Search results for: HIGH VOLTAGE POWER CONVERTERS - Bridge of Knowledge

Search

Search results for: HIGH VOLTAGE POWER CONVERTERS

Filters

total: 1059
filtered: 845

clear all filters


Chosen catalog filters

  • Category

  • Year

  • Options

clear Chosen catalog filters disabled

Search results for: HIGH VOLTAGE POWER CONVERTERS

  • Problems of Connecting Wind Farms to the Power System with HV Cables

    Publication

    This paper presents problems caused by connecting wind farms to a power system with high voltage cables. The author highlights possible problems with reactive power compensation, depending on the arrangement of the shunt reactor connection and settings of control systems for reactive power and voltage of the wind farm. The paper also discusses issues of increasing active power losses caused by a shunt reactor installation.

    Full text available to download

  • Balancing energy consumption in limited power grid with active front-end and three phase dual active bridge system

    Publication

    - Year 2020

    Paper deals with simulation analysis of bidirectional power converters system for charging station of electric vehicle in condition of limited power source in city infrastructure. In case of incapability to provide additional power supply through the grid by virtue of historical, architectural and economic reasons it is possible to solve this issue by implementation of mobile battery-powered supply source. The proposed bidirectional...

    Full text available to download

  • Estimation of the Maximum Permissible PV Power to be Connected to the MV Grid

    Publication

    - Year 2023

    In recent decades, a significant increase in the share of renewable energy sources in power grids at various voltage levels has been observed. A number of articles have been published highlighting emerging problems in low-voltage grids with a large share of prosumers and in medium- and high-voltage grids to which photovoltaic (PV) plants are connected. The article analyzes the medium-voltage grid in terms of the possibility of...

    Full text to download in external service

  • Research of Emergency Modes of Wind Power Plants Using Computer Simulation

    Publication
    • M. Z. Qawaqzeh
    • O. Miroshnyk
    • T. Shchur
    • R. Kasner
    • A. Idzikowski
    • W. Kruszelnicka
    • A. Tomporowski
    • P. Bałdowska-Witos
    • J. Flizikowski
    • M. Zawada
    • K. Doerffer

    - ENERGIES - Year 2021

    The aim of this study is to investigate changes in the wind power plant energy production parameters under the conditions of sudden wind changes and voltage drop. To achieve these goals, a simulation of operation of wind power plants was performed. Twelve wind turbines with variable rotational speed equipped with a Fuhrländer FL 2500/104 asynchronous double-fed induction generator (DFIG) were used, each with an installed capacity...

    Full text available to download

  • Voltage Transients Transfer over Medium Voltage Instrument Transformers

    Publication

    - Year 2011

    This paper presents voltage harmonic transfer accuracy problems through voltage transformers which are used in power quality monitoring systems in medium and high voltage grids. A simplified lumped parameters circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number voltage transformers typically used in medium voltage grid has been tested in the conducted disturbances...

  • High frequency test measurements on physical model of power transformer with use of FRAX analyzer Streszczenie. W niniejszym artykule przedstawiono pomiary testowe SFRA wykonane na modelu fizycznym transformatora elektroenergetycznego

    Publication

    Full text to download in external service

  • Voltage Harmonics Transfer through Medium Voltage Instrument Transformers

    Publication

    Voltage transformers are widely used in power quality monitoring systems in medium and high voltage grids. This paper presents accuracy problems related to voltage harmonics transfer through instrument transformers. A simplified lumped-parameters wideband circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number of voltage transformers have been tested in the frequency...

    Full text available to download

  • Four level inverter's DC bus voltage balancing with 3-terminal DAB converter

    Publication

    - Year 2016

    —Multilevel inverters become more and more popular, especially in the medium or high voltage and high power applications. Unfortunately, some of inverter topologies require additional DC bus voltage balancing systems. This paper presents a novel approach to such systems, which is based on a multiple terminal DAB converter. Along with the voltage balancing function the proposed solution enables the connection of energy storage devices...

    Full text to download in external service

  • On the use of a charge balancing method for low energy measurements

    The paper presents the method for the estimation of the energy consumption of the low-power microcontroller-based devices. Due to high dynamics of the changes of the supply current of the tested devices during the operational cycle, the consumed energy estimation is not easy. In order to avoid disadvantages of known methods, the charge balancing method was employed similarly like in some types of A/D converters.

