiono właściwości optycznej interferometrii niskokoherentnej jako zastosowanej metody pomiarowej, opisano budowę pomiarowego systemu OCT, zbudowanego w Katedrze Metrologii i Optoelektroniki WETI PG. Przy pomocy zrealizowanego systemu przebadano grupę powierzchni metalicznych pokrytych różnymi powłokami antykorozyjnymi....
-
Tome-lapse X-ray tomography imaging of flow patterns in versatile silo model
PublikacjaThe paper introduces a new versatile silo model that was especially designed for in situ X-ray tomography studies of silo discharge for various flow conditions, namely concentric and eccentric. The presented work focuses on organic granular materials where low fraction of short-grain white rice is mixed with spheroidal sorghum particles. The high-quality tomography images combined with adequate image processing strategy allows...
-
<title>Ultrahigh-resolution detection techniques for biomedical applications of optical coherent tomography</title>
Publikacja -
Measurement of selected characteristics of low-coherence optical signal sources for optical coherence tomography
Publikacja -
Fiber - optic low-coherence tomography system for visualization of internal structure of ceramic materials
PublikacjaW artykule przedstawiono światłowodowy system dwuwymiarowej wizualizacji niejednorodnych struktur warstw ceramicznych. Omówiono projekt i fizyczną realizację układu wykorzystującego optyczną, niskokoherentną reflektometrię optyczną, która umożliwia niedestrukcyjne obrazowanie wewnętrznych struktur różnych materiałów. W pracy przedstawiono przykładowe wyniki pomiarów wewnętrznych warstw LSFO.
-
<title>Modeling of broadband light source to use with optical coherent tomography system</title>
Publikacja -
Optical coherence tomography and magnetic resonance imaging visual pathway evaluation in Wolfram syndrome
Publikacja -
Novel approach to modeling spectral-domain optical coherence tomography with Monte Carlo method
PublikacjaNumerical modeling Optical Coherence Tomography (OCT) systems is needed for optical setup optimization, development of new signal processing methods and assessment of impact of different physical phenomena inside the sample on OCT signal. The Monte Carlo method has been often used for modeling Optical Coherence Tomography, as it is a well established tool for simulating light propagation in scattering media. However, in this method...
-
Anisotropy and compaction gradient assessment on rammed earth specimens through sonic tomography approach
PublikacjaRammed earth is a traditional construction technique that has recently gained attention because of its benefits from an ecological perspective. The conservation of the existing valuable cultural heritage sites and the quality control of new constructions built with this material require the development and application of practical inspection techniques. This paper explores the application of sonic tests and sonic tomography as...
-
Enhancing Renal Tumor Detection: Leveraging Artificial Neural Networks in Computed Tomography Analysis
PublikacjaRenal cell carcinoma is one of the most common cancers in Europe, with a total incidence rate of 18.4 cases per 100 000 population. There is currently significant overdiagnosis (11% to 30.9%) at times of planned surgery based on radiological studies. The purpose of this study was to create an artificial neural network (ANN) solution based on computed tomography (CT) images as an additional tool to improve the differentiation of...
-
Measurement of selected characteristics of low-coherence optical signal sources for optical coherence tomography
PublikacjaOCT to nowa metoda badania wewnętrznych struktur materiałów. Wśród wielu technik detekcji sygnału optycznego wykorzystywanych w OCT najpopularniejszą i najbardziej obiecującą jest OLCR (Opticla-Low Coherence Reflectomerty - reflektometria niskokoherentna). OLCR wykorzystuje szerokopasmowe źródła, których parametry, jak np.: charakterystyka widmowa, charakterystyka szumowa, determinują właściwości metrologiczne systemu OCT. W artykule...
-
Experimental investigations of fracture process in concrete by means of x-ray micro-computed tomography
PublikacjaW artykule pokazano doświadczalne wyniki badań procesu pękania w betonie stosując mikro-tomografię. Doświadczenia wykonano dla zginanych belek betonowych. Wyniki doświadczalne modelowano stosując MES na bazie modelu z degradacją sztywności sprężystej z nielokalnym osłabieniem. Beton symulowano jako materiał 4-fazowy. Uzyskano dobra zgodność wyników MES z doświadczeniami.
-
Parametric and nonparametric description of the surface topography in the dry and MQCL cutting conditions
Publikacja -
Errors of Surface Topography Parameter Calculation in Grinded or Turned Details Analysis
Publikacja -
Roughness Evaluation of Burnished Topography with a Precise Definition of the S-L Surface
Publikacja -
Resolving Selected Problems in Surface Topography Analysis by Application of the Autocorrelation Function
Publikacja -
Reduction of Influence of the High-Frequency Noise on the Results of Surface Topography Measurements
Publikacja -
The effect of valley depth on areal form removal in surface topography measurements
Publikacja