Filters
total: 51
Search results for: zvs/zvs inverter operation
-
Quasi-resonant DC-link voltage inverter with enhanced zero-voltage switching control
PublicationA new topology modification of the parallel quasi-resonant circuit for a dc-link voltage inverter enables regulation of the zero voltage dc-link subperiods and the dc-link voltage gradient settings. The proposed circuit is based on four MOSFET switches with free-wheeling diodes for controlled quasi-resonant recharging between L-C tank in order to assure inverter zero voltage switching (ZVS) conditions. Design optimization of the...
-
Comparative analysis of three‐phase dual active bridge converter with different transformer topology and modern universal control for DC microgrids
PublicationThe presented work discusses issues related to the use of modern multiphase topologies of Dual Active Bridge (DAB)-type converters. Converters of this type are widely used in most DC microgrid applications. The introduction emphasizes a comparative analysis between single-phase and multi-phase DAB topologies within high-power DC microgrids, delving into their respective advantages, drawbacks, design procedures, and considerations...
-
Wysokoczęstotliwościowy falownik napięcia - badania symulacyjne
PublicationWiększość ruchomych odbiorników energii elektrycznej jest połączona ze źródłem energii poprzez: giętkie przewody, komutatory, pierścienie ślizgowe lub pantografy. Taki sposób zasilania w energię elektryczną jest powszech-nie akceptowalny w łagodnym środowisku pracy, ale może być ograniczony w środowisku zagrożonym pod względem wybuchu lub wilgotnym. W wielu przypadkach zastosowań trakcyjnych warunki środowiskowe nie pozwalają na...
-
CCM and DCM operation analysis of cascaded quasi-Z-source inverter
Publication -
Five-phase induction motor drive with sine-wave filter
PublicationThe paper presents closed loop ac drive with 5 phase induction motor operating with voltage source inverter and sine wave filter. The motor supply voltages and currents have sinusoidal shape. For well known adjustable electric drives the field oriented control method with flux and speed co ntrol can be applied. In the presence of output filter both control and estimation algorithms should be modified due to sine wave filter installation....
-
A Simplified SPWM Scheme for a Compact 3-Level Dual-Output Inverter
PublicationSinusoidal Pulse-width modulation, SPWM, is inverter-leg-based, logical-operation-based, and lesscomputational-intensive. In this brief, these simplifying features of SPWM are extended to the control of the 10-switch, 3-level inverter. The control strategy is based on the single triangular carrier SPWM perspective. Procedures and details of the sharing of four-common power switches by the 3 inverter legs are given. Classically,...
-
Integrated Three-Level Dual-Phase Inverter
PublicationIn view of reducing the number of inverter legs that provide dual-phase, three-level output voltages (as may be needed in an uninterruptible power supply), and that also provide a wide range of output frequencies (as needed in an advanced motor drive system with wide speed ranges), a three-level, dual-phase inverter topology is presented in this paper. Its three-level attribute was based on the F-type inverter topological concept,...
-
A Five-Leg Three-Level Dual-Output Inverter
PublicationClassical 3-level dual-output inverter, 3-L DOI, involves two similar 3-level inverters that provides a pair of 3-phase output voltages with same or different frequencies from common input voltage source. Flexibility of either operation of the constituting inverters is evident in this DOI; but total duplication of power switches is a major drawback. State of the art coupled 3-L DOIs reduce this drawback by providing series-shared...
-
Open-Phase Fault Detection Method for Sensorless Five-Phase Induction Motor Drives with an Inverter Output Filter
PublicationThe paper presents the sensorless five-phase induction motor drive implementation with an inverter output filter with third harmonic injection. For the sensorless operation, the required observers are presented for the first and third harmonics with consideration of the inverter output filter. Moreover, the interaction of the observers and the control system is capable to handle a deactivation of one or two phases, which improves...
-
Novel Family of Single-Phase Modified Impedance-Source Buck-Boost Multilevel Inverters With Reduced Switch Count
Publicationhis paper describes novel single-phase solutions with increased inverter voltage levels derived by means of a nonstandard inverter configuration and impedance source networks. Operation principles based on special modulation techniques are presented. Detailed component design guidelines along with simulation and experimental verification are also provided. Possible application fields are discussed, as well as advantages and disadvantages....