    Full text available to download

  • Risk of power cables insulation failure due to the thermal effect of solar radiation

    Publication

    Low-voltage, as well as high-voltage power cable lines, are usually buried in the ground. The ampacity of the power cables in the ground mainly depends on the thermal resistivity of the soil, which may vary in a wide range. A common practice in power cable systems performance is to supply them from a pole of an overhead line. If so, a section of the line is located in free air and can be directly exposed to solar radiation. In...

    Full text available to download

  • Metrological analysis of an computerized system of protection against electric shock in circuits with variable speed drives

    Drive systems, that can be operated at variable speed, are equipped with power electronics converters. This causes distortion of the earth current, and consequently the need to take into account the use of proper protective devices in relation to earth current harmonics. This paper presents a system for protection against electric shock in circuits with power electronics converters and metrological analysis indicating the requirements...

    Full text available to download

  • Voltage Harmonic Distortion Measurement Issue in Smart-Grid Distribution System

    Publication

    - Year 2012

    This paper presents the investigation results ofvoltage harmonic transfer accuracy problems through voltagetransformers which are widely used in power quality monitoringsystems in medium and high voltage grids. A simplified lumpedparameters circuit model of the voltage transformer is presentedand verified by simulation and experimental investigations. Anumber voltage transformers typically used in medium voltagegrid has been tested...

    Full text to download in external service

  • Starter for Voltage Boost Converter to Harvest Thermoelectric Energy for Body-Worn Sensors

    Publication

    This paper examines the suitability of selected configurations of ultra-low voltage (ULV) oscilla-tors as starters for a voltage boost converter to harvest energy from a thermoelectric generator (TEG). Important properties of particularly promising configurations, suitable for on-chip imple-mentation are compared. On this basis, an improved oscillator with a low startup voltage and a high output voltage swing is proposed. The applicability...

    Full text available to download

  • VSC converters control for offshore wind farms HVDC grid connection

    Publication

    - Year 2013

    The paper proposes a voltage sourced converter (VSC) new control method. A well-known in the electric power systems correlation between voltage angle and active power and correlation between voltage and reactive power is used instead of feedforward control. This allows for a fast and almost independent control of active and reactive power flow.

    Full text to download in external service

  • Selection of energy storage units by genetic algorithm for mitigating voltage deviations

    Publication

    In recent years, energy storage units have become very popular. They are applied both for economic and technical purposes. Unfortunately, the cost of such devices is still high and selecting their proper location and rated power have to be performed precisely. In this paper, a Genetic-Algorithm-based optimization method for selecting the best configuration of energy storage units in the power network is proposed. The presented...

    Full text to download in external service

  • Frequency Diagnostics of Transformer Insulating Parameters

    Publication

    - Year 2020

    In the article is presented experimental analysis and diagnostics of insulating system oil-paper for power transformers, mainly by progressive frequency method – dielectric spectroscopy. In the 1-st part of the article is described base theory about measurement and diagnostics insulating part (oil and paper) of power transformers. In the 2-nd part of article is described measuring method of insulating frequency diagnostics - frequency...

    Full text to download in external service

  • Failure analysis of a high-speed induction machine driven by a SiC-inverter and operating on a common shaft with a high-speed generator

    Publication

    - Eksploatacja i Niezawodność - Maintenance and Reliability - Year 2022

    Due to ongoing research work, a prototype test rig for testing high-speed motors/generators has been developed. Its design is quite unique as the two high- speed machines share a single shaft with no support bearings between them. A very high maximum operating speed, up to 80,000 rpm, was required. Because of the need to minimise vibration during operation at very high rotational speeds, rolling bearings were used. To eliminate...

    Full text available to download

  • A Single-Carrier-Based Pulse-Width Modulation Template for Cascaded H-Bridge Multilevel Inverters

    Publication

    - IEEE Access - Year 2021

    Multiplicity of the triangular carrier signals is a criterion for the extension of sinusoidal pulsewidth modulation, SPWM, to a number of output voltage levels per phase-leg in cascaded H-bridge (CHB) multilevel inverter (MLI). Considering medium and high voltage applications where appreciable number of output voltage levels from CHB MLI is needed, commensurate high number of carrier signals in either classical level- or phase-shifted...

