Filters
total: 14148
filtered: 10680
-
Catalog
- Publications 10680 available results
- Journals 87 available results
- Conferences 15 available results
- Publishing Houses 1 available results
- People 122 available results
- Projects 1 available results
- Research Equipment 1 available results
- e-Learning Courses 92 available results
- Events 8 available results
- Open Research Data 3141 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: BLOOD PRESSURE, PULSE TRANSIT TIME, NONINVASIVE MEASUREMENTS, SAMPLING FREQUENCY, LOW PASS FILTER
-
Blood Pressure celebrates 20 years of dedication to Nordic hypertension research
Publication -
Assessment of Supercapacitor’s Quality by Means of Low Frequency Noise
PublicationLow frequency noise is a well-known tool for quality and reliability assessment of electronic devices. This phenomenon is observed in different electrochemical devices as well (e.g., smart windows, electrochemical corrosion processes). Thus, we can assume that the same tool can be used to asses quality of supercapacitors. Their quality is usually determined only by capacitance and/or equivalent series resistance (ESR), or impedance....
-
Ladder-Based Synthesis and Design of Low-Frequency Buffer-Based CMOS Filters
PublicationBuffer-based CMOS filters are maximally simplified circuits containing as few transistors as possible. Their applications, among others, include nano to micro watt biomedical sensors that process physiological signals of frequencies from 0.01 Hz to about 3 kHz. The order of a buffer-based filter is not greater than two. Hence, to obtain higher-order filters, a cascade of second-order filters is constructed. In this paper, a more...
-
Coupled-Resonator Waveguide Filter in Quadruplet Topology With Frequency-Dependent Coupling - A Design Based on Coupling Matrix
PublicationThis letter presents an application of a recently developed coupling matrix synthesis technique to design of coupled-resonator filters with dispersive inter-resonator couplings. This technique is used to design a novel coupled-cavity bandpass filter. Measurements validate the design and confirm effectiveness of the synthesis method. The filter is a four-pole generalized Chebyshev filter with three transmission zeros. Resonators...
-
CMOS implementation of an analogue median filter for image processing in real time
PublicationAn analogue median filter, realised in a 0.35 μm CMOS technology, is presented in this paper. The key advantages of the filter are: high speed of image processing (50 frames per second), low-power operation (below 1.25 mW under 3.3 V supply) and relatively high accuracy of signal processing. The presented filter is a part of an integrated circuit for image processing (a vision chip), containing: a photo-sensor matrix, a set of...
-
A Substrate Integrated Waveguide (SIW) Bandpass Filter in A Box Configuration With Frequency-Dependent Coupling
PublicationThis letter presents the design of a microwave bandpass filter with frequency-dependent coupling implemented in substrate integrated waveguide (SIW) technology. The proposed filter implements a four-pole generalized Chebyshev filtering function with two transmission zeros. Resonators are arranged in an extended box configuration with dispersive coupling on a main signal path, which produces an extra zero in comparison to classical...
-
On various modelling approaches to real-time visualisation of blood flow
PublicationThis paper reviews various modelling approaches to real-time visualisation of blood flow. These include classic, macroscale approach based on the momentum conservation equation together with a proper constitutive equation. Moreover, modern micro- and mesoscale approaches, such as molecular dynamics and dissipative particle dynamics, are discussed. Advantages and disadvantages of the discussed methods are highlighted with particular...
-
Challenges in oscillometric blood pressure measurement in atrial fibrillation: looking for practical solutions
Publication -
More is Less? Optimal Combination Therapy for Adequate Blood Pressure Lowering in Hypertension
Publication -
Multiple output differential OTA with linearizing bulk-driven active-error feedback loop for continuous-time filter applications
PublicationA CMOS circuit realization of a highly linear multiple-output differential operational transconductance amplifier (OTA) has been proposed. The presented approach exploits a differential pair as an input stage with both the gate and the bulk terminals as signal ports. For the proposed OTA, improved linearity is obtained by means of the active-error feedback loop operating at the bulk terminals of the input stage. SPICE simulations...
-
Mild poikilocapnic hypoxia increases very low frequency haemoglobin oxygenation oscillations in prefrontal cortex
PublicationBackground: The aim of the study was to investigate the effect of mild cerebral hypoxia on haemoglobin oxygenation(HbO2), cerebrospinal fluid dynamics and cardiovascular physiology. To achieve this goal, four signals were recorded simultaneously: blood pressure, heart rate / electrocardiogram, HbO2 from right hemisphere and changes of subarachnoid space (SAS) width from left hemisphere. Signals were registered from 30 healthy,...
