Filters
total: 14482
filtered: 10862
-
Catalog
- Publications 10862 available results
- Journals 420 available results
- Conferences 13 available results
- Publishing Houses 1 available results
- People 540 available results
- Projects 38 available results
- Laboratories 1 available results
- e-Learning Courses 269 available results
- Events 36 available results
- Offers 1 available results
- Open Research Data 2301 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: customer-side resources interconnection , single phase vapf , voltage active power filter , power electronics converter , energy cost reduction
-
High Efficiency Dual-Active-Bridge Converter with Triple-Phase-Shift Control for Battery Charger of Electric Vehicles
PublicationAn optimal modulation scheme with triple-phase-shift (TPS) control could increase the efficiency in the entire load range for a dual-active-bridge (DAB) converter under wide output voltage range conditions. Therefore, this study proposes a convergent approach to TPS mode selection, coupled with an optimal modulation scheme, ensuring the circuit’s efficiency over the entire range in the realm of a high-power and high-efficiency...
-
Voltage and frequency regulation of a standalone induction generator by reduced-rating power electronic compensators - comparative evaluation
PublicationIn this paper are considered two fundamental topologies of power electronic compensators for voltage and frequency control of a standalone self-excited induction generator (IG) system. These are voltage and current source inverter based shunt compensators with energy storage. The aim of this study is to assess main features of both topologies in dynamic and steady-state IG operation. The whole system is modelled with the aid of...
-
The Large Customer Reactive Power Control Possibilities
Publicationn this paper the authors wish to draw attention to the rationale for, and the possibility of, the use of local reactive power sources by the Transmission Node Master Controller (TNMC). Large Customers (LC) are one of the possible reactive power sources. The paper presents the issues related to the need for coordination between the control systems installed in the LC network, and coordination between control systems of the LC as...
-
Hydro Power Plant in the Process of Voltage Control in the Electric Power System and the System Restoration
PublicationThe article covers selected issues related to the share of hydroelectric power in the process of rebuilding the power system after black-out and voltage control during that process. Selected results of measurements made during the creation of the transmission chain for the need to start a block of a thermal power plant from a hydroelectric power plant were presented.
-
Compensation of Dead Time Effects for Shunt Active Power Filters
PublicationThe paper presents a comprehensive approach to the compensation of the grid current distortion for shunt active power filter systems. Four different sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the estimation of compensating currents and grid voltages, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublicationPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Magnetic and capacitive couplings influence on power and energy measurement in double circuit high voltage overhead transmission line
PublicationThe paper discusses influence of magnetic and capacitive couplings on power and energy measurement in case of double circuit high voltage overhead transmission line. There are presented and discussed various factors influencing the power flow among the line‟s circuits. Mathematical model based calculations results are compared to the real transmission line measurements.
-
Hybrid stepless distribution transformer with four-quadrant AC/DC/AC converter at low voltage side - simulation tests
PublicationThe article presents the work of the stepless hybrid distribution transformer (HT), as an alternative to the so far applied Automatic Voltage Regulator (AVR) solutions, used to control the voltage in the power system in terms of the fundamental harmonic. The HT is a combination of a conventional distribution transformer and an AC/DC/AC converter connected in series with the transformers secondary winding. In the work the basic...
-
Energy losses reduction in the medium voltage cable line – case study
PublicationThe paper presents an analysis of energy losses in a power cable system, which is composed of two 30 kV cable lines. This cable system is located at the seaside holiday area, so the load profile during a year is specific. Energy losses related to reactive power transmission, as well as to currents induced in the sheaths of the cables, are subject to analysis. Measurements were made in the system in order to prepare a computer model...
-
Predictive control system of the shunt active power filter
Publication -
New control system of the shunt active power filter
Publication -
The Impact of Micro-Sources on Voltage Distortions in a Power Grid
PublicationThe increase in the number of photovoltaic (PV) systems integrated with low voltage (LV) grids has led to a great need to analyse the impact of these systems on the quality of electricity and the reliability of its supply. This paper presents and compares the energy quality requirements imposed by various countries on photovoltaic plants. Then, based on real object tests and simulation in DIgSILENT PowerFactory, the impact has...
-
INCREASING POWER SUPPLY SAFETY IN THE ASPECT OF SUPPORTING THE RENEWABLE ENERGY SOURCES BY CONVENTIONAL AND VIRTUAL POWER STORES
PublicationThis paper presents characteristics and purposefulness of supporting the renewable energy sources (OZE) by means of energy stores. The main emphasis was placed on analysis of virtual energy stores available for implementation in Polish economy conditions. A role which management of Demand Side Response (DSR) may play in balancing Polish electric power system, is discussed. Implementation of such solutions together with conventional...
