Filtry
wszystkich: 48
Wyniki wyszukiwania dla: AKCELEROMETR
-
Modelling an accelerometer for robot position estimation
PublikacjaThe article describes a new model of a MEMS accelerometer for usage in inertial measurement units (IMU). Such units allow to measure orientation and location of the sensor/system and therefore can be applied for systems positioning. The main purpose of the paper is to model pertinent accelerometer functions substantial in determination of the location of the sensor by means of double integration of acceleration. The model takes...
-
Evaluation of position estimation based on accelerometer data
PublikacjaThe paper concerns the problem of integrating data from accelerometers. A suitable model of a MEMS accelerometer is presented which is a part of inertial measurement units (IMU). Such units allow to measure orientation as well as to localize systems. They also appear to be applicable for systems positioning. The main purpose of the paper is to discuss conditions that must be satisfied to calculate the location of the sensor by...
-
Evaluating the mobile robot positions using accelerometer data
PublikacjaThis paper analyzes the problem of determining the position of a robot using an accelerometer, which is an essential part of inertial measurement units (IMU). The information gained from such a gauge, however, requires double integration of sensor data. To assure an expected effect, a mathematical model of a low-cost accelerometer of the MEMS type is derived. Moreover, in order to improve the performance of positioning based on...
-
STEVAL-MKI063V1, Przykład oprogramowania akcelerometrui magnetometru LSM303DLH
PublikacjaW artykule opisano moduł STEVAL-MKI1063V1 oparty na układzie LSM303DLHzawierającym akcelerometr i magnetometr oraz przedstawiono sposób komunikacji z nim z poziomu komputera PC na przykładzie aplikacji napisanej w języku C++/CLI (.NET).
-
Evaluating the position of a mobile robot using accelerometer data
PublikacjaThis paper analyses the problem of determining the position of a robot using an accelerometer, which is an essential part of inertial measurement units (IMU). The information gained from such a gauge, however, requires double integration of sensor data. To assure an expected effect, a mathematical model of a low-cost accelerometer of the MEMS type is derived. Moreover, in order to improve the performance of positioning based on...
-
Accelerometer signal pre-processing influence on human activity recognition
PublikacjaA study of data pre-processing influence on accelerometer-based human activity recognition algorithms is presented. The frequency band used to filter-out the accelerometer signals and the number of accelerometers involved were considered in terms of their influence on the recognition accuracy.
-
Accelerometer-based Human Activity Recognition and the Impact of the Sample Size
PublikacjaThe presented study focused on the recognition of eight user activities (e.g. walking, lying, climbing stairs) basing on the measurements from an accelerometer embedded in a mobile device. It is assumed that the device is carried in a specific location of the user’s clothing. Three types of classifiers were tested on different sizes of the samples. The influence of the time window (the duration of a single trial) on selected activities...
-
Estimation of respiration rate using an accelerometer and thermal camera in eGlasses
PublikacjaRespiration rate is a very important vital sign. Different methods of respiration rate measurement or estimation have been developed. However, especially interesting are those that enable remote and unobtrusive monitoring. In this study, we investigated the use of smart glasses for the estimation of respiration rate especially useful for indoors applications. Two methods were analyzed. The first one is based on measurements of...
-
Influence of accelerometer signal pre-processing and classification method on human activity recognition
PublikacjaA study of data pre-processing influence on accelerometer-based human activity recognition algorithms is presented. The frequency band used to filter-out the accelerometer signals and the number of accelerometers involved were considered in terms of their influence on the recognition accuracy. In the test four methods of classification were used: support vector machine, decision trees, neural network, k-nearest neighbor.
-
Visualization and quantification of lab vibratory compacting process for aggregate base materials using accelerometer
Publikacja -
Bezprzewodowy trójpłaszczyznowy kontroler położenia
PublikacjaW pracy przedstawiono system pomiarowy pozwalający na określenie położenia. Moduł elektroniczny wykorzystuje mikroprocesor ATmega oraz akcelerometr wykonany w technologii MEMS. Komunikację między modułem a komputerem PC zrealizowano łączem bezprzewodowym. Przygotowane zostało dedykowane oprogramowanie. Program mikrokontrolera odczytuje dane z akcelerometru i łączem radiowym wysyła je do komputera. Oprogramowanie komputera PC dokonuje...