-
Multilevel inverter neutral-point voltage sensor diagnostic based on the Extended Kalman Filter
PublicationA new algorithm for neutral point voltage imbalance estimation in DC link of the three-level (3L) neutral point clamped (NPC) voltage source inverter (VSI) is proposed. Application of the proposed algorithm does not require any additional sensors. The unbalanced voltage calculation is based on the information derived from the inverter output measured currents and from the knowledge of the load model parameters. In order to estimate...
-
Pulse-Width Modulation Template for Five-Level Switch-Clamped H-Bridge-Based Cascaded Multilevel Inverter
PublicationThis article presents a carrier-based pulse-width modulation (PWM) template for a 5-level, H bridge-based cascaded multilevel inverter (MLI). The developed control concept generates adequate modulation template for this inverter topology wherein a sinusoidal modulating waveform is modified to fit in a single triangular carrier signal range. With this modulation approach, classical multiplicity and synchronization of the triangular...
-
Sensorless five-phase induction motor drive with third harmonic injection and inverter output filter
PublicationThe paper presents a sensorless control approach for a five-phase induction motor drive with third harmonic injection and inverter output filter. In the case of the third harmonic injection being utilised in the control, the physical machine has to be divided into two virtual machines that are controlled separately and independently. The control system structure is presented in conjunction with speed and rotor flux observers that...
-
Analysis of electromagnetic disturbances in DC network of grid connected building-integrated photovoltaic system
PublicationThis paper focuses on conducted electromagnetic interference (EMI) emissions and propagation in the DC network of grid connected building integrated photovoltaic (PV) system. The investigated PV system, consists of ten solar panels, cabling and the grid-connected one phase inverter. The EMI simulation model of the real PV system has been developed with the aid of impedance analyzer measurements of solar panels and the DC network...
-
Quasi-discrete modelling of PMSM phase currents in drives with low switching-to-fundamental frequency ratio
PublicationThis study proposes a new quasi-discrete approach to modelling the permanent magnet synchronous motor (PMSM). The quasi-discrete modelling reflects the impact of continuous rotor movement, which takes place during a control cycle, on the shape of motor current waveforms. This provides much improvement in current modelling accuracy under inverter low switching-to-fundamental frequency operation. The proposed approach may be used...
-
Sensorless Fault Detection of Induction Motor with Inverter Output Filter
PublicationThe paper presents the problem of monitoring and fault detection of a sensorless voltage inverter fed squirrel cage induction motor with LC filter. The detection is based on load torque estimation of the investigated torque transmission system. The load torque is calculated besides the computation of other variables that are mandatory for sensorless drive operation such as rotor flux and speed. The implemented LC filter smooths...
-
Synchronized six-step voltage generation in high-speed PMSM drive
PublicationSynchronized voltage generation has already been considered in the context of pulse width modulation (PWM). References prove that synchronized PWM substantially decreases subharmonics in inverter output voltage when operating with low switching-to-fundamental frequency ratio. This paper identifies problems of unsynchronized voltage generation in electric drives under six-step inverter operation. Guidelines for the synchronization...
-
Optimized Space Vector Modulation strategy for five phase voltage source inverter with third harmonic injection
PublicationThis paper presents a simple and an effective SVM algorithm for five-phase Voltage-Source Inverters with the possibility to control independently the voltage vectors for fundamental and auxiliary orthogonal subspaces. The essential benefit is that output voltage is generated using only four active voltage vectors with limited numbers of switching. In the proposed solution, four active vectors are arbitrary chosen, independent of...
-
Kompleksowa analiza symulacyjna układu napędowego zespołu trakcyjnego
PublicationThe paper describes an approach to comprehensive analysis of traction electric drive. The drivetrain of ED-74 electric unit equipped with four inverter-fed induction motors was modeled in Matlab/Simulink. The model consists of functional blocks as: motors, inverters, drive controllers, filters. Structure and operation of the model was described. Chosen simulation results were presented and discussed. Two methods of modeling the...
-
Simulation model of IPMSM drive with rotor position estimator
PublicationThe paper presents a simulation model of electric drive consisting of: IPMSM motor, inverter and digital controller. The model was designed in Mathlab/Simulink. By modelling of the controller its discrete operation was taken into account in order to simulate precisely a specific sensorless control algorithm. A method for estimation of angular rotor position was proposed. Its mathematical algorithm was explained and errors were...