-
Numbers, Please: Power- and Voltage-Related Indices in Control of a Turbine-Generator Set
PublicationThis paper discusses the proper selection and interpretation of aggregated control performance indices values mirroring the quality of electrical energy generation by a turbine-generator set cooperating with a power system. Typically, a set of basic/classical and individual indices is used in energy engineering to ensure the mirroring feature and is related to voltage, frequency and active or reactive power deviations from their...
-
Methodology for implementing power plant efficiency standards for power generation: potential emission reduction
PublicationSome methods of generating power such as power generation through coal, natural gas, oil result in inevitable emissions of greenhouse gases. While power generation is necessary due to its increasing demand, it is important for power companies to generate their power in an efcient manner to reduce its efect on the environment. One of the most efective ways of tackling inefciency issues is through the implementation of efciency standard....
-
Low-Voltage Low-Power Filters with Independent ω0 and Q Tuning for Electronic Cochlea Applications
PublicationAn acoustic second-order low-pass filter is proposed for filter banks emulating the operation of a human cochlea. By using a special filter structure and an innovative quality (Q)-factor tuning technique, an independent change of the cutoff frequency (ω0) and the Q-factor with unchanged gain at low frequencies is achieved in this filter. The techniques applied result in a simple filter design with low Q-factor sensitivity to component...
-
Multi-transformer primary-side regulated flyback converter for supplying isolated IGBT and MOSFET drivers
PublicationThis paper presents primary-side voltage regulated multi-transformer quasi-resonant flyback converter (MTFC) for supplying isolated power switch drivers. The proposed topology offers distinct advantages over frequently used flyback converter possessing one high frequency transformer with isolated multiple outputs. Particularly, when a large number of separate dc supply units is required, then MTFC enables improved regular distribution...
-
Evaluation of VSC Impact on Power System Using Adequate P-Q Capability Curve
PublicationRenewable energy sources, which are becoming increasingly popular, often use a voltage source converter (VSC) for connection to the power system. Assessing the effects of connecting such a source to the power system is essential to ensure the proper operation of the power system and the connected source. For this purpose, it is necessary to know the range of active and reactive power generation by the converter. The authors indicate...
-
Power Hardware In-the-Loop validation of DC-DC power converter for offshore wind energy
Publication -
Four Level Diode-Clamped Back-To-Back Converter with Active DC Link Voltage Control
PublicationThis article presents the design and control of 4L-DC back-to-back converter. To solve the DC link voltage balancing problem in four-level converter a new three-level double chopper topology based on PO-PWM modulation was designed and successfully tested. Also, the paper describes two phase space vector pulse width modulation 2P-SVPWM based on the shape function of finite elements. The control structure with modified Dead-Beat...
-
Optimization of thermal backfill configurations for desired high-voltage power cables ampacity
PublicationThe ampacity of high-voltage power cables depends, among others, on their core cross-sectional area as well as thermal resistivity of the thermal backfill surrounding the cables. The cross-sectional area of the power cables’ core is selected according to the expected power to be transferred via the cable system. Usually, the higher the power transfer required, the higher the cross-sectional area of the core. However, the cost of...
-
Experimental test results of an automatic voltage regulator with independent phase voltage controllers
PublicationThe growing number of distributed renewable energy sources and dynamic constant-power loads (e.g. electric vehicle charging stations) pose new challenges for network operators. These changes result in alterations to network load profiles and load flows, leading to greater voltage volatility. One effective solution to these problems can be the use of automatic voltage regulators (AVRs), which stabilize and symmetrize voltage output,...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublicationThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
CM Voltage Compensators for Power Electronic Interfaces
PublicationThe experimental results presented in the paper have shown that the application of the PEIs might cause EMC related problems, especially in the case of the application of a group of connected converters. The most convenient way to reduce EMI currents and prevent aggregation of EMI currents introduced by a group of converters is through passive compensation of voltage interference sources inside of the single converters. In the...
-
Lagrangian model of an isolated dc-dc converter with a 3-phase medium frequency transformer accounting magnetic cross saturation
PublicationThis article presents a nonlinear equivalent circuit model of an isolated dc-dc converter with a 3-phase medium frequency transformer. The model takes into account the magnetic cross saturation of the 3-phase core-type magnetic circuit. The model is suitable in detailed electromagnetic transient simulations of power systems involving isolated dc-dc converters. The model is developed using the Lagrange energy method. It involves...