    Full text available to download

  • High Efficiency Dual-Active-Bridge Converter with Triple-Phase-Shift Control for Battery Charger of Electric Vehicles

    Publication
    • S. Kuo
    • H. Chiu
    • C. Chiang
    • T. Huang
    • Y. Chang
    • S. Bachman
    • S. Piasecki
    • M. Jasiński
    • M. Turzyński

    - ENERGIES - Year 2024

    An optimal modulation scheme with triple-phase-shift (TPS) control could increase the efficiency in the entire load range for a dual-active-bridge (DAB) converter under wide output voltage range conditions. Therefore, this study proposes a convergent approach to TPS mode selection, coupled with an optimal modulation scheme, ensuring the circuit’s efficiency over the entire range in the realm of a high-power and high-efficiency...

    Full text available to download

  • The effect of current delay angle on tripping of residual current devices

    Publication

    - Year 2017

    Power electronics converters applied in domestic or similar installations may utilize current delay (phase) angle control to change the level of transferred power. Due to application of such types of converters, earth fault current in the installation may be strongly distorted. The current distortion level depends on a value of current delay angle. This delay angle also influences the tripping threshold of residual current devices....

    Full text to download in external service

  • Voltage variations and their reduction in a rural low-voltage network with PV sources of energy

    Publication

    - Electronics - Year 2021

    Renewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...

    Full text available to download

  • Multi-pulse VSC arrangements with coupled reactors

    Publication

    - Year 2016

    This paper presents a novel approach to the multipulse VSC (Voltage Source Converter) arrangements based on several conventional inverter modules connected in parallel by using coupled reactors. This solution reduces the THD of the output voltage, despite the low switching frequency of transistors. The advantage of the proposed solution is also a relatively small rated power of the reactors. Proposed new arrangements for different...

    Full text to download in external service

  • Przekształtniki tranzystorowe działające w trybie prądu trójkątnego

    Publication

    Przekształtniki oparte na węgliku krzemu mogą być analizowane jako źródła napięcia lub prądu niezależnie od topologii przy odpowiednich parametrach filtru wyjściowego. Szczególnie interesujące są falowniki napięcia działające w trybie prądu trójkątnego. W referacie przedstawiono sterowanie trójfazowym falownikiem napięcia posiadającym właściwości źródła prądu. Pokazano, jak dobrać parametry filtru wyjściowego falownika. Oceniono...

    Full text available to download

  • Harmonics produced by traction substations – computer modelling and experimental verification

    Voltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion include traction rectifiers. This paper presents results of the computer investigation of...

    Full text available to download

  • Sensorless predictive control of three-phase parallel active filter

    Publication

    The paper presents the control system of parallel active power filter (APF) with predictive reference current calculation and model based predictive current control. The novel estimator and predictor of grid emf is proposed for AC voltage sensorless operation of APF, regardless of distortion of this voltage. Proposed control system provides control of APF current with high precision and dynamics limited only by filter circuit parameters....

    Full text to download in external service

  • Design of Intelligent Low-Voltage Load Switch for Remote Control System in Smart Grid

    Publication
    • D. Xiong
    • X. Chen
    • R. Martinek
    • H. Wen
    • D. Luo
    • J. Smulko

    - Iranian Journal of Science and Technology-Transactions of Electrical Engineering - Year 2021

    Current low-voltage load switches do not support remote disconnect/connect and real-time monitoring of a disconnect/connect state. Addressing to these issues, this paper presents a low-voltage load switch for a smart remote control system, which uses a one-chip microcontroller board and a DC step motor drive mechanism and provides the feedback on the switch status also. Arrears disconnect and full-pay connect control is implemented...

    Full text available to download

  • An Ultra-Low-Energy Analog Comparator for A/D Converters in CMOS Image Sensors

    This paper proposes a new solution of an ultra-low-energy analog comparator, dedicated to slope analog-to-digital converters (ADC), particularly suited for CMOS image sensors (CISs) featuring a large number of ADCs. For massively parallel imaging arrays, this number may be as high as tens-hundreds of thousands ADCs. As each ADC includes an analog comparator, the number of these comparators in CIS is always high. Detailed analysis...

    Full text available to download

  • Induced sheath voltages in 110 kV power cables – case study

    This paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse...

    Full text available to download

  • Higher harmonics produced by traction substations – computer modelling and experimental verification

    Voltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers, although the rms value of load current does not exceed their current-carrying capacity. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion...