-
Bandwidth-Controllable Third-Order Band Pass Filter Using Substrate Integrated Full- and Semi-Circular Cavities
PublicationThe article presents a novel circular substrate integrated waveguide (SIW) bandpass filter (BPF) with controllable bandwidth. The proposed BPF is configured using two microstrip feedlines, semi- circular SIW cavities, capacitive slots, and inductive vias. The circular cavity is bisected into two halves, with the two copies thereof being cascaded. Two bisected and cascaded structures obtained this way are subsequently connected...
-
Detection and time/frequency analysis of electric fields in the ground
PublicationThis paper sets out to detect and characterize electric fields in the ground (such as stray current fields) using a tandem time/frequency method of signal analysis. Results were obtained from investigations performed in the presence of a generated electric field with controlled variable characteristics, and in the presence of an electric field generated by a tramline. The analysis of measurement registers was performed using Short‐Time...
-
Validation of atmospheric aerosols sampling in equivalent fractions
PublicationPhysical properties and chemical composition of atmospheric aerosols are of extreme importance, in many fields of interest, namely the Environment even with legal implications. Atmospheric sampling poses inherent problems with consequent demands on sampling optimisation, with sampling strategies requiring validation. In this work a study was conducted aiming at validating the collection of atmospheric aerosols in equivalent fractions....
-
A novel method of time-frequency analysis: an essential spectrogram
PublicationA novel precise method of time-frequency analysis is presented. In the algorithm, a new energy distribution is estimated by simultaneously discard or displacement of the classical spec- trogram energy. A channelized instantaneous frequency and a local group delay are used in order to replacement in the same manner as formulated by Kodera et al. [1, 2]. Additionally, new representations: a channelized instantaneous bandwidth and...
-
The accuracy of pulse rate estimation from the sequence of face images
PublicationThe goal of this paper is to analyze the accuracy of pulse rate estimation from the sequence of face images. Simulated and real signals were used to evaluate two pulse rate estimators; one for frequency domain and the second one for time domain using the autocorrelation function. The results show that the mean difference between the reference measurements and estimated pulse rate values are about 2bpm. In the analysis of short...
-
Sampling Strategies: Statistics of Sampling
PublicationEach step of the analytical procedure has a significant influence on the final result of the analysis. In the majority of cases the analytical procedure encompasses sampling because the analysis of the entire object (material) is usually not possible. Thus it is necessary to include the uncertainty related to sampling procedure in the uncertainty budget calculations. In the paper: the most important properties of the analysed...
-
Miniaturized bandpass substrate integrated waveguide filter with frequency-dependent coupling realized using asymmetric GCPW discontinuity
PublicationAn asymmetric GCPW discontinuity is proposed to provide frequency-dependent coupling in microwave bandpass filters. Wider and narrow sections introduce, respectively, the capacitive and inductive component to the equivalent circuit representing coupling. By selecting the dimensions of the discontinuity and width of the inductive window in substrate integrated waveguide, an additional transmission zero can be introduced at prescribed...
-
Derivation of motor mean phase currents in PMSM drives operating with low switching-to-fundamental frequency ratio
PublicationPulse width modulation (PWM) of inverter output voltage causes the waveforms of motor phase cur-rents to consist of distinctive ripples. In order to provide suitable feedback for the motor current con-trollers, the mean value must be extracted from the currents’ waveforms in every PWM cycle. A com-mon solution to derive the mean phase currents is to sample their value at the midpoint of a symmetrical PWM cycle. Using an assumption...
-
Chirp-rate estimation of FM signals in the time-frequency domain
PublicationNovel dynamic representations of a complex signal in the time-frequency domain including: a channelized instantaneous complex frequency (CICF), a complex local group delay (CLGD) and a channelized instantaneous chirp-rate (CICR) are introduced. The proposed approach is based on the use of the gradient of the short-time Fourier transform complex phase. An interpretation of the newly-introduced distributions especially of the CICR...
-
Error analysis of calculating average d-q current components using Regular Sampling and Park transformation in FOC drives
PublicationIn electric drives using voltage source inverters, motor currents contain ripple component resulting from pulse-width modulated (PWM) voltage. The frequency range of the ripples is much higher than the bandwidth of current control. Therefore the control is performed on the basis of a fundamental current component, i.e. average value with the averaging time being the PWM period. In majority of cases the average current is measured...