-
Multipulse inverter structures with low voltage distortion
PublicationA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse three-level...
-
SiC-based T-type modules for multi-pulse inverter with coupled inductors
PublicationThe paper presents SiC-based three-level T-type modules designed for a high-performance 30kVA DC/AC inverter operating at high frequency 85 kHz with low THD of the output voltage. This inverter system consists of two integrated parts. The first part is active and contains three parallelconnected three-phase T-type modules built with fast-switching SiC power transistors. The second, passive part of the system is a set of inductors...
-
Modeling the impact of rotor movement on non-linearity of motor currents waveforms in high-speed PMSM drives
PublicationMotor current measurement techniques as well as predictive control algorithms for electric drives rely on an assumption of linear motor currents changes resulting from constant inverter output voltages. Recent research has reported that this assumption does not hold in motors with short electrical time constant, and in drives whose rotor position advances substantially during a control period. This paper proposes a simulation model...
-
Modular multipulse voltage source inverters with integrating coupled reactors
PublicationA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse and twenty-four-pulse...
-
Space vector modulation in multilevel inverters of the servo drives of the trajectory measurements telescopes
PublicationUsing the MatLab/Simulink mathematical model of a three-phase three-level voltage inverter, the influence of the space-vector modulation (SVM) algorithm on the pulsations of the current (torque) of an AC motor in the range of low rotation speeds is considered. It is shown that the SVM of the second kind does not provide a pulsations level comparable to the pulsations of a sinusoidal pulse-width modulation (SPWM), both in the static...
-
Common-Mode Voltage and Bearing Currents in PWM Inverters: Causes, Effects and Prevention
PublicationIn modern induction motor drives an increase of transistors' switching frequency and a decrease of switching times are the sources of some serious problems. The high dv/dt and the common mode voltage generated by the inverter PWM control results in the appearances of bearing currents, shaft voltages, motor terminal overvoltages, the decrease of motor efficiency, and electromagnetic interference. The aspects of common mode (CM)...
-
The adaptive backstepping control of PMSM supplied by current source inverter for the field weakening region
PublicationThe sensorless control system of permanent magnet synchronous motor PMSM supplied by current source inverter for field weakening operation is presented in this paper. The adaptive backstepping control system and the backstepping speed observer are presented. The control system is based on multi-scalar variables. The control variables are: dc-link voltage and the output current vector pulsation. The control system was named voltage...
-
Modeling of a Quasi-Resonant DC Link Inverter Dedicated to Common-Mode Voltage and Ground Current Reduction
PublicationIn this paper, the modeling methodology of the AC drive system with a Parallel Quasi-Resonant DC Link Inverter (PQRDCLI) is described. A presented modeling approach is an attractive tool used for the effective evaluation of a common-mode (CM) voltage and grounds current reduction methods. Designed models of inverter, induction machine (IM), and cable are simple, thus the methods for parameter extraction are not complicated. Verification...
-
Electric shock hazard in circuits with variable-speed drives
PublicationThe conventional approach to electrical safety under fault condition in typical power systems considers earth fault currents of sinusoidal waveform and frequency of 50/60 Hz. However, in circuits with variable-speed drives, there is earth fault current flow with harmonics, and these harmonics influence the threshold of ventricular fibrillation. The paper presents earth fault current waveforms in circuits with variable-speed drives...
-
Nonlinear Control of a Doubly Fed Generator Supplied by a Current Source Inverter
PublicationNowadays, wind turbines based on a doubly fed induction generator (DFIG) are a commonly used solution in the wind industry. The standard converter topology used in these systems is the voltage source inverter (VSI). The use of reverse-blocking insulated gate bipolar transistor (RB-IGBT) in the current source inverter topology (CSI), which is an alternative topology, opens new possibilities of control methods. This paper presents...
-
Closed-Loop Control System Design for Wireless Charging of Low-Voltage EV Batteries with Time-Delay Constraints
PublicationThis paper presents an inductive power transfer system on the basis of a double single- phase three-level T-type inverter and two split transmitting coils for constant current and constant voltage wireless charging of low-voltage light electric vehicle batteries with closed-loop control, considering time-delay communication constraints. An optimal control structure and a modified control strategy were chosen and implemented to...
