Filters
total: 2877
filtered: 112
-
Catalog
Chosen catalog filters
Search results for: FABRIC GEOMETRY MEASUREMENT
-
Results and models for Novel high frequency components with non-conventional shape employing smooth geometry deformation of 3D solid with FFD
Open Research DataThe project aims to investigate the possibility of developing and manufacturing novel high frequency devices having non-standard geometries, allowing for improved electromagnetic performance over what is achievable with currently available design tools. The non-conventional geometry will be obtained by employing the free-form shape deformation technique...
-
EH36 steel for shipbuilding (plate thicnkness 30 mm) - 3D fracture scan
Open Research DataThe basic method of ductility designation of structural steels is the Charpy impact test. The test consists of a single strike of the specimen using a Charpy pendulum. Its result is the value of work necessary to break a specimen at a test temperature. Despite its many advantages, such as its short implementation time and low costs, it has its disadvantages,...
-
Molecular geometry of hexachlorobenzene
Open Research DataPresented data shows molecular geometry of the ground singlet state of hexachlorobenzene and hexachlorobenzene with potassium atom in 10 angstrom distance. The geometry was obtained via MP2 and CCSD calculations using balanced polarized triple-zeta def2-TZVP basis set. Geometry is provided in the XYZ file format.
-
Molecular geometry of phenylboronic acid
Open Research DataData presents molecular geometry of the ground singlet state of phenylboronic acid. The geometry was obtained via DFT calculations using Becke–Lee–Yang–Parr density functional (B3LYP) with the balanced polarized triple-zeta def2-TZVP basis set. Geometry is provided in the XYZ file format.
-
The loop impedance measurement
Open Research DataThe loop impedance measurement
-
Long-term measurement of physiological parameters.
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (up to 90 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - adult (120 minutes)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (60 minutes)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Light transmission measurement through the fluidized bed photoreactor
Open Research DataDataset contains light transmission measurements through the fluidized bed photoreactor. Two sources of light were used: UV-LEDs and UV fluorescent. Measurements were performed at different air flows: 0, 80, 160 and 240 ml/min. The detailed measurement and equipment data was described in measurment info.txt file.
-
Distance measurement by the low coherent interferometer
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1560 nm, an optical spectrum analyzer and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Adsorption and desorption of N2 measurement of MXenes catalysts
Open Research DataData contain results from adsorption and desorption of N2 measurement of the Ti3C2Tx MXenes produced via acidic etching aluminum from MAX Phase (Ti3C2-Al-Ti3C2-Al-Ti3C2) using different etching agents, HF/HCl and HF/H2SO4 with different weight ratios (1:3, 1:4, and 1:5). The samples were labeled as MXene HF/HCl X:Y and MXene HF/H2SO4 X:Y, where X:Y...
-
Long-term measurement of physiological parameters - a teenager (105 minutes)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (105 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (100 minutes)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (100 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - an adult (100 minutes)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (100 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - an adult (70 minutes)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (70 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 min)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - an adult (60 minutes)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (120 min)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (120 minutes) measurement of physiological parameters was performed on the healthy...
-
Experimental Study of the Influence of Noise Level on the Uncertainty Value in a Measurement System Containing an Analog-to-Digital Converter
Open Research DataFor newly developed measuring systems it is easy to estimate type B uncertainties based on the technical data of the measuring modules applied. However, it is difficult to estimate A type un-certainties due to the unknown type and level of interferences infiltrating into the measuring sys-tem. This is a particularly important problem for measurements...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) - the 2nd serie
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Impedance spectra of RC model as a result of testing pulse excitation measurement method
Open Research DataThe impedance spectrum of RC model object obtained using pulse excitation EIS impedance spectrosocpy measurement method. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. The object under test was built using RC components connected as Baunier model of anticorrosion coating with the following components...
-
Measurement of the temporal and spatial temperature distribution on the surface of PVCP tissue phantom illuminated by laser.
Open Research DataApplication of laboratory set-up for characterisation of thermal properties of optical tissue phantoms during laser irradiation is presented. The produced system utilizes thermographic camera VIGOcam v50 and dermatological laser system with a 975 nm diode laser module. The set-up was used to perform measurements of the temporal and spatial temperature...
-
The voltage across and current through the RC model object tested using pulse excitation in impedance spectroscopy measurement method
Open Research DataThe raw data (voltage across and current through RC model object ) obtained using pulse excitation EIS impedance spectroscopy measurement method. The data was acquired using 12-bit ADC (LTC1420) with sampling frequency changed in time segments. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. For...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 130 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 110 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 120 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Technical fabrics old sample
Open Research DataThe data presented here includes video of technical fabric strength testing. The included movie is in .cine format, and an external program with a viewer for such movies is required.