    Full text to download in external service

  • Resonant Conditions in a Node with an SVC Compensator

    Publication

    - Acta Energetica - Year 2016

    The primary purpose of installing static shunt compensators in power grids is to improve the voltage conditions. Additional reactive power sources increase the system’s voltage stability and enable faster system recovery after a voltage failure. This paper presents the impact of an SVC device’s structure and settings on impedance change in the supply system, and hence on the frequencies at which resonance phenomena can develop.

    Full text available to download

  • Active Power Quality Controllers

    Publication

    - Year 2008

    Dynamic Static Synchronous Compensator is the most important controller for distribution networks and probably in SEEN. It has been widely used since the 1990s to regulate system voltage precisely, improve voltage profile, reduce voltage harmonics, reduce transient voltage disturbances and load compensation. Rather than using conventional capacitors and inductors combined with fast switches, the D-STATCOM uses a power-electronics...

    Full text to download in external service

  • Novel single-stage buck-boost inverter with unfolding circuit

    Publication

    - Year 2017

    A novel solution of a single-stage buck-boost inverter with unfolding circuit at the output stage is presented. The inverter has a wide range of input voltage regulation, minimum passive components and a very flexible control structure. It can be applied for renewable energy systems where high power density is required. Our simulation results confirmed all theoretical statements

    Full text to download in external service

  • Incomplete Cross-Bonding in the MV Line. Experience from the Operation of MV Single Cable Lines

    Publication

    - ENERGIES - Year 2020

    Cable lines are one of the basic components of power systems. Medium and high voltage cables mainly comprise a metallic sheath, which is concentric to the main core conductor. There are several operating schemes of such cable lines, which differ in the place of earthing of sheaths and the possible use of the sheaths and/or conductors crossing. The sheaths cross-bonding is typically done in two places of one cable line section,...

    Full text available to download

  • Light-Powered Starter for Micro-Power Boost DC–DC Converter for CMOS Image Sensors

    The design of a starter for a low-voltage, micro-power boost DC–DC converter intended for powering CMOS image sensors is presented. A unique feature of the starter is extremely low current, below 1 nA, supplying its control circuit. Therefore, a high-voltage (1.3 V) configuration of series-connected photovoltaic diodes available in a standard CMOS process or a small external LED working in photovoltaic mode can be used as an auxiliary...

    Full text available to download

  • Static Series and Shunt-series PE Voltage-quality Controllers

    Publication

    - Year 2007

    As presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...

    Full text to download in external service

  • Performance Evaluation of a 650V E-HEMT GaN Power Switch

    Publication

    - Year 2015

    GaN power switches have better characteristics compared to the state-of-the-art Si power transistors. These devices offer high operating temperature and current densities, fast switching and low on-resistance. However, currently only a few producers offer technology of high voltage GaN transistors. Immaturity of this technology is the reason why experimental evaluation of GaN parameters must be performed to properly exploit their...

  • Static Shunt PE Voltage-Quality Controllers

    Publication

    - Year 2007

    This chapter focuses on power electronics (PE)-based solutions used in distribution networks for reduction of supply-voltage-quality deterioration, from long interruptions to the harmonics. Various PE devices and their combinations are addressed for particular or a range of voltage disturbances. A particular solution is applied taking into account demands for voltage quality and network configuration. In general, there are three...

    Full text to download in external service

  • Overheating of underground power cable line due to its partial exposition to solar radiation

    Publication

    - Year 2019

    Current-carrying capacity of underground power cable lines depends, among others, on thermal resistivity of the soil and cables layout: trefoil formation, flat formation with or without spacing. If conditions for heat transfer in the ground are favorable, the current-carrying capacity is relatively high. Therefore, it generates risk of the power cables overheating, if part of the cable line is located vertically in the air, to...

    Full text to download in external service

  • Quality Evaluation of Voice Transmission Using BPL Communication System in MV Mine Cable Network

    Publication

    - Elektronika Ir Elektrotechnika - Year 2019

    This article presents results of a quality evaluation study, considering voice transmission in a 6 kV medium voltage cable network using the BPL (Broadband over Power Line) communication system. The tests are carried out under real mining conditions for the selected power cable without voltage, earthed at both sides. Such a method of monitoring work conditions is of great importance, especially during a disaster. Power cables are...