-
Sensorless Multiscalar Control of Five-Phase Induction Machine with Inverter Output Filter
PublicationThe paper presents a complete solution for speed sensorless control system for five-phase induction motor with voltage inverter, LC filter and nonlinear control of combined fundamental and third harmonic flux distribution. The control principle, also known as multiscalar control, nonlinear control or natural variables control, is based on a use of properly selected scalar variables in control feedback to linearize controlled system....
-
Voltage and frequency regulation of a standalone induction generator by reduced-rating power electronic compensators - comparative evaluation
PublicationIn this paper are considered two fundamental topologies of power electronic compensators for voltage and frequency control of a standalone self-excited induction generator (IG) system. These are voltage and current source inverter based shunt compensators with energy storage. The aim of this study is to assess main features of both topologies in dynamic and steady-state IG operation. The whole system is modelled with the aid of...
-
Dead time effects compensation strategy by third harmonic injection for a five-phase inverter
PublicationThis paper proposes a method for compensation of dead-time effects for a fivephase inverter. In the proposed method an additional control subsystem was added to the field-oriented control (FOC) scheme in the coordinate system mapped to the third harmonic. The additional control loop operates in the fixed, orthogonal reference frame ( α - β coordinates) without the need for additional Park transformations. The purpose of this method...
-
Speed Sensorless AC Drive with Inverter LC Filter and Fault Detection Using Load Torque Signal
PublicationThe industrial development in recent years has seen a major increase in the use of induction motors, whereby the cost has to be as low as possible and the lifetime as long as possible. To follow up this desire, investigations in this area have become very intense. For that reason, this paper presents a solution for driving an induction motor and simultaneous fault detection with no need for additional sensors. In order to achieve...
-
Dynamic characteristics of the proton exchange membrane fuel cell module
PublicationThe paper describes a fuel cell based system and its performance. The system is based on two fuel cell units, DC/DC converter, DC/AC inverter, microprocessor control unit, load unit, bottled hydrogen supply system and a set of measurement instruments. In the study presented in the paper a dynamic response of the proton exchange membrane (PEM) fuel cell system to unit step change load as well as to periodical load changing cycles...
-
Sensorless IPMSM drive with rotor position estimator based on analysis of phase current derivatives
PublicationThis paper describes a sensorless Interior Permanent Magnet Synchronous Motor (IPMSM) drive designed for traction applications. Wide-speed sensorless operation is provided with the use of three methods of rotor position estimation designed for: a standstill, low- and high-speed range. The paper focuses on the high-speed estimation algorithm. The estimator uses the derivatives of motor phase currentsresulting from PWM modulation...
-
Accurate modeling of quasi-resonant inverter fed IM drive
PublicationIn this paper wide-band modeling methodology of a parallel quasi-resonant dc link inverter (PQRDCLI) fed induction machine (IM) is presented. The modeling objective is early-design stage prediction of conductive electromagnetic interference (EMI) emissions of the considered converter fed IM drive system. Operation principles of the selected topology of PQRDCLI feeding IM drive are given. Modeling of the converter drive system is...
-
Wpływ uwarunkowań rzeczywistych na pracę równoległego filtru aktywnego sterowanego ze sprzężeniem od prądu zasilającego
PublicationW artykule przedstawiono wpływ uwarunkowań rzeczywistych na pracę równoległego filtru aktywnego i zdolność kompensacji prądów harmonicznych. Zbadano wpływ opóźnień czasowych wynikających z implementacji cyfrowej sterowania, wpływ impedancji zwarciowej sieci zasilającej oraz błędów generowania napięcia przekształtnika na jakość kompensacji filtru. Badania symulacyjne przeprowadzono dla trzech układów sterowania: otwartego, zamkniętego...
-
Fault-tolerant performance of the novel five-phase doubly-fed induction generator
PublicationThe article presents the concept of a new design of a multi-phase doubly-fed induction generator (DFIG). The innovative design approach uses a five-phase power supply from the rotor side of the generator with a three-phase classic stator power supply. Modern three-phase doubly-fed induction generators are the dominant choice for Wind Energy Conversion Systems (WECS). Solutions of this type are sensitive to the loss of at least...
-
MPPT and GMPPT Implementation for Buck-Boost Mode Control of quasi-Z-Source Inverter
PublicationThe focus is on the maximum power point tracking implementation for the buck-boost voltage mode control of a single-phase multilevel inverter based on a three-level neutral point clamped quasi-Z-source topology. To utilize shoot-through states only when boost function is needed and avoid it in the buck mode, two different control approaches are required. This work proposes merged control system which provides switching between...