-
Two-phase water-air flow measurement using gamma-ray absorption technique – plug flow
Open Research DataThe attached datasets contains the measurement results of the air-water flow in a horizontal pipeline. Flow type: plug flow. The data shows the pulse counts of the two radiometric sets. Each of these kits consisted of a QSA Global Am-241 gamma ray source and a Tesla SKG-1 type NaI(Tl) scintillation probe. The pulses were recorded using a dedicated EC...
-
Two-phase water-air flow measurement using gamma-ray absorption technique – slug flow
Open Research DataThe attached datasets contains the measurement results of the air-water flow in a horizontal pipeline. Flow type: slug flow. The data shows the pulse counts of the two radiometric sets. Each of these kits consisted of a QSA Global Am-241 gamma ray source and a Tesla SKG-1 type NaI(Tl) scintillation probe. The pulses were recorded using a dedicated EC...
-
Two-phase water-air flow measurement using gamma-ray absorption technique –bubble flow
Open Research DataThe attached datasets contains the measurement results of the air-water flow in a horizontal pipeline. Flow type: bubble flow. The data shows the pulse counts of the two radiometric sets. Each of these kits consisted of a QSA Global Am-241 gamma ray source and a Tesla SKG-1 type NaI(Tl) scintillation probe. The pulses were recorded using a dedicated...
-
Two-phase water-air flow measurement using gamma-ray absorption technique – transitional plug – bubble flow
Open Research DataThe attached datasets contains the measurement results of the air-water flow in a horizontal pipeline. Flow type: transitional plug – bubble flow. The data shows the pulse counts of the two radiometric sets. Each of these kits consisted of a QSA Global Am-241 gamma ray source and a Tesla SKG-1 type NaI(Tl) scintillation probe. The pulses were recorded...
-
Short-term measurement of physiological parameters - child (2)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Reinforced aluminium reference measurement R63 – earlier tests
Open Research DataPreliminary testing of aluminium alloys against 100Cr6 steel ball. Preparation to tests on wear of Al6061 alloy in ball on disk experiment. Research on the reinforcing effect of aluminium alloy injection reinforcement with TiN and WC powders in laser remelted surface layer.
-
Reinforced aluminium reference measurement Result1 – earlier tests
Open Research DataPreliminary testing of aluminium alloys against 100Cr6 steel ball. Preparation to tests on wear of Al6061 alloy in ball on disk experiment. Research on the reinforcing effect of aluminium alloy injection reinforcement with TiN and WC powders in laser remelted surface layer.
-
XRD patterns of MXenes ashes obtained after TGA measurement
Open Research DataData contain results from XRD measurements of the product (ashes) produced after TGA of MAX Phase, MXene HF, MXene HF/HCl 1:3 and MXene HF/H2SO4 1:3 . The measurements were performed in AERIS PANalytical X-ray diffractometer with Cu-Ka radiation.
-
UAV Survey Images - DTM - Sopot Tombolo (Salient) Measurement - MP2
Open Research DataDataset description: Raw images from photogrammetric survey. Object: littoral zone in SopotLocation: Sopot, Pomerania, PolandDrone type: DJI Mavic Pro 2Flight plan: Single GridTarget Product: Digital Terrain ModelDate: 23.11.2019Direct georeferencing: yesMetadata data: yes/GPSGCP: YESGCP Quality: RTKCamera Name: Hasselblad L1D-20cModel type: PerspectiveImage...
-
Interactions of PDA tetramers with the Au surfaces
Open Research DataThis dataset contains electrostatic difference potential (EDP) maps, density of states (DOS) spectra, and adsorption geometries of cyclic tetramers on the Au surface. The real polydopamine was modelled either as the cyclic tetramers in the oxidised (indolequinone, IQ) and reduced (dihydroxyindole, DHI) chemistries with all units being the same - either...
-
Gdańsk 2019 Jana z Kolna street - video data
Open Research DataGdańsk 2019 Jana z Kolna street - video data
-
SEM-EDS images of expanded polystyrene spheres coated with silicon dioxide (SiO2) and/or titanium dioxide (TiO2)
Open Research DataData contain SEM and SEM-EDS images of expanded polystyrene spheres coated with silicon dioxide (SiO2) and/or titanium dioxide (TiO2). The detailed equipment and measurement data was described in measurement info.txt file.
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 140 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 160 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 180 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 220 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 200 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-0optic sensor - 250 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 210 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 300 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 270 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 190 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 260 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...