-
Blood pressure and low-density lipoprotein-cholesterol lowering for prevention of strokes and cognitive decline
Publication -
The hydrodynamic pressure field of the ship Zodiak, measurements and calculations
PublicationThe article presents the results of measurements of the slowly changing hydrodynamic pressure field HPF generated by the movement of the ship, Zodiak, in the Bay of Gdansk. The measurement results have been obtained in the framework of the program of the work in Siramis, under the auspices of the European Defence Administration of the EU, by the research team of the Naval Academy in Gdynia. The measurement results were compared with...
-
Longitudinal tracking of muscle sympathetic nerve activity and its relationship with blood pressure in subjects with prehypertension
Publication -
Impact of slow breathing on the blood pressure and subarachnoid space width oscillations in humans
PublicationThe aim of the study was to assess cardiac and respiratory blood pressure (BP) and subarachnoid space (SAS) width oscillations during the resting state for slow and fast breathing and breathing against inspiratory resistance. Experiments were performed on a group of 20 healthy volunteers (8 males and 12 females; age 25.3 ± 7.9 years; BMI = 22.1 ± 3.2 kg/m2). BP and heart rate (HR) were measured using continuous finger-pulse photoplethysmography....
-
Combined analysis of whole human blood parameters by Raman spectroscopy and spectral-domain low-coherence interferometry
PublicationIn this article the simultaneous investigation of blood parameters by complementary optical methods, Raman spectroscopy and spectral-domain low-coherence interferometry, is presented. Thus, the mutual relationship between chemical and physical properties may be investigated, because low-coherence interferometry measures optical properties of the investigated object, while Raman spectroscopy gives information about its molecular...
-
Low-frequency tripping characteristics of residual current devices
PublicationFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
A nine-input 1.25 mW, 34 ns CMOS analog median filter for image processing in real time
PublicationIn this paper an analog voltage-mode median filter, which operates on a 3 × 3 kernel is presented. The filter is implemented in a 0.35 μm CMOS technology. The proposed solution is based on voltage comparators and a bubble sort configuration. As a result, a fast (34 ns) time response with low power consumption (1.25 mW for 3.3 V) is achieved. The key advantage of the configuration is relatively high accuracy of signal processing,...
-
High Signal Resolution Pulse Oximetry as a Prognostic Indicator of Radiotherapy Toxicity: A Pilot Study
PublicationIntroduction: Radiotherapy plays a prominent role in the multidisciplinary treatment of cancers. Despite new irradiation techniques, radiation-induced cardiotoxicity remains a leading cause of morbidity and mortality. Therefore, prognostic indicators of radiotherapy toxicity are essential. This study aimed to investigate the influence of applied radiotherapy on the pulse wave recording and thereby on...
-
Time-frequency analysis of acoustic signals using concentrated spectrogram
PublicationThe paper presents improved method of time-frequency (TF) analysis of discrete-time signals. The method involves signal's local group delay (LGD) and channelized instantaneous frequency (CIF) to purposely redistribute all Short-time Fourier transform (STFT) lines. Additionally, the energy concentration index (ECI) and some histogram-like statistics are used to evaluate readability of estimated TF distributions of the energy. Recorded...
-
Increased inspiratory resistance affects the dynamic relationship between blood pressure changes and subarachnoid space width oscillations
PublicationBackground and objective Respiration is known to affect cerebrospinal fluid (CSF) movement. We hypothesised that increased inspiratory resistance would affect the dynamic relationship between blood pressure (BP) changes and subarachnoid space width (SAS) oscillations. Methods Experiments were performed in a group of 20 healthy volunteers undergoing controlled intermittent Mueller Manoeuvres (the key characteristic of the procedure...
-
Pulse pressure amplification in relation to body fatness
Publication -
A Special Multi-Pulse Converter with Small Active Power Filter
Publication -
Supine blood pressure normalised by daytime series values is independently associated with ischaemic wake-up stroke
Publication -
Blood pressure lowering effect of renal sympathetic denervation or placebo? - building expectations for Symplicity-HTN 3
Publication -
Ambulatory Blood Pressure Adds to Explaining Benefits of AT‐1 Receptor Blockade in the Treatment of Left Ventricular Hypertrophy
Publication -
High-normal blood pressure is associated with increased resting sympathetic activity but normal responses to stress tests
Publication -
Effects of laser pulse duration in two-photon vision threshold measurements
PublicationPulsed near-infrared (NIR) light sources can be successfully applied for both imaging and functional testing of the human eye, as published recently1. These two groups of applications have different requirements. For imaging applications, the most preferable is invisible scanning beam while efficiently visible stimulating beam is preferable for functional testing applications. The functional testing of human eye using NIR laser...