-
Feasibility Study for Food Intake Tasks Recognition Based on Smart Glasses
PublikacjaIn this exploratory study 13 adult test subjects have performed different food intake tasks while wearing a three axis accelerometer mounted at a temple of glasses. Two different algorithms for task recognition have been applied and compared. The retrospective data processing leads to better task recognition results when the frequency range of 50 Hz to 100 Hz is analysed within accelerometer signal recordings. A straightforward...
-
Using Alpha-beta filtration for robustness improvement of a quadrocopter positioning system
PublikacjaQuadrocopter is an unmanned aerial vehicle (UAV) platform. The position of the robot is determined based on readings from an accelerometer and a gyroscope, but the measurement signals contain broadband noise. This article describes a solution for filtering out the noise based on an Alpha – beta filter. It also presents the methodology of designing and implementing such a filter for noise cancellation in measurement signals from...
-
Sensors integration in the smart home environment - a proposal to solve the problem with user identification
PublikacjaIn this preliminary study we, investigate the possibility of user recognition techniques suitable on smart home devices like chairs, beds, aiming for low–power, high accuracy and quick response time. We propose the two well know technique: voice speaker recognition and accelerometer signal from device mounted on the chair, and the third one optical system basing on IR LED transmitter/receiver circuit. The preliminary results proved...
-
A method of vibration surveillance with a use of the optimal control at energy performance index and the acceleration feedback
PublikacjaDokonano twórczej modyfikacji metody nadzorowania drgań za pomocą sterowania optymalnego przy energetycznym wskaźniku jakości. Zaproponowano oryginalną modyfikację, która polega na bezpośrednim powiązaniu sygnału pomiarowego z akcelerometru i optymalnego sygnału sterującego. Przewidziano obiecujące perspektywy zastosowań praktycznych zmodyfikowanej metody do przypadków frezowania szybkościowego.
-
Zestaw STEVAL PCC009V1 i biblioteki Universal Dongle
PublikacjaW artykule przedstawiono zestaw STEVAL PCC009V1 i dołączone do niego biblioteki programistyczne Universal Dongle. Sposób ich wykorzystania pokazano na przykładzie komunikacji z akcelerometrem ST LIS35DE.
-
Real‐Time PPG Signal Conditioning with Long Short‐Term Memory (LSTM) Network for Wearable Devices
PublikacjaThis paper presents an algorithm for real‐time detection of the heart rate measured on a person’s wrist using a wearable device with a photoplethysmographic (PPG) sensor and accelerometer. The proposed algorithm consists of an appropriately trained LSTM network and the Time‐Domain Heart Rate (TDHR) algorithm for peak detection in the PPG waveform. The Long Short‐Term Memory (LSTM) network uses the signals from the accelerometer...
-
Pomiary w diagnostyce łożysk silników indukcyjnych
PublikacjaOmówiono badania, dotyczące diagnostyki łożysk silników z wykorzytaniem pomiarów wibracji (akcelerometrem piezoelektrycznym i laserowym) oraz prądu silnika. Przedstawiono wyniki badań, świadczące o przydatności pomiarów wielkości elektrycznych w silniku do diagnostyki łożysk.
-
Automatyczny system pomiarów przyciągania
PublikacjaW artykule opisano system pomiarowy przeciążeń występujących podczas ruchu kończyn. System składa się z zestawu akcelerometrów podłączonych przez kartę pomiarową do komputera. Proponowany system można użyć np. jako pomoc w diagnostyce lekarskiej.
-
Photoplethysmographic Time-Domain Heart Rate Measurement Algorithm for Resource-Constrained Wearable Devices and its Implementation
PublikacjaThis paper presents an algorithm for the measurement of the human heart rate, using photoplethysmography (PPG), i.e., the detection of the light at the skin surface. The signal from the PPG sensor is processed in time-domain; the peaks in the preprocessed and conditioned PPG waveform are detected by using a peak detection algorithm to find the heart rate in real time. Apart from the PPG sensor, the accelerometer is also used to...