-
A low-voltage CMOS negative impedance converter for analogue filtering applications
PublicationLow-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....
-
Cross-border transmission line configuration influence on the electrical power and energy billing process
PublicationIn 2015 a connection between the Polish and Lithuanian power systems become fully operational. The connection consists of a 400 kV double circuit transmission line and a back-to-back HVDC substation located on the Lithuanian side. A magnetic couplings between the circuits of the transmission line cause that during power transmission a different values of active power losses are observed in both circuits. This situation may cause...
-
Design and evaluation of a base module of active power electronic transformer
PublicationThis paper presents an active power electronic transformer (APET) based on modular structure. The proposed three phase APET consists of at least three base modules (BM). The input/output stage of the BM is based on half-bridge sub modules. The isolation stage includes a medium frequency transformer and is realized as a dual half-bridge. The paper describes construction process and explains the control strategy. The theoretical...
-
A multi-pulse diode rectifier with a coupled three-phase reactor and additional small shunt active power filter
Publication -
Conjugated control of triple active bridge converter with common HFT
PublicationPaper presents synthetic analyses of single input, dual output DC/AC/DC converter with common high frequency transformer. Rise the problem of cross-coupling power flows between secondary terminals, under asymmetrical control operating condition. It also proposes a new approach to converter control, based on conjugated phase shift modulation and defines its limitations. Finally, the developed control technique was verified by simulation...
-
Cascaded Buck Hybrid Interlink Converter for Multiple-Input / Multiple-Output Operation
PublicationThe provision of isolated- and non-isolated DC output voltages by Power electronics power-conditioning devices in the recent ‘green-energy-revolution’ era is on course. In this paper, a structure for multi-input multi-output(MIMO) DC–DC buck converter is proposed to generate output voltages of varying levels with fewer component-count. The DC output voltage of each of the constituting buck converters can be used independently or...
-
Experimental tests results of the diode rectifier with series active power filter
Publication -
Energy Modeling of Single-Family Houses in the Conceptual Phase
PublicationThe aim of the article is to identify the potential impact of the latest commercial digital tools for building energy analysis on the everyday architectural practice in Poland in the context of typology and energy optimization of single –family houses. The reason for this survey is that “architect friendly” interfaces simulation results’ visualization and energy analysis tools are not given deserved attention in the architectural...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
The Issues of Reactive Power Compensation in High-voltage Transmission Lines
PublicationThis paper discusses the selection of compensation shunt reactors for a double-circuit 400 kV transmission line using the example of the newly built Elk Bis – Alytus transmission line. The analysis takes into account various conditions of the power system. The published results relate to voltage levels in steady states and during switching processes and short circuits.
-
The reduction of auxiliaries power demand: The challenge for electromobility in public transportation
PublicationAn important role in the consumption of electric energy in urban transport are non-traction needs (auxiliaries), the main part of which is heating and air condition (HVAC). Auxiliaries are responsible for almost half of total energy consumption (normal weather conditions) and in the winter (or hot summer) it reaches up to 70% in daily scale. The reduction of energy used for non-traction needs is currently the main challenge related...
-
Magnetic and capacitive couplings influence on power losses in double circuit high voltage overhead transmission line
PublicationPurpose – The paper aims to discuss problems of power and energy losses in a double-circuit overhead transmission line. It was observed from energymeters’ readings, that in such a line, active power losses can be measured as “negative”. The “negative” active power losses appear when the active power injected to the circuit is lower than the active power received at the circuit end. The purpose of this paper is to explain this phenomenon. Theoretical...
-
Structure and the space vector modulation for a medium-voltage power-electronic-transformer based on two seven-level cascade H-bridge inverters
PublicationThis study presents the structure and the space vector pulse-width modulation (SVPWM) for power electronic transformer (PET) based on two seven-level cascade H-bridge (CHB) inverters. The DC links of CHB inverters are coupled with nine dual-active bridge (DAB) converters with medium-frequency transformers. The DC-link voltages are equalised with two methods – through the control of DAB voltages...
-
Energy losses in hydrostatic drive:Drive investigation method compatible with diagram of power increase opposite to the direction of power flow
PublicationEnergy losses and efficiency of drive motor must be presented as functions of physical quantities independent of losses in the motor. Such quantities are speed and load required by the driven device, changing in the drive operating field. Speed and load decide of the useful power and, in differentiated way, of kinds and values of losses in the motor. But energy losses and efficiency of drive motors are evaluated as functions of...