-
A Trisection Filter Design With Negative Slope of Frequency-Dependent Crosscoupling Implemented in Substrate Integrated Waveguide (SIW)
PublicationThis letter reports on a novel realization of a microwave bandpass filter in a triplet configuration with a frequency-dependent crosscoupling implemented in substrate integrated waveguide (SIW). The design involves implementing dispersive coupling with a negative slope, a feature that allows the capabilities of the classic triplet topology to be extended. In this particular case, the implementation of two transmission zeros on...
-
Highly-Compact Dual-Band Bandpass Waveguide Filter Based on Cross-Shaped Frequency-Dependent Coupling
PublicationThis work reports the design of an original class of highly-compact dual-band bandpass filter based on dual-mode waveguide resonators inter-coupled through a novel type of frequency-dependent coupling (FDC). The devised FDC consists of a cross-shaped metallic structure placed in the broad wall of a rectangular waveguide. This FDC produces two additional poles and three extra transmission zeros (TZs). Specifically, each pole is...
-
Broad Stopband, Low-Loss, and Ultra-Compact Dual-Mode Bandpass Filter Based on HMSIRC
PublicationIn this investigation, an ultra-compact dual-mode bandpass filter (BPF) with a wide stopband re-sponse is realized by using a half-mode substrate-integrated rectangular cavity (HMSIRC). The HMSIRC resonator is designed with a cavity that is rectangular in shape and has metallic vias along three of the sides. The fourth side is open-ended and contains microstrip feed lines. For the purpose of constructing a magnetic wall, a rectangular...
-
A review of design approaches for the implementation of low-frequency noise measurement systems
PublicationElectronic noise has its roots in the fundamental physical interactions between matter and charged particles, carrying information about the phenomena that occur at the microscopic level. Therefore, Low-Frequency Noise Measurements (LFNM) are a well-established technique for the characterization of electron devices and materials and, compared to other techniques, they offer the advantage of being non-destructive and of providing...
-
Uniform sampling in constrained domains for low-cost surrogate modeling of antenna input characteristics
PublicationIn this letter, a design of experiments technique that permits uniform sampling in constrained domains is proposed. The discussed method is applied to generate training data for construction of fast replacement models (surrogates) of antenna input characteristics. The modeling process is design-oriented with the surrogate domain spanned by a set of reference designs optimized with respect to the performance figures and/or operating...
-
Inline Microstrip Bandpass Filter With Two Transmission Zeros and Increased Order Using Spurious Resonance of Frequency-Dependent Inverter
PublicationA design method for a class of fourth-order inline microstrip bandpass filter with two transmission zeros and 20% fractional bandwidth is presented. The filter consists of two quarter-wavelength transmission-line resonators coupled by a frequency-dependent inverter. The inverter is composed of two open-ended stubs that are connected by an interdigital capacitor and introduces two poles and two transmission zeros in the filter response....
-
Twenty‐four‐hour and conventional blood pressure components and risk of preterm delivery or neonatal complications in gestational hypertension
Publication -
High mortality explained by mildly elevated blood pressure in Scandinavian adolescent conscripts – A plea for early drug treatment?
Publication -
Urgent need to address quality control issues of out‐of‐office blood pressure measurement and patient risk assessment
Publication -
A fast time-frequency multi-window analysis using a tuning directional kernel
PublicationIn this paper, a novel approach for time-frequency analysis and detection, based on the chirplet transform and dedicated to non-stationary as well as multi-component signals, is presented. Its main purpose is the estimation of spectral energy, instantaneous frequency (IF), spectral delay (SD), and chirp rate (CR) with a high time-frequency resolution (separation ability) achieved by adaptive fitting of the transform kernel. We...
-
Device characteristics extraction by low frequency noise measurements; Someresults on the state-of-the-art MOSFET´s
PublicationPrzedstawiono wyniki pomiarów i analizy szumów tranzystorów MOSFET z izolatorem bramki wykonanym z SiO2 i HfO2. Wyniki pomiarów wykorzystano do oszacowania gęstości aktywnych stanów na powierzchni użytego tlenku i porównano z wynikami otrzymanymi metodą charge-pumping.
-
Time-frequency analysis in optical coherence tomography for technical objects examination
PublicationOptical coherence tomography (OCT) is one of the most advanced optical measurement techniques for complex structure visualization. The advantages of OCT have been used for surface and subsurface defect detection in composite materials, polymers, ceramics, non-metallic protective coatings, and many more. Our research activity has been focused on timefrequency spectroscopic analysis in OCT. It is based on time resolved spectral analysis...