    Full text available to download

  • SiC-based T-type modules for multi-pulse inverter with coupled inductors

    Publication

    - Year 2017

    The paper presents SiC-based three-level T-type modules designed for a high-performance 30kVA DC/AC inverter operating at high frequency 85 kHz with low THD of the output voltage. This inverter system consists of two integrated parts. The first part is active and contains three parallelconnected three-phase T-type modules built with fast-switching SiC power transistors. The second, passive part of the system is a set of inductors...

    Full text to download in external service

  • Neutral earthing reactor protection

    The IEEE and CIGRE recommend protection systems for high voltage shunt reactors. Unfortunately the recommendations do not include guidelines for the protection of neutral earthing reactors, which are often connected to shunt reactors to increase the effectiveness of single pole auto-reclosing. The paper discusses earthing reactor protection issues with particular emphasis on the detection of internal faults. An analysis carried...

    Full text to download in external service

  • Control strategies and comparison of the Dynamic Voltage Restorer

    Publication

    - Year 2008

    This paper focuses on a selection problems of mitigation of the voltage disturbance by of the Dynamic Voltage Restorers (DVR’s). In short form presented and discussed are the basis of different control strategies of the DVR. The main emphasis is placed on application of modern power electronic devices. Authors of this paper in particular occupy oneself with analysis of the power rating of the typically DVR topologies. These problems...

    Full text to download in external service

  • Design of synchronous generator two inputs regulator based on hinf control theory.

    Publication

    - Year 2004

    The power system is highly nonlinear system, its dynamics depends on system network configuration, system loading… etc. To overcome the above mentioned difficulties and fulfill the performance requirements the different control methods are considered and tested for design of synchronous generator control system. Application of the H optimization method to synchronous generator regulator based on measurement of generator voltage...

  • Effect of solar radiation on current-carrying capacity of PVC-insulated power cables – the numerical point of view

    Publication

    Power cables are usually buried in the soil, which results in their relatively high current-carrying capacity. However, there are cases in which the starting/final section of a cable line runs along a pole of an overhead power line. Power cables can be directly exposed to solar radiation then, and this negatively influences their current-carrying capacity as well as estimated life of the cables’ insulation. An analysis of thermal...

    Full text available to download

  • Installation of Compensators in the Power System Transmission Grid

    Publication

    - Acta Energetica - Year 2019

    The article discusses issues of reactive power compensation in transmission grids, with particular focus on the selection of compensator locations and basic parameters. Attention was focused on modern power electronics systems that ensure full automatic compensator adjustment to voltage or power criteria.

    Full text available to download

  • MPPT and GMPPT Implementation for Buck-Boost Mode Control of quasi-Z-Source Inverter

    Publication
    • O. Husev
    • D. Vinnikov
    • C. Roncero-Clemente
    • F. Blaabjerg
    • R. Strzelecki

    - IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS - Year 2022

    The focus is on the maximum power point tracking implementation for the buck-boost voltage mode control of a single-phase multilevel inverter based on a three-level neutral point clamped quasi-Z-source topology. To utilize shoot-through states only when boost function is needed and avoid it in the buck mode, two different control approaches are required. This work proposes merged control system which provides switching between...

    Full text available to download

  • Induction Generator with Direct Control and a Limited Number of Measurements on the Side of the Converter Connected to the Power Grid

    Publication

    - ENERGIES - Year 2022

    The article presents an induction generator connected to the power grid using the AC/DC/AC converter and LCL coupling filter. Three-level inverters were used in the converter, both from the generator side and the power grid side. The algorithm realizing Pulse Width Modulation (PWM) in inverters has been simplified to the maximum. Control of the induction generator was based on the Direct Field-Oriented Control (DFOC) method. At...

    Full text available to download

  • The measurement of input power of power supply in network disturbed by low frequency distortions

    In the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elements of studied device responsible for input power increase are pointed

    Full text available to download

  • Activity coordination of capacitor banks and power transformer controllers in order to reduce power losses in the MV grid

    Publication

    One of the main issues related to the optimization of the MV (middle voltage) network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility...

  • EMI attenuation in a DC-DC buck converter using GaN HEMT

    A dc-dc buck converter using gallium nitride (GaN) high electron mobility transistors (HEMT) is experimentally investigated at the discontinuous current mode (DCM) and at the triangular current mode (TCM) operation. The paper objective is to specify the power conversion efficiency and attenuation of common mode (CM) and differential mode (DM) noise voltage, measured at the line impedance stabilization network (LISN) for compared...

    Full text available to download