-
Light-Powered Starter for Micro-Power Boost DC–DC Converter for CMOS Image Sensors
PublicationThe design of a starter for a low-voltage, micro-power boost DC–DC converter intended for powering CMOS image sensors is presented. A unique feature of the starter is extremely low current, below 1 nA, supplying its control circuit. Therefore, a high-voltage (1.3 V) configuration of series-connected photovoltaic diodes available in a standard CMOS process or a small external LED working in photovoltaic mode can be used as an auxiliary...
-
Optimizing the parameters of a small standalone hybrid power system
PublicationA hybrid power plant consists of renewable energy resources, an energy storage, a discharge load and an emergency power supply. Power plant parameters are tailored to meet the requirements of continuity of supply, cost minimization, return on investment period and system capacity utilization. The papaer presents the methodology for selecting power plant parameters with a larger number of decision criteria. The task is solved...
-
Open-Phase Fault Detection Method for Sensorless Five-Phase Induction Motor Drives with an Inverter Output Filter
PublicationThe paper presents the sensorless five-phase induction motor drive implementation with an inverter output filter with third harmonic injection. For the sensorless operation, the required observers are presented for the first and third harmonics with consideration of the inverter output filter. Moreover, the interaction of the observers and the control system is capable to handle a deactivation of one or two phases, which improves...
-
Four level inverter's DC bus voltage balancing with 3-terminal DAB converter
Publication—Multilevel inverters become more and more popular, especially in the medium or high voltage and high power applications. Unfortunately, some of inverter topologies require additional DC bus voltage balancing systems. This paper presents a novel approach to such systems, which is based on a multiple terminal DAB converter. Along with the voltage balancing function the proposed solution enables the connection of energy storage devices...
-
Laboratory Load Model Based on 150 kVA Power Frequency Converter and Simulink Real-Time – Concept, mplementation, Experiments
PublicationFirst section of the paper provides technical specification of laboratory load model basing on 150 kVA power frequency converter and Simulink Real-Time platform. Assumptions, as well as control algorithm structure is presented. Theoretical considerations based on criteria which load types may be simulated using discussed laboratory setup, are described. As described model contains transformer with thyristor-controlled tap changer,...
-
Nuclear power plant as a source of electrical energy and heat
PublicationIn this paper certain issues concerning usage of nuclear power plants as sources of not only electric power but also thermal energy will be discussed. For such a solution appeals most of all the need to limit harmful emissions of gases (including CO2) and ashes, which come from the process of burning fossil fuels, as well as the raising demand for network heat and chill. Additionally combined heat and power production brings measurable...
-
ANALYSIS OF THE FEATURES OF EFFECTIVE IMPLEMENTATION OF SOLAR POWER PLANTS IN LOCAL ENERGY SUPPLY SYSTEMS
PublicationПоказано, що відновлені джерела енергії (ВДЕ) у багатьох країнах дедалі більше домінують на ринку електроенергії, при цьому обсяги генерації електроенергії сонячними електростанціями (СЕС) останніми роками зростають рекордними темпами. Зазначено, що хоча частка ВДЕ продовжує зростати і фотоелектрична індустрія стрімко розвивається, однак галузь все ще стикається з багатьма проблемами, зокрема як продовжувати знижувати нормовану...
-
Modelling and analysis of medium frequency transformers for power converters
PublicationThe evolutions in power systems and electric vehicles, related to the economic opportunities and the environmental issues, bring the need of high power galvanically isolated DC-DC converter. The medium frequency transformer (MFT) is one of its key components, enabled by the increasing switching frequency of modern power semiconductors like silicon carbide transistors or diodes. The increased operating frequency offers small...
-
Interline power flow controller - properties and control strategy in dynamic states
PublicationHigh-power electronic converter topologies, in such forms as Unified Power Flow Controllers (UPFC), Static Compensators (STATCOM) and Interline Power Flow Controllers (IPFC), have been used to enhance and optimize the use of transmission facilities, under the concept of a flexible ac transmission system (FACTS). In Europe, the anticipated proliferation of distributed-generation (DG) in the near future, driven by governmental initiatives...
-
Activity coordination of capacitor banks and power transformer controllers in order to reduce power losses in the MV grid
PublicationOne of the main issues related to the optimization of the MV (middle voltage) network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility...
-
CAES – Energy storage providing stability for national power system
PublicationThis paper presents a short characteristics of the power system. It also describes various types of energy storage technologies. The suggested solution of accumulation and generation of electric power is based on the cooperation of gas turbine with Compressed Air Storage Energy systems – CAES. This analysis describes also various types of cooperation of CAES and renewable sources of energy, particularly wind power systems.