-
Failure analysis of a high-speed induction machine driven by a SiC-inverter and operating on a common shaft with a high-speed generator
PublicationDue to ongoing research work, a prototype test rig for testing high-speed motors/generators has been developed. Its design is quite unique as the two high- speed machines share a single shaft with no support bearings between them. A very high maximum operating speed, up to 80,000 rpm, was required. Because of the need to minimise vibration during operation at very high rotational speeds, rolling bearings were used. To eliminate...
-
Performance of the PEM fuel cell module. Part 2. Effect of excess ratio and stack temperature
PublicationThe paper describes a fuel cell based system performance under different thermal conditions. The system could be fed with bottled hydrogen or with very high purity hydrogen obtained from reforming of methanol. The system is based on two fuel cell units (1.2 kW each, produced by Ballard Power Systems Inc. and called Nexa), DC/DC converter, DC/AC inverter, microprocessor control unit, load unit, bottled hydrogen supply system and...
-
Power Hardware-In-the-Loop Approach for Autonomous Power Generation System Analysis
PublicationThe article presents the Power Hardware-In-the-Loop (PHIL) dynamic model of a synchronous generator of 125 kVA for autonomous power generation system analysis. This type of system is typically composed of electrical energy sources in the form of several diesel generator units with synchronous machines, the main distribution switchboard and different loads. In modern power distribution systems, the proposed power management strategies...
-
Transient modeling in common DC link of power converters
PublicationПредмет исследования. Представлена математическая модель силовых преобразователей электропривода, питающихся от общего звена постоянного тока, на примере тяговых электроприводов карьерного самосвала БЕЛАЗ-90 мощностью 280 кВт. Модель выполнена в пакете MATLAB/Simulink. Новизна предложенной модели заключается в применении новой топологии силовой схемы для исследования работы двух инверторов, под- ключенных к одному звену постоянного...
-
Broken rotor symptoms in the sensorless control of induction machine
PublicationThe purpose of this paper is to investigate the need for a universal method for sensorless controlled induction motor drive diagnosis. The increasing number of sensorless control systems in industrial applications require a universal method for the drive diagnosis, which provides reliable diagnostic reasoning independent of control system structure and state variables measurement or estimation method.Simulations and experimental...
-
Broken Rotor Symptons in the Sensorless Control of Induction Machine
PublicationInverter fed sensorless controlled variable speed drives with induction machine are widely used in the industry applications, also in wind power generation and electric vehicles. On-line self diagnostic systems implementation is needed for early stage fault detection and avoiding a critical fault. Diagnostic algorithms in modern DSP-based controllers can operate simultaneously with control system functions. In the closed-loop controlled...
-
Impact of digital signal processing on FOC current feedback in high-speed PMSM drive
PublicationIn applications where size and weight of the electric motor are among major design concerns, Permanent Magnet Synchronous Motors (PMSMs) with wide operational speed-range are commonly preferred. Due to limited inverter switching frequency, high-speed operation of a drive results in a low ratio between the switching frequency and the fundamental frequency of motor voltage. Such operating conditions have been recently identified...
-
BEZCZUJNIKOWE STEROWANIE WOLNOOBROTOWYM SILNIKIEM PMSM Z KOMPENSACJĄ MOMENTU ZACZEPOWEGO
PublicationW pracy przedstawiono propozycję rozwiązania problemu bezczujnikowego sterowania wolnoobrotową maszyną synchroniczną z magnesami trwałymi PMSM. Przedstawiono silnik PMSM, który zastosowano w stanowisku badawczym. Omówiono problem występowania tętnień momentu napędowego wynikający głównie ze znacznego momentu zaczepowego. Pokazano rozwiązanie kompensujące tętnienia momentu napędowego w silniku PMSM. Przygotowano procedurę startową...
-
Medium-Voltage Drives: Challenges and existing technology
PublicationThe article presents an overview of state-of-art solutions, advances, and design and research trends in medium-voltage (MV) drive technologies - and also discusses the challenges and requirements associated with the use of such drives. The choice and deployment of MV drives in industries are associated with numerous requirements related to the front-end converter (grid side) and inverter (machine side). The focus is